owner s operation and installation...

24
OWNER S OPERATION AND INSTALLATION MANUAL WARNING: Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier. This appliance may be installed in an aftermar- ket* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. Do not store, or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or gas supplier. HB20TL-1 HB30TL-1 HB20ML-1 HB30ML-1 Table of Contents Important Safety Information.................................2 Product Features.....................................................3 Proper Ventilation & Fresh Air ...............................4 Installation................................................................6 Operating Your Heater ...........................................10 Cleaning & Maintenance.......................................13 Trouble Shooting...................................................14 Specifications..........................................................17 Parts List.................................................................19 Warranty Information............................................22 BLUE FLAME VENT-FREE PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air For Combus- tion and Ventilation section on page 4 of this manual. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Refer to page 3. Installer: Please leave these instructions with the consumer. Consumer: Please retain these instructions for future use. A Division of Empire Comfort Systems,Inc. 918 Freeburg Avenue Phone : 618-233-7420 or 1-800-851-3153 Fax : 618-233-7097 or 1-800-443-8648 www.hearthrite.com Belleville,IL 62220

Upload: others

Post on 15-Jan-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

OWNER’S OPERATION AND INSTALLATION MANUAL

WARNING: Improper ins ta l la t ion,

adjustment, alteration, service or mainte-

nance can cause injury or property damage.

Refer to this manual for correct installation and

operational procedures. For assistance or

additional information consult a qualified

installer, service agency, or gas supplier.

This appliance may be installed in an aftermar-

ket* permanently located, manufactured

(mobile) home, where not prohibited by local

codes.

This appliance is only for use with the type of

gas indicated on the rating plate. This

appliance is not convertible for use with other

gases.

*Aftermarket: Completion of sale, not for purpose of

resale, from the manufacturer.

Do not store, or use gasoline or other flammable

vapors and liquids in the vicinity of this or any

other appliance.

WHAT TO DO IF YOU SMELL GAS

! Do not try to light any appliance.

! Do not touch any electrical switch; do not

use any phone in your building.

! Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s

instructions.

! If you cannot reach your gas supplier, call

the fire department.

Installation and service must be performed by a

qual i f ied ins ta l ler , serv ice agency or gas

supplier.

HB20TL-1

HB30TL-1

HB20ML-1

HB30ML-1

Table of Contents

Important Safety Information.................................2

Product Features.....................................................3

Proper Ventilation & Fresh Air...............................4

Installation................................................................6

Operating Your Heater...........................................10

Cleaning & Maintenance.......................................13

Trouble Shooting...................................................14

Specifications..........................................................17

Parts List.................................................................19

Warranty Information............................................22

BLUE FLAME VENT-FREE

PROPANE/LP GAS

SPACE HEATER

WARNING: This is an unvented gas-fired

heater. It uses air (oxygen) f rom the room

i n w h i c h i t i s installed. Provisions for

adequate combustion and ventilation air must

be prov ided. Refer to A i r For Combus-

tion and Ventilation section on page 4 of this

manual.

WARNING: I f the information in this

manual is not followed exactly, a f i re o r

e x p l o s i o n m a y r e s u l t causing property

damage, personal injury, or loss of life.

WATER VAPOR: A BY-PRODUCT OF UNVENTED

ROOM HEATERS

Water vapor is a by-product of gas combustion. An

unvented room heater produces approximately one

(1) ounce (30ml) of water for every 1,000 BTU’s

(.3KW’s) of gas input per hour. Refer to page 3.

Installer: Please leave these instructions with the

consumer.

Consumer: Please retain these instructions for

future use.

A Division of Empire Comfort Systems,Inc.

918 Freeburg Avenue

Phone : 618-233-7420 or 1-800-851-3153

Fax : 618-233-7097 or 1-800-443-8648

www.hearthrite.com

Belleville,IL 62220

Page 2: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

2

IMPORTANTSAFETY INFORMATION

Keep the appliance area clear

and f ree f rom combust ib le

materials, gasoline, and other

flammable vapors and liquids.

1. This appliance is only for use

with the type of gas indicated

on the rating plate. This

appliance is not convertible for

use with other gases.

2. Do not place propane/LP

supply tank(s) inside any

structure. Locate propane/LP

supply tank(s) outside.

3. If you smell gas

! Shut off gas supply.

! Do not try to light any appliance.

! Do not touch any electrical switch;

do not use any phone in your

building.

! Immediately call your gas supplier

from a neighbor’s phone. Follow

the gas supplier’s instructions.

! If you cannot reach your gas

supplier, call the fire department.

4. This heater shall not be

installed in a bathroom or

bedroom.

5. This heater needs fresh,

outside air ventilation to run

properly. This heater has an

Oxygen Depletion Sensor

(ODS) safety shutoff system.

The ODS shuts down the

heater if not enough fresh air

is available. See Fresh Air for

Combustion and Ventilation

pages 4 and 5.

6. Keep all air openings in front

and at the bottom of heater clear

and free of debris. This will

insure enough air for proper

combustion.

7. If heater shuts off. Do not

relight until you provide fresh

outside air. If heater keeps

shutting off, have it serviced.

8. Do not operate heater

! where flammable liquids or vapors

are used or stored

! under dusty conditions

WARNINGS

IMPORTANT: Read th is

owner’s manual carefully and

comple te ly be fore t ry ing to

assemble, operate, or service

this heater. Improper use of

this heater can cause serious

injury or death from burns,

f i r e , e x p l o s i o n , e l e c t r i c a l

shock, and carbon monoxide

poisoning.

Do not place clothing or other

flammable material on or near

the appliance. Never place any

objects on the heater.

Due to high temperatures, heater

s h o u l d b e k e p t o u t o f

traffic and away from furniture

and draperies.

Surface of heater becomes

very hot when running heater.

Keep children and adults away

from hot surface to avoid burns

or clothing ignition. Heater will

remain hot for a time after shuting

down. Al low surface to cool

before touching.

Ca re fu l l y supe rv i se young

children when they are in the

same room with heater.

Make sure gri l l guard is in

place before running the heater.

9. Turn off heater before using

furniture polish, wax, carpet

cleaner, or similar products. If

heated, the vapors from these

products may create a white

powder residue within burner

box or on adjacent walls or

furniture.

10. Do not use heater if any part

has been under water.

Immediately call a qualified

service technician to inspect

the room heater and to

replace any part of the control

system and any gas control

which has been under water.

11. Turn off heater and let cool

before servicing. Only a

qualified service person should

service and repair heater.

12. Operating heater above

elevations of 4,500 feet could

cause pilot outage.

13. To prevent performance, problems,

do not use propane/LP fuel tank of

less than 100 lbs. capacity.

DANGER: Carbon monoxide

poisoning may lead to death !

Carbon Monoxide Poisoning:

Early signs of carbon monoxide

poisoning resemble the flu with

headaches, dizziness, or nausea.

