Tamson founded in 1878
• P.M. Tamson bv founded in 1878 by Mrs. Tamson in the Hague, the Netherlands.
• Distribution of laboratory supplies initially.• From 1950’s also manufacturing Tamson thermostatic baths and
circulators.• In 1992 sold to Fisher Scientific USA.• Fisher sold assets of manufacturing of Tamson Instruments in August
1998 – Fisher kept sales of general laboratory supplies.• Assets were put in new company – Labovisco bv.• 2004 Labovisco is renamed in Tamson Instuments bv.• 2008 Moved to new building in Bleiswijk which is own property
3
Aug. 2011
Tamson focuses 100% on instruments
• Privately owned by a group of 2 shareholders.• Headquarters and manufacturing in Bleiswijk, the
Netherlands.• Engineering, final assembly, sales and marketing done by
the Tamson organization.• Basic manufacturing outsourced to third parties.
4
Aug. 2011
Markets
5
Chemical industry
15%Bio industry
3%Quality&testing
7%ASTM oil – testing
75%
Aug. 2011
Why Tamson (key benefits)?Price valueStainless steel, TeflonReliabilityRobustnessAccurate controlSafety features130 years of experienceProducts conform to CE regulationDynamic company, easy to communicate
6
Aug. 2011
Competition
JulaboHaake Neslab (Thermo Scientific)HuberLaudaGrant, Techne, Lawler, FTS,Cannon InstrumentsKoehler InstrumentsPolyScience
7
Aug. 2011
Results since 1998 have been good
• Since 1998 growth in turnover has been some 5..10% per year.
• More then 60 dealers and distributors around the world.• Product portfolio has grown significantly. First we have
added coolers and circulators. Now we are adding calibration baths and products for petrochemical market.
• Continuous intensive investments in research & development and product improvement.
• Supplier of OEM-units.
8
Aug. 2011
Tamson product portfolio Circulators and water baths
Heating Cooling
Viscometer baths (ASTM D445, IP71) High temperature Low temperature
Accessories Bath fluids Viscometers capillaries (ASTM D445, D2171), holders and hanger 8-channel stopwatch ASTM thermometers (ASTM E1) and holders Digital Contact thermometers for ASTM D445 Reference standards Performance pump Tubing and manifold
Other Petrochemical Equipment (NEW) Calibration baths (NEW)
9
Aug. 2011
-80°C .. 250°C
Heating CirculatorsApplications
10
Pre heating samples Thermometer calibration
Sensor calibration
Experiments
Aug. 2011
Heating Apparatus and application
(High temperature)
11
Tamson Bracket (TB)
Tamson Circulator (TCxx)
Aug. 2011
Tamson Bracket (TB)
Completely stainless steel Width can be adjusted from 186-422 mm Auto tuning, high precision Heater 1100W Pump 7 L/min Easy to operate Fluid level detection Cooling coil* Heater 1600W* RS232* *Optional
12
General purposeTo replace old thermostatic unitsHeating of special bath which the customer is already using.
Aug. 2011
Tamson Circulator TCxxbTC6b, TC10b, TC20b
Bath stainless steel 6,10 or 20ltrs Range ambient .. 200°C Level indication Bath drain Cooling coil Levelling platform* RS232* *Optional
13
Applications:Heavy dutyQuality testingWork benchSmall footprintGeneral purpose
Aug. 2011
Tamson Circulators TCxxb
14
TC6b, TC10b and TC20b can be used as:Circulator through external circulationWater baths for all kind of applications
Very strong levelling platform anchored in the 4 corners of the bath.
Aug. 2011
15
Tamson Circulator TCxxTC16, TC40 and TC58
Bath stainless steel Cooling coil Precise control Temperature range from ambient
up to 250°C Pump 7,5 L/min Auto tune, high precision Display readout in 0.1°C (controller
has a accuracy of 0.01°C) Levelling platform* RS232* *