pactech vol.42 (traditional chinese)

Download PACTECH Vol.42 (Traditional Chinese)

Post on 07-Mar-2016

234 views

Category:

Documents

6 download

Embed Size (px)

DESCRIPTION

● PMMS: 泓格科技電力監控解決方案 ● 利用PDS-700遠端存取多個分散地點的RS-485設備 ● InduSoft 在衛生局疫苗冷藏庫的應用 ● PAC在軌道號誌監測之應用 ● FRnet 匯流排在拉拔機控制系統中的應用 ● 地下水位雲端監測系統 ● 看好機械自動化產業 泓格喬遷台中新辦公室

TRANSCRIPT

  • ICP DAS CO.LTD 111

    TEL886-3-5973366FAX886-3-597-3733

    Website: http://www.icpdas.com.tw/

    E-mailservice@icpdas.com

    Contents

    235 137 7 2 TEL:02-89192220

    33 16 1 TEL:02-29500655

    360 24 1 TEL:04-23285522

    505 3 TEL:07-2157688

    02-8919-2220 1108

    1 PMMS: / Stanley Lin

    7 PDS-700 RS-485 / Tammy Chuang

    10 InduSoft / Ian Chien

    13 PAC / Cony Yu

    17 FRnet /

    21 / Randy Chu

    23 / Digitimes

    24 - /

    25 /

    26 /

  • Products Column

    1 MAR. - MAY 2014

    PMMS

    PMC

    InduSoft

    PMC

    PMMS

    PMC PMMS

    PMC

    ( ) RS-485 Ethernet

    I/O

    PMC

    Modbus TCP/RTU

    SCADA

    PMMS: / Stanley Lin (TEL02-89192220 ; E-mail : service@icpdas.com)

    PMMS (Power Monitoring & Management Solution)

    PMC

  • Products Column

    2MAR. - MAY 2014

    - PMC

    Web-based

    PMC

    PMC

    PMC

    (CSV )

    PMC

    Micro SD PMC Micro SD 4G Micro

    SD Micro

    SD CSV

    FTP Server/Client

    PMC FTP Client Micro SD

    FTP

    PMC

    Micro SD

    PC FTP Client

    PMC FTP Server

    PMC

    Modbus TCP/RTU SCADA PMC Modbus TCP/RTU Slave

    SCADA HMI

  • Products Column

    3 MAR. - MAY 2014

    Flash HMI PMC Flash HMI

    HMI

    PMC Flash HMI

    Adobe Flash

    HMI

    HMI

    HMI

    I/O ( PMC-5151)

    PMC-5151 XW-

    BoardM-7000 I/O ModbusTCP/RTU

    Slave PM-311x DO Relay

    I/O

    (Schedule) ( PMC-5151)PMC-5151 (Schedule)

    IF-THEN-ELSE ( PMC-5151)

    PMC-5151 IF-THEN-ELSE

    PMC-5151

    IF-THEN-

    ELSE

    PMC-5151 I/O

    ( Email /SMS I/O

    AO/DO ) IF-THEN-ELSE

    -

    z

    z z CT z CT ( 1%PF=1)

    z RS-485EthernetCAN bus

    z Modbus RTUModbus TCPCANopen (NotePMC Modbus RTU Modbus TCP )

    z Power Relay

  • Products Column

    4MAR. - MAY 2014

    PMC

    PMC-5141 PMC-5151

    16

    ( Modbus RTU ) 24

    ( Modbus RTU/TCP )

    I/O XW-107

    XW-107XW-110XW-304XW-310 XW-Board 8 Modbus I/O ( Modbus TCP/RTU )

    Yes

    SCADA HMI Yes (Modbus TCP Protocol)Yes

    ( Modbus TCP/RTU Protocol)

    PMC Data Server Yes

    Yes Yes ( )

    Flash HMI Yes

    Yes

    Yes

    Yes

    Yes

    (IF-THEN-ELSE )

    Email Yes ( SSL )

    SMS Yes (SMS )Yes

    (SMSSMS )

    I/O Yes ( XW-107) Yes ( I/O )

    (Schedule) Yes ( / )

    (SNTP) Yes

    PM-3133 PM-3112 / PM-3112-MTCP PM-3114 / PM-3114-MTCP 3

    10 - 500 V 10 - 300 V

    CT,CT 10 mm ( 60 A), CT 16 mm (100 A), CT 24 mm (200 A)

