pdb saudi split (titan gold plus+fresh+smart)

Upload: 1969mazhar

Post on 02-Jun-2018

288 views

Category:

Documents


13 download

TRANSCRIPT

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    1/65

    60Hz(R22)

    SR-6RMG2-02A

    Saudi Arabia

    General Wall Mounted

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    2/65

    2 GENERAL WALL MOUNTED

    GENERAL WALL MOUNTED

    Contents

    1. Models Line up .............................................................................6

    2. Nomenclature ...............................................................................7

    3. Features & Benefits......................................................................8

    4. Specifications .............................................................................10

    5. Dimensional Drawings...............................................................17

    6. Wiring Diagrams.........................................................................22

    7. Refrigerant Cycle Diagram ........................................................33

    8. Capacity Tables ..........................................................................34

    9. Capacity Coefficient factor........................................................41

    10. Air Velocity and Temperature Distribution(Reference Data).......................................................................43

    11. Controller ..................................................................................44

    12. Installation ................................................................................47

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    3/65

    3

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Test condition of international standard

    KSC ISO ARI AHAM AS SSA 9306 5151 210/240 1861.1 385

    Indoor

    DBC(F) 27.0 27.0 26.7(80) 26.7(80) 27.0 29.0

    Cooling WBC(F) 19.5 19.0 19.4(67) 19.4(67) 19.0 19.0

    CapacityOutdoor

    DBC(F) 35.0 35.0 35.0(95) 35.0(95) 35.0 46.0

    WBC(F) 24.0 24.0 23.9(75) 23.9(75) 24.0 24.0

    Indoor

    DBC(F) 20.0 20.0 21.1(70) 21.1(70) 21.0 21.0

    Heating WBC(F) 15.0 15.0 15.6(60) 15.6(60) 15.0 15.5

    CapacityOutdoor

    DBC(F) 7.0 7.0 8.3(47) 8.3(47) 7.0 7.0

    WBC(F) 6.0 6.0 6.1(43) 6.1(43) 6.0 6.0

    Indoor

    DBC(F) 32.0 32.0 26.7(80) 32.2(90) 32.0 29.0Maximum

    WBC(F) 23.0 23.0 19.4(67) 22.8(73) 23.0 19.0Cooling

    Outdoor DBC(F) 43.0 43.0 46.1(115) 43.3(110) 43.0 54.0

    Operating WBC(F) 26.0 26.0 23.9(75) 25.6(78) 26.0 24.0

    Indoor

    DBC(F) 27.0 27.0 26.7(80) 26.7(80) - -Maximum

    WBC(F) 19.0 19.0 19.4(67) 22.8(73) - -Heating

    Outdoor

    DBC(F) 21.0 24.0 23.9(75) 23.9(75) - -Operating

    WBC(F) 15.0 18.0 18.3(65) 18.3(65) - -

    EnclosureIndoor

    DBC(F) 27.0 27.0 26.7(80) 26.7(80) 27.0 27.0

    Sweat / WBC(F) 24.0 24.0 23.9(75) 23.9(75) 24.0 24.0

    CondensateOutdoor

    DBC(F) 27.0 27.0 26.7(80) 26.7(80) 27.0 27.0

    Disposal WBC(F) 24.0 24.0 23.9(75) 23.9(75) 24.0 24.0

    Freeze-up/ Indoor DBC(F) 21.0 21.0 19.4(67) 21.1(70) 21.0 21.0

    Low WBC(F) 15.0 15.0 13.9(57) 15.6(60) 16.0 16.0

    Temperature

    Outdoor DBC(F) 21.0 21.0 19.4(67) 21.1(70) 21.0 21.0

    WBC(F) 15.0 15.0 13.9(57) 15.6(60) 16.0 16.0

    KS : Korea Standard AS : Australia Standard

    ISO : International Standard Organization SSA : Saudi Arabian StandardARI : Airconditioning and Refrigeration InstituteAHAM : Association of Home Appliance Manufacturers

    CLASSIFICATION

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    4/65

    4

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    General Description

    Split type of Air Conditioners are known by the category name of Wall Mounted Type of units.These units can beeasily installed in a small space and have exceptional Cooling capacity.Designed for Low-noise operation,itensures a pleasant air conditioned environment.

    LG Offers various types of units to its customers to suit for the best application and requirement.The following are

    the important categories offered by LG :1) General Wall Mounted Type Units : Units with Simplicity in design.

    2) Art Cool Units : A new concept of cooling introduced by LG in the field of Air Conditioning.

    3) New Gas Models : These models uses HCFC free refrigerant to provide a healthy environment to the world.

    Some of the Important Features of these units are listed below :

    1) Providing Health to the Customers : By having Filters such as Plasma Filter which is capable of removing MicroOrganisms up to 0.1 microns.

    2) Long Term Money Saving : By providing Features such as Gold Fin,Plasma Fin, Auto Clean etc. to maintain thesame performance for years.

    3) Best Comfort : With Features such as Sleep Mode,Timer,Auto Restart etc.

    These Units are available with many standard and optional features which gives our Customers the choice to selectthe unit of their own desire.For details refer to the Detailed specification followed after this description.

    LG Electronics Inc.Air Conditioning & Energy Solution Company

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    5/65

    5

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Publication historyPDB No. Product Name Notes Publication in

    SR-6RMG2-01A SRAC 4Models Dec. 2012

    SR-6RMG2-02A SRAC 10 Models May. 2013

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    6/65

    6

    Models Line up SR-6RMG2-02A

    GENERAL WALL MOUNTED

    1. Models Line upGeneral Wall Mounted

    Edition Capacity Chassis Type Factory Model Buyer Model

    #1

    18K SC C/O GS-C182C4B2

    H/P GS-H182C4B2

    24K SC C/O GS-C242C4B2

    H/P GS-H242C4B2

    #2

    12K SE C/O GS-C122E5B2

    H/P GS-H122E5B2

    18K S5

    C/O GS-C1825SA3

    H/P GS-H1825SA3

    C/O GS-C1825NB2

    H/P GS-H1825NB2

    24K S5

    C/O GS-C2425SA3

    H/P GS-H2425SA3

    C/O GS-C2425NB2

    H/P GS-H2425NB2

    -

    -

    -

    -

    S122NC

    S122NH

    S182SC

    S182SH

    S182NC

    S182NH

    S242SC

    S242SH

    S242NC

    S242NH

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    7/65

    7

    Nomenclature SR-6RMG2-02A

    GENERAL WALL MOUNTED

    2. Nomenclature Identification Rule

    Serial Number

    FunctionB: 4Way

    Look/Color

    Chassis NameC: SC

    Electric Rating2: 220V, 60Hz

    CapacityEX) '18' 18,000Btu/h Class

    Model TypeC: Cooling OnlyH: Heat Pump

    Product TypeS: Split

    Refrigerant TypeG: R22

    Supply Method Diving and Type-: SET

    G S C- 81 2 C 4 B 1

    Chassis Look ClassificationSC 4 ICE-E (White)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    8/65

    8

    Features & Benefits SR-6RMG2-02A

    GENERAL WALL MOUNTED

    3. Features & Benefits

    SmokeAway GoldFin TropicalCompressor

    StylishDesign

    Quick & EasyInstallation

    Skew Fan DualProtection Filter

    Vane &Louver

    Extreme Durability

    The advanced tropical compressor withstandsextreme weather conditions, enabling theproduct to operate despite high outside tem-perature.

    By adopting gold plated fins in the exteriorunit, the heat exchanger is protected from cor-rosion and wear from external conditions.

    The combination of tropical compressor,and the gold fin in the exterior unit allcontribute in the improved durability of LG airconditioner.

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    9/65

    9

    Features & Benefits SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Power Cooling

    Perfect Health Care

    Energy Saving

    Stylish Design

    Quick & Easy Installation

    20m Windblast : Strong and cool windblastcovers the distance of 20m.

    Optimized Airflow : The interior of the com-pressor in the outdoor unit has been construct-ed to minimze the sound produced when oper-ating.

    The cool airflow reaches thedistance of 15m to all corners ofthe room, keeping the space cooland comfortable regardless ofoutside temperature.

    Smoke Away : 3 million ionsspread from diffusion charger and 3M MicroProtection filter remove smoke particle asmuch as air-purifier removes.* Test Results

    Size of Area : 30m 3, CADR : 135

    Dual Protection Filter : Dual Protection Filterinitially captures dust in the air that comes into the air conditioner.

    Filter : While being easy to main-tain, the powerful plasma filtration system ofLG air conditioner protects the user from odorand any harmful substances floating in air.

    3M Multi Protection Filter : 3M MultiProtection filter captures dust, virus and aller-gen and deactivates the captured virus andallergen by unique technologies of LG and 3M.

    Various filtration system protects the userfrom all harmful substances including odor,bacteria, and allergen

    Inverter V : The advanced inverter technologyof LG enables the user of the air conditioner touse more and save more.

    State of the art heat exchanger, air outlet,compressor, and inverter technology providethe world s highest energy efficiency

    The design of LG air conditioners are stylish ina way that is incomparable to others. Think of

    it not just as an air conditioner, but an objetthat will lighten up your living room.

    LG air conditioners are not just refreshinglyefficient, but also exceptionally elegant indesign

    Perfect finishing / Bigger tubing space / Installationplate improvement / Detachable bottom cover / Elevated service valve / Installation support clip / Compatible with inverter multi system

    Installation has never been easier as with thedelicately designed installation elements ofLG air conditioners

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    10/65

    10

    Specifications SR-6RMG2-02A

    GENERAL WALL MOUNTED

    4. SpecificationsGeneral Wall Mounted(#1)

    Note:

    O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.

    Some of functions are slightly different depending upon models.The specification may be subject to change without notic for purpose of improvement.

    Model Name (LG) GS-C182C4B2 GS-H182C4B2Pet Name Gold Plus Gold Plus

    Cooling Capacity (T1) W 5,250 5,130Btu/h. 17,914 17,504

    Heating Capacity (H1) W - 5,250Btu/h. - 17,914

    Power Input Normal Cooling W 2,050 2,150Heating W - 1,750Running Current(Normal)

    Cooling A 9.6 10.0Heating A - 8.0

    EERW/W 2.56 2.39

    Btu/h.W 8.74 8.14(STAR) 3 2

    COP W/W - 3.00

    Power Factor Cooling % 97% 98%Heating % - 99%

    Cooling Capacity (T3) W 4,600 4,450Btu/h. 15,696 15,184Power Input (T3) W 2,500 2,450Running Current (T3) A 11.5 11.5

    EER W/W 1.84 1.82Btu/h.W 6.28 6.20Power Factor % 98.81 96.84

    Power Input (Max) Cooling W 2,900 2,900Heating W - 1,890Running Current(Max)

    Cooling A 13.5 13.5Heating A - 8.9

    Power Factor Cooling % 97.64 97.64Heating % - 96.53Power Supply / V / Hz 1/220/60 1/220/60

    Air Circulation Indoor m3/min(CFM),Max 13.0 (460) 13.0 (460)

    Outdoor m3/min(CFM),Max 45 (1,590) 45 (1,590)

    Moisture Removal /h. 1.9 1.9Noise Level(SoundPressure,1m)

    IndoordB(A)3,High 43 43dB(A)3,Med 40 40dB(A)3,Low 37 37

    Outdoor dB(A)3,Max 56 56

    Refrigerant Charge Type R22 R22g 970 970

    Compressor

    Type ROTARY ROTARYModel QJ278KCF QJ278KCFMaker LG LGCapacity kcal/h.(Btu/h.) 5,744(19,600) 5,744(19,600)Motor Type PSC PSCMotor Input W 1,867 1,867Oil Type SUNISO 4GSI or NOC NM56 SUNISO 4GSI or NOC NM56Oil Charge cc 500 500O.L.P Name INTERNAL INTERNAL

    Blower Motor Type Cross Flow Fan Cross Flow FanOutput W 22 22

    Fan MotorType Axial fan Axial fanMotor Type AC Induction AC InductionMotor Output W 64 64

