p-series - mylinkdrive-bs... · specifications are subect to change without notice. ... general...

5
Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule No.: P-SERIES Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. SUBMITTAL DATA: PEAD-A24AA4 & PUY-A24NHA4 (-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR CONDITIONING SYSTEM GENERAL FEATURES Horizontal-ducted indoor unit features medium static pressure capability Thin body: 9-7/8” high Built-in drain mechanism for condensate removal; lifts to 27-9/16" Air filter is included with indoor unit Quiet operation—both indoor and outdoor units Automatic fan speed control Auto restart following a power outage Self-check function—integrated diagnostics Knockout for ventilation air Limited warranty: five years parts and seven years compressors OPTIONAL ACCESSORIES Indoor Unit □ Filter Box with MERV 13 Filters (FBM2-3) Outdoor Unit □ Drain Pan (PAC-SG64DP) □ Drain Socket (PAC-SG61DS) □ Three-pole Disconnect Switch (TAZ-MS303) □ Wind Baffle (WB-PA2) □ Air Outlet Guide (PAC-SG59SG □ Mounting Base (DSD-400N) □ Mounting Pad (ULTRILITE2) □ Wall-mounting Brackets (CWMB1) Controller Options □ Wireless Wall-mounted Remote Controller Kit (MHK1)* □ Portable Controller (MCCH1)* □ Outdoor Air Sensor (MOS1)* *See Submittal for information on each option. □ Wall-mounted Wired Remote Controller (PAR-21MAAU) □ M-NET Adapter (PAC-SF81MA) □ CN51 Connector for Multiple Remote Controller Adapters/Duct Fan Controller (PAC-725AD) □ CN32 Connector for Remote On/Off (PAC-715AD) □ Remote Temperature Sensor (PAC-SE41TS) □ Remote Operation Adapter - Display and On/Off (PAC-SF40RM) □ Hand-held Wireless Remote Controller (PAR-FL32MA; req. PAR-FA32MA-E) □ Wireless Signal Receiver Module (PAR-FA32MA-E) □ Lockdown Bracket for Hand-held Controller (RCMKP1CB) □ Control/Service Tool (PAC-SK52ST) Outdoor Unit: PUY-A24NHA4 (-BS) SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly ; Valve Bed: Epoxy resin coating (at edge face) • Screws (used outer side): Zinc nickel coating 5μm + Polyvinylidene chloride coating “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.. UNIT OPTION □ Standard Model……………..........…….................PUY-A24NHA4 □ Sea Coast (BS) Model…….…………………..PUY-A24NHA4-BS Indoor Unit: PEAD-A24AA4

Upload: vukhanh

Post on 06-Sep-2018

232 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: P-SEriES - MyLinkDrive-BS... · Specifications are subect to change without notice. ... gENEral FEaturES • Horizontal-ducted indoor unit features medium static pressure capability

Job Name: Location: Date:Purchaser: Engineer:Submitted to: For Reference Approval ConstructionSystem Designation: Schedule No.:

P-SERIES

Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.

Submittal Data: PEaD-a24aa4 & PuY-a24NHa4 (-bS) 24,000 btu/H HorizoNtal-DuctED air coNDitioNiNg SYStEm

gENEral FEaturES• Horizontal-ductedindoorunitfeaturesmediumstaticpressurecapability• Thinbody:9-7/8”high• Built-indrainmechanismforcondensateremoval;liftsto27-9/16"• Airfilterisincludedwithindoorunit• Quietoperation—bothindoorandoutdoorunits• Automaticfanspeedcontrol• Autorestartfollowingapoweroutage• Self-checkfunction—integrateddiagnostics• Knockoutforventilationair• Limitedwarranty:fiveyearspartsandsevenyearscompressors

oPtioNal accESSoriESindoor unit□ FilterBoxwithMERV13Filters(FBM2-3)

outdoor unit□ DrainPan(PAC-SG64DP)□ DrainSocket(PAC-SG61DS)□ Three-poleDisconnectSwitch(TAZ-MS303)□ WindBaffle(WB-PA2)□ AirOutletGuide(PAC-SG59SG□ MountingBase(DSD-400N)□ MountingPad(ULTRILITE2)□ Wall-mountingBrackets(CWMB1)

controller options□ WirelessWall-mountedRemoteControllerKit(MHK1)*□ PortableController(MCCH1)*□ OutdoorAirSensor(MOS1)*