    50 / 60 Hz

    3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT 1P2W 1P4W

    Power Parameters Measures

    RMS (Vrms) RMS (Irms) (kW) (kWh) (kVA) (kVAh) (kVAR) (kVARh) (PF)

    W 1% (PF=1)

    / RS485 / Modbus RTU PM-311xRS485 / Modbus RTUPM-311x-MTCPEthernet / Modubs TCP

    Form A (Normal Open) x 2; Relay Contact Voltage : 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC

  • Products Column

    5 MAR. - MAY 2014

    - InduSoft (SCADA)

    InduSoft Web Studio

    SCADA (Supervisory Control And Data

    Acquisition)HMI (Human-Machine Interface)

    PMC

    InduSoft

    InduSoft

    PMC

    InduSoft

    PMC Data Server PMC Data Server

    PMC

    PMC

    PMC Micro SD PMC Data

    Server Ethernet PMC

    PMC

    PMC Data Server MS Access / MS

    SQL / MySQL

    +PMC

    +PMC Data Server

    PMC

    RS-485 Ethernet

    SCADA

  • Products Column

    6MAR. - MAY 2014

    PMC

    PMC

    PMC

    PMC

    SCADA

    PMC

    SMS

    PMMS

    PMC

    /SMS

    I/O

    Indusoft (SCADA)

    PMMS

    PMMS

    PMMS (http://PMMS.icpdas.

    com) (http://www.icpdas.com)

  • Technology

    7 MAR. - MAY 2014

    PDS-700 RS-485 / Tammy Chuang (TEL03-5973366 #2109E-mailtammy_chuang@icpdas.com)

    Serial-to-Serial RS-485

    PDS-700 Pair-connection Pair-connection TCP/IP

    RS-485 .

    PDS-700

    RS-232 RS-

    422/485

    VxComm Utility PDS-700

    COM Port

    COM Port

    PDS-700

    Ethernet

    PDS-700

    Ethernet

    Virtual

    COM TCP/IP

    : Serial-

    to-Serial

    RS-485

    PDS-700

    Pair-connection

    Pair-connection

    TCP/IP

    RS-485

  • Technology

    8MAR. - MAY 2014

    TCP Client VxComm Driver/Utility

    PDS-700 Web Server

    Client-

    Mode PDS-700 TCP Client

    Server-Mode PDS-700

    TCP Client PC

    PDS-700 RS-485

    1: VxComm Driver/Utility

    Utility PDS-700

    2: Firmware v3.2.32 [Oct 07 2013]

    1. PDS-720#1, #2, #3 IP Utility Web

    2. VCOM3 Firmware Version Firmware Firmware

    3: PDS-720#1, #2, #3

    COM Port

    1. COM Port Settings COM Port

    2. COM PortBaud Rate Data Format , : Port (COM0 for All PORTS)COM1Baud Rate9600Data Format 8,N,1

    3. Operation Mode M0 (Transparent Mode)

    4. Save current settings to EEPROM Apply Current settings SET COM PORT

    5. Set Remote VCOM3 connection PDS-720#1, #2, #3 (Server/Client) COM PORT

    1

    2

    3

    45

  • Technology

    9 MAR. - MAY 2014

    5: PDS-720#1 Server Mode

    PDS-720#1 Remote Vcom3 connection Setup

    Page Local COM port/Remote COM

    port NONE

    6: PDS-720#2, #3 Client Mode

    PDS-720#2, #3 Remote Vcom3 connection

    Setup Page

    1. 2 TCP/IP : Add COM1 PDS-700#2, #3 COM port connect to IP=10.0.8.22 PDS-720#1 IP port= 10001 PDS-700#1 TCP Port

    3

    2

    1

    2. Submit

    3. TCP/IP 4. PDS-700#2, #3 TCP/IP

    PDS-700

    : http://www.icpdas.

    com/products/Industrial/pds/PDS-700_Series.htm

  • Application

    10MAR. - MAY 2014

    InduSoft / Ian Chien (TEL07-2157688E-mailian_chien@icpdas.com)

    Indusoft Indusoft

    SCADASupervisory Control And Data Acquisition

    HMIHuman-Machine Interface

    Indusoft Web Studio Windows NT

    2000XP78 Windows CE

    200 OPC

    XMLActiveX

    Internet/Intranet TCP/IP

    IE HTML5

    sensor

    ( . )