    Circuit Breaker A 20 20Power Cord AWG#:P*mm2 3x1.5 3x2.0Connecting Cable AWG#:P*mm2 3x1.5 3x2.0+2x0.75Connecting Tube(. Socket Flare)

    Liquid Side mm(in) 6.35(1/4") 6.35(1/4")Gas Side mm(in) 15.88(5/8") 15.88(5/8")Length,std m(in) 5(196) 5(196)

    Drain Hose (O.D , I.D) mm(in) 21.5,16 (0.85,0.63) 21.5,16 (0.85,0.63)

    Dimension

    Indoor(W*H*D)

    mm 1030*320*245 1030*320*245inch 40.5*12.6*9.6 40.5*12.6*9.6

    Outdoor(W*H*D)

    mm 870*655*320 870*655*320inch 34.25*25.79*12.6 34.25*25.79*12.6

    Net Weight Indoor kg(lbs) 12.6(27.8) 13(28.7)Outdoor kg(lbs) 40.5(89.3) 42(92.6)Stuffing Quantity In+Out 20/40ft/HC/Truck 57/124/139/- 57/124/139/-Tool Code In+Out SC+UE SC+UE

    Functions

    AIR FLOW

    Air supply outlet 1 1Airflow direction control(left & right) Auto AutoAirflow direction control(up & down) Auto AutoAuto swing(left & right) Auto AutoAuto swing(up & down) Auto AutoAirflow steps(fan/cool/heat) 3/4/- 3/4/3Chaos swing Yes YesChaos wind(auto wind) Yes YesJet cool(Power wind) Yes Yes

    Air purifyingDeodorizing filter (Allergy & H1N1 Filter) - -Plasma air purifier - -Prefilter(washable / anti-fungus) Yes Yes

    ReliabilityHot start - YesSelf diagnosis Yes YesSoft dry operation Yes Yes

    Convenience

    Setting Temperature, Cooling 18 - 30 18 - 30Setting Temperature, Heating - 16 - 30Auto changeover - YesAuto cleaning Yes YesAuto operation(artificial intelligence) Yes -Auto restart operation Yes YesForced operation Yes YesSleep mode Yes YesSetting Temperature Range (Cooling) 18-30 18-30Setting Temperature Range (Heating) 16-30 16-30Temperature Increment 1 1Timer(Hr) Yes (24h On/Off) Yes (24h On/Off)

    Individualcontrol

    Wireless remote controller(simple) - -Wireless LCD remote control Yes(Type1) Yes(Type1)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    11/65

    11

    Specifications SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Note:

    O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.

    Some of functions are slightly different depending upon models.The specification may be subject to change without notic for purpose of improvement.

    Model Name (LG) GS-C242C4B2 GS-H242C4B2Pet Name Gold Plus Gold Plus

    Cooling Capacity (T1) W 6,600 6,600Btu/h. 22,520 22,520

    Heating Capacity (H1) W - 6,700Btu/h. - 22,861

    Power Input Normal Cooling W 2,650 2,650Heating W - 2,500Running Current(Normal)

    Cooling A 12.6 12.6Heating A - 12.0

    EERW/W 2.49 2.49

    Btu/h.W 8.50 8.50(STAR) 3.00 3.00

    COP W/W - 2.68

    Power Factor Cooling % 96% 96%Heating % - 95%

    Cooling Capacity (T3) W 5,750 5,750Btu/h. 19,620 19,620Power Input (T3) W 3,080 3,080Running Current (T3) A 14.5 14.5

    EER W/WBtu/h.W 6.37 6.37Power Factor % 96.55 96.55

    Power Input (Max) Cooling W 4,000 4,000Heating W - 2,900Running Current(Max)

    Cooling A 18.5 18.5Heating A - 14.0

    Power Factor Cooling % 98.28 98.28Heating % - 94.16Power Supply / V / Hz 1/220/60 1/220/60

    Air Circulation Indoor m3/min(CFM),Max 16.0(566) 16.0(566)

    Outdoor m3/min(CFM),Max 48 (1,695) 48 (1,695)

    Moisture Removal /h. 2.5 2.5Noise Level(SoundPressure,1m)

    IndoordB(A)3,High 43 43dB(A)3,Med 40 40dB(A)3,Low 37 37

    Outdoor dB(A)3,Max 56 56

    Refrigerant Charge Type R22 R22g 1550 1550

    Compressor

    Type ROTARY ROTARYModel QP362KBB QP362KBBMaker LG LGCapacity kcal/h.(Btu/h.) 7,911(27,000) 7,911(27,000)Motor Type PSC PSCMotor Input W 2,571 2,571Oil Type NM56 or SUNISO 4GSI NM56 or SUNISO 4GSIOil Charge cc 700 700O.L.P Name INTERNAL INTERNAL

    Blower Motor Type Cross Flow Fan Cross Flow FanOutput W 25.6 25.6

    Fan MotorType Axial fan Axial fanMotor Type AC Induction AC InductionMotor Output W 64 64

    Circuit Breaker A 30 30Power Cord AWG#:P*mm2 3x2.5 3x2.5Connecting Cable AWG#:P*mm2 3x2.5 3x2.5+2x0.75Connecting Tube(. Socket Flare)

    Liquid Side mm(in) 9.52(3/8") 9.52(3/8")Gas Side mm(in) 15.88(5/8") 15.88(5/8")Length,std m(in) 5(196) 5(196)

    Drain Hose (O.D , I.D) mm(in) 21.5,16 (0.85,0.63) 21.5,16 (0.85,0.63)

    Dimension

    Indoor(W*H*D)

    mm 1030*320*245 1030*320*245inch 40.5*12.6*9.6 40.5*12.6*9.6

    Outdoor(W*H*D)

    mm 870*655*320 870*655*320inch 34.25*25.79*12.6 34.25*25.79*12.6

    Net Weight Indoor kg(lbs) 13.6(30.0) 13.6(30.0)Outdoor kg(lbs) 50,5(111.33) 50,5(111.33)Stuffing Quantity In+Out 20/40ft/HC/Truck 57/124/139/- 57/124/139/-Tool Code In+Out SC+UE SC+UE

    Functions

    Air flow

    Air supply outlet 1 1Airflow direction control(left & right) Auto AutoAirflow direction control(up & down) Auto AutoAuto swing(left & right) Auto AutoAuto swing(up & down) Auto AutoAirflow steps(fan/cool/heat) 3/4/- 3/4/3Chaos swing Yes YesChaos wind(auto wind) Yes YesJet cool(Power wind) Yes Yes

    Air purifyingDeodorizing filter (Allergy & H1N1 Filter) - -Plasma air purifier - -Prefilter(washable / anti-fungus) Yes Yes

    ReliabilityHot start - YesSelf diagnosis Yes YesSoft dry operation Yes Yes

    Convenience

    Setting Temperature, Cooling 18 - 30 18 - 30Setting Temperature, Heating - 16 - 30Auto changeover - YesAuto cleaning Yes YesAuto operation(artificial intelligence) Yes -Auto restart operation Yes YesForced operation Yes YesSleep mode Yes YesSetting Temperature Range (Cooling) 18-30 18-30Setting Temperature Range (Heating) 16-30 16-30Temperature Increment 1 1Timer(Hr) Yes (24h On/Off) Yes (24h On/Off)

    Individualcontrol

    Wireless remote controller(simple) - -Wireless LCD remote control Yes(Type1) Yes(Type1)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    12/65

    12

    Specifications SR-6RMG2-02A

    GENERAL WALL MOUNTED

    General Wall Mounted(#2)Model Name (LG) GS-C122E5B2 GS-H122E5B2

    Pet Name Fresh Fresh

    Cooling Capacity (T1) WBtu/h.

    Heating Capacity (H1) WBtu/h.

    Power Input Normal Cooling WHeating WRunning Current(Normal)

    Cooling AHeating A

    EERW/W

    Btu/h.W

    (STAR)COP W/W

    Power Factor Cooling %Heating %

    Cooling Capacity (T3) WBtu/h.Power Input (T3) WRunning Current (T3) A

    EER W/WBtu/h.WPower Factor %

    Power Input (Max) Cooling WHeating WRunning Current(Max)

    Cooling AHeating A

    Power Factor Cooling %Heating %Power Supply / V / Hz

    Air Circulation Indoor m3/min(CFM),Max

    Outdoor m 3/min(CFM),MaxMoisture Removal l / h.

    Noise Level(SoundPressure,1m)

    IndoordB(A)+3,HighdB(A)+3,MeddB(A)+3,Low

    Outdoor dB(A)+3,Max

    Refrigerant Charge Typeg

    Compressor

    TypeModelMakerCapacity kcal/h.(Btu/h.)Motor TypeMotor Input WOil TypeOil Charge ccO.L.P Name

    Blower Motor TypeOutput W

    Fan MotorTypeMotor TypeMotor Output W

    Circuit Breaker APower Cord AWG#:P*mm 2Connecting Cable AWG#:P*mm 2

    Connecting Tube( . Socket Flare)

    Liquid Side mm(in)Gas Side mm(in)Length,std m(in)

    Drain Hose (O.D , I.D) mm(in)

    Dimension

    Indoor(W*H*D)

    mminch

    Outdoor(W*H*D)

    mminch

    Net Weight Indoor kg(lbs)Outdoor kg(lbs)Tool Code In+Out

    Operation Range Cooling(Outdoor) C(F)Heating(Outdoor) C(F)Max. Piping Length m(ft)Max. Elevation Difference m(ft)

    Functions

    Air flow

    Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan/cool/heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)

    Air purifyingDeodorizing filter (Allergy & H1N1 Filter)Plasma air purifier

    Prefilter(Dual Protection Filter)Reliability

    Hot startSelf diagnosisSoft dry operation

    Convenience

    Setting Temperature, CoolingSetting Temperature, HeatingAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationForced operationSleep modeSetting Temperature Range (Cooling)Setting Temperature Range (Heating)Temperature IncrementTimer(Hr)

    Individual control Wireless remote controller(simple)Wireless LCD remote control

    Note:O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.

    Some of functions are slightly different depending upon models.The specification may be subject to change without notic for purpose of improvement.

    3,520 3,37212,011 11,506

    - 3,520- 12,011

    1,200 1,200- 1,150

    5.5 5.5- 5.3

    2.93 2.8110.01 9.59

    6 5- 3.0699% 99%

    - 99%3100 3000

    10,578 10,2361400 14006.5 6.5

    2.21 2.147.56 7.31

    97.90 97.901500 1500

    - 13506.9 6.9- 6.2

    98.81 98.81- 98.97

    1/220/60 1/220/6010 10

    33 (1,165) 33 (1,165)1.54 1.4540 4034 3430 3048 48

    R22 R22850 910

    ROTARY ROTARYQK185KBE QK185KBE

    LG LG3276 (13,000) 3276 (13,000)

    PSC PSC1215 1215

    4GSI or NM56 4GSI or NM56350 350

    MRA12070-12027 MRA12070-12027Cross Flow Fan Cross Flow Fan

    15.1 15.1Axial fan Axial fan

    AC Induction AC Induction41 4115 15

    3x1.0 3x1.03x1.0 3x1.0+2x0.75

    6.35(1/4) 6.35(1/4)12,7(1/2") 12,7(1/2")

    5(196) 5(196)21.5,16(0.85,0.63) 21.5,16(0.85,0.63)

    890*282*165 890*282*16532.24*11.1*6.5 32.24*11.1*6.5770*540*245 770*540*245

    30,31*21,25*9,64 30,31*21,25*9,649.0(19.8) 9.0(19.8)

    30.0(66.1) 32.0(70.5)SE+UL SE+UL

    21~54(69.8~129.2) 21~54(69.8~129.2)- 1~24(33.8~75.2)

    15(49.2) 15(49.2)10(33) 10(33)

    1 1Auto AutoAuto AutoAuto AutoAuto Auto3/4/- 3/4/3Yes YesYes YesYes Yes

    - -- -

    Yes Yes- YesYes YesYes Yes

    18 - 30 18 - 30- 16 - 30- Yes

    Yes YesYes -Yes YesYes YesYes Yes

    18-30 18-30- 16-301 1

    Yes (24h On/Off) Yes (24h On/Off)- -

    Yes(Type2) Yes(Type2)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    13/65

    13

    Specifications SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model Name (LG) GS-C1825SA3 GS-H1825SA3Pet Name Smart Smart

    Cooling Capacity (T1) WBtu/h.