If you have these signs, the heater

may not be working properly. Get

fresh air at once! Have heater

serviced. Some people are more af-

fected by carbon monoxide than

others. These include pregnant

women, persons with heart or lung

disease or anemia, those under the

influence of alcohol, and those

at high altitudes.

Propane/LP Gas: Propane/LP gas

is odorless. An odor-making agent

is added to Propane/LP gas. The

odor helps you detect a Propane/LP

gas leak. However, the odor added to

Propane/LP gas can fade. Propane/

LP gas may be present even though

no odor exists.

Make certain you read and under-

stand all warnings. Keep this manual

for reference. It is your guide to safe

and proper operation of this heater.

WARNING: Do not use any

accessory not approved for

use with this heater.

WARNING: Any change to

this heater or its controls can

be dangerous.

Page 3: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

3

PRODUCT FEATURES

SAFETY DEVICEA standard requirement for all vent-free room

heaters. This heater has a pilot with an Oxygen

Depletion Sensor(ODS) safety shutoff system.

The ODS/pilot shuts off the heater if there is

not enough fresh air.

PIEZO IGNITION SYSTEMThis heater is equipped with a piezo ignitor.

This system requires no matches, batteries, or

other sources to light heater.

THERMOSTATIC HEAT

CONTROL ON THERMOSTATMODELSThese heaters have a control valve with a

thermostat sensing bulb. This results in the

greatest heater comfort and may result in

lower gas bills.

Figure1-Vent-Free Propane/LP Gas Heater

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An

unvented room heater produces approximately one

(1) ounce (30ml) of water for every 1,000 BTU’s

(.3KW’s) of gas input per hour.

Unvented room heaters are recommended as supple-

mental heat (a room) rather than a primary heat

source (an entire house). In most supplemental heat

applications, the water vapor does not create a

problem. In most applications, the water vapor en-

hances the low humidity atmosphere experienced

during cold weather.

Lower

Front

Panel

Heater

Cabinet

Control

Knob

Grill

Burners

LOCAL CODESInstall and use heater with care. Follow all local

codes. In the absence of local codes, use the

latest edition of National Fuel Gas Code ANSZ223.1,

also known as NFPA 54*.

*Available from :

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

QUALIFIED INSTALLING AGENCY

Installation and replacement of gas piping, gas utiliza-

tion equipment or accessories and repair and

servicing of equipment shall be performed only by a

qualified agency. The term “qualified agency” means

any individual, firm , corporation, or company that

either in person or through a representative is

engaged in and is responsible for (a) the installation,

testing, or replacement of gas piping or (b) the

connection, installation, testing, repair, or servicing of

equipment ; that is experienced in such work; that is

familiar with all precautions required, and that has

complied with all the requirements of the authority hav-

ing jurisdiction.

State of Massachsetts: The installation must be

made by a licensed plumber or gas fitter in the

Commonwealth of Massachusetts .

Sellers of unvented propane or natural gas-fired

supplemental room heaters shall provide to each

purchaser a copy of 527 CMR 30 upon sale of the unit.

In the state of Massachusetts, unvented propane or

nature gas-fired space heaters shall be prohibited in

bedrooms and bathrooms.

UNPACKING1. Remove heater from carton.

2. Remove all protective packaging applied to

heater for shipment.

3. Check heater for any shipping damage. If heater

is damaged, promptly inform dealer where you

bought heater.

Ignitor

Button

The following steps will help insure that water vapor

does not become a problem.

1. Be sure the heater is sized properly for the

application, including ample combustion air and

circulation air.

2. If high humidity is experienced, a dehumidifier

may be used to help lower the water vapor content

of the air.

3. Do not use an unvented room heater as the

primary heat source.

Page 4: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

4

FRESH AIR FORCOMBUSTION AND

VENTILATION

PROVIDING ADEQUATE

VENTILATIONThe following are excerpts from

National Fuel Gas Code. NFPA 54/

ANS Z223.1, Section 5.3. Air for

Combustion and Ventilation. All

spaces in homes fall into one of

the three following ventilation

classifications:

1. Unusually Tight Construction

2. Unconfined Space

3. Confined Space

The information on pages 4

through 6 will help you classify

your space and provide adequate

ventilation.

WARNING: This heater

shall not be installed in a

confined space or unusually

t ight construct ion unless

provisions are provided for

adequate combustion and

vent i la t ion a i r . Read the

f o l l o w i n g i n s t r u c t i o n s t o

insure proper fresh air for this

and other fuel-burning

appliances in your home.

Confined andUnconfined SpaceThe National Fuel Gas Code ANS

Z223.1 defines a confined space

as a space whose volume is less

than 50 cubic feet per 1,000 Btu per

hour (4.8 m 3 per kw) o f the

aggregate input rating of all

appliances installed in that space

and an unconfined space as a

space whose volume is not less

than 50 cubic feet per 1,000 Btu per

hour (4.8 m3 per kw) of the

aggregate input rating of all

appliances installed in that space.

Rooms communicating directly with

t h e s p a c e i n w h i c h t h e

appliances are installed*, through

openings not furnished with doors,

are considered a part of the

unconfined space.

This heater shall not be installed in

a confined space or unusually tight

construction unless provisions are

provided for adequate combustion

and ventilation air.

* Adjoining rooms are communicat-

ing only if there are doorless pas-

sageways or ventilation grills

between them.

WARNING: If the area in which the heater may be operated is smaller than that defined as an

unconfined space or if the building is of unusually tight construction, provide adequate combustion and

ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3

or applicable local codes.

Unusually Tight Construction

The air that leaks around doors and

windows may provide enough fresh

air for combustion and ventilation.

However, in buildings of unusually

tight construction, you must provide

additional fresh air.

Unusually tight construction is

defined as construction where:

a. walls and ceilings exposed to

the outside atmosphere have a

continuous water vapor retarder

with a rating of one per m (6×10-11

kg per pa-sec-m2) or less with

openings gasketed or sealed and

b. weather stripping has been

added on openable windows and

doors and

c. caulking or sealants are applied

to areas such as joints around

window and door frames, between

sole plates and floors, between

wall-ceiling joints, between wall

panels, at penetrations for plumbing,

electrical, and gas lines, and at

other openings. If your home meets

all of the three criteria above, you

must provide additional fresh air.

See Ventilation Air from Outdoors,

page 6. If your home does not

meet all of the three criteria above

see Determining Fresh-Air Flow for

Heater Location, page 5.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if you have a Confined or Unconfined Space*

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways

or ventilation grills between the rooms.

1. Determine the volume of the space (length×width×height).

Length×Width×Height= cu.ft. (volume of space)

Example: Space size20ft. (length)×16ft. ( width)×8ft. (ceiling height)=2560cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these

rooms to the total volume of the space.

