paco vl 40127

1
11/19/12 Grundfos Quotation System 12.0.0.22 1/1 grundfos.intelliquip.com/IEQ_HydSel/HydSel_JSP/intelliquip/main.jsp?selectedURL=/performancedatash… ©2000-2012

Upload: sas999333

Post on 30-Nov-2015

57 views

Category:

Documents


4 download

DESCRIPTION

pump inline

TRANSCRIPT

Page 1: Paco VL 40127

11/19/12 Grundfos Quotation System 12.0.0.22

1/1grundfos.intelliquip.com/IEQ_HydSel/HydSel_JSP/intelliquip/main.jsp?selectedURL=/performancedatash…

Home | New Item | Documents | Session Preferences | Feedback | Help | Return to Website

Selection Criteria Selection Results Configuration

Conditions of Service Search Results Configurator

Product Lines Performance Curve Construction Datasheet

Size List Performance Datasheet Dimensional Drawing

Life Cycle Cost

Units Curve Preferences Print Show Flow #2 Multi-Speed Curves

Performance Datasheet Additional Data Multiple Conditions

Header Information

Performance Details

PACO Model : 40127 VL

Stages : 1

Operating Conditions

Flow , rated 300.0 USgpm

Differential head / pressure, rated (requested) 127.0 ft

Differential head / pressure, rated (actual) : 126.9 ft

Suction pressure, rated / max 0.00 / 0.00 psi.g

NPSH available, rated Ample ft

Frequency 60 Hz

Performance

Speed criteria Synchronous Variable

Speed, rated set @ 1,760 rpm

Impeller diameter, rated set @ 11.11 in

Impeller diameter, maximum : 12.10 in

Impeller diameter, minimum : 9.50 in

Eff iciency : 70.94 %

NPSH required / margin required : 9.88 / 0.00 ft

- : -

MCSF : 116.0 USgpm

Head, maximum, rated diameter : 130.3 ft

Head rise to shutoff : 2.59 %

Flow , best eff. point (BEP) : 512.1 USgpm

Flow ratio (rated / BEP) : 58.58 %

Diameter ratio (rated / max) : 91.82 %

Cutw ater ratio (rated / cutw ater) : 86.33 %

Head ratio (rated dia / max dia) : 83.50 %

Cq/Ch/Ce ANSI/HI 9.6.7-2010 : 1.00 / 1.00 / 1.00

Selection status : Acceptable

Based on curve number

Liquid type

Additional liquid description

Solids diameter, max

Solids concentration, by volume

Temperature, max

Fluid density, rated / max

Viscosity, rated

Vapor pressure, rated

Material requested

Material selected

Maximum w orking pressure

Maximum allow able w orking pressure

Maximum allow able suction pressure

Hydrostatic test pressure

Motor sizing specif ication

Margin over specif ication

Service factor

Pow er, hydraulic

Based on duty point (rated pow er)

Non-overloading (max pow er)

Pow er reserve (rated / max / sizing spec)

Nameplate motor rating

Performance Curve

Curve Comment

Create/edit curve comment

©2000-2012