    Heating Capacity (H1) WBtu/h.

    Power Input Normal Cooling WHeating WRunning Current(Normal)

    Cooling AHeating A

    EERW/W

    Btu/h.W

    (STAR)COP W/W

    Power Factor Cooling %Heating %

    Cooling Capacity (T3) WBtu/h.Power Input (T3) WRunning Current (T3) A

    EER W/WBtu/h.WPower Factor %

    Power Input (Max) Cooling WHeating WRunning Current(Max)

    Cooling AHeating A

    Power Factor Cooling %Heating %Power Supply / V / Hz

    Air Circulation Indoor m3/min(CFM),Max

    Outdoor m 3/min(CFM),MaxMoisture Removal l / h.

    Noise Level(SoundPressure,1m)

    IndoordB(A)+3,HighdB(A)+3,MeddB(A)+3,Low

    Outdoor dB(A)+3,Max

    Refrigerant Charge Typeg

    Compressor

    TypeModelMakerCapacity kcal/h.(Btu/h.)Motor TypeMotor Input WOil TypeOil Charge ccO.L.P Name

    Blower Motor TypeOutput W

    Fan MotorTypeMotor TypeMotor Output W

    Circuit Breaker APower Cord AWG#:P*mm 2Connecting Cable AWG#:P*mm 2

    Connecting Tube( . Socket Flare)

    Liquid Side mm(in)Gas Side mm(in)Length,std m(in)

    Drain Hose (O.D , I.D) mm(in)

    Dimension

    Indoor(W*H*D)

    mminch

    Outdoor(W*H*D)

    mminch

    Net Weight Indoor kg(lbs)Outdoor kg(lbs)Tool Code In+Out

    Operation Range Cooling(Outdoor) C(F)Heating(Outdoor) C(F)Max. Piping Length m(ft)Max. Elevation Difference m(ft)

    Functions

    Air flow

    Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan/cool/heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)

    Air purifyingDeodorizing filter (Allergy & H1N1 Filter)Plasma air purifier

    Prefilter(Dual Protection Filter)Reliability

    Hot startSelf diagnosisSoft dry operation

    Convenience

    Setting Temperature, CoolingSetting Temperature, HeatingAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationForced operationSleep modeSetting Temperature Range (Cooling)Setting Temperature Range (Heating)Temperature IncrementTimer(Hr)

    Individual control Wireless remote controller(simple)Wireless LCD remote control

    Note:O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.

    Some of functions are slightly different depending upon models.The specification may be subject to change without notic for purpose of improvement.

    5,130 4,99017,504 17,027

    - 5,100- 17,391

    2,000 2,100- 1,750

    9.5 10.0- 8.0

    2.57 2.388.75 8.11

    3 2- 2.9196% 95%

    - 99%4,500 4,300

    15,355 14,6722,300 2,450

    11 11.51.96 1.766.68 5.99

    95.04 96.842,564 2,515

    - 2,10012.00 12.0

    - 9.697.12 95.27

    - 99.431/220/60 1/220/60

    13.0 (459) 13.0 (459)33 (1165) 48 (1,695)

    1.8 2.040 4037 3734 3454 56

    R22 R22720 1000

    ROTARY ROTARYQJ278KCF QJ278KCF

    LG LG5,744(19,600) 5,744(19,600)

    PSC PSC1,867 1,867

    4GSI or NM56 4GSI or NM56500 500

    INTERNAL INTERNALCross Flow Fan Cross Flow Fan

    20.6 20.6Axial fan Axial fan

    AC Induction AC Induction41 63.620 20

    3x1.5 3x1.53x1.5 3x1.5+2x0.75

    6.35(1/4") 6.35(1/4")15.88(5/8") 15.88(5/8")

    5(196) 5(196)21.5,16 (0.85,0.63) 21.5,16 (0.85,0.63)

    1090*300*180 1090*300*18042.9*11.8*7.09 42.9*11.8*7.09

    770*540*245 870*655*32030.3*21.3*9.7 34.25*25.79*12.6

    11.5(25.4) 11.5(25.4)34(75.0) 45,5(100.3)S5+UL S5+UE

    21~54(69.8~129.2) 21~54(69.8~129.2)- 1~24(33.8~75.2)

    15(49.2) 15(49.2)10(33) 10(33)

    1 1Manual Manual

    Auto AutoManual Manual

    Auto Auto-/4/- -/4/3Yes YesYes YesYes Yes

    - -- -

    Yes Yes- YesYes YesYes Yes

    18 - 30 18 - 30- 16 - 30- -- -- -

    Yes YesYes YesYes Yes

    18-30 18-30- 16-301 1

    Yes (7h Off) Yes (24h Off)Yes(Type3) Yes(Type3)

    - -

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    14/65

    14

    Specifications SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model Name (LG) GS-C1825NB2 GS-H1825NB2Pet Name Fresh Fresh

    Cooling Capacity (T1) WBtu/h.

    Heating Capacity (H1) WBtu/h.

    Power Input Normal Cooling WHeating WRunning Current(Normal)

    Cooling AHeating A

    EERW/W

    Btu/h.W

    (STAR)COP W/W

    Power Factor Cooling %Heating %

    Cooling Capacity (T3) WBtu/h.Power Input (T3) WRunning Current (T3) A

    EER W/WBtu/h.WPower Factor %

    Power Input (Max) Cooling WHeating WRunning Current(Max)

    Cooling AHeating A

    Power Factor Cooling %Heating %Power Supply / V / Hz

    Air Circulation Indoor m3/min(CFM),Max

    Outdoor m 3/min(CFM),MaxMoisture Removal l / h.

    Noise Level(SoundPressure,1m)

    IndoordB(A)+3,HighdB(A)+3,MeddB(A)+3,Low

    Outdoor dB(A)+3,Max

    Refrigerant Charge Typeg

    Compressor

    TypeModelMakerCapacity kcal/h.(Btu/h.)Motor TypeMotor Input WOil TypeOil Charge ccO.L.P Name

    Blower Motor TypeOutput W

    Fan MotorTypeMotor TypeMotor Output W

    Circuit Breaker APower Cord AWG#:P*mm 2Connecting Cable AWG#:P*mm 2

    Connecting Tube( . Socket Flare)

    Liquid Side mm(in)Gas Side mm(in)Length,std m(in)

    Drain Hose (O.D , I.D) mm(in)

    Dimension

    Indoor(W*H*D)

    mminch

    Outdoor(W*H*D)

    mminch

    Net Weight Indoor kg(lbs)Outdoor kg(lbs)Tool Code In+Out

    Operation Range Cooling(Outdoor) C(F)Heating(Outdoor) C(F)Max. Piping Length m(ft)Max. Elevation Difference m(ft)

    Functions

    Air flow

    Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan/cool/heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)

    Air purifyingDeodorizing filter (Allergy & H1N1 Filter)Plasma air purifier

    Prefilter(Dual Protection Filter)Reliability

    Hot startSelf diagnosisSoft dry operation

    Convenience

    Setting Temperature, CoolingSetting Temperature, HeatingAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationForced operationSleep modeSetting Temperature Range (Cooling)Setting Temperature Range (Heating)Temperature IncrementTimer(Hr)

    Individual control Wireless remote controller(simple)Wireless LCD remote control

    Note:O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.

    Some of functions are slightly different depending upon models.The specification may be subject to change without notic for purpose of improvement.

    5,130 5,13017,504 17,504

    - 5,250- 17,914

    2,000 2,050- 1,750

    9.5 9.8- 8.0

    2.57 2.508.75 8.54

    3 3- 3.0096% 95%

    - 99%4,500 4,450

    15,355 15,1842,300 2,45011.0 11.51.96 1.826.68 6.20

    95.04 96.842,564 2,515

    - 2,10012.00 12.0

    - 9.697.12 95.27

    - 99.431/220/60 1/220/60

    13.0 (459) 13.0 (459)33 (1165) 48 (1,695)

    1.8 240 4037 3734 3454 56

    R22 R22720 1000

    ROTARY ROTARYQJ278KCF QJ278KCF

    LG LG5,744(19,600) 5,744(19,600)

    PSC PSC1,867 1,867

    4GSI or NM56 4GSI or NM56500 500

    INTERNAL INTERNALCross Flow Fan Cross Flow Fan

    20.6 20.6Axial fan Axial fan

    AC Induction AC Induction41 63.620 20

    3x1.5 3x1.53x1.5 3x1.5+2x0.75

    6.35(1/4") 6.35(1/4")15.88(5/8") 15.88(5/8")

    5(196) 5(196)

    21.5,16 (0.85,0.63) 21.5,16 (0.85,0.63)1090*300*180 1090*300*18042.9*11.8*7.09 42.9*11.8*7.09

    770*540*245 870*655*32030.3*21.3*9.7 34.25*25.79*12.6

    11.5(25.4) 11.5(25.4)34(75.0) 45,5(100.3)S5+UL S5+UE

    21~54(69.8~129.2) 21~54(69.8~129.2)- 1~24(33.8~75.2)

    15(49.2) 15(49.2)10(33) 10(33)

    1 1Auto AutoAuto AutoAuto AutoAuto Auto3/4/- 3/4/3Yes YesYes YesYes Yes

    - -- -

    Yes Yes- YesYes YesYes Yes

    18 - 30 18 - 30- 16 - 30- Yes

    Yes YesYes -Yes YesYes YesYes Yes

    18-30 18-30- 16-301 1

    Yes (24h On/Off) Yes (24h On/Off)- -

    Yes(Type2) Yes(Type2)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    15/65

    15

    Specifications SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Note:O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.

    Some of functions are slightly different depending upon models.The specification may be subject to change without notic for purpose of improvement.

    Model Name (LG) GS-C2425SA3 GS-H2425SA3Pet Name Smart Smart

    Cooling Capacity (T1) WBtu/h.

    Heating Capacity (H1) WBtu/h.

    Power Input Normal Cooling WHeating WRunning Current(Normal)

    Cooling AHeating A

    EERW/W

    Btu/h.W

    (STAR)COP W/W

    Power Factor Cooling %Heating %

    Cooling Capacity (T3) WBtu/h.Power Input (T3) WRunning Current (T3) A

    EER W/WBtu/h.WPower Factor %

    Power Input (Max) Cooling WHeating WRunning Current(Max)

    Cooling AHeating A

    Power Factor Cooling %Heating %Power Supply / V / Hz

    Air Circulation Indoor m3/min(CFM),Max

    Outdoor m3/min(CFM),MaxMoisture Removal l / h.

