CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TOPREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.WARNING: Before installing or maintaining the luminary, make sure all powers areTURNED OFF.Verify that supply voltage is correct by comparing it with the label information on allfixtures.Make all connections in accordance with the NEC requirements, and make sure allluminaries are properly secured to prevent any wire complications. This luminary isto always be installed with the lens facing down and its not to exceed the maximumambient temperature rating noted on the specification sheet.
RKLN Series LED Linear Retrofit Kit Installation Sheet
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2017 PacLights All Rights Reserved
STANDARD INSTALLATION STEPS
7. Adjust the Tilt Angle on the F2SBluminaire, once the Tilt Angle is asdesired, finish tightening the SocketHead bolt to firmly tighten the F2SB withthe Trunnion Mount.
LED DRIVER
TO LOAD
[LED STRIPS]
[WHITE]
[BLACK]
NEUTRAL
[WHITE]
GROUND [GREEN]
HOT
[BLACK]
INP
UT
OU
TP
UT
02-00024-010318-1 Note: Instructions are subject to change at any time without notice
5. Run the power cord from thetrunnion mount to the F2SB luminaire,Once the cable has been insertedinside the F2SB, connect the powercable to the LED Driver inside the F2SB.In order to access the LED Drivercables, the electrician must first remove the [6] screws from the service door using a #2 Phillipsscrew driver and make allconnections inside the luminaire.
6. Once all wiring is complete,Close the service door and usethe M12 bolt to fasten theTrunnion Mount to the F2SB.Do not fasten completely.
6) Install the RKLN LED Driver in the
same location in which the ballast is
placed (underneath the ballast cover)
and LED strips in the same location
in which the florescent lights
were located by using the
magnetic strips.
7a. Connect the input line of the driver and power line. Please refer to diagram at
the bottom of the page.
7b. Connect the output line cables of the driver and the strip wires and connect the
wires together with their preset connectors for an easy installation. Push together
until you hear a small clicking sound.
1.Make sure all powers are
off before beginning any
installations.
2. Open the Troffer Cover
3. Remove the original
fluorescent tubes inside
the fixture.
Includes: All Retrofit Kits in the RKLN Series
4) Remove the ballast
cover panel.
5) After you remove
the ballast cover, you
should see the ballast.
You can bypass the
ballast and proceed
with the installation.
8) Close the Light with its flosted lens frame.
9) You are now ready to enjoy
your Linear Retrofit Kit.
WIRING DIAGRAM
Number of Strips may vary
depending on the RKLN Kit
that’s being installed.