Queensland Building and Construction Commission Regulation 2003 Schedule 2 – Part 23 Effective From 1/01/09 Scope Amendment Technical Amendment 31/03/10 1/4/16 Managerial Amendment 29/05/09 PASSIVE FIRE PROTECTION – FIRE AND SMOKE WALLS AND CEILINGS Licence Class (1) Certify Scope of work Certify, inspect and test fire walls, smoke walls or fire rated ceiling systems requiring a fire resistant level under the Building Code of Australia. Technical qualifications The technical qualifications stated in the technical qualifications document for the licence applied for. Managerial qualifications An approved managerial qualification. Experience requirements Two years experience, which includes experience gained during an apprenticeship or other training, in— (a) the scope of work for the class; or (b) other work, if the commission considers experience in the other work is at least equivalent to experience in the scope of work for the class. Financial requirements The relevant financial requirements in the board’s policies.

Upload: doantruc

Post on 27-Jun-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PASSIVE FIRE PROTECTION – FIRE AND SMOKE … Fire Protection... · Queensland Building and Construction Commission Regulation 2003 Schedule 2 – Part 23 Effective From 1/01/09

Queensland Building and Construction Commission Regulation 2003Schedule 2 – Part 23

Effective From 1/01/09Scope AmendmentTechnical Amendment 31/03/10

1/4/16Managerial Amendment 29/05/09

PASSIVE FIRE PROTECTION –FIRE AND SMOKE WALLS AND CEILINGS

Licence Class(1) Certify

Scope of workCertify, inspect and test fire walls, smoke walls or fire rated ceiling systems requiring afire resistant level under the Building Code of Australia.

Technical qualificationsThe technical qualifications stated in the technical qualifications document for thelicence applied for.

Managerial qualificationsAn approved managerial qualification.

Experience requirementsTwo years experience, which includes experience gained during an apprenticeship orother training, in—

(a) the scope of work for the class; or(b) other work, if the commission considers experience in the other work is at

least equivalent to experience in the scope of work for the class.

Financial requirementsThe relevant financial requirements in the board’s policies.

Page 2: PASSIVE FIRE PROTECTION – FIRE AND SMOKE … Fire Protection... · Queensland Building and Construction Commission Regulation 2003 Schedule 2 – Part 23 Effective From 1/01/09

Queensland Building and Construction Commission Regulation 2003Schedule 2 – Part 23

Effective From 1/01/09Scope AmendmentTechnical Amendment 31/03/10Managerial Amendment 29/05/09

Excerpt from the Department of Housing and Public Works Technical QualificationDocument for this licence class

Passive fire protection—fire and smoke walls and ceilings licence

The successful completion of—(a) Certificate III in Wall and Ceiling Lining CPC31211 and one of the following—

(i) Quality assure fire-rated lining systems CPCCBC4047A;(ii) Prepare a fire protection certification statement or report REP 1; or

(b) successful completion of a course the commission considers is at least equivalent to acourse mentioned in paragraph (a).