pactech vol.42 (traditional chinese)
Post on 07-Mar-2016
234 views
Embed Size (px)
DESCRIPTION
● PMMS: 泓格科技電力監控解決方案 ● 利用PDS-700遠端存取多個分散地點的RS-485設備 ● InduSoft 在衛生局疫苗冷藏庫的應用 ● PAC在軌道號誌監測之應用 ● FRnet 匯流排在拉拔機控制系統中的應用 ● 地下水位雲端監測系統 ● 看好機械自動化產業 泓格喬遷台中新辦公室TRANSCRIPT
ICP DAS CO.LTD 111
TEL886-3-5973366FAX886-3-597-3733
Website: http://www.icpdas.com.tw/
E-mailservice@icpdas.com
Contents
235 137 7 2 TEL:02-89192220
33 16 1 TEL:02-29500655
360 24 1 TEL:04-23285522
505 3 TEL:07-2157688
02-8919-2220 1108
1 PMMS: / Stanley Lin
7 PDS-700 RS-485 / Tammy Chuang
10 InduSoft / Ian Chien
13 PAC / Cony Yu
17 FRnet /
21 / Randy Chu
23 / Digitimes
24 - /
25 /
26 /
Products Column
1 MAR. - MAY 2014
PMMS
PMC
InduSoft
PMC
PMMS
PMC PMMS
PMC
( ) RS-485 Ethernet
I/O
PMC
Modbus TCP/RTU
SCADA
PMMS: / Stanley Lin (TEL02-89192220 ; E-mail : service@icpdas.com)
PMMS (Power Monitoring & Management Solution)
PMC
Products Column
2MAR. - MAY 2014
- PMC
Web-based
PMC
PMC
PMC
(CSV )
PMC
Micro SD PMC Micro SD 4G Micro
SD Micro
SD CSV
FTP Server/Client
PMC FTP Client Micro SD
FTP
PMC
Micro SD
PC FTP Client
PMC FTP Server
PMC
Modbus TCP/RTU SCADA PMC Modbus TCP/RTU Slave
SCADA HMI
Products Column
3 MAR. - MAY 2014
Flash HMI PMC Flash HMI
HMI
PMC Flash HMI
Adobe Flash
HMI
HMI
HMI
I/O ( PMC-5151)
PMC-5151 XW-
BoardM-7000 I/O ModbusTCP/RTU
Slave PM-311x DO Relay
I/O
(Schedule) ( PMC-5151)PMC-5151 (Schedule)
IF-THEN-ELSE ( PMC-5151)
PMC-5151 IF-THEN-ELSE
PMC-5151
IF-THEN-
ELSE
PMC-5151 I/O
( Email /SMS I/O
AO/DO ) IF-THEN-ELSE
-
z
z z CT z CT ( 1%PF=1)
z RS-485EthernetCAN bus
z Modbus RTUModbus TCPCANopen (NotePMC Modbus RTU Modbus TCP )
z Power Relay
Products Column
4MAR. - MAY 2014
PMC
PMC-5141 PMC-5151
16
( Modbus RTU ) 24
( Modbus RTU/TCP )
I/O XW-107
XW-107XW-110XW-304XW-310 XW-Board 8 Modbus I/O ( Modbus TCP/RTU )
Yes
SCADA HMI Yes (Modbus TCP Protocol)Yes
( Modbus TCP/RTU Protocol)
PMC Data Server Yes
Yes Yes ( )
Flash HMI Yes
Yes
Yes
Yes
Yes
(IF-THEN-ELSE )
Email Yes ( SSL )
SMS Yes (SMS )Yes
(SMSSMS )
I/O Yes ( XW-107) Yes ( I/O )
(Schedule) Yes ( / )
(SNTP) Yes
PM-3133 PM-3112 / PM-3112-MTCP PM-3114 / PM-3114-MTCP 3
10 - 500 V 10 - 300 V
CT,CT 10 mm ( 60 A), CT 16 mm (100 A), CT 24 mm (200 A)
50 / 60 Hz
3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT 1P2W 1P4W
