page 1 of 13 - cpri.in07technicalbidsectioniicpriblr17rccdd041.pdfpage 1 of 13 revision no. : 03...

13
Page 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section : Formats Documents : PPM Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/℮TBID/GTP To be completed by the Bidder Guaranteed Technical Particulars (GTP) Specify deviations/ Remarks if any 1 Place where item to be supplied Cables & Diagnostics Division, Diagnostic Laboratory Central Power Research Institute, Bangalore 2 General: The PMT Modules, Power Supplies, Amplifiers Modules, Optical Blocks,and Stabilized Light Source for PMT Modules shall be used in a research project for research and developement of a novel optoelectronic technique for online patrial discharge monitoring of transformers Technical 3 Photo Multiplier Tube (PMT) Modules Cable Out Put Type 3 (a) PMT Modules (Current Output) confirming to the following specifications. 03 Nos. Spectral Response: 230 nm to 870 nm 3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for deputation of nominated CPRI officers. Name of the Vendor Sl.No. Parameters CPRI Specification / Requirements 2) All blue fields are mandatorily to be filled in. Quotation Number and Date Qty CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446 PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Section II -Technical Specification Tender Enquiry No : CPRIBLR17RCCDD04 Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source for PMT Modules Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected. PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825, TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Upload: ledien

Post on 12-Feb-2018

217 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 1 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

1 Place where item to be supplied Cables & Diagnostics Division, Diagnostic Laboratory Central Power

Research Institute, Bangalore

2 General: The PMT Modules, Power Supplies, Amplifiers Modules, Optical

Blocks,and Stabilized Light Source for PMT Modules shall be used in

a research project for research and developement of a novel

optoelectronic technique for online patrial discharge monitoring of

transformers

Technical

3 Photo Multiplier Tube (PMT) Modules Cable Out Put Type

3 (a) PMT Modules (Current Output) confirming to the following

specifications.

03 Nos.

Spectral Response: 230 nm to 870 nm

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 2: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 2 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Photo Cathode: Multialkali

Window Material: Borosilicate glass

Input Voltage: +11.5 V DC to +15.5 V DC

Max. Input Voltage: +18 V DC

Max. Input Current: 12 mA DC

Max. Average Output Signal Current: 100 µA DC

Max. Control Voltage: +1.1 V DC

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 3: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 3 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Recommended Control Voltage

Adjustment Range:

+0.5 V DC to 1.1 V DC

Effective Area: Φ8 mm

Peak Sensitivity Wave Length: 400 nm

Gain 5E3 or better @ min control voltage of 0.5 V DC to 4E6 or better @

max. control voltage of 1.1V

Cathode Luminous Sensitivity: 200 µA/lm

Cathode Red White Ratio: 0.2

Cathode Radient Sensitivity: 77 mA/W

Anode Luminous Sensitivity: 400 A/lm

Cath

od

eA

no

de

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 4: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 4 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Anode Radient Sensitivity: 1.5E5 A/W

Dark Current: 1 nA

Rise Time: 0.57 ns

Ripple Noise (peak to peak): 0.6 mV

Settling Time: 0.2 s

Operating Temperature: +5 ⁰C to +50 ⁰C

Storage Temperature: -20 ⁰C to +50 ⁰C

3 (b) PMT Modules (Voltage Output) confirming to the following

specifications.

03 Nos.

Spectral Response: 230 nm to 870 nm

An

od

e

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 5: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 5 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Photo Cathode: Multialkali

Window Material: Borosilicate glass

Inpu Voltage: ±11.5 V DC to ±15.5 V DC

Max. Input Voltage: ±18 V DC

Max. Input Current: +20/-8mA DC

Max. Output Signal Voltage: +10 V DC

Max. Control Voltage: +1.1 V DC

Recommended Control Voltage

Adjustment Range:

+0.5 V DC to 1.1 V DC

Effective Area: Φ8 mm

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 6: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 6 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Peak Sensitivity Wave Length: 400 nm

Gain 5E3 or better @ min control voltage of 0.5 V DC to 4E6 or better @

max. control voltage of 1.1V

Cathode Luminous Sensitivity: 200 µA/lm

Cathode Red White Ratio: 0.2

Cathode Radient Sensitivity: 77 mA/W

Anode Luminous Sensitivity: 4.0E7 V/lm

Anode Radient Sensitivity: 15 V/nW

Voltage Output dedpending on PMT Dark

Current:

0.1mV

Cath

od

eA

nod

e

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 7: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 7 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Frequency Band width (-3dB): DC to 200kHz

Current to Voltage Conversion Factor: 0.1 V/µA

Output Offset Voltage: ±1 mV

Ripple Noise (peak to peak): 1 mV

Settling Time: 0.2 s

Operating Temperature: +5 ⁰C to +50 ⁰C

Storage Temperature: -20 ⁰C to +50 ⁰C

4 Power Supply for PMT Modules confirming to the following

specifications. The power supply should be suitable for supplying

Input voltage and control voltage for the above PMT Modules.

03 Nos.

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 8: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 8 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Ouput Voltage: ±15 V DC

Output Current: 0.3 A (+15 V DC), 0.2 A (-15 V DC)

Control Voltage (a variable voltage

range):

+0.25V to +1.8 V

Input Voltage: AC 100 to AC 240, 50Hz

5 Amplifier Units confirming to the following specifications. 03 Nos.

Frequency Bandwidth (-3dB): DC to 1MHz

Current to Voltage Conversion Factor: 1 V/µA

Rise time: 350 ns

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 9: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 9 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

Signal Input Polarity (Output): Positive/Negative

Amplifying Method: Inverting Output

Outpu Impedance: 50 Ω

Max. Ouput Voltage: ±11 V (1 kΩ load resistance), ±3 V (50 Ω load resistance)

Output Noise Voltage 1 mV rms

Signal Connector: Input: BNC-R, Output: BNC-R

Power Supply Voltage: ±15 V DC

Max. Power Supply Voltage: ±18 V DC

Max. Power Supply Current: ±100 mA DC

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 10: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 10 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

6(a) Fiber Adapter Block (Visible): Optical Fiber cables with FC connectors can be connected to the

blocks. The lens assembly in the block should collimate the light

spread from the optical fiber with focal length of 10 mm.