    Noise Level(SoundPressure,1m)

    IndoordB(A)+3,HighdB(A)+3,MeddB(A)+3,Low

    Outdoor dB(A)+3,MaxRefrigerant Charge Typeg

    Compressor

    TypeModelMakerCapacity kcal/h.(Btu/h.)Motor TypeMotor Input WOil TypeOil Charge ccO.L.P Name

    Blower Motor TypeOutput W

    Fan MotorTypeMotor TypeMotor Output W

    Circuit Breaker APower Cord AWG#:P*mm2Connecting Cable AWG#:P*mm2

    Connecting Tube( . Socket Flare)

    Liquid Side mm(in)Gas Side mm(in)Length,std m(in)

    Drain Hose (O.D , I.D) mm(in)

    Dimension

    Indoor(W*H*D)

    mminch

    Outdoor(W*H*D)

    mminch

    Net Weight Indoor kg(lbs)Outdoor kg(lbs)Tool Code In+Out

    Operation Range Cooling(Outdoor) C(F)Heating(Outdoor) C(F)Max. Piping Length m(ft)Max. Elevation Difference m(ft)

    Functions

    Air flow

    Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan/cool/heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)

    Air purifyingDeodorizing filter (Allergy & H1N1 Filter)Plasma air purifier

    Prefilter(Dual Protection Filter)Reliability

    Hot startSelf diagnosisSoft dry operation

    Convenience

    Setting Temperature, CoolingSetting Temperature, HeatingAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationForced operationSleep modeSetting Temperature Range (Cooling)Setting Temperature Range (Heating)Temperature IncrementTimer(Hr)

    Individual control Wireless remote controller(simple)Wireless LCD remote control

    6,450 6,30022,008 21,496

    - 6,650- 22,691

    2,500 2,700- 2,600

    11.6 12.6- 12.0

    2.58 2.338.80 7.96

    3 2- 2.5698% 97%

    - 98%5,600 5,400

    19,108 18,4263,000 3,25013.9 15.21.87 1.666.37 5.67

    98.10 97.193,400 3,350

    - 3,04016.0 15.7

    - 14.096.59 96.99

    - 98.701/220/60 1/220/6015.0(530) 15.0 (530)48 (1,695) 48 (1,695)

    2.8 2.844 4440 4036 3656 56

    R22 R22900 1700

    ROTARY ROTARYQP362KBB QP362KBB

    LG LG7,911(27,000) 7,911(27,000)

    PSC PSC2,571 2,571

    4GSI or NM56 4GSI or NM56700 700

    INTERNAL INTERNALCross Flow Fan Cross Flow Fan

    30 30Axial fan Axial fan

    AC Induction AC Induction63.6 63.630 30

    3x2.5 3x2.53x2.5 3x2.5+2x0.75

    9.52(3/8") 9.52(3/8")15.88(5/8") 15.88(5/8")

    5(196) 5(196)21.5,16 (0.85,0.63) 21.5,16 (0.85,0.63)

    1090*300*180 1090*300*18042.9*11.8*7.09 42.9*11.8*7.09870*655*320 870*655*320

    34.25*25.79*12.6 34.25*25.79*12.612.0(26.5) 12.0(26.5)42,0(92.6) 50,5(111.3)

    S5+UE S5+UE21~54(69.8~129.2) 21~54(69.8~129.2)

    - 1~24(33.8~75.2)15(49.2) 15(49.2)10(33) 10(33)

    1 1Manual Manual

    Auto AutoManual Manual

    Auto Auto-/4/- -/4/3Yes YesYes YesYes Yes

    - -- -

    Yes Yes- YesYes YesYes Yes

    18 - 30 18 - 30- 16 - 30- -- -- -

    Yes YesYes YesYes Yes

    18-30 18-30- 16-301 1

    Yes (7h Off) Yes (24h Off)Yes(Type3) Yes(Type3)

    - -

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    16/65

    16

    Specifications SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model Name (LG) GS-C2425NB2 GS-H2425NB2Pet Name Fresh Fresh

    Cooling Capacity (T1) WBtu/h.

    Heating Capacity (H1) WBtu/h.

    Power Input Normal Cooling WHeating WRunning Current(Normal)

    Cooling AHeating A

    EERW/W

    Btu/h.W

    (STAR)COP W/W

    Power Factor Cooling %Heating %

    Cooling Capacity (T3) WBtu/h.Power Input (T3) WRunning Current (T3) A

    EER W/WBtu/h.WPower Factor %

    Power Input (Max) Cooling WHeating WRunning Current(Max)

    Cooling AHeating A

    Power Factor Cooling %Heating %Power Supply / V / Hz

    Air Circulation Indoor m3/min(CFM),Max

    Outdoor m 3/min(CFM),MaxMoisture Removal l / h.

    Noise Level(SoundPressure,1m)

    IndoordB(A)+3,HighdB(A)+3,MeddB(A)+3,Low

    Outdoor dB(A)+3,Max

    Refrigerant Charge Typeg

    Compressor

    TypeModelMakerCapacity kcal/h.(Btu/h.)Motor TypeMotor Input WOil TypeOil Charge ccO.L.P Name

    Blower Motor TypeOutput W

    Fan MotorTypeMotor TypeMotor Output W

    Circuit Breaker APower Cord AWG#:P*mm 2Connecting Cable AWG#:P*mm 2

    Connecting Tube( . Socket Flare)

    Liquid Side mm(in)Gas Side mm(in)Length,std m(in)

    Drain Hose (O.D , I.D) mm(in)

    Dimension

    Indoor(W*H*D)

    mminch

    Outdoor(W*H*D)

    mminch

    Net Weight Indoor kg(lbs)Outdoor kg(lbs)Tool Code In+Out

    Operation Range Cooling(Outdoor) C(F)Heating(Outdoor) C(F)Max. Piping Length m(ft)Max. Elevation Difference m(ft)

    Functions

    Air flow

    Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan/cool/heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)

    Air purifyingDeodorizing filter (Allergy & H1N1 Filter)Plasma air purifier

    Prefilter(Dual Protection Filter)Reliability

    Hot startSelf diagnosisSoft dry operation

    Convenience

    Setting Temperature, CoolingSetting Temperature, HeatingAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationForced operationSleep modeSetting Temperature Range (Cooling)Setting Temperature Range (Heating)Temperature IncrementTimer(Hr)

    Individual control Wireless remote controller(simple)Wireless LCD remote control

    Note:O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.

    Some of functions are slightly different depending upon models.The specification may be subject to change without notic for purpose of improvement.

    6,450 6,60022,008 22,520

    - 6,850- 23,373

    2,500 2,640- 2,600

    11.6 12.6- 12.0

    2.58 2.508.80 8.53

    3 3- 2.6398% 95%

    - 98%5,600 5,550

    19,108 18,9373,000 3,25013.9 15.21.87 1.716.37 5.83

    98.10 97.193,400 3,350

    - 3,04016.0 15.7

    - 14.096.59 96.99

    - 98.701/220/60 1/220/6015.0(530) 15.0 (530)48 (1,695) 48 (1,695)

    2.8 2.844 4440 4036 3656 56

    R22 R22900 1700

    ROTARY ROTARYQP362KBB QP362KBB

    LG LG7,911(27,000) 7,911(27,000)

    PSC PSC2,571 2,571

    4GSI or NM56 4GSI or NM56700 700

    INTERNAL INTERNALCross Flow Fan Cross Flow Fan

    30 30Axial fan Axial fan

    AC Induction AC Induction63.6 63.630 30

    3x2.5 3x2.53x2.5 3x2.5+2x0.75

    9.52(3/8") 9.52(3/8")15.88(5/8") 15.88(5/8")

    5(196) 5(196)

    21.5,16 (0.85,0.63) 21.5,16 (0.85,0.63)1090*300*180 1090*300*18042.9*11.8*7.09 42.9*11.8*7.09870*655*320 870*655*320

    34.25*25.79*12.6 34.25*25.79*12.612.0(26.5) 12.0(26.5)42,0(92.6) 50,5(111.3)

    S5+UE S5+UE21~54(69.8~129.2) 21~54(69.8~129.2)

    - 1~24(33.8~75.2)15(49.2) 15(49.2)10(33) 10(33)

    1 1Auto AutoAuto AutoAuto AutoAuto Auto3/4/- 3/4/3Yes YesYes YesYes Yes

    - -- -

    Yes Yes- YesYes YesYes Yes

    18 - 30 18 - 30- 16 - 30- Yes

    Yes YesYes -Yes YesYes YesYes Yes

    18-30 18-30- 16-301 1

    Yes (24h On/Off) Yes (24h On/Off)- -

    Yes(Type2) Yes(Type2)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    17/65

    17

    Dimensional Drawings SR-6RMG2-02A

    GENERAL WALL MOUNTED

    2 5 0

    1 0 3 0

    3 2 5 2 1 0

    7 0

    7 0

    6 9

    5 6

    R i g h t r e a r

    p i p

    i n g

    L e f t r e a r

    p i p i n g

    I n s t a l l a t i o n P l a t e

    M e a s u

    r i n g T a p e

    M e a s u

    r i n g T a p e

    H a n g e r

    P l a c e a l e v

    e l o n r a i s e d t a b

    U n i t O u

    t l i n e

    2 0 7

    1 0 5

    ( U n i

    t : m m

    )

    4 6 0

    5 7 0

    L i b e r o

    R / E

    C H A S S I S C O D E : S

    C

    4

    5. Dimensional Drawings5.1 Indoor Unit

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    18/65

    18

    Dimensional Drawings SR-6RMG2-02A

    GENERAL WALL MOUNTED

    C H A S S I S C O D E :

    S 5

    1 0 9 0

    1 8 0

    1 7 8

    3

    3 0 0

    2

    3 0 0

    5 3

    4 8 . 5

    5

    4

    5 6 7 . 5

    1 0 7

    2 5 - 5

    2 8 . 5

    3 4 5

    5 0 5 0 x

    6 =

    3 0 0

    5

    7 6 . 6

    8 2 . 6

    1 8 0 3 5

    5 0

    1 1 7 . 6

    5 3 . 2

    2 - R 1 6

    1

    W A L L M O U

    N T E D

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    19/65

    19

    Dimensional Drawings SR-6RMG2-02A

    GENERAL WALL MOUNTED

    A R T C O O L M i r r o r

    D i s p l a y

    & s i g n a l r e c e

    i v e r

    P a r

    t N a m e

    F r o n

    t p a n e l

    A i r s u c t

    i o n g r

    i l l e

    I n s t a l

    l a t i o n p l a t e

    K n o c k o u

    t h o l e

    F o r p

    i p e a n

    d c a

    b l e

    5

    N o . 2 4 3 1

    R e m a r

    k

    N o t e

    9 1 2

    5 0

    5 0 * 6 = 3

    0 0

    3 5 4

    5 6 7

    2 8

    7 1 7 7

    1 4 8

    1 0 7

    2 8 2

    2 8 2

    5 1

    5 3

    5 0 3 7

    5 1

    2 - R 1 6

    5

    1 6 5

    2

    4

    1 7 1

    3

    1 . U n i t s h o u

    l d b e i n s t a l

    l e d i n c o m p l

    i a n c e w

    i t h t h e

    i n s t a

    l l a t i o n m a n u a

    l

    i n t h e p r o d u c

    t b o x .

    2 . U n i t s h a l

    l b e g r o u n d e d

    i n a c c o r d a n c e w

    i t h t h e

    l o c a l r e g u

    l a t i o n s o r

    a p p

    l i c a b

    l e n a

    t i o n a

    l c o d e s .

    3 . T h e U n i

    t i s p o w e r e d

    f r o m

    t h e o u

    t d o o r u n

    i t . T h e r e

    f o r e p o w e r c a

    b l e

    s h o u

    l d b e c o n n e c

    t e d w

    i t h t h e o u

    t d o o r u n

    i t .

    1

    C H A S S I S C O D E : S

    E

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    20/65

    20

    Dimensional Drawings SR-6RMG2-02A

    GENERAL WALL MOUNTED

    5.2 Outdoor Unit

    1

    G a s

    P i p e

    C o n n e c t

    i o n

    P o r

    t

    P a r

    t N a m e

    A i r D i c h a r g e

    G r i l

    l e

    L i q u

    i d P i p e

    C o n n e c t

    i o n

    P o r

    t

    C o n

    t r o l

    B o x

    N o . 2 4

    E a r

    t h S c r e w

    5 3 1

    R e m a r

    k

    N o t e

    1 . T h e u n

    i t s h o u

    l d b e i n s t a l

    l e d a c c o r d

    i n g

    t o i n s t a l

    l a t i o n m a n u a

    l w h i c h

    i s

    i n t h e p r o

    d u c t

    b o x .

    2 . I n a n a r e a o r a a p a c e

    h a v i n g n o p r o p e r a i r c

    i r c u l a t

    i o n , a n a i r g u i

    d e

    s h o u

    l d b e i n s t a l

    l e d i n t h e o u

    t d o o r u n

    i t .

