panorama-kamin 57/25/121/25 - sydÄnmuuraus€¦ · dimension sheets - panorama-kamin 57/25/121/25...
TRANSCRIPT
![Page 1: Panorama-Kamin 57/25/121/25 - SYDÄNMUURAUS€¦ · Dimension sheets - Panorama-Kamin 57/25/121/25 State: 2018-02-06 … with fire table mounting frame We suggest for CAD planing](https://reader034.vdocuments.mx/reader034/viewer/2022051918/600aceac3a2fee1dc804b90b/html5/thumbnails/1.jpg)
FIREPLACE INSERTS FROM BRUNNER
Panorama-Kamin57/25/121/25
State: 2018-02-06
![Page 2: Panorama-Kamin 57/25/121/25 - SYDÄNMUURAUS€¦ · Dimension sheets - Panorama-Kamin 57/25/121/25 State: 2018-02-06 … with fire table mounting frame We suggest for CAD planing](https://reader034.vdocuments.mx/reader034/viewer/2022051918/600aceac3a2fee1dc804b90b/html5/thumbnails/2.jpg)
Dimension sheets - Panorama-Kamin 57/25/121/25
State: 2018-02-06
… with fire table
![Page 3: Panorama-Kamin 57/25/121/25 - SYDÄNMUURAUS€¦ · Dimension sheets - Panorama-Kamin 57/25/121/25 State: 2018-02-06 … with fire table mounting frame We suggest for CAD planing](https://reader034.vdocuments.mx/reader034/viewer/2022051918/600aceac3a2fee1dc804b90b/html5/thumbnails/3.jpg)
Dimension sheets - Panorama-Kamin 57/25/121/25
State: 2018-02-06
… with fire table mounting frame
We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.deFrames / front versions are marked colored.
![Page 4: Panorama-Kamin 57/25/121/25 - SYDÄNMUURAUS€¦ · Dimension sheets - Panorama-Kamin 57/25/121/25 State: 2018-02-06 … with fire table mounting frame We suggest for CAD planing](https://reader034.vdocuments.mx/reader034/viewer/2022051918/600aceac3a2fee1dc804b90b/html5/thumbnails/4.jpg)
Planning and installation - Panorama-Kamin 57/25/121/25
Ulrich Brunner GmbHZellhuber Ring 17 - 18D-84307 EggenfeldernTelefonat: +49 / (0)87 21 / 7 71-0Telefax: +49 / (0)87 21 / 7 [email protected] | www.brunner.de
BRUNNER Produkte werden ausschließlich vom qualifizierten Fachbetrieb angeboten und verkauft.Technische und Sortiments-Änderungen sowie Irrtum vorbehalten. State: 2018-02-06
Tested according to EN 13229 WValues measured at Rated capacitySuitable for all construction types according to rules OKEEI 107.2
Data for functional demonstrationRated heat power kW 13Fire wood volume kg/h 4.3Combustion performance kW 16Flue gas mass flow g/s 14Flue gas temperature after:
attached steel smoke hood °C 210Necessary supply pressure Pa 12Combustion air consumption m3/h 40Combustion air connection Ø mm 160
Heat distributionInsert / heat accumulator % 50 / -Glass pane (single / double) % 50 / -
Cross-section of gratings 1)
Convection air cm2 1200Warm air cm2 1200
Minimal oven surface for closed construction typeHeat dissipating surface m2 5
Min. distances of fireplace without / with convection casingto insulation layer cm 6to mounting floor cm 2
Thermal insulation without / with air gratings 2)
Mounting wall cm 10 / 6Floor cm 0Ceiling cm 16 / 14Brick lining for combustible wall cm 10
WeightFireplace / combustion chamber kg 280 / 88 / -
Meets requirement/limit values for:Germany/ Austria / Suisse / Norway 1.BImSchV (Stufe 2) / 15a BVG (2015) / LRV / -
1) for fireplace inserts / flue gas pipe / metallic reheating surface2) Values determined with upper air sections; stove cladding is heat emitting.