Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
Overview
• Lifetime Model• LM Tests• New Schedule• Open Points• Conclusion
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
Lifetime Model
• LM manufacture started Nov 2000 at MPIA, drawings from Zeiss
• Assembly planned for Mar/Apr 2001 at Zeiss
• Design frozen
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
Chopper Overview• Fully manufactured at
MPIA mechanical workshop (A. Böhm and co-workers)
housing
mirror
drive unit with 3 coils
position sensor unit
flexible pivot
temperature sensor
I/F point
pigtail with I/F connector
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
Rotor
• Al 6061
• 12g, 3.23x10-7kgm2
integratedlightweight mirror
sensor magnet
drive magnets
balancing masses
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
Flexural Pivots
• CuBe, double-stage 12°
• 5Nmm/rad
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
New Schedule
Mai
00
J un
00
J ul
00
Aug
00
Sep
00
Okt
00
Nov
00
Dez
00
J an
01
Feb
01
Mrz
01
Apr
01
Mai
01
J un
01
J ul
01
Aug
01
Sep
01
Okt
01
Nov
01
Kick Off
Chopper PDR
Freezing of Specs
LM Manufacture at MPI A
LM Assembly at Zeiss
LM Performance / Functional Tests
Lifetimetest at MPI A
Delivery LM
QM Manufacture at MPI A
QM Assembly at Zeiss
QM Tests
Delivery QM
Chopper CDR
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
Work to do
• Consider FPU structural analysis (KT) with respect to vibration loads for the
chopper
• Implementation of “PACS black color” for the chopper
– First test on LM spare cover– Qualification for QM, FM, FS (MPE)
• Formal agreement with MPE for proposed QM/FM test procedures (#axes, temperature level)
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
Conclusion• Features of promising MPIA prototype nearly
fully adopted in Chopper design of Zeiss Specs to be achieved
• Optimized choice of materials, dimensions, linkage to be verified in LM and QM tests industrial QA guarantees outcomeof a space qualified system
• Interface to warm electronics nearly specifiedminor effort to fix cable routingand launch lock details
• Start of cold lifetime tests in June 2001• QM to be delivered in October 2001
internal
external
Chopper
PACS IIDR, Noordwijk 1-2 Mar 2001
LM TestsL M tes tp lan
w arm u n it
co ld u n it
7 7 K u n it
-----------------
EMC laboratory
a lignment te lescopecryostat
BB e lectronics
position measuringdevice
alignment te lescope
alignment te lescope
visual check
removal from cryostat
warm function check
warm-up to 300Kventing
life time cycling1/3 opereration1/3 ca libration
cold function check
life time cycling1/3 opereration1/3 ca libration
cold function check
life time cycling1/3 opereration1/3 ca libration
cold function check
cold function check
zero position
inclination anglemodulation functionpower consumption
evacuationcool-down to 4K
warm function check
in tegration in to cryostat
vibration test
EMC test
assembly
warm function check
warm-up to 300Kventing
77K function check
cold vibration x-axis
77K function check
evacuationcool-down to 77K
warm function check
in tegration in tovibration cryostat
in x position
warm function check
vibration test
MPIA