    7 6 , S

    e o n g s a n -

    d o n g , C

    h a n g w o n

    C i t y

    , G y e o n g n a m ,

    6 4 1 - 7 1 3 , K o r e a

    w w w . l g

    e . c o m

    / a i r c o n

    d i t i o n e r

    C H A S S I S C

    O D E : U

    E

    O u t

    d o o r U n i

    t

    U n i

    t : m m

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    21/65

    21

    Dimensional Drawings SR-6RMG2-02A

    GENERAL WALL MOUNTED

    C H A S S I S

    C O D E :

    U L

    5 4 0

    1 0

    6 5 4 . 3

    7 7 0

    4 5

    0

    2 7 5

    4 5 0

    2 6 1

    5

    2 3

    5 5 . 3

    4

    2 4 5

    1

    5 6

    2 4 5

    2 8 5

    7 7 0

    5 1 8 . 4

    2 6 7

    O u t

    d o o r

    U n i t

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    22/65

    22

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    6. Wiring Diagrams6.1 Indoor Units

    CN-MOTOR

    CN-U/D

    CN-L/R

    CN-OPTION

    CN-DISP3

    CN-HVB

    CN-12V

    CN-TH1

    CN-DISP2

    CN-SUB

    Model : GS-C182C4B2, GS-C242C4B2

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    23/65

    23

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-H182C4B2, GS-H242C4B2

    CN-U/D

    CN-L/R

    CN-DISP3

    CN-SUB

    CN-OPTION

    CN-HVB

    CN-12V

    CN-TH1

    CN-DISP2

    CN-4WAY

    CN-MOTOR

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    24/65

    24

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-H1825SA3, GS-H2425SA3, GS-H1825NB2, GS-H2425NB2 , GS-H122E5B2

    MOTOROR

    RDB%

    B% B%B% B%

    P O W E R

    GN/YL

    GN/YL

    B R ( B % / P l a i n e d )

    B L ( W H / R i b b e d ) B%

    YL

    SH-CAPA

    TERMINALBLOC%

    RY-4WAY

    RY-FAN

    CN-MOTOR

    THERMISTOR

    OPTIONPWB ASM.

    STEPMOTOR

    C N

    - T H 1

    C N

    - U / D C N

    - O P T I O N

    C N

    - L / R

    C N - H

    V B

    C N - 1

    2 V

    C N

    - D I S P 1

    DISPLAY

    PWB ASM.

    P/No : 3854A20427B

    TRIAC

    MAIN PWB ASM.

    CN-N1

    CN-N2

    CN-4WAY

    RY-COMP

    TO OUTDOOR UNIT

    4 31

    ( L )

    BR

    B R B

    L B %

    R D

    G N / Y L

    2 ( N )

    3

    4

    1 ( L )

    2 ( N )

    3

    4

    FUSE250V T2A

    STEPMOTOR

    H.V.ASM.

    S/W1

    AIRCLEAN(PLASMA)

    C N

    - D I S P 2

    CONDUCTIVE

    ENCLOSUREMOTOR ONLY

    CN-L/R CN-U/D CN-HVB CN-DISP2

    CN-DISP1

    CN-OPTION

    CN-12V

    CN-MOTOR

    CN-TH1

    CN-N1

    CN-N2

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    25/65

    25

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-C1825SA3 GS-C2425SA3 GS-C1825NB2 GS-C2425NB2 GS-C122E5B2

    CN-MOTOR

    CN-N1

    CN-N2CN-DISP2(BL)

    CN-L/R(BL)

    CN-U/D(WH)

    CN-HVB(BL)

    CN-DISP1(WH)

    CN-TH1(WH)

    CN-12V(YL)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    26/65

    26

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    CapacitorTerminal Block

    Model : GS-C122E5B2

    6.2 Outdoor Unit

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    27/65

    27

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Capacitor

    Terminal Block

    Model : GS-H122E5B2

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    28/65

    28

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    CapacitorTerminal Block

    Model : GS-C1825SA3, GS-C1825NB2

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    29/65

    29

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    CapacitorTerminal Block

    Model : GS-H1825SA3, GS-H2425SA3, GS-H1825NB2, GS-H2425NB2, GS-H182C4B2, GS-H242C4B2

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    30/65

    30

    Wiring Diagrams SR-6RMG2-02A

    GENERAL WALL MOUNTED

    CapacitorTerminal Block

    Model : GS-C2425SA3, GS-C2425NB2, GS-C182C4B2, GS-C242C4B2

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    31/65

    31

    Refrigerant Cycle Diagram SR-6RMG2-02A

    GENERAL WALL MOUNTED

    7. Refrigerant Cycle Diagram

    INDOOR UNIT OUTDOOR UNIT

    HEATE CHANGE(EVAPORATOR)

    HEATE CHANGE(CONDENSER)

    COMPRESSORGAS SIDE

    LIQUID SIDE

    CAPILLARY TUBE

    rotcennoCBCPnoitpircseD.COL

    Th1 Thermistor for indoor air temperatureCN-TH1

    Th2 Thermistor for evaporating temperature

    INDOOR UNIT OUTDOOR UNIT

    HEATE CHANGE(EVAPORATOR)

    HEATE CHANGE(CONDENSER)

    COMPRESSOR

    ACCUMU%LATOR

    GAS SIDE

    3-WAY VALVE

    LIQUID SIDE

    3-WAY VALVE

    CAPILLARY TUBE

    CHEC VALVE(Heating Model only)

    COOLINGHEATING

    REVERSINGVALVE(Heating Model Only)

    Model : GS-C122*, GS-C182*, GS-C242*

    Model : GS-H122*, GS-H182*, GS-H242*

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    32/65

    32

    Capacity Tables SR-6RMG2-02A

    GENERAL WALL MOUNTED

    8. Capacity Tables

    Model : GS-C182C4B2

    Model : GS-H182C4B2

    Model : GS-C242C4B2

    Cooling capacity

    CWB CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 20 4.40 3.41 1.30 4.30 3.37 1.55 4.10 3.28 1.80 3.98 3.21 1.90 3.83 3.14 2.02 3.74 3.10 2.09

    16 22 5.13 3.87 1.32 5.02 3.83 1.57 4.79 3.72 1.83 4.64 3.64 1.93 4.47 3.55 2.05 4.37 3.50 2.1218 25 5.73 4.21 1.34 5.60 4.16 1.59 5.34 4.03 1.86 5.18 3.94 1.96 4.99 3.84 2.08 4.87 3.78 2.1519 27 5.99 4.35 1.37 5.86 4.30 1.62 5.59 4.16 1.89 5.42 4.07 1.99 5.22 3.96 2.12 5.10 3.90 2.1922 30 6.58 4.61 1.38 6.44 4.55 1.64 6.13 4.40 1.91 5.95 4.29 2.02 5.73 4.18 2.14 5.60 4.10 2.2124 32 6.82 4.69 1.40 6.68 4.62 1.66 6.37 4.46 1.94 6.17 4.35 2.04 5.95 4.23 2.17 5.81 4.15 2.25

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20 25 32 35 40 43

    CWB CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 20 4.40 3.36 1.30 4.30 3.33 1.55 4.10 3.24 1.80 3.98 3.17 1.90 3.83 3.10 2.02 3.74 3.06 2.09

    16 22 5.13 3.82 1.32 5.02 3.78 1.57 4.79 3.67 1.83 4.64 3.59 1.93 4.47 3.50 2.05 4.37 3.45 2.1218 25 5.73 4.15 1.34 5.60 4.10 1.59 5.34 3.98 1.86 5.18 3.89 1.96 4.99 3.79 2.08 4.87 3.73 2.1519 27 5.99 4.29 1.37 5.86 4.24 1.62 5.59 4.11 1.89 5.42 4.01 1.99 5.22 3.91 2.12 5.10 3.85 2.1922 30 6.58 4.55 1.38 6.44 4.49 1.64 6.13 4.34 1.91 5.95 4.24 2.02 5.73 4.12 2.14 5.60 4.05 2.2124 32 6.82 4.63 1.40 6.68 4.56 1.66 6.37 4.40 1.94 6.17 4.29 2.04 5.95 4.17 2.17 5.81 4.10 2.25

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20 25 32 35 40 43

    CWB CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 20 5.70 4.18 1.77 5.58 4.14 2.10 5.32 4.03 2.44 5.16 3.95 2.58 4.97 3.86 2.74 4.86 3.81 2.83

    16 22 6.66 4.75 1.80 6.52 4.70 2.13 6.21 4.56 2.48 6.02 4.47 2.62 5.80 4.36 2.78 5.66 4.29 2.8718 25 7.43 5.16 1.82 7.27 5.11 2.16 6.93 4.95 2.52 6.72 4.84 2.66 6.47 4.72 2.82 6.32 4.64 2.9219 27 7.77 5.34 1.85 7.61 5.28 2.20 7.25 5.11 2.56 7.03 4.99 2.70 6.77 4.87 2.87 6.62 4.79 2.9722 30 8.53 5.66 1.88 8.35 5.59 2.23 7.96 5.40 2.60 7.72 5.27 2.73 7.43 5.13 2.91 7.26 5.04 3.0024 32 8.85 5.76 1.91 8.67 5.68 2.26 8.26 5.48 2.63 8.01 5.35 2.77 7.71 5.19 2.95 7.53 5.10 3.05

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20 25 32 35 40 43

    SymbolDB : Dry bulb temperature [C]WB : Wet bulb temperature [C]TC : Total capacity [kW]SHC : Sensible capacity [kW]PI : Power Input [kW]

    (Comp.+ indoor fan motor+outdoor fan motor)

    Notes1. All capacites are net, evaporator fan motor heat is deducted.2. Indicates nominal capacity.3. Direct interpolation is permissible. Do not extrapolate4. Capacities are based on the following conditions:

    - Interconnecting Piping Length 7.5m- Level Difference of Zero.

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    33/65

    33

    Capacity Tables SR-6RMG2-02A

    GENERAL WALL MOUNTED

    SymbolDB : Dry bulb temperature [C]WB : Wet bulb temperature [C]TC : Total capacity [kW]SHC : Sensible capacity [kW]PI : Power Input [kW]

    (Comp.+ indoor fan motor+outdoor fan motor)

    Notes1. All capacites are net, evaporator fan motor heat is deducted.2. Indicates nominal capacity.3. Direct interpolation is permissible. Do not extrapolate4. Capacities are based on the following conditions:

    - Interconnecting Piping Length 7.5m- Level Difference of Zero.

    Model : GS-H242C4B2

    CWB CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 20 5.70 4.24 1.87 5.58 4.20 2.21 5.32 4.09 2.58 5.16 4.00 2.72 4.97 3.92 2.89 4.86 3.86 2.99

    16 22 6.66 4.82 1.90 6.52 4.77 2.25 6.21 4.63 2.62 6.02 4.53 2.76 5.80 4.42 2.94 5.66 4.35 3.0318 25 7.43 5.24 1.93 7.27 5.18 2.28 6.93 5.02 2.66 6.72 4.91 2.80 6.47 4.78 2.98 6.32 4.71 3.0819 27 7.77 5.41 1.96 7.61 5.35 2.32 7.25 5.18 2.71 7.03 5.06 2.85 6.77 4.93 3.03 6.62 4.85 3.1322 30 8.53 5.74 1.98 8.35 5.67 2.35 7.96 5.48 2.74 7.72 5.35 2.89 7.43 5.20 3.07 7.26 5.11 3.1724 32 8.85 5.84 2.01 8.67 5.76 2.38 8.26 5.56 2.78 8.01 5.42 2.93 7.71 5.27 3.11 7.53 5.17 3.22

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20 25 32 35 40 43

    Model : GS-C122E5B2

    Model : GS-H122E5B2

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    2.86 0.79 2.79 0.93 2.66 1.09 2.58 1.14 2.49 1.22 2.41 1.26 2.29 1.34 2.12 1.373.33 0.80 3.26 0.95 3.11 1.10 3.01 1.16 2.90 1.24 2.81 1.28 2.66 1.36 2.46 1.383.72 0.81 3.64 0.96 3.47 1.12 3.36 1.18 3.24 1.26 3.13 1.30 2.98 1.37 2.77 1.403.89 0.82 3.81 0.98 3.63 1.14 3.52 1.20 3.39 1.28 3.28 1.32 3.11 1.40 2.88 1.434.27 0.83 4.18 0.99 3.98 1.15 3.86 1.22 3.72 1.29 3.60 1.34 3.41 1.42 3.17 1.454.43 0.85 4.34 1.00 4.13 1.17 4.01 1.23 3.86 1.31 3.73 1.35 3.54 1.44 3.28 1.47