*SeeSubmittalforinformationoneachoption.□ Wall-mountedWiredRemoteController(PAR-21MAAU)□ M-NETAdapter(PAC-SF81MA)□ CN51ConnectorforMultipleRemoteControllerAdapters/DuctFanController(PAC-725AD)□ CN32ConnectorforRemoteOn/Off(PAC-715AD)□ RemoteTemperatureSensor(PAC-SE41TS)□ RemoteOperationAdapter-DisplayandOn/Off(PAC-SF40RM)□ Hand-heldWirelessRemoteController(PAR-FL32MA;req.PAR-FA32MA-E)□ WirelessSignalReceiverModule(PAR-FA32MA-E)□ LockdownBracketforHand-heldController(RCMKP1CB)□ Control/ServiceTool(PAC-SK52ST)

Outdoor Unit: PUY-A24NHA4 (-BS)

SEacoaSt ProtEctioN• ExternalOuterPanel:Phosphatecoating+Acrylic-Enamelcoating• FanMotorSupport:Epoxyresincoating(atedgeface)• SeparatorAssembly;ValveBed:Epoxyresincoating(atedgeface)• Screws(usedouterside):Zincnickelcoating5μm+Polyvinylidenechloridecoating

“blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants..

uNit oPtioN□ StandardModel……………..........…….................PUY-A24NHA4□ SeaCoast (BS)Model…….…………………..PUY-A24NHA4-BS

Indoor Unit: PEAD-A24AA4

Page 2: P-SEriES - MyLinkDrive-BS... · Specifications are subect to change without notice. ... gENEral FEaturES • Horizontal-ducted indoor unit features medium static pressure capability

SPECIFICATIONS: PCA-A24KA4 & PUY-A24NHA4

Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.

Notes:

cooling*RatedCapacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24,000Btu/hMinimumCapacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000Btu/hSEER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16.0Btu/h/WEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.0Btu/h/WTotalInput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,400W

Electrical requirementsPowerSupply . . . . . . . . . . . . . . . . . . . . 208/230V,1-Phase,60HzRecommendedFuse/BreakerSize. . . . . . . . . . . . . . . . . . . . . . 25A

VoltageIndoor-OutdoorS1-S2 . . . . . . . . . . . . . . . . . . . . . . AC208/230VIndoor-OutdoorS2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . .DC±24V

oPEratiNg coNDitioNSIndoorIntakeAir

Temp.OutdoorIntakeAir

Temp.

CoolingMaximum 95ºF(35ºC)DB

71ºF(22ºC)WB 115ºF(46ºC)DB

Minimum 67ºF(19ºC)DB57ºF(14ºC)WB 0ºF**(-18ºC)DB

**Withoptionalwindbaffleaccessoryinstalled.Ifnotinstalled,theminimumtemperaturewillbe23ºF(-5ºC)DB.

indoor unitMCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.63AFanTypexQuantity . . . . . . . . . . . . . . . . . . . . . . . . . Siroccofanx2FanMotorType . . . . . . . . . . . . . Direct-drivenDCBrushlessMotorBlowerMotor(ECM). . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.10F.L.A.FanMotorOutput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121WAirflow(Lo-Mid-Hi). . . . . . . . . . . . . . . . 512-636-742DryCFM 494-600-671WetCFMAirFilter . . . . . . . . . . . . . . . . . . . . . . . . .PolypropyleneHoneycombExternalStaticPressure. . . . . . 0.14-0.20-0.28-0.40-0.60"WGSoundPressureLevel(Lo-Mid-Hi) . . . . . . . . . . 30-33-37dB(A)SHF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.68MoistureRemoval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9pt./h

DimENSioNS uNit iNcHES / mmW 43-5/16/1,100D 28-7/8/732H 9-7/8/250Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73lbs./33kgExternalFinish. . . . . . . . . . . . . . . . . . . . . . .Galvanized-steelSheetFieldDrainpipeSizeO.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4"/32mm outdoor unitCompressor . . . . . . . . . . . . . . . . . . .DCInverter-drivenTwinRotaryMCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …18AMOCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30AFanMotor(ECM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.75F.L.A.SoundPressureLevel(Cooling). . . . . . . . . . . . . . . . . . . . . 48dB(A)