2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) 50 cu. ft.=(Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) 50 cu.ft.=51.2 or 51.200(maximum Btu/Hr the space can support)

Page 5: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

5

WARNING: Rework worksheet, add-

ing the space of the adjoining

unconfined space. The combined spaces

must have enough fresh air to supply all

appliances in both spaces.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining

unconfined space. When ventilating to an

adjoining unconfined space, you must

provide two permanent openings: one within

12" of the ceiling and one within 12" of the

floor on the wall connecting the two spaces

(see options 1 and 2, Figure 2). You can also

remove door into adjoining room (see option

3, Figure 2). Follow the National Fuel Gas

Code NFPA 54/ANS Z223.1. Section 5.3, Air

for Combustion and Ventilation for required

size of ventilation grills or ducts

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an

unconfined space. You will need no additional fresh air ventilation.

Example:

Gas water heater 40,000 Btu/Hr

Vent free heater + 20,000 Btu/Hr

Total = 60,000 Btu/Hr

3. Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater Btu/Hr

Gas water heater* Btu/Hr

Gas furnace Btu/Hr

Vented gas heater Btu/Hr

Gas Fireplace logs Btu/Hr

Other gas appliances* + Btu/Hr

Total = Btu/Hr

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and

vents to the outdoors.

4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support)

Btu/Hr (actual amount of Btu/Hr used)

Example : 51,200 Btu/Hr(maximum the space can support)

60,000 Btu/Hr(actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the

maximum Btu/Hr the space can support.

You must provide additional fresh. Your options are as follows:

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined

space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From

inside Building, page 5.

B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6 .

C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

Figure 2 -Ventilation Air from Inside Building

Page 6: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

6

VENTILATION AIR

Ventilation Air From Outdoors

Provide extra fresh air by using

ventilation grills or ducts: You must

provide two permanent openings: one

within 12" of the ceiling and one within

12" of the floor.

Connect these items directly to the

outdoors or spaces open to the outdoors.

These spaces include attics and crawl

spaces. Follow the National Fuel Gas

Code NFPA 54/ANS Z223.1, Section 5.3.

Air for Combustion and Ventilation for

required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings

for inlet or outlet air into attic if attic has

a thermostat-controlled power vent.

Heated air entering the attic will activate

the power vent.

NOTICE: This heater is

intended for use as supplemental

heat. Use this heater along with

your primary heating system. Do

not install this heater as your

primary heat source. If you have

a central heating system, you

may run system’s circulating

blower while using heater. This

will help circulate the heat

throughout the house. In the

event of a power outage, you can

use this heater as your primary

heat source.

WARNING: A qualified

service person must install

heater. Follow all local codes.

CHECK GAS TYPE

Use only Propane/LP gas. If your

gas supply is not Propane/LP, do not

install heater. Call dealer where you

bought heater for proper type heater.

INSTALLATION NEEDS

Before installing heater, make sure

you have the items listed below.

! piping (check local codes)

! sealant (resistant to Propane/LP gas)

! equipment shutoff valve*

! ground joint union

! test gauge connection*

! sediment trap

! tee joint

! pipe wrench

*A CSA/AGA design-certified equip-

ment shutoff valve with 1/8" NPT

tap is an acceptable alternative to

test gauge connection. Purchase

the CSA/AGA design certified

equipment shutoff valve from your

dealer.

LOCATING HEATERThis heater is designed to be

mounted on a wall. You can locate

heater on floor, away from a wall.

An optional floor mounting stand is

needed. Purchase the f loor

mounting stand from your dealer.

See Accessories, page 17.

For convenience and efficiency,

install heater

! where there is easy access for

operation, inspection, and service

! in coldest part of room

An optional fan kit is available from

your dealer. See Accessories,

page 17. If planning to use fan,

locate heater near an electrical

outlet.

INSTALLATION

CAUTION: If you install the

heater in a home garage

! heater pilot and burner must

be at least 18 inches above

floor.

! locate heater where moving

vehicle will not hit it.

CAUTION: This heater

creates warm air currents.

These currents move heat

to wal l sur faces next to

h e a t e r . I n s t a l l i n g h e a t e r

next to vinyl or cloth wall

c o v e r i n g s o r o p e r a t i n g

heater where impurities (such as

tobacco smoke, aromatic candles,

cleaning fluids, oil or kerosene

lamps, etc.) in the air exist may

discolor walls.

WARNING: Never install

the heater! in a bedroom or bathroom.

! in a recreational vehicle.

! where curtains, furniture,

clothing, or other flammable

objects are less than 36 inches

from the front, top, or sides of

the heater.

! as a fireplace insert.

! in high traffic areas.

! in windy or drafty areas.

Figure 3 -Ventilation Air from Outdoors

Page 7: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

7

INSTALLATION

Figure 8 - Mounting Bracket

Clearances

Figure 7 - Removing Lower Front

Panel Of Heater

Figure 4 -Mounting Clearances As

View From Front Of Heater

WARNING: Maintain the

minimum clearances shown

in F igure 4 . I f you can ,

provide greater clearances from

floor, ceiling, and joining wall.

IMPORTANT: Vent-free

heaters add moisture to the

air. Although this is beneficial,

instal l ing heater in rooms

without enough ventilation air

may cause mildew to form

from too much moisture. See

Fresh Air for Combustion and

Ventilation, pages 4 and 5.

INSTALLING THERMOSTAT

SENSING BULB

For T-Stat Models Only

1. Pull out the sensing bulb from the

two clips located in the shippng

position according to the direction

as shown by the arrow. There is no

need to take out the two bulb clips.

2. Take out the bulb clip from the

hardware package and insert it into

the square hole and then insert the

sensing bulb into the bulb clip (see

Figure 5).

FASTENING HEATER TO WALL

Mounting Bracket

The mounting bracket is located

on back panel of heater (see

Figure 6). It has been taped there

for shipping. Remove mounting

bracket from back panel.

Removing Lower Front Panel Of

Heater

1. Remove two screws near bottom

corners of lower front panel.

2. Pull bottom of lower front panel

forward, then down (see Figure 7).

Methods For Attaching Mounting

Bracket To Wall

Only use last hole on each end

of mounting bracket to attach

bracket to wall. These two holes

are 16 inches apart from center.

Attach mounting bracket to wall

only in one of two ways:

1. Attaching to wall stud

2. Attaching to wall anchor

Attaching to Wall Anchor: This

method al lows you to attach

mounting bracket to hollow walls

(wall areas between studs) or to

solid walls (concrete or masonry).

2. Mark screw locations on

wall. (see Figure 8)

Note: Only mark last hole on

each end of mounting bracket.

Insert mounting screws through

these holes only.

3. Remove tape and mounting

bracket from wall.

WARNING: Maintain

minimum clearances shown in

Figure 4. If you can, provide

greater clearances from floor

and joining wall.

Figure 5 - Moving Thermostat

Sensing Bulb

Figure 6 -Mounting Bracket

Location

Attaching to Wall Stud: This method

provides the strongest hold. Insert

mounting screws through mounting

bracket and into wal l studs.

Decide which method better suits

your needs. Either method will provide

a secure hold for the mounting

bracket.

Marking Screw Locations

1. Tape mounting bracket to wall

where heater will be located.

Make sure mounting bracket is

level.