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    2.73 0.79 2.68 0.93 2.55 1.09 2.47 1.14 2.38 1.22 2.30 1.26 2.20 1.34 2.04 1.373.19 0.80 3.12 0.95 2.98 1.10 2.89 1.16 2.78 1.24 2.69 1.28 2.56 1.36 2.37 1.383.56 0.81 3.49 0.96 3.32 1.12 3.22 1.18 3.10 1.26 3.00 1.30 2.87 1.37 2.66 1.403.73 0.82 3.65 0.98 3.48 1.14 3.37 1.20 3.25 1.28 3.14 1.32 2.99 1.40 2.77 1.434.09 0.83 4.00 0.99 3.81 1.15 3.70 1.22 3.56 1.29 3.45 1.34 3.28 1.42 3.05 1.454.24 0.85 4.15 1.00 3.96 1.17 3.84 1.23 3.70 1.31 3.58 1.35 3.40 1.44 3.16 1.47

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    34/65

    34

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-C1825SA3, GS-C1825NB2

    Model : GS-H1825SA3

    Symbol

    DB : Dry bulb temperature [C]WB : Wet bulb temperature [C]TC : Total capacity [kW]SHC : Sensible capacity [kW]PI : Power Input [kW]

    (Comp.+ indoor fan motor+outdoor fan motor)

    Notes

    1. All capacites are net, evaporator fan motor heat is deducted.2. Indicates nominal capacity.3. Direct interpolation is permissible. Do not extrapolate4. Capacities are based on the following conditions:

    - Interconnecting Piping Length 7.5m- Level Difference of Zero.

    Model : GS-H1825NB2

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    4.16 1.31 4.07 1.55 3.88 1.81 3.76 1.91 3.62 2.03 3.51 2.10 3.30 2.20 3.06 2.244.85 1.33 4.75 1.58 4.53 1.84 4.39 1.94 4.23 2.06 4.09 2.13 3.83 2.23 3.56 2.275.42 1.35 5.30 1.60 5.05 1.87 4.90 1.97 4.72 2.09 4.56 2.16 4.31 2.26 4.00 2.315.67 1.37 5.55 1.63 5.29 1.90 5.13 2.00 4.94 2.13 4.78 2.20 4.48 2.30 4.16 2.356.22 1.39 6.09 1.65 5.80 1.92 5.63 2.03 5.42 2.15 5.24 2.23 4.93 2.33 4.57 2.386.46 1.41 6.32 1.67 6.02 1.95 5.84 2.06 5.63 2.19 5.44 2.26 5.10 2.36 4.73 2.41

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    4.05 1.38 3.96 1.63 3.78 1.90 3.66 2.00 3.53 2.13 3.41 2.20 3.15 2.34 2.92 2.394.72 1.40 4.62 1.66 4.40 1.93 4.27 2.03 4.11 2.16 3.98 2.23 3.66 2.37 3.39 2.425.27 1.42 5.16 1.68 4.91 1.96 4.77 2.07 4.59 2.20 4.44 2.27 4.11 2.41 3.81 2.465.51 1.44 5.40 1.71 5.14 1.99 4.99 2.10 4.80 2.23 4.65 2.31 4.28 2.45 3.97 2.506.05 1.46 5.92 1.73 5.64 2.02 5.48 2.13 5.27 2.26 5.10 2.34 4.70 2.48 4.36 2.546.28 1.48 6.15 1.76 5.86 2.05 5.68 2.16 5.47 2.30 5.29 2.37 4.87 2.52 4.52 2.57

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    4.16 1.34 4.07 1.59 3.88 1.86 3.76 1.96 3.62 2.08 3.51 2.15 3.26 2.34 3.02 2.394.85 1.36 4.75 1.62 4.53 1.88 4.39 1.99 4.23 2.11 4.09 2.18 3.78 2.37 3.51 2.425.42 1.38 5.30 1.64 5.05 1.91 4.90 2.02 4.72 2.14 4.56 2.21 4.25 2.41 3.94 2.465.67 1.41 5.55 1.67 5.29 1.95 5.13 2.05 4.94 2.18 4.78 2.25 4.43 2.45 4.10 2.506.22 1.43 6.09 1.69 5.80 1.97 5.63 2.08 5.42 2.21 5.24 2.28 4.86 2.48 4.51 2.546.46 1.45 6.32 1.71 6.02 2.00 5.84 2.11 5.63 2.24 5.44 2.31 5.04 2.52 4.67 2.57

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    35/65

    35

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-C2425SA3, GS-C2425NB2

    Model : GS-H2425SA3

    Model : GS-H2425NB2

    Symbol

    DB : Dry bulb temperature [C]WB : Wet bulb temperature [C]TC : Total capacity [kW]SHC : Sensible capacity [kW]PI : Power Input [kW]

    (Comp.+ indoor fan motor+outdoor fan motor)

    Notes

    1. All capacites are net, evaporator fan motor heat is deducted.2. Indicates nominal capacity.3. Direct interpolation is permissible. Do not extrapolate4. Capacities are based on the following conditions:

    - Interconnecting Piping Length 7.5m- Level Difference of Zero.

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    5.23 1.64 5.12 1.94 4.88 2.26 4.73 2.38 4.56 2.54 4.41 2.62 4.12 2.86 3.83 2.936.10 1.66 5.97 1.97 5.69 2.30 5.52 2.42 5.32 2.58 5.14 2.66 4.79 2.91 4.44 2.976.81 1.69 6.67 2.00 6.35 2.33 6.16 2.46 5.93 2.61 5.74 2.70 5.38 2.95 4.99 3.017.13 1.72 6.98 2.04 6.65 2.37 6.45 2.50 6.21 2.66 6.01 2.75 5.60 3.00 5.19 3.067.82 1.74 7.66 2.06 7.30 2.40 7.08 2.53 6.82 2.69 6.59 2.78 6.15 3.04 5.70 3.118.12 1.76 7.95 2.09 7.57 2.44 7.35 2.57 7.07 2.73 6.84 2.82 6.37 3.08 5.91 3.15

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    5.11 1.77 5.00 2.10 4.77 2.44 4.62 2.58 4.45 2.74 4.31 2.83 3.97 3.10 3.69 3.175.96 1.80 5.84 2.13 5.56 2.48 5.39 2.62 5.19 2.78 5.02 2.87 4.61 3.15 4.28 3.216.65 1.82 6.51 2.16 6.20 2.52 6.02 2.66 5.80 2.82 5.61 2.92 5.18 3.19 4.80 3.266.96 1.85 6.81 2.20 6.49 2.56 6.30 2.70 6.07 2.87 5.87 2.97 5.39 3.25 5.00 3.327.64 1.88 7.48 2.23 7.13 2.60 6.91 2.73 6.66 2.91 6.44 3.00 5.92 3.29 5.50 3.367.93 1.91 7.76 2.26 7.40 2.63 7.17 2.77 6.91 2.95 6.68 3.05 6.14 3.34 5.69 3.41

    Indoor AirTemperature

    Outdoor Air Temperature : CDB20.0 25.0 32.0 35.0 40.0 43.0 46.1 57.1

    CWB CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI14 2016 2218 2519 2722 3024 32

    5.35 1.73 5.24 2.05 4.99 2.39 4.84 2.52 4.66 2.68 4.51 2.77 4.08 3.08 3.79 3.156.25 1.76 6.11 2.08 5.83 2.43 5.65 2.56 5.44 2.72 5.26 2.81 4.74 3.13 4.39 3.196.97 1.78 6.82 2.11 6.50 2.46 6.31 2.60 6.07 2.76 5.87 2.85 5.32 3.17 4.94 3.247.29 1.81 7.14 2.15 6.80 2.51 6.60 2.64 6.35 2.81 6.15 2.90 5.54 3.23 5.14 3.308.00 1.84 7.83 2.18 7.47 2.54 7.24 2.67 6.97 2.84 6.75 2.94 6.09 3.27 5.65 3.348.31 1.86 8.13 2.21 7.75 2.58 7.52 2.71 7.24 2.89 7.00 2.98 6.30 3.32 5.85 3.39

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    36/65

    36

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-H122E5B2

    CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI

    16 2.38 0.84 2.80 0.92 3.24 1.00 3.40 1.03 3.56 1.06 3.77 1.08 4.08 1.13 4.50 1.22

    18 2.30 0.87 2.71 0.95 3.14 1.03 3.29 1.06 3.45 1.10 3.65 1.11 3.95 1.17 4.36 1.26

    20 2.23 0.90 2.63 0.98 3.04 1.07 3.20 1.10 3.35 1.13 3.52 1.15 3.83 1.21 4.23 1.30

    22 2.15 0.92 2.54 1.01 2.93 1.10 3.08 1.13 3.23 1.17 3.41 1.19 3.69 1.25 4.08 1.34

    24 2.08 0.95 2.45 1.04 2.83 1.13 2.98 1.17 3.12 1.20 3.29 1.22 3.57 1.29 3.94 1.38

    Indoor AirTemperature

    Outdoor Air Temperature : CWB-10 -5 0 2 4 6 10 15

    Model : GS-H182C4B2

    Model : GS-H242C4B2

    CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI

    16 3.86 1.34 4.55 1.47 5.26 1.60 5.52 1.65 5.79 1.70 6.12 1.72 6.62 1.82 7.31 1.94

    18 3.74 1.39 4.40 1.52 5.09 1.65 5.35 1.70 5.60 1.75 5.92 1.78 6.41 1.88 7.08 2.01

    20 3.63 1.43 4.27 1.57 4.94 1.71 5.19 1.76 5.44 1.81 5.71 1.84 6.22 1.94 6.86 2.08

    22 3.49 1.48 4.12 1.62 4.76 1.76 5.00 1.81 5.24 1.87 5.54 1.90 5.99 2.00 6.62 2.14

    24 3.37 1.52 3.98 1.67 4.60 1.81 4.83 1.87 5.06 1.93 5.35 1.96 5.79 2.06 6.39 2.21

    Indoor AirTemperature

    Outdoor Air Temperature : CWB-10 -5 0 2 4 6 10 15

    CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI

    16 5.14 2.02 6.06 2.21 7.01 2.40 7.36 2.48 7.72 2.55 8.15 2.60 8.83 2.73 9.74 2.93

    18 4.98 2.09 5.87 2.28 6.79 2.49 7.13 2.56 7.47 2.64 7.90 2.68 8.55 2.83 9.43 3.03

    20 4.83 2.16 5.69 2.36 6.59 2.57 6.92 2.65 7.25 2.73 7.62 2.77 8.29 2.92 9.15 3.13

    22 4.66 2.23 5.49 2.43 6.35 2.65 6.67 2.73 6.99 2.81 7.38 2.86 7.99 3.01 8.82 3.23

    24 4.50 2.29 5.30 2.51 6.13 2.73 6.44 2.81 6.75 2.90 7.13 2.95 7.72 3.10 8.52 3.32

    Indoor AirTemperature

    Outdoor Air Temperature : CWB-10 -5 0 2 4 6 10 15

    SymbolDB : Dry bulb temperature [C]WB : Wet bulb temperature [C]TC : Total capacity [kW]SHC : Sensible capacity [kW]PI : Power Input [kW]

    (Comp.+ indoor fan motor+outdoor fan motor)

    Notes1. All capacites are net, evaporator fan motor heat is deducted.2. Indicates nominal capacity.3. Direct interpolation is permissible. Do not extrapolate4. Capacities are based on the following conditions:

    - Interconnecting Piping Length 7.5m- Level Difference of Zero.