DimENSioNS iNcHES / mmW 37-3/8/950D 13+1-3/16/330+30H 37-1/8/943

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163lbs./74kgExternalFinish. . . . . . . . . . . . . . . . . . . . . . MunsellNo.3Y7.8/1.1RefrigerantType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410ARefrigerantPipeSizeO.D.GasSide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8"/15.88mmLiquidSide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8"/9.52mmMax.RefrigerantPipeLength. . . . . . . . . . . . . . . . . . . . . 165'/50mMax.RefrigerantPipeHeightDifference . . . . . . . . . . . . 100'/30mConnectionMethod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared

SPECIFICATIONS : PEAD-A24AA4 & PUY-A24NHA4 (-bS)

* rating conditions per aHri Standard Cooling|Indoor:80ºF(27ºC)DB/67ºF(19ºC)WBCooling|Outdoor:95ºF(35ºC)DB/75ºF(24ºC)WB

Page 3: P-SEriES - MyLinkDrive-BS... · Specifications are subect to change without notice. ... gENEral FEaturES • Horizontal-ducted indoor unit features medium static pressure capability

Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.

INDOOr UNIT PEAD-A24AA4 FAN PErFOrmANCE AND AIrFlOw rATES

0[0]

10[0.040]

20[0.080]

30[0.120]

40[0.161]

50[0.201]

60[0.241]

Airflow rate (m3/min)[cfm]

Ext

erna

l sta

tic p

ress

ure

(Pa)

[in.W

G]

10[353]

15[530]

20[706]

25[883]

30[1059]

0[0]

50[0.201]

100[0.401]

150[0.602]

Airflow rate (m3/min)[cfm]

Ext

erna

l sta

tic p

ress

ure

(Pa)

[in.W

G]

10[353]

15[530]

20[706]

25[883]

30[1059]

0[0]

10[0.040]

20[0.080]

30[0.120]

40[0.161]

50[0.201]

60[0.241]

70[0.281]

Airflow rate (m3/min)[cfm]

Ext

erna

l sta

tic p

ress

ure

(Pa)

[in.W

G]

10[353]

15[530]

20[706]

25[883]

30[1059]

0[0]

10[0.040]

20[0.080]

30[0.120]

40[0.161]

50[0.201]

60[0.241]

70[0.281]

80[0.321]

90[0.361]

Airflow rate (m3/min)[cfm]

Ext

erna

l sta

tic p

ress

ure

(Pa)

[in.W

G]

10[353]

15[530]

20[706]

25[883]

30[1059]

0[0]

50[0.201]

100[0.401]

150[0.602]

200[0.803]

Airflow rate (m3/min)[cfm]

Ext

erna

l sta

tic p

ress

ure

(Pa)

[in.W

G]

10[353]

15[530]

20[706]

25[883]

30[1059]

Limit

Low

Middle

High

Rated point

Limit

Low

Middle

High

Rated point

Limit

Low

Middle

High

Rated point

Limit

Low

Middle

High

Rated point

Limit

Low

Middle

High

Rated point

PEAD-A24AA4(External static pressure 35Pa [0.14 in. WG]) 208-230V 60Hz

PEAD-A24AA4(External static pressure 50Pa [0.2 in. WG]) 208-230V 60Hz

PEAD-A24AA4(External static pressure 70Pa [0.3 in. WG]) 208-230V 60Hz

PEAD-A24AA4(External static pressure 100Pa [0.4 in.WG]) 208-230V 60Hz

PEAD-A24AA4(External static pressure 150Pa [0.6 in. WG]) 208-230V 60Hz

Page 4: P-SEriES - MyLinkDrive-BS... · Specifications are subect to change without notice. ... gENEral FEaturES • Horizontal-ducted indoor unit features medium static pressure capability

Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.

DImENSIONS: PEAD-A24AA4

3-ø

2.9(

1/8)

mou

ntin

g ho

le

Air

filte

r

Ref

riger

ant p

ipin

gfla

re c

onne

ctio

n (li

quid

)

Liqu

id p

ipe

Gas

pip

e

ø9.