M o d e l H B 3 0 M L H B 3 0 T L

M o d e l H B 2 0 M L H B 2 0 T L

Page 8: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

8

INSTALLATION

Figure 11 - Mounting Heater Onto

Mounting Bracket

Figure 9 - Folding Anchor

Figure 10 - Popping Open Anchor

Wing For Thin Walls

Attaching Mounting Bracket to

Wall

Note: Wall anchors, mounting

screws, and spacers are in

hardware package. The hardware

package is provided with heater.

Attaching to Wall Stud Method

For attaching mounting bracket to

wall studs

1. Drill holes at marked locations

using 9/64" drill bit.

2. Place mounting bracket onto

wall. Line up last hole on each

end of bracket with holes drilled

in wall.

3. Insert mounting screws through

bracket and into wall studs.

4. Tighten screws until mounting

bracket is firmly fastened to

wall studs.

Attaching to Wall Anchor

Method

For attaching mounting bracket to

hollow walls (wall areas between

studs) or solid walls (concrete or

masonry)

1. Drill holes at marked locations

using 5/16" drill bit. For solid

walls (concrete or masonry),

drill at least 1" deep.

2. Fold wall anchor as shown in

Figure 9 below.

3. Insert wall anchor (wings

first) into hole. Tap anchor

flush to wall.

4. For thin walls (1/2" or less),

insert red key into wall

anchor. Push red key to

"pop" open anchor wings

(see Figure 10).

IMPORTANT: Do not

hammer key! For thick walls

(over 1/2" thick) or solid walls,

do not pop open wings.

5. Place mounting bracket onto

wall. Line up last hole on

each end of bracket with wall

anchors.

6. Insert mounting screws through

bracket and into wall anchors.

7. Tighten screws until mounting

bracket is firmly fastened to

wall.

Placing Heater On Mounting

Bracket

1. Locate two horizontal slots on

back panel of heater (see

Figure 11).

2. Place heater onto mounting

bracket. Slide horizontal slots

onto stand-out tabs on

mounting bracket.

Installing Bottom Mounting

Screws

1. Locate two bottom mounting

holes. These holes are near

bottom on back panel of

heater(see Figure 12).

2. Mark screw locations on

wall.

3. Remove heater from mounting

bracket.

4. If installing bottom mounting

screws into hollow or solid wall,

install wall anchors. Follow steps

1 through 4 under Attaching

To Wall Anchor Method. If

installing bottom mounting

screw into wall stud, drill

holes at marked locations

using 9/64" drill bit.

5. Replace heater onto mounting

bracket.

6. Place spacers between’

bottom mounting holes and

wall anchor or drilled holes.

7. Hold spacer in place with one

hand. With other hand, insert

mounting screw through

bottom mounting hole and

spacer. Place tip of screw in

opening of wall anchor or

drilled holes.

8. Tighten both screws until heater

is firmly secured to wall. Do

not over tighten.

! Note: Do not replace lower front

panel at this time. Replace lower

front panel after making gas

connections and checking for

leaks(see page 10) .

Figure 12 - Installing Bottom

Mounting Screws

Page 9: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

9

INSTALLATION

CONNECTING TO GAS SUPPLY

WARNING: A qualified

service person must connect

heater to gas supply. Follow all

local codes.

WARNING: This appliance

requires a 3/8" NPT (National

Pipe Thread) inlet connection

to the pressure regulator.

CAUTION: Never connect

h e a t e r d i r e c t l y t o t h e

propane/LP supply. This heater

requires an external regulator

(not suppl ied) . Insta l l the

external regulator between the

heater and propane/LP supply.

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is

an acceptable alternative to test gauge connection. Purchase the CSA/AGA

design-certified equipment shutoff valve from your dealer.

IMPORTANT: Install an equipment

shutoff valve in an accessible

location. The equipment shutoff

valve is for turning on or shutting

off the gas to the appliance.

Install sediment trap in supply line

as shown in Figure 14. Locate

sediment trap where it is within

reach for c leaning. Locate

sediment trap where trapped

matter is not likely to freeze. A

sediment trap traps moisture and

contaminants. This keeps them

from going into heater controls. If

sediment trap is not installed or is

instal led wrong, heater may

not run properly.

IMPORTANT: Hold pressure

regulator wi th wrench when

connecting it to gas piping and/or

fittings.

CAUTION: Use pipe joint

sealant that is resistant to

liquid petroleum (LP) gas.

Figure 14 -Gas Connection

The installer must supply an

external regulator. The external

regulator will reduce incoming gas

pressure . You mus t reduce

incoming gas pressure to between

11 and 13 inches of water. If you

do not reduce incoming gas

pressure, heater regulator damage

could occur . Insta l l external

regulator with the vent pointing

down as shown in Figure 13.

Pointing the vent down protects it

from freezing rain or sleet.

Figure 13 - External Regulator with

Vent Pointing Down

CAUTION: Use only new,

b lack i ron o r s tee l p ipe .

Internally-tinned copper tubing

may be used in certain areas.

Check your local codes. Use pipe

of large enough diameter to

allow proper gas volume to heater.

I f p ipe is too smal l ,

undue loss of pressure will occur.

Typical Inlet Pipe Diameters

All models up to 20,000 BTU’s use

3/8’’ or greater pipe;

All models 25,000 BTU’s and higher,

use 1/2” or greater pipe.

Installation must include an

equipment shutoff valve, union,

and plugged 1/8" NPT tap. Locate

NPT tap within reach for test gauge

hook up. NPT tap must be

upstream from heater (see Figure

14).

Apply pipe joint sealant lightly to

male threads. This will prevent

excess sealant from going into

pipe. Excess sealant in pipe could

result in clogged heater valves.

Page 10: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 0

Figure 15 -Equipment Shutoff Valve

INSTALLATION

CHECKING GASCONNECTIONS

WARNING: Test all gas

piping and connections for leaks after

installing or servicing. Correct all

leaks at once.

WARNING: Never use an open

flame to check for a leak. Apply a

mixture of liquid soap and water

to all joints. Bubbles forming

show a leak. Correct all leaks at

once.

Pressure Testing Gas Supply

Piping System

Test Pressures In Excess Of

1/2 PSIG (3.5 K Pa)

1. Disconnect appliance with its

appliance main gas valve

(control valve) and equipment

shutoff valve from gas supply

piping system. Pressures in

excess of 1/2 psig will damage

heater regulator.

2. Cap off open end of gas pipe

where equipment shutoff valve

was connected.

3. Pressurize supply piping

s y s t e m b y e i t h e r u s i n g

compressed air or opening

propane/LP supply tank valve.

4. Check all joints of gas supply

piping system. Apply mixture of

liquid soap and water to gas

joints. Bubbles forming show

a leak.

5. Correct all leaks at once.

6. Reconnect heater and equipment

shutoff valve to gas supply. Check

reconnected fittings for leaks.

Test Pressures Equal To or

Less Than 1/2 PSIG (3.5 K Pa)

1. Close equipment shutoff valve

(see Figure 15).