    Heating capacity

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    37/65

    37

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-H1825SA3

    CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI 16 3.44 1.28 4.05 1.39 4.69 1.52 4.93 1.57 5.16 1.61 5.45 1.64 5.90 1.73 6.52 1.85

    18 3.33 1.32 3.93 1.44 4.54 1.57 4.77 1.62 5.00 1.67 5.28 1.70 5.72 1.79 6.31 1.91

    20 3.23 1.36 3.81 1.49 4.41 1.62 4.63 1.67 4.85 1.72 5.09 1.75 5.55 1.84 6.12 1.97

    22 3.12 1.41 3.67 1.54 4.25 1.67 4.46 1.72 4.67 1.78 4.94 1.81 5.35 1.90 5.90 2.04

    24 3.01 1.45 3.55 1.58 4.10 1.73 4.31 1.78 4.51 1.83 4.77 1.86 5.16 1.96 5.70 2.10

    Indoor AirTemperature

    Outdoor Air Temperature : CWB-10 -5 0 2 4 6 10 15

    Model : GS-H1825NB2

    CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI

    16 3.54 1.28 4.18 1.39 4.83 1.52 5.07 1.57 5.32 1.61 5.62 1.64 6.08 1.73 6.71 1.85

    18 3.43 1.32 4.04 1.44 4.68 1.57 4.91 1.62 5.15 1.67 5.44 1.70 5.89 1.79 6.50 1.91

    20 3.33 1.36 3.92 1.49 4.54 1.62 4.77 1.67 5.00 1.72 5.25 1.75 5.71 1.84 6.31 1.97

    22 3.21 1.41 3.78 1.54 4.38 1.67 4.59 1.72 4.81 1.78 5.09 1.81 5.51 1.90 6.08 2.04

    24 3.10 1.45 3.65 1.58 4.22 1.73 4.44 1.78 4.65 1.83 4.91 1.86 5.32 1.96 5.87 2.10

    Indoor AirTemperature

    Outdoor Air Temperature : CWB-10 -5 0 2 4 6 10 15

    Symbol

    DB : Dry bulb temperature [C]WB : Wet bulb temperature [C]TC : Total capacity [kW]SHC : Sensible capacity [kW]PI : Power Input [kW]

    (Comp.+ indoor fan motor+outdoor fan motor)

    Notes

    1. All capacites are net, evaporator fan motor heat is deducted.2. Indicates nominal capacity.3. Direct interpolation is permissible. Do not extrapolate4. Capacities are based on the following conditions:

    - Interconnecting Piping Length 7.5m- Level Difference of Zero.

    Model : GS-H2425SA3

    CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI

    16 4.49 1.90 5.29 2.07 6.12 2.26 6.43 2.33 6.73 2.40 7.12 2.44 7.70 2.57 8.50 2.75

    18 4.35 1.96 5.12 2.14 5.93 2.33 6.22 2.40 6.52 2.48 6.89 2.52 7.46 2.65 8.23 2.84

    20 4.22 2.02 4.97 2.21 5.75 2.41 6.04 2.48 6.33 2.56 6.65 2.60 7.24 2.74 7.99 2.93

    22 4.07 2.09 4.79 2.28 5.54 2.49 5.82 2.56 6.10 2.64 6.44 2.68 6.98 2.83 7.70 3.03

    24 3.93 2.15 4.63 2.35 5.35 2.56 5.62 2.64 5.89 2.72 6.22 2.77 6.74 2.91 7.44 3.12

    Indoor AirTemperature

    Outdoor Air Temperature : CWB-10 -5 0 2 4 6 10 15

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    38/65

    38

    Capacity Tables SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Model : GS-H2425NB2

    CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI

    16 4.63 1.90 5.45 2.07 6.30 2.26 6.62 2.33 6.94 2.40 7.33 2.44 7.93 2.57 8.76 2.75

    18 4.48 1.96 5.28 2.14 6.10 2.33 6.41 2.40 6.72 2.48 7.10 2.52 7.68 2.65 8.48 2.84

    20 4.35 2.02 5.12 2.21 5.92 2.41 6.22 2.48 6.52 2.56 6.85 2.60 7.45 2.74 8.23 2.93

    22 4.19 2.09 4.93 2.28 5.71 2.49 6.00 2.56 6.28 2.64 6.64 2.68 7.19 2.83 7.93 3.03

    24 4.04 2.15 4.76 2.35 5.51 2.56 5.79 2.64 6.07 2.72 6.41 2.77 6.94 2.91 7.66 3.12

    Indoor AirTemperature

    Outdoor Air Temperature : CWB-10 -5 0 2 4 6 10 15

    SymbolDB : Dry bulb temperature [C]WB : Wet bulb temperature [C]TC : Total capacity [kW]SHC : Sensible capacity [kW]PI : Power Input [kW]

    (Comp.+ indoor fan motor+outdoor fan motor)

    Notes1. All capacites are net, evaporator fan motor heat is deducted.2. Indicates nominal capacity.3. Direct interpolation is permissible. Do not extrapolate4. Capacities are based on the following conditions:

    - Interconnecting Piping Length 7.5m- Level Difference of Zero.

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    39/65

    39

    Capacity Coefficient Factor SR-6RMG2-02A

    GENERAL WALL MOUNTED

    9. Capacity Coefficient Factor

    Model: 9 kBtu/h ~ 26 kBtu/h Cooling Only

    Model: 5 kBtu/h ~ 14 kBtu/h Heat Pump

    (A)

    (A)

    Indoor

    Indoor

    Outdoor

    Outdoor

    (A)

    (A)

    Indoor

    Indoor

    Outdoor

    Outdoor

    Classification Height

    (A)

    Capacity Coefficient factorTotal Pipe Length(m)

    5 7.5 10 12.5 15

    - - - (0.94) (0.93)

    - 0.97 0.96 (0.95) (0.94)

    0.99 0.98 0.97 (0.96) (0.95)

    1.0 0.99 0.98 (0.97) (0.96)

    1.0 0.99 0.98 (0.97) (0.96)

    0.99 0.98 0.97 (0.96) (0.95)

    - 0.97 0.96 (0.95) (0.94)

    - - - (0.94) (0.93)

    The values in parentheses are valid only for 18~24kBtu models.

    10

    7

    5

    0

    0

    5

    7

    10

    Classification Height(A)

    Capacity Coefficient factorTotal Pipe Length(m)

    5 7.5 10 12.5 15

    - - - - -

    - 0.97 0.97 - -

    0.99 0.98 0.97 - -

    1.0 0.99 0.98 - -

    1.0 0.99 0.98 - -

    0.99 0.98 0.97 - -

    - 0.97 0.97 - -

    - - - - -

    10

    7

    5

    0

    0

    5

    7

    10

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    40/65

    40

    Operation Range SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Outdoor unit

    Indoor unit

    A

    B

    Outdoor unit

    Indoor unit

    A

    B

    CapacitykW (kBtu/h)

    Pipe Size[mm(in)] StandardLength m(ft)

    Max.Elevation m(ft)

    Max.Length m(ft)

    Additional Refrigerantg/m(oz/ft)GAS LIQUID

    3.5(12) 12.7(1/2) 6.35(1/4) 5(16) 10(33) 15(49) 20(0.22)

    5.3(18) 15.88(5/8) 6.35(1/4) 5(16) 10(33) 15(49) 20(0.22)

    7.0(24) 15.88(5/8) 9.52(3/8) 5(16) 10(33) 15(49) 30(0.32)

    Capacity is based on standard length and maximum allowable length is on the basis of reliability.Additional refrigerant must be charged after 5m.

    CAUTION

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    41/65

    41

    Air Velocity and Temperature Distribution(Reference Data) SR-6RMG2-02A

    GENERAL WALL MOUNTED

    10. Air Velocity and Temperature Distribution(Reference Data)

    Model : GS-C182C4B2, GS-H182C4B2, GS-C1825*,GS-C2425*, GS-H1825*,GS-H2425*

    General Wall Mounted 18/24 kBtu/h

    CoolingDischarge angle:45

    HeatingDischarge angle:50

    Air velocity [m/s]2.7m

    2m

    1m

    0m1m2m3m4m5m6m7m8m

    Temperature [ C]

    2.7m2m

    1m

    0m1m2m3m4m5m6m7m8m

    0.751.25

    1.0

    1.5

    0.5

    25 24

    23

    Air velocity [m/s]2.7m

    2m

    1m

    0m1m2m3m4m5m6m7m8m

    Temperature [C]2.7m

    2m

    1m

    0m1m2m3m4m5m6m7m8m

    0.751.25

    1.0

    1.5

    0.5

    28 29 30

    31

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    42/65

    42

    Controller SR-6RMG2-02A

    GENERAL WALL MOUNTED

    11. ControllerType 1 (Wireless LCD)

    Displayscreen

    Controlpanel

    Display

    screen

    Controlpanel

    JETCOOL

    JETCOOL

    C/F[5SEC]

    C/F[5SEC]

    Control panel Display screen Description

    a F Plasma button*: Purifies the air by removingparticles that enter the indoor unit./ 4 Air circulation button*: Used to circulate theroom air without cooling or heating.l = Sleep mode auto button*: Sets the sleep modeauto operation. e y Temperature adjustment buttons: Adjusts theroom temperature when cooling and heating.d - On/Off button: Turns the power on/off.g 7 v Indoor fan speed button: Adjusts the fanspeed.f A CD B E

    Operation mode selection button*: Selects theoperation mode.Cooling operation (A ) / Auto operation or autochangeover ( C ) / Dehumidifying operation (D) / Heating operation ( B ) / Air circulation (E )

    JETCOOL N

    Jet cooling/heating button*: Warms up or coolsdown the indoor temperature within a short peri-od of time.

    i j H I Air flow direction button: Adjusts the air flowdirection vertically or horizontally.k S Temperature display button: Displays the roomtemperature.

    m n z Timer button: Sets the current time and the start/ end time.cb

    u J G P

    Functions button*: Adjusts the time and setsthe special functions.J : Auto clean / G: Operates energy saving cool-ing / P : Adjusts the brightness of the indoor unit

    displayp - Set/clear button: Sets or cancels functions.r - Reset button: Initialize the air conditioner set-tings.

    * Some functions may not be supported, depending on the model.

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    43/65

    43

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    ON OFF

    CANCEL

    AUTO CLEANSET

    1

    3

    5

    4

    9

    18

    10

    12

    14

    16

    72

    813

    15

    11

    6

    Cooling Operation

    Auto Operation or Auto Changeover

    Healthy Dehumidification Operation

    Flip-up door

    (opened)

    Heating Operation

    Signal transmitter

    Cooling Model( ), Heat Pump Model( )

    1719

    Operation Mode

    1. START/STOP BUTTONUsed to turn off/on the unit.

    2. OPERATION MODE SELECTION BUTTONUsed to select the operation mode.

    3. ROOM TEMPERATURE SETTING BUTTONSUsed to select the room temperature.

    4. INDOOR FAN SPEED SELECTOR BUTTONUsed to select fan speed in four stepslow, medium, high and CHAOS.

    5. JET COOL BUTTONUsed to start or stop the speed cooling.(It operates fan in super high speed in cooling mode)

    6. CHAOS SWING BUTTONUsed to stop or start louver movement and set thedesired up/down airflow direction.

    7. ON/OFF TIMER BUTTONSUsed to set the time of starting and stoppingoperation.

    8. TIME SETTING BUTTONSUsed to adjust the time.

    9. TIMER SET/CANCEL BUTTONUsed to set and to cancel the timer operation.

    10. SLEEP MODE AUTO BUTTONUsed to set sleep mode auto operation.

    11. AIR CIRCULATION BUTTONUsed to circulate the room air without cooling orheating.ENERGY-SAVING COOLING MODE BUTTON(OPTIONAL) For inverter type models

    12. ROOM TEMPERATURE CHECKING BUTTON

    Used to check the room temperature.13. PLASMA BUTTON(OPTIONAL)

    Used to start or stop the plasma-purificationfunction.

    14. HORIZONTAL AIRFLOW DIRECTION CONTROLBUTTON (OPTIONAL)Used to set the desired horizontal airflow direction.

    15. RESET BUTTONUsed prior to resetting time.

    16. 2nd F BUTTONUsed prior to using modes printed in blue at thebottom of buttons.