03Nos.

6(b) Fiber Adapter Block (Ultra Violet): Optical Fiber cables with SMA connectors can be connected to the

blocks. The lens assembly in the block should collimate the light

spread from the optical fiber with focal length of 10 mm.

03Nos.

7 Adapter Block: Adapter block should be suitable for connecting PMT module to an

optical block with V-groove connector.

03Nos.

8(a) Optical Fiber adapter Sub Miniature A

Type (SMA Type):

Optical fiber adapter allows connection to an optical fiber cable which

has SMA connector. Guiding the light with an optical fiber should be

easily performed by fixing this adaptor to incident surface of the

photomultiplier tube module.

06 Nos.

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 11: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 11 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

8(b) Optical Fiber adapter Fiber Channel Type

(FC Type):

Optical fiber adapter allows connection to an optical fiber cable which

has FC connector. Guiding the light with an optical fiber should be

easily performed by fixing this adaptor to incident surface of the

photomultiplier tube module.

06 Nos.

9 Stabilised Light Source The light source should be suitable for adjusting the sensitivity of PMT

modules. The light source should confirm to the following

specifications.

01 No.

Peak emission wave length: 465 nm

Spectral half width: 26 nm

Light emission power: 1±0.5 pW

Emisssion Stability: ±2% Max. (0 ⁰C to +50 ⁰C )

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 12: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 12 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

10 Manual: Original data sheet, test certificate, operating & maintenance manual

in English with detailed circuit diagram indicating the values covering

all passive & active components-01 Set for each of the above listed

items.

01 Set

11 Warranty: One year warranty from the date of successful commissioning at CPRI.

12 Inspection and qualification requirements The Photo Multiplier Tube (PMT) modules shall be tested and

demonstrated for its functionality by the supplier representative by

using the stabilised light source, power supply modules and amplifier

mdodules etc. The item supplied should be free from any physical

damages and should function satisfactorily with stabilised light source,

power supply modules and amplifier modules etc.

13 Payment Terms: 100% payment by RTGS within 30 days after receipt of material and

satisfactory functionality test.

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in

Page 13: Page 1 of 13 - cpri.in07TechnicalBidSectionIICPRIBLR17RCCDD041.pdfPage 1 of 13 Revision No. : 03 Issue No : 2 Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003 Issued by : P A Section

Page 13 of 13

Revision No. : 03 Issue No : 2

Dt of Revision : 25.07.2017 Issue Dt. : 30.06.2003

Issued by : P A

Section : Formats Documents : PPM

Topic : e-Tender Technical Specification Document FORMAT NO.:CPRI/PUR/TBID/GTP

To be completed by the BidderGuaranteed

Technical

Particulars (GTP)

Specify

deviations/

Remarks if any

3) Pre-despatch Inspection & Training expenses shall be borne by CPRI. Information regarding the readiness of the equipment/machinery for the Pre-despatch

Inspection should be communicated in writing by the supplier at least 70 (Seventy) days in advance, to obtain clearence from the Ministry, Government of India for

deputation of nominated CPRI officers.

Name of the Vendor

Sl.No. Parameters CPRI Specification / Requirements

2) All blue fields are mandatorily to be filled in.

Quotation Number and Date

Qty

CENTRAL POWER RESEARCH INSTITUTE, BANGALORE Web: www.cpri.in, www.tenderwizard.com/CPRI, Telefax: 080-2360 4446

PROCUREMENT PROCEDURE OF CPRI (NON WORKS)

Section II -Technical Specification

Tender Enquiry No : CPRIBLR17RCCDD04

Description of the Equipment/Goods/Services : Photo multiplier Tube (PMT) Modules, Power Supplies, Amplifier Modules, Optical Blocks and Stabilized Light source

for PMT Modules

Note : 1) The Offers should be submitted only in this format otherwise the offer will be liable to be rejected.

14 Delivery Period: Within 6 months from the date of issue of Purchase Order.

PN: 1) Bidder shall indicate complete details/information how the CPRI GTP are complied with against each and every specification parameters & mere statement of 'complied' do not suffice the

requirement.

3) The Indian representative of the foreign/overseas firms shall submit the Letter of Authorization issued by their principals.

Address : Joint Director (Purchase), Purchase Authrity , Central Power Research Institute, Sadashiva Nagar P.O., P.Box.No.8066, Bengaluru-560080.

Telefax: 080-23604446., email:[email protected] , web : www.cpri.in

4)The bidder shall submit the quotation / offer in the above prescribed format of Section IA , IB and II only . Informations any other forms shall shall be rejected.

2)A detailed technical/catalogue/literature/phamplet and any other technocal details shall be submitted in hard copy in a sealed cover superscribing enquiry number and due date so as to reach the

below mentioned address within due date and time.

PURCHASE DIVISION, CENTRAL POWER RESEARCH INSTITUTE, PROF.SIR C.V.RAMAN ROAD, SADASHIVANAGAR POST, P.B. No.8066, BENGALURU, KARNATAKA. INDIA, PH:080 2360 2919/0825,

TELE FAX : 080 2360 4446, E-mail : [email protected], Web : http:www.cpri.in