2. Pressurize supply piping system

by either using compressed air

or opening propane/LP supply

tank valve.

3. Check all joints from gas meter to

equipment shutoff valve (see

Figure 16).Apply mixture of liquid

soap and water to gas joints.

Bubbles forming show a leak.

4. Correct all leaks at once.

Pressure Testing Heater Gas

Connections

1. Open equipment shutoff valve

(see Figure 15).

2. Open propane/LP supply tank

valve.

3. Make sure control knob of

heater is in the OFF position.

4. Check all joints from equipment

shutoff valve to control valve

(see Figure 16 ). Apply mixture of

liquid soap and water to gas

joints. Bubbles forming show

a leak.

5. Correct all leaks at once.

6. Light heater (see Operating

Heater, pages 10 and 11 for

thermostat models or page 12

for non-thermostat models).Check

the rest of the internal joints for

leaks.

7. Turn off heater (see To Turn Off

Gas To Appliance, page 11 for

thermostat models or page

12 for non-thermostat models).

8. Replace lower front panel.

THERMOSTAT MODELS

!FOR YOUR SAFETY!READ BEFORE LIGHTING

WARNING: If you do not

fol low these instruct ions

exactly, a fire or explosion may

resu l t caus ing p roper ty

damage, personal injury or

loss of life.

A. When lighting the pilot, follow ,

these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for

gas. Be sure to smell next to

the floor because some gas is

heavier than air and will settle

on the floor .

WHAT TO DO IF YOU SMELL GAS

! Do not try to light any appliance.

! Do not touch any electric switch;

do not use any phone in your

building.

! Immediately call your gas

supplier from a neighbor’s

phone. Follow the gas

supplier’s instructions.

! If you cannot reach your

gas supplier, call the fire

department.

C. Use only your hand to push in

or turn the gas control knob.

Never use tools. If the knob

will not push in or turn by

hand, don’t try to repair it, call

a qualified service technician or

gas supplier. Force or attempted

repair may result in a fire or

explosion.

D. Do not use this appliance if any

part has been under water.

Immediately call a qualified

service technician to inspect

the appliance and to replace

any part of the control system

and any gas control which has

been under water.

Figure 16 -Checking Gas Joints

OPERATING YOUR HEATER

In the State of Massachusetts the

gas cock must be a T handle type.

The State of Massachusetts

requires that a flexible appliance

connector cannot exceed three

feet in length.

Page 11: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 1

Figure 17 - Control Knob In The

OFF Position

Figure 18 - Pilot

OPERATING YOUR HEATER

THERMOSTAT MODELS

!LIGHTING!INSTRUCTIONS

1. STOP! Read the safety

information on the side of

heater.

2. Check that gas supply to

heater is on.

3. Push in gas control knob

slightly and turn clockwise to the

OFF position.

NOTE: knob cannot be turned from

“PILOT” to “OFF” unless knob is

pushed in slightly. Do not use

force.

4. Wait five (5) minutes to clear

out any air. Then smell for

gas, including near the floor.

If you smell gas, STOP!

Follow “B” in the safety

information on the side of the

heater. If you do not smell

gas, go to the next step.

5. Push in gas control knob

slightly and turn

counterclockwise to

“PILOT/IGN” and depress for

five(5) seconds

NOTE: You may be running this

heater for the first time after hooking

up to gas supply. If so, the control

knob should be depressed for about

thirty (30) seconds. This will allow

air to bleed from the gas system.

6. With control knob pressed in,

push down and release the

ignitor button. This will light

pilot. If needed, keep pressing

ignitor button until pilot lights.

NOTE: If pilot does not stay lit,

refer to Troubleshooting, pages

14 through 16. Also contact a

qualified service person or gas

supplier for repairs. Until repairs

are made, light pilot with match.

To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in

for thirty (30) seconds after

lighting pilot. After 30

seconds, release control knob.

! If control knob does not pop

up when released, contact a

qualified service person or

gas supplier for repairs.

NOTE: If pilot goes out, repeat

steps 3 through 7. Wait one (1)

minute before lighting pilot again

8. Turn control knob

counterclockwise to

desired heating Level. The

main burner should light. Set

control knob to any heat level

between HI and LO.

This increases or decreases the

burner flame height. At times the room

may exceed the set temperature. If so,

the burner will shut off. The burner

will cycle back on when room tem-

perature drops below the set

temperature. The control knob can

be set to any heat level between HI

and LO. Selecting the HI setting will

cause the burner to remain fully on

without modulating down in most cases.

NOTE: the thermostat sensing bulb

measures the temperature of air near

the heater cabinet. This may not al-

ways agree with room temperature

(depending on housing construction.

installation location, room size, open

air temperatures, etc.), frequent use

of your heater will let you determine

y o u r o w n c o m f o r t l e v e l s .

! TO TURN OFF !GAS TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the OFF position.

2. Turn off all electric power to

the appliance if service is to

be performed.

SHUTTING OFF BURNER ONLY

(PILOT STAYS LIT)

Turn control knob clockwise

to the PILOT/IGN position.

!MANUAL LIGHTING!PROCEDURE

1. Remove lower front panel (see

Figure 7 page 7).

2. Follow steps 1 through 5

under Lighting Instructions.

3. With control knob pressed in,

strike match. Hold match to

pilot until pilot lights.

4. Keep control knob pressed in

for 30 seconds after lighting

pilot. After 30 seconds, release

control knob. Follow step 8

under Lighting Instructions.

5. Replace lower front panel.

The thermostatic control used on

these models differs from standard

thermostats. Standard thermostats

simply turn on and off the burner.

The thermostat used on this heater

senses the room temperature. The

thermostat adjusts the amount

of gas flow to the burner.

CAUTION: Do not try to

adjust heating levels by using

the equipment shutoff valve.

! THERMOSTAT !CONTROL OPERATION

Page 12: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 2

OPERATING YOUR HEATER

NON-THERMOSTAT MODELS

!FOR YOUR SAFETY!READ BEFORE LIGHTING

WARNING: If you do not follow

these instructions exactly, a fire or

explosion may result causing

property damage, personal injury or

loss of life.

A. When lighting the pilot, follow these

instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas.

Be sure to smell next to the floor

because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

! Do not try to light any

appliance.

! Do not touch any electric

switch; do not use any phone

in your building.

! Immediately call your gas

supplier from a neighbor’s

phone. Fo l low the gas

supplier’s instructions.

! if you cannot reach your gas

supplier, call the fire

department.

C. Use only your hand to push in

or turn the gas control knob.

Never use tools. If the knob will

not push in or turn by hand, don’t

try to repair it , call a qualified

service technician or gas supplier.

Force or attempted repair may

result in a fire or explosion.

D. Do not use this appliance if any

part has been under water.

Immediately call a qualified service

t e c h n i c i a n t o i n s p e c t t h e

appliance and to replace any part of

the control system and any gas

control which has been under water.

!LIGHTING!INSTRUCTIONS

1. STOP! Read the safety

information, on the side of

heater.

2. Make sure equipment shutoff

valve is fully open.

3. Push in control knob slightly

and turn clockwise to the

OFF position (see Figure 19).

4. Wait five minutes to clear out

any gas. Then smell for gas,

including near the floor. If you

smell gas.STOP! Follow "B" in the

safety information on the side of

heater. If you can’t smell gas, go

to the next step.

5. Push in and turn control knob

counterclockwise to PILOT

position. Press in control knob

for five(5) seconds.

Note: You may be running

this heater for the first time

after hooking up to gas supply.

If so, you may need to press

in control knob for 30 seconds.

This will allow air to bleed from

the gas system.

!TO TURN OFF!GAS TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the OFF position.

2. Turn off all electric power to the

appliance if service is to

be performed.

Shutting Off Burner Only (pilot

stays lit )

Slightly press in control, turn

control knob clockwise to the

PILOT position.

Figure 19 - Control Knob in The

OFF Position

Figure 20 - Pilot

6. With control knob pressed in,

push down and release the

ignitor button. This will light

pilot. if needed, keep pressing

ignitor button until pilot lights.

7. Keep control knob depressed

for ten(10) seconds after

lighting pilot. If pilot goes out,

repeat steps 5,6 and 7.

8. To select the desired heating

level, partially press down the

control knob slightly and rotate

counterclockwise . Release

the downward pressure on the

knob while continuing to turn

until the knob locks at the

desired setting position. Do not

operate between locked

positions.

1. Remove lower front panel (see

Figure 7 page 7)

2. Follow steps 1 through 5

under Lighting Instructions .

3. With control knob pressed

in, strike match. Hold match to

pilot until pilot lights.

4. Keep control knob pressed in

for 30 seconds after lighting

pilot . After 30 seconds, release

control knob. Follow step 8 under

Lighting Instructions.

5. Replace lower front panel.

!MANUAL LIGHTING!PROCEDURE

Page 13: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 3

Figure 21 - Correct Pilot Flame

Pattern

Figure 22 - Incorrect Pilot Flame

Pattern

BURNER FLAME PATTERNFigure 23 shows a correct burner

flame pattern. Figure 24 shows an

incorrect burner flame pattern. If

burner flame pattern is incorrect,

as shown in Figure 24.

! turn heater off (see To Turn Off

Gas To Appliance. page 12 for non-

thermostat models or page

11 for thermostat models)

! see Troubleshooting. (pages 14

through 16)

CLEANING ODS/PILOT AND

BURNER! Use a vacuum cleaner,

pressurized air or a small, soft

bristled brush to clean.

CLEANING BURNER

PILOT AIR INLET HOLE

We recommend that you clean theunit every 2,500 hours of operation or

every three months. We alsorecommend that you keep the burner

tube and pilot assembly clean andfree of dust and dirt. To clean these

parts we recommend using com-pressed air no greater than 30 PSl.

Your local computer store, hard-ware store. or home center may

carry compressed air in a can. Youcan use a vacuum cleaner in the

blow position. If using compressedair in a can, please follow the direc-

tions on the can. If you don’t followdirections on the can, you could

damage the pilot assembly.1. Shut off the unit, including the

pilot. Allow the unit to cool for at least thirty minutes.

2. Inspect burner, pilot for dust and dirt.

3. Blow air through the ports/slots and holes in the burner.

Also, clean the pilot assembly. A yel-low tip on the pilot flame indicates

dust and dirt in the pilot assembly.There is a small pilot air inlet hole

about two inches from where the pi-lot flame comes out of the pilot as-

sembly (see Figure 25). With the unitoff, lightly blow air through the air inlet

hole. You may blow through a drinkingstraw if compressed air is not available.

Figure 25 - Pilot Inlet Air Hole

CLEANING HEATER CABINET

Air Passageways! Use a vacuum cleaner or pressurized air to clean.

Exterior! Use a soft cloth dampened with

a mild soap and water mixture. Wipe the cabinet to remove dust.

Check pilot flame pattern and

burner flame pattern often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot

flame pattern. Figure 22 shows an

incorrect pilot flame pattern. The

incorrect pilot flame is not touching

thermocouple. This will cause the

thermocouple to cool. When the

thermocouple cools, the heater will

shut down. If pilot flame pattern is

incorrect, as shown in Figure 22.

! turn heater off (see To Turn

Off Gas To Appliance. page 12

for non-thermostat models or

page 11 for thermostat models.)

! see Troubleshooting. pages 14

through 16.

WARNING: Turn off heater

and let cool before servicing.

CAUTION: You must keep control

areas, burner, and circulating air

passageways of heater clean. In-

spect these areas of heater before

each use. Have heater inspected

yearly by a qualified service person.

Heater may need more frequent clean-

ing due to excessive lint from carpeting,

bedding material, pet hair, etc.

CLEANING AND

MAINTENANCE

WARNING: If yellow tipping

o c c u r s , y o u r h e a t e r c o u l d

produce increased levels of

carbon monox ide. I f burner

flame pattern shows yellow

tipping, follow instructions at

bottom of this page.

Notice: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles enter the

heater and burn causing brief

patches of orange flame.

Figure 24 - Incorrect Burner

Flame Pattern

Figure 23 - Correct Burner Flame

Pattern

INSPECTING BURNER

Page 14: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 4

TROUBLESHOOTING

Note : All troubleshooting

items are listed in order of

operation.

WARNING: Only a qualified

service person should service and

repair heater.

CAUTION: Never use a wire,

needle, or similar object to clean

ODS/pilot. This can damage

ODS/pilot unit.

OBSERVED PROBLEM

When ignitor button is pressed in,

there is no spark at ODS/pilot.

When ignitor button is pressed in,

there is a spark at ODS/pilot but no

ignition.

ODS/pilot lights but flame goes out

when control knob is released.

POSSIBLE CAUSE

1. Ignitor electrode is positioned

wrong.

2. Ignitor electrode is broken.

3. Ignitor electrode is not connected

to ignitor cable.

4. Ignitor cable pinched or wet.

5. Broken ignitor cable.

6. Bad piezo ignitor.

1. Gas supply is turned off or

equipment shutoff valve is closed.

2. Control knob not fully pressed in

while pressing ignitor button.

3. Air in gas lines when installed.

4. ODS/pilot is clogged.

5. Gas regulator setting is not correct.

6. Control knob not in PILOT position.

7. Depleted gas supply.

1. Control knob is not fully pressed in.

2. Control knob is not pressed in

long enough.

3. Equipment shutoff valve is not

fully open.

4. Thermocouple connection loose

at control valve.

5 P i l o t f l ame i s no t t ouch ing

t he rmocoup le . Th i s a l l ows

thermocouple to cool, causing pilot

flame to go out. This problem

could be caused by one or both

of the following:

A) Low gas pressure

B) Dirty or partially clogged ODS/pilot

6. Thermocouple damaged.

7. Control valve damaged.

REMEDY

1. Replace ignitor.

2. Replace ignitor.

3. Reconnect ignitor cable.

4. Free ignitor cable if pinched by

any metal or tubing. Keep

ignitor cable dry.