Power Parameters Measures
RMS (Vrms) RMS (Irms) (kW) (kWh) (kVA) (kVAh) (kVAR) (kVARh) (PF)
W 1% (PF=1)
/ RS485 / Modbus RTU PM-311xRS485 / Modbus RTUPM-311x-MTCPEthernet / Modubs TCP
Form A (Normal Open) x 2; Relay Contact Voltage : 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Products Column
5 MAR. - MAY 2014
- InduSoft (SCADA)
InduSoft Web Studio
SCADA (Supervisory Control And Data
Acquisition)HMI (Human-Machine Interface)
PMC
InduSoft
InduSoft
PMC
InduSoft
PMC Data Server PMC Data Server
PMC
PMC
PMC Micro SD PMC Data
Server Ethernet PMC
PMC
PMC Data Server MS Access / MS
SQL / MySQL
+PMC
+PMC Data Server
PMC
RS-485 Ethernet
SCADA
Products Column
6MAR. - MAY 2014
PMC
PMC
PMC
PMC
SCADA
PMC
SMS
PMMS
PMC
/SMS
I/O
Indusoft (SCADA)
PMMS
PMMS
PMMS (http://PMMS.icpdas.
com) (http://www.icpdas.com)
Technology
7 MAR. - MAY 2014
PDS-700 RS-485 / Tammy Chuang (TEL03-5973366 #2109E-mailtammy_chuang@icpdas.com)
Serial-to-Serial RS-485
PDS-700 Pair-connection Pair-connection TCP/IP
RS-485 .
PDS-700
RS-232 RS-
422/485
VxComm Utility PDS-700
COM Port
COM Port
PDS-700
Ethernet
PDS-700
Ethernet
Virtual
COM TCP/IP
: Serial-
to-Serial
RS-485
PDS-700
Pair-connection
Pair-connection
TCP/IP
RS-485
Technology
8MAR. - MAY 2014
TCP Client VxComm Driver/Utility
PDS-700 Web Server
Client-
Mode PDS-700 TCP Client
Server-Mode PDS-700
TCP Client PC
PDS-700 RS-485
1: VxComm Driver/Utility
Utility PDS-700
2: Firmware v3.2.32 [Oct 07 2013]
1. PDS-720#1, #2, #3 IP Utility Web
2. VCOM3 Firmware Version Firmware Firmware
3: PDS-720#1, #2, #3
COM Port
1. COM Port Settings COM Port
2. COM PortBaud Rate Data Format , : Port (COM0 for All PORTS)COM1Baud Rate9600Data Format 8,N,1
3. Operation Mode M0 (Transparent Mode)
4. Save current settings to EEPROM Apply Current settings SET COM PORT
5. Set Remote VCOM3 connection PDS-720#1, #2, #3 (Server/Client) COM PORT
1
2
3
45
Technology
9 MAR. - MAY 2014
5: PDS-720#1 Server Mode
PDS-720#1 Remote Vcom3 connection Setup
Page Local COM port/Remote COM
port NONE
6: PDS-720#2, #3 Client Mode
PDS-720#2, #3 Remote Vcom3 connection
Setup Page
1. 2 TCP/IP : Add COM1 PDS-700#2, #3 COM port connect to IP=10.0.8.22 PDS-720#1 IP port= 10001 PDS-700#1 TCP Port
3
2
1
2. Submit
3. TCP/IP 4. PDS-700#2, #3 TCP/IP
PDS-700
: http://www.icpdas.