    17. AUTO CLEAN BUTTON(OPTIONAL)Used to set auto clean mode.In some models this button has a 2nd function of LEDluminosity control.

    18. HEATER BUTTON(OPTIONAL)(Not available in all models)

    19. LCD LUMINOSITY BUTTON(OPTIONAL)Used to adjust LCD luminosity.

    To use the functions printed in blue at the bottom of the buttons press 2 nd F button first and then the required functionbutton. Pressing the 2 nd F button activates the blue printed function of the respective button. To cancel the functionpress the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.

    NOTE

    Type 2 (Wireless LCD)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    44/65

    44

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Type 3 (Wireless Simple)

    3

    1

    4

    2

    5

    6

    8

    7

    2

    4 1

    3

    1. OPERATION DISPLAYDisplays the operation conditions.

    2. CHAOS SWING BUTTONUsed to stop or start louver movement and setthe desired up/down airflow direction

    3. OPERATION MODE SELECTION BUTTONUsed to select the operation mode.

    4. OFF TIMER BUTTONUsed to set the time of stopping opertion.

    5. START/STOP BUTTONOperation starts when this button is pressed, andstops when the button is pressed again.

    6. ROOM TEMPERATURE SETTING BUTTONS

    7. INDOOR FAN SPEED SELECTION BUTTON

    Used to set the time of starting and stoppingoperation.8. JET COOL

    Used to start or stop the speed cooling (Speedcooling operates super high fan speed ingcooling mode.)

    (1) Operation Mode

    (2) Operation Procedure

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    45/65

    45

    Installation SR-6RMG2-02A

    GENERAL WALL MOUNTED

    12. Installation12.1 Installation Map

    Vinyl tape (Wide) Apply after carrying out a drainage test. To carry out the drainage

    test, remove the air filters and pour water into the heatexchanger.

    Saddle

    Gas side pipingLiquid side piping

    Additional drain pipe

    Vinyl tape (Narrow)Drain Hose

    Base Plate

    Air Outlet

    Air Inlet

    Connecting cable

    Tubing Cover

    SleeveBushing-SleevePutty(Gum Type Sealant)Bend the pipe as closelyon the wall as possible,but be careful that itdoesn't break.

    Installation plate

    * The feature can be changed according to the type of model.

    ( ) You should purchase the installation parts.

    NOTE

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    46/65

    46

    Installation SR-6RMG2-02A

    GENERAL WALL MOUNTED

    12.2 Select the best Location

    Indoor unit1. There should not be any heat or steam near the unit.

    2. Select a place where there are no obstacles around theunit.

    3. Make sure that condensation drainage can be convenientlyrouted away.

    5. Ensure that the gap between a wall and the left (or right) ofthe unit is more than 100mm. The unit should be installedas high as possible on the wall, allowing a minimum of200mm from ceiling.

    6. Use a metal detector to locate studs to prevent unneces-sary damage to the wall.

    * The feature can be changed according to the type ofmodel.

    Outdoor unit1. If an awning is built over the unit to prevent direct sunlight

    or rain exposure, make sure that heat radiation from thecondenser is not restricted.

    2. Ensure that the space around the back side and othersides is more than 300mm. The space in front of the unitshould be more than 700mm.

    3. Do not place animals and plants in the path of the warmair.

    4. Take the weight of the air conditioner into account andselect a place where noise and vibration are minimum.

    5. Select a place where the warm air and noise from the airconditioner do not disturb neighbors.

    More than 200More than

    100

    More than 2300

    More than100

    (Unit : mm)

    Install the indoor unit on the wall where the height from the floor is more than 2300mm.

    CAUTION

    S u n r o o f

    Fence orobstacles

    More than300

    More than300

    More than700

    More than600

    (Unit : mm)

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    47/65

    47

    Installation SR-6RMG2-02A

    GENERAL WALL MOUNTED

    2. Measure the wall and mark the centerline. It is also important touse caution concerning the location of the installation plate.Routing of the wiring to power outlets is through the walls typical-ly. Drilling the hole through the wall for piping connections must bedone safely.

    The wall you select should be strong and solid enough to preventvibration

    1. Mount the installation plate on the wall with type "A" screws. Ifmounting the unit on a concrete wall, use anchor bolts.

    Mount the installation plate horizontally by aligning the center-line using Horizontal meter .

    6565

    69 56

    Rightrearpiping

    Leftrearpiping

    Installation PlateMeasuring Tape

    Measuring TapeHanger

    Place a level on raised tabUnit Outline

    207105

    (Unit : mm)

    460 570

    Installation Plate

    ChassisHook

    Type "A" Screws

    Drill the piping hole with a 65mm hole core drill. Drill thepiping hole at either the right or the left with the holeslightly slanted to the outdoor side.

    5 - 7 m m

    ( 3 / 1 6 " ~ 5 / 1 6 " )

    IndoorWALL

    Outdoor

    BushingSleeve

    12.3 Fixing Installation Plate

    12.4 Drill a Hole in the Wall

    Use the sleeve to prevent damage for tube assembly.

    CAUTION

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    48/65

    48

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Installation

    12.5 Flaring Work

    Main cause for gas leakage is due to defect of flaring work. Carry out correct flaring work in the following procedure.

    Cut the pipes and the cable.1. Use the piping kit accessory or the pipes purchased locally.2. Measure the distance between the indoor and the outdoor unit.3. Cut the pipes a little longer than measured distance.4. Cut the cable 1.5m longer than the pipe length.

    Burrs removal1. Completely remove all burrs from the cut cross section of pipe/tube.

    2. While removing the burrs, hold the end of the pipe in downward direc-tion in order to avoid dropping burrs into the tubing.

    Putting nut on- Remove flare nuts attached to indoor and outdoor units, then put them

    on the pipe/tube which have completed its burr removal.(not possible to put them on after finishing flare work)

    Flaring work1. Firmly hold copper pipe in a bar with the dimension shown in

    table below.2. Carry out flaring work with the flaring tool.

    Copperpipe 90 Slanted Uneven Rough

    PipeReamer

    Point down

    Flare nut

    Copper tube

    Bar

    Copper pipe

    Clamp handleRed arrow mark

    Cone

    Yoke

    Handle

    Bar " A "

    Outside diameter A Thicknessmm inch mm mm

    6.35 1/4" 1.1~1.3 0.7

    9.52 3/8" 1.5~1.7 0.812.7 1/2" 1.6~1.8 0.8

    15.88 5/8" 1.6~1.8 1.019.05 3/4" 1.9~2.1 1.0

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    49/65

    49

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Installation

    Check1. Compare the flared work with the figures given below.

    2. If a flared section is defective, cut it off and do flaring workagain.

    Inclined

    Inside is shiny without scratchesSmooth all round

    Even lengthall round

    Surfacedamaged

    Cracked Uneventhickness

    = Improper flaring =

    12.6 Connecting the pipes

    1. Pull the screw caps at the bottom of the indoor unit2. Remove the chassis cover from the unit by loosing 3 screws

    3. Pull back the tubing holder.4. Remove the pipe port cover and position the piping.

    * The feature can be changed according to the type of model.

    Chassis cover

    Right

    Back side view

    Tubing holder

    Backwards

    Left

    Pipe Port

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    50/65

    50

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Installation

    Good case Press the tubing cover and slowly unfold the tubing to downward. And then bend to the left side slowly.

    Bad case Following bending case from right to left directly may cause damage to the tubing.

    * The feature can be changed according to the type of model.

    Installation Information. For right piping. Follow the instruction above.

    CAUTION

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    51/65

    51

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Installation

    1. Hook the indoor unit onto the upper portion of the installation plate.( engage the three hooks at the top of the indoor unit withthe upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving it leftand right

    2. Unlock the tubing holder from the chassis and mount between the chassis and installation plate in order to separate the bot-tom side of the indoor unit from the wall.

    * The feature can be changed according to the type of model.

    Installation plate

    1

    2

    Tubing Holder

    12.7 Installation of Indoor Unit

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    52/65

    52

    Installation SR-6RMG2-02A

    GENERAL WALL MOUNTED

    3. Insert the connecting cable through the bottom side ofindoor unit and connect the cable

    Open the Front Grille Support the Front Grille with supporter Open the Control Cover Connect the connecting cable

    Control Cover

    Case 1 Case 2 Case 3

    4. Tape the tubing pipe, drain hose and the connection cable. Be sure that the drain hose is located at the lowest side of thebundle. Locating at the upper side can cause overflow from the drain pan through the inside of the unit.

    * The feature can be changed according to the type of model.

    Connecting pipe

    Connectingcable

    Tape

    Drain hose

    Indoor Outdoor

    Indoor UnitDrain hose

    Indoor UnitDrain hose

    Insulation(More than 100~300mm

    length and 7mm thickness)Extensiondrain hose

    Drain hose

    Tape

    Connecting pipe

    Connectingcable

    Drain hose

    If the extension drain hose is routed inside the room,insulate the hose with an insulation material* so that drip-ping from sweating (condensation) could not damage fur-niture or floors.

    Foamed polyethylene or equivalent is recommended.

    CAUTION

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    53/65

    53

    Installation SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Connecting the installation pipe and drainhose to the indoor unit.1. Align the center of the pipes and sufficiently tighten the

    flare nut by hand

    2. Tighten the flare nut with a wrench

    3. When needed to extend the drain hose of indoor unit,assembly the drain pipe as shown on the drawing

    Indoor unit tubing Flare nut Pipes

    Wrench

    Indoor unit tubing

    Open-end wrench (fixed)

    Connection pipe

    Flare nut

    Vinyl tape(narrow)Adhesive

    Drain pipe

    Indoor unit drain hose

    Wrap the insulation material around the con-necting portion.1. Overlap the connection pipe insulation material and the

    indoor unit pipe insulation material. Bind them together withvinyl tape so that there may be no gap.

    2. Wrap the area which accommodates the rear piping hous-ing section with vinyl tape.

    3. Bundle the piping and drain hose together by wrappingthem with vinyl tape sufficient enough to cover where theyfit into the rear piping housing section.

    Insulation material

    Wrap with vinyl tape

    Drain hose

    Pipe

    Vinyl tape(wide)

    Vinyl tape(narrow)

    Connection pipe

    Connecting cableVinyl tape (wide) Wrap with vinyl tape

    Indoor unit pipe

    Pipe

    Outside Diameter Torquemm inch kgfcm Nm

    6.35 1/4 180~250 17.6~24.59.52 3/8 340~420 33.3~41.212.7 1/2 550~660 53.9~64.7

    15.88 5/8 630~820 61.7~80.419.05 3/4 990~1210 97~118.6

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    54/65

    54

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Installation

    Finishing the indoor unit installation

    1. Mount the tubing holder in the original positon.2. Ensure that the hooks are properly seated on the installa-

    tion plate by moving it left and right.3. Press the lower left and right sides of the unit against the

    installation plate until the hooks engage into their slots(clicking sound).4. Finish the assembly by screwing the unit to the installation

    plate by using two pieces of type "C" screws. And assemblea chassis cover.

    5. Reconvey the chassis cover in Original place.

    Type 'C' screw

    Outdoor Unit Installation

    1. Remove the tubing cover from the unit by loosening thescrew.

    Cover control

    Tubing Cover

    2. Align the center of the pipings and sufficiently tighten theflare nut by hand.

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    55/65

    55

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    Installation

    3. Finally, tighten the flare nut with torque wrench until thewrench clicks.

    When tightening the flare nut with torque wrench, ensurethe direction for tightening follows the arrow on thewrench.

    Outdoor unit

    Gas side

    Liquid side

    Cap

    3-way or2-way valve

    3-way valveOutside Diameter Torquemm inch kgfcm Nm

    6.35 1/4 180~250 17.6~24.59.52 3/8 340~420 33.3~41.212.7 1/2 550~660 53.9~64.7

    15.88 5/8 630~820 61.7~80.419.05 3/4 990~1210 97~118.6

  • 8/10/2019 PDB Saudi Split (Titan Gold Plus+Fresh+Smart)

    56/65

    56

    SR-6RMG2-02A

    GENERAL WALL MOUNTED

    In