5. Replace ignitor cable.

6. Replace piezo ignitor.

1. Turn on gas supply of open

equipment shutoff valve.

2. Fully press in control knob

while pressing ignitor button.

3. Continue holding down control

knob. Repeat igniting operation

until air is removed.

4. Clean ODS/pilot (see Cleaning

and Maintenance. Page 13) or

replace ODS/pilot assembly

5. Replace gas regulator.

6. Turn control knob to pilot position.

7. Contact local propane/LP gas

campany.

1. Press in control knob fully.

2. After ODS/pilot lights, keep control

knob pressed in 30 seconds.

3. Fully open equipment shutoff valve.

4. Hand tighten until snug, then

tighten 1/4 turn more.

5. A) Contact local propane/LP gas

company.

B) Clean ODS/pilot (see Cleaning

and Maintenance. Page 13) or

replace ODS/pilot assembly.

6. Replace thermocouple.

7. Replace control valve.

Page 15: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 5

TROUBLESHOOTINGContinued

OBSERVED PROBLEM

Burner(s)does not l ight af ter

ODS/pilot is lit.

Delayed ignition of burner(s).

Burner backfiring during combustion.

Yellow flame during burner

combustion.

Slight smoke or odor during

initial operation.

Heater produces a whistling noise

when burner is lit.

Heater produces a clicking/ticking

noise just after burner is lit or

shut off.

White powder residue forming within

burner box or on adjacent

walls or furniture.

POSSIBLE CAUSE

1. Burner orifice is clogged.

2. Burner orifice diameter is too small

3. Inlet gas pressure is too low.

1. Manifold pressure is too low.

2. Burner orifice is clogged.

1. Burner orifice is clogged or

damaged.

2. Burner damaged.

3. Gas regulator defective.

1. Not enough air.

2. Gas regulator defective.

3. Inlet gas pressure is too low.

1. Residues from manufacturing

processes.

1. Turning control knob to HI position

when burner is cold.

2. Air in gas line.

3. Air passageways on heater

blocked.

4. Dirty or partially clogged burner

orifice.

1. Metal expanding while heating or

contracting while cooling.

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. turn into white

powder residue.

REMEDY

1. Clean burner orifice (see Cleaning

and Maintenance, page 13) or

replace burner orifice.

2. Replace burner orifice.

3. Contact local Propane/LP gas company.

1. Contact local Propane/LP gas company.

2. Clean burner (see Cleaning and

Maintenance, page 13) or replace

burner orifice.

1. Clean burner orifice (see Cleaning

and Maintenance, page 13) or

replace.

2. Replace burner.

3. Replace gas regulator.

1. Check burner for dirt and debris. If

found, clean burner (see Cleaning

and Maintenance, Page 13).

2. Replace gas regulator.

3. Contact local propane/LP gas company.

1. Problem will stop after a few hours

of operation.

1. Turn control knob to LO position

and let warm up for a minute.

2. Operate burner until air is removed

from line. Have gas line checked

by local Propane/LP gas company.

3. Observe minimum installation

clearances (Figure 4, p7).

4. Clean burner (see Cleaning and

maintenance, Page13) or replace

burner orifice.

1. This is common with most

heaters. If noise is excessive,

contact qualified service person

1. Turn heater off when using

furniture polish, wax, carpet

cleaner or similar products.

Page 16: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 6

TROUBLESHOOTING

Continued

WARNING: If you smell gas

! Shut off gas supply.

! Do not try to light any appliance.

! Do not touch any electrical switch; do not use any phone in your building.

! Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions.

! If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors.

Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new

carpet or textiles, etc., create fumes. These fumes may mix with combustion air and

create odors.

REMEDY

1. Ventilate room. Stop using odor

causing products while heater

is running.

2. Locate and correct all leaks(see

Checking Gas Connections,

page 10).

3. Refill supply tank.

1. Open window and/or door for

ventilation.

2. Contact local Propane/LP gas

company.

3. Clean ODS/pilot (see Cleaning

Page 13).

1. Locate and correct all leaks(see

Checking Gas Connections,

Page 10).

2. Replace control valve.

1. Take apart gas tubing and

remove foreign matter.

2. Locate and correct all leaks

(see Checking Gas Connections,

Page 10).

1. This is common with most

heaters. if noise is excessive,

contact qualified service person.

1. Refer to Air for Combustion and

Ventilation requirements, Page

4.

POSSIBLE CAUSE

1. Heater burning vapors from

paint, hair spray, glues, etc.

(See IMPORTANT statement

above).

2 . Gas leak. See Warn ing

Statement at top of page.

3. Low fuel supply.

1. Not enough fresh air is available.

2. Low line pressure.

3. ODS/pilot is partially clogged.

1. Gas leak. See Warning

Statement at top of page.

2. Control valve is defective.

1. Foreign matter between control

valve and burner.

2. Gas leak. See Warning

Statement at top of page.

1. Metal is expanding while heating

or contracting while cooling.

1. Not enough combustion/ventilation

air.

OBSERVED PROBLEM

Heater produces unwanted odors.

Heater shuts off in use (ODS operates).

Gas odor even when control knob is

in OFF position.

Gas odor during combustion.

Heater produces a clicking/ticking

noise just after burner is lit or shut off.

Moisture/condensation noticed on

windows.

Page 17: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 7

SPECIFICATIONS

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).

* For purposes of input adjustment.

ACCESSORIES

Purchase these heater accesso-

ries from your local dealer. If they

can not supply these accessories,

contact HearthRite for information.

You can also write to the address

listed on the front of this manual.

Btu(available)

Gas Type

Ignition

Pressure Regulator setting

Inlet Gas Pressure *(inches of water)

Maximum

Minimum

Dimensions, Inches (HxWxD)

Heater

Carton

Weight (pounds)

Heater

Shipping

HB20ML

10,500/20,000

Propane/LP Only

Piezo

8" W.C.

13"

11"

23 1/4×19 1/4×8

26 1/2×21 3/4×9 1/4

21

25

HB20TL

9,000/20,000

Propane/LP Only

Piezo

8" W.C.

13"

11"

23 1/4×19 1/4×8

26 1/2×21 3/4×9 1/4

23

27

HB30ML

15,000/28,000

Propane/LP Only

Piezo

8" W.C.

13"

11"

23 1/4×26 3/4×8

26 1/2×28 1/2×9 1/4

26

31

HB30TL

14,000/28,000

Propane/LP Only

Piezo

8" W.C.

13"

11"

23 1/2×263 /4× 8

26 1/2×28 1/2×9 1/4

28

33

FLOOR MOUNTING STAND

For locating heater on the floor,

away from a wall. Complete installa-

tion instructions provided with floor

mounting stand.

Optional FAN Kit

The optional fan kit, part HAB01

fits all models noted in this manual.

The fan has 3 settings ON/OFF/Auto.

The thermostat ical ly control led

HAB01mproves heater efficiency and

includes installation and operating

instructions.

REPLACEMENT PARTS

Note: Use only original replace-

ment parts. This will protect your

warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealer from

whom you purchased this product.

If they are unable to supply original

replacement part(s), call the num-

ber on the front of this manual. When

contacting your dealer or HearthRite,

have ready:

! your name

! your address

! model and serial numbers of

your heater

! how heater was malfunction-

ing

! type of gas used (propane/LP or

natural gas)

! purchase date

! warranty card

Usually, we will ask you to return the

defective part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this

product. If they can’t supply original

rep lacement par t (s ) , contac t

HearthRite at (800) 851-3153.

TECHNICAL SERVICE

You may have further questions

about installation, operation, or

troubleshooting. If so, contact

HearthRite at (800) 851-3153.

HAB01

A Division of Empire Comfort Systems,Inc.

918 Freeburg Avenue

Phone : 618-233-7420 or 1-800-851-3153

Fax : 618-233-7097 or 1-800-443-8648

www.hearthrite.com

Belleville,IL 62220

Page 18: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 8

ILLUSTRATED

PARTS BREAKDOWN

THERMOSTAT MODELS

HB20TL HB30TL

Page 19: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

1 9

PARTS LIST

THERMOSTAT

MODELS

HB20TL HB30TL

This list contains replaceable parts for your heater. When ordering replacement

parts, follow the instructions listed under Replacement Parts on page 17 of this

manual.

KEY

NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

24-1

24-2

25

26

27

28

29

HB30TL

PART NO.

MB10002E

MB09001E

MB11002E

ML086-01

ML087-01

ML088-01

ML069-02

SIT545-175

845-4.8x60Z

ML111-01

ML083-03

ML073-01

NRV81FI-8

96-4Z

ML079-01

MB40006

MB40022

MB40023

NBB30-000M1

ML101-01

ML091-07

ML103-01

ML104-01

ND1908x800x9

ND0803-8

ND0807-B2

ML105-01

6170-5Z

ML057-07

ML084-01E

ML060-01

MB28001

ML070-24E

ML071-02

ML072-01

ML065-01

PARTS AVAILABLE NOT SHOWN

DESCRIPTION

Cabinet Assembly

Lower Front Panel Assembly

Reflector Unit

Glass

Upper Glass Retainer

Lower Glass Retainer

Self Tapping Screw

Thermostat Valve Assembly

Screws

Thermostat Valve Base

Ignitor Assembly

Ignitor Line

Pressure Regulator

Washer

Self Locking Screw

Main Inlet Tube Assembly

ODS Line Assembly

Burner Inlet Tube Assembly

Burner

Burner Connector

Injector

Left Burner Support Bracket

Right Burner Support Bracket

ODS

Thermocouple

Ignitor Electrode

ODS Upper Deflector

NUT

Grill Guard

Middle Panel

Mounting Bracket

Hardware Kit

CSA/AGA Label

Gas Instruction Decal

Inside Warning Label

Thermostat Sensing Bulb Clip

QTY.

1

1

1

1

1

1

16

1

2

1

1

1

1

2

2

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

2

HB20TL

PART NO.

MB10005E

MB09002E

MB11004E

ML086-02

ML087-02

ML088-02

ML069-02

SIT545-130

845-4.8x60Z

ML111-01

ML083-03

ML073-01

NRV81FI-8

96-4Z

ML079-01

MB40006

MB40022

MB40023

NBB20-000M1

ML101-01

ML091-12

ML103-01

ML104-01

ND1908x800x9

ND0803-8

ND0807-B2

ML105-01

6170-5Z

ML057-09

ML084-02E

ML060-01

MB28001

ML070-22E

ML071-02

ML072-01

ML065-01

Page 20: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

2 0

ILLUSTRATED PARTS

BREAKDOWN

NON-THERMOSTAT MODELS

HB20ML HB30ML

Page 21: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

2 1

PARTS LIST

HB20ML

HB30ML

This list contains replaceable parts for your heater. When ordering replacement

parts, follow the instructions listed under Replacement Parts on page 17 of this

manual.

KEY

NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

28-1

28-2

29

30

31

32

33

HB30ML

PART NO.

MB10003E

MB09001E

MB11002E

ML086-01

ML087-01

ML084-01E

ML088-01

ML069-02

NV2020-14

ML073-01

MB16002

ML029-01

NRV81FI-8

96-4Z

ML079-01

MB40016

MB40018

MB40019

MB40020

MB40021

ML096-01

MB40017

NBB30-000M1

ML101-01

ML091-07

ML103-01

ML104-01

ND1908x800x9

ND0803-8

ND0807-B2

ML105-01

6170-5Z

ML057-07

ML083-03

ML060-01

MB28001

ML070-18

ML071-02

ML072-01

PARTS AVAILABLE NOT SHOWN

DESCRIPTION

Cabinet Assembly

Lower Front Panel Assembly

Reflector Unit

Glass

Upper Glass Retainer

Middle Panel

Lower Glass Retainer

Self Tapping Screw

Control Valve

Ignitor Line

Control Knob Assembly

Control Valve Fixed Nut

Pressure Regulator

Washer

Self Locking Screw

Main Inlet Tube Assembly

ODS Line Assembly

Lower Gas Outline Tube Assembly

Medium Gas Outline Tube Assembly

High Gas Outline Tube Assembly

4-Way Connector

Burner Inlet Tube Assembly

Burner

Burner Connector

Injector

Left Burner Support Bracket

Right Burner Support Bracket

ODS/pilot Assembly

Thermocouple

Ignitor Electrode

ODS Upper Deflector

NUT

Grill Guard

lgnitor Assembly

Mounting Bracket

Hardware Kit

CSA/AGA Label

Gas Instruction Decal

Inside Warning Label

QTY

1

1

1

1

1

1

1

16

1

1

1

1

1

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

1

1

1

1

1

HB20ML

PART NO.

MB10005E

MB09002E

MB11004E

ML086-02

ML087-02

ML084-02E

ML088-02

ML069-02

NV2020-14

ML073-01

MB16002

ML029-01

NRV81FI-8

96-4Z

ML079-01

MB40016

MB40018

MB40019

MB40020

MB40021

ML096-01

MB40017

NBB20-000M1

ML101-01

ML091-12

ML103-01

ML104-01

ND1908x800x9

ND0803-8

ND0807-B2

ML105-01

6170-5Z

ML057-09

ML083-03

ML060-01

MB28001

ML070-16

ML071-02

ML072-01

Page 22: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater

2 2

Page 23: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater
Page 24: OWNER S OPERATION AND INSTALLATION MANUALcdn-tp2.mozu.com/11590-15709/cms/files/HB2030_LP_User_Manual.pdf · PROPANE/LP GAS SPACE HEATER WARNING: This is an unvented gas-fired heater