    InduSoft SCADA VP-25W9

    PT-100

  • Application

    11 MAR. - MAY 2014

    I-87053WI-87055W

    DI

    I-87017ZW

    (PT-100) M-7015P

    VP-25W9 InduSoft

    5.7

    VP-25W9

    PC InduSoft TCP/

    IP VP-25W9

    ACCESS

    GTM-201-RS232 SMS

    IE

    HTML5

    InduSoft

    InduSoft 0 255

    ViewPAC(VP)

    RISC PXA270 CPU (520MHz)

    USBEthernetRS232/485

    3 I/O 5.7

    10.4

    Windows CE.NET 5.0

    VP-25W1VP-4131

    VB.NETC# PLC SCADA

  • Application

    12MAR. - MAY 2014

    VP-25W1, VP-4131

    VB.NET, C#

    Soft PLC VP-25W7, VP-4137

    ISaGRAF Runtime

    SCADA VP-25W9, VP-4139

    InduSoft Runtime

    GTM-201-RS232 GPRS/GSM

    RS-232 GPRS/GSM

    M2M GSM 850 MHz, EGSM 900

    MHz, DCS 1800 MHz PCS 1900 MHz

    GTM-201-RS232 GPRS/GSM

    TCP/IP stack

    GTM-201-RS232 PLC

    PC GPRS

    : http://www.icpdas.com./products/

    GSM_GPRS/wireless/GTM-201.htm

    InduSoft

    1F5F12F

    GTM-201-RS232

    InduSoft

    InduSoft

  • Application

    13 MAR. - MAY 2014

    PAC / Cony Yu (TEL02-29500655E-mailcony@icpdas.com)

    (Horsecar)

    S

  • Application

    14MAR. - MAY 2014

    RS-422/RS-232 VPINVPIVDU

    /

    /

    VDU PIDS / /

    / ASCII

    Code / /

    WinPAC-8XX7

    (Programmable Automation Controller, PAC)

    CPU

    / ( USBVGAEthernetRS-

    232RS485 ) IEC-

    WP-8137 WP-8437 WP-8837 WP-8147 WP-8447 WP-8847

    Windows CE 5.0

    ISaGRAF

    ISaGRAF Ver. 3 IEC 61131-3 . LD, ST, FBD, SFC, IL FC.

    : 3 ~ 15 ms

    : 15 ~ 50 ms

    / SDRAM 520 MHz / 128 MB

    Flash 128 MB 96 MB

    microSD microSD ( 32 GB)

    (RTC) / ,

    VGA 640 x 480, 800 x 600, 1024 x 768

    640 x 480, 800 x 600

    Ethernet RJ-45 x 2, 10/100 Base-TX (Auto-negotiating, LED indicators)

    1 4 8 1 4 8

    : I-8K I-87K

    -25 ~ +75 C

    +10 ~ +30 VDC

    , (1 A @ 24 VDC)

    S WinPAC-8XX7

    S

    61131-3 (FBD)

    (LAD) (SFC) (STL)

    ( I-8014W

    I-87053WI-87057W) RS-485/RS-232(

    I-8144iW) /

  • Application

    15 MAR. - MAY 2014

    /

    AF ( )PF (

    ) ( ) (

    ) ( ) (

    ) ( ) ( )

    ( ) ( )

    ( ) ( )

    (

    )

    0.5 2

    (

    )

    S

  • Application

    16MAR. - MAY 2014

  • Application

    17 MAR. - MAY 2014

    FRnet / (TEL: 8621-6247-1722 ; e-mail: sales_sh@icpdas.com.cn)

    FRnet

    I/O

    I/O

    FRnet I/O

    I/O

    FRnet iPAC

    90KW

    75KW

    10005001900mm

    1#2#

    1#

    3#

    4#2#

    5#6# 7#

    3#

  • Application

    18MAR. - MAY 2014

    10

    WeinView

    FRnet

    iPAC IP-

    8447iPAC

    SoftPLC MiniOS7

    CAN FRnet

    iPAC 4 (MCU)

    I/O I/O

    MiniOS7 MiniOS7 DOS

    ROM-DOS

    I/O I-8504W

    I-8