com/products/Industrial/pds/PDS-700_Series.htm
Application
10MAR. - MAY 2014
InduSoft / Ian Chien (TEL07-2157688E-mailian_chien@icpdas.com)
Indusoft Indusoft
SCADASupervisory Control And Data Acquisition
HMIHuman-Machine Interface
Indusoft Web Studio Windows NT
2000XP78 Windows CE
200 OPC
XMLActiveX
Internet/Intranet TCP/IP
IE HTML5
sensor
( . )
InduSoft SCADA VP-25W9
PT-100
Application
11 MAR. - MAY 2014
I-87053WI-87055W
DI
I-87017ZW
(PT-100) M-7015P
VP-25W9 InduSoft
5.7
VP-25W9
PC InduSoft TCP/
IP VP-25W9
ACCESS
GTM-201-RS232 SMS
IE
HTML5
InduSoft
InduSoft 0 255
ViewPAC(VP)
RISC PXA270 CPU (520MHz)
USBEthernetRS232/485
3 I/O 5.7
10.4
Windows CE.NET 5.0
VP-25W1VP-4131
VB.NETC# PLC SCADA
Application
12MAR. - MAY 2014
VP-25W1, VP-4131
VB.NET, C#
Soft PLC VP-25W7, VP-4137
ISaGRAF Runtime
SCADA VP-25W9, VP-4139
InduSoft Runtime
GTM-201-RS232 GPRS/GSM
RS-232 GPRS/GSM
M2M GSM 850 MHz, EGSM 900
MHz, DCS 1800 MHz PCS 1900 MHz
GTM-201-RS232 GPRS/GSM
TCP/IP stack
GTM-201-RS232 PLC
PC GPRS
: http://www.icpdas.com./products/
GSM_GPRS/wireless/GTM-201.htm
InduSoft
1F5F12F
GTM-201-RS232
InduSoft
InduSoft
Application
13 MAR. - MAY 2014
PAC / Cony Yu (TEL02-29500655E-mailcony@icpdas.com)
(Horsecar)
S
Application
14MAR. - MAY 2014
RS-422/RS-232 VPINVPIVDU
/
/
VDU PIDS / /
/ ASCII
Code / /
WinPAC-8XX7
(Programmable Automation Controller, PAC)
CPU
/ ( USBVGAEthernetRS-
232RS485 ) IEC-
WP-8137 WP-8437 WP-8837 WP-8147 WP-8447 WP-8847
Windows CE 5.0
ISaGRAF
ISaGRAF Ver. 3 IEC 61131-3 . LD, ST, FBD, SFC, IL FC.
: 3 ~ 15 ms
: 15 ~ 50 ms
/ SDRAM 520 MHz / 128 MB
Flash 128 MB 96 MB
microSD microSD ( 32 GB)
(RTC) / ,
VGA 640 x 480, 800 x 600, 1024 x 768
640 x 480, 800 x 600
Ethernet RJ-45 x 2, 10/100 Base-TX (Auto-negotiating, LED indicators)
1 4 8 1 4 8
: I-8K I-87K
-25 ~ +75 C
+10 ~ +30 VDC
, (1 A @ 24 VDC)
S WinPAC-8XX7
S
61131-3 (FBD)
(LAD) (SFC) (STL)
( I-8014W
I-87053WI-87057W) RS-485/RS-232(
I-8144iW) /
Application
15 MAR. - MAY 2014
/
AF ( )PF (
) ( ) (
) ( ) (
) ( ) ( )
( ) ( )
( ) ( )
(
)
0.5 2
(
)
S
Application
16MAR. - MAY 2014
Application
17 MAR. - MAY 2014
FRnet / (TEL: 8621-6247-1722 ; e-mail: sales_sh@icpdas.com.cn)
FRnet
I/O
I/O
FRnet I/O
I/O
FRnet iPAC
90KW
75KW
10005001900mm
1#2#
1#
3#
4#2#
5#6# 7#
3#
Application
18MAR. - MAY 2014
10
WeinView
FRnet
iPAC IP-
8447iPAC
SoftPLC MiniOS7
CAN FRnet
iPAC 4 (MCU)
I/O I/O
MiniOS7 MiniOS7 DOS
ROM-DOS
I/O I-8504W
I-8