52 (

3/8)

ø15

.88

(5/

8)

Ven

tilat

ion

air

inta

ke ø

100(

3-15

/16)

knoc

k ou

t hol

e

AM

odel

1400

1100

PE

AD

-A24

, 30A

A4

PE

AD

-A36

, 42A

A4

GF

BC

DE

1000

1413

6015

0014

54

1154

1060

1112

00

1300

1358

1058

Sus

pens

ion

bolt

hole

4-14

x30(

9/16

X1-3

/16)

Slo

t

(O.D

.ø32

(1-1

/4))

Dra

in p

ipe

Dra

in p

ipe(

O.D

.ø32

(1-1

/4))

(Spo

ntan

eous

dra

inin

g)

Ter

min

al b

lock

(Rem

ote

cont

rolle

r tr

ansm

issi

on li

ne)

Ter

min

al b

lock

(Ind

oor/

Out

door

con

nect

ion

line)

Con

trol

box

Drain

pum

p

Ref

riger

ant p

ipin

gfla

re c

onne

ctio

n (g

as)

1

12

2

Dra

in p

ipe(

O.D

. ø32

(1-1

/4))

(E

mer

genc

y dr

aini

ng)

2xE

-ø2.

9(1/

8)

Air

inle

tA

irou

tlet

2X2-

ø2.

9(1/

8)

(4-1

5/16

125

120

120

57(2-1/4)

78(3-1/8)

200(7-7/8)

378(

12-7

/16)

Uni

t:mm

(in.)

(43-

5/16

)

(55-

1/8)

(57-

1/4)

(45-

7/16

)(4

7-1/

4)

(59-

1/16

)(5

3-9/

16)

(41-

3/4)

(39-

3/8)

(51-

3/16

)(5

3-1/

2)

(41-

11/1

6)

21(7/8)

(8-5

/16)

(5-3/8)135

153

(6-1

/16)

(2-1

1/16

)(5

-3/8

)(Sus

pens

ion

bolt

pitc

h)

21G

18(3

/4)

210

40(1-5/8) 40(1-5/8)

250(9-7/8)

40(1-5/8)

33(1-5/16)122(4-13/16)

D(Duct) 20(13/16)

100(3-15/16)X(E-1)=F 30(1-3/16)

100(3-15/16)

217(8-9/16)

41(1-5/8)

100(3-15/16)

356

(1/1

6)6713

6

732

(28-

7/8)

700

(27-

9/16

)32

(1-5

/16)

238(

9-3/

8)

10(7

/16)

23(15/16) 178(7-1/16)

643

(25-

3/8)

23(15/16)

C

B(Suspension bolt pitch)

A

10(7

/16)

57(2

-1/4

)

58(2-5/16)

15(5

/8)

Not

e 4

10 1212

80

330

449 54

320

5

990

ML

KJ

N12

00

1500H

N-ø

2.9(

1/8)

(4-7/16)(4-7/16)

(50-

7/16

)

(39)

(12-

5/8)

(13)

(1-1

5/16

)

(2-3

/16)

(59-

1/16

)

(47-

1/4)

-7/1

60

(2-9

/16

)

(11-

13/1

6)

(27-9/16)

(11-

13/1

6)(9

-7/8

~11-

13/1

6)

Less than 700

Less

than

300

(Act

ual l

engt

h)

65 0 -1

0

JK

X(L

-1)=

MJ

6(1

/4)

11211211(7/16)

K

50(2

)

250~

300

450(

17-3

/4)

50(2

)

H

777(

30-5

/8)

450(

17-3

/4)

Mor

e th

an 3

00

More than 20(13/16)

More than 10(7/16)

<ac

cess

ory>

Drai

n ho

se (I

.D.ø

32(1

-1/4

))

Acc

ess

door

Not

e2

Mak

e th

e ac

cess

doo

r at t

he a

ppoi

nted

pos

ition

pro

perly

for s

ervi

ce m

aint

enan

ce.

Cei

ling

surf

ace

Acc

ess

door

Req

uire

d sp

ace

for

serv

ice

and

mai

nten

ance

NOTE 1. Use M10 screw for the Suspension bolt (field supply). 2. Keep the service space for the maintenance at the bottom. 3. This chart indicates for PEAD-A24·30·36·42AA4 models,which have 2 fans. 4. In case of the inlet duct is used, remove the air filter (supplied with the unit), then install a filter (field supplied) at suction side.

Page 5: P-SEriES - MyLinkDrive-BS... · Specifications are subect to change without notice. ... gENEral FEaturES • Horizontal-ducted indoor unit features medium static pressure capability

Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.

3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822www.mehvac.com

FORM#PEAD-A24AA4-PUY-A24NHA4(-BS)-201302

DImENSIONS: PUY-A24NHA4 (-bS)

Cle

aran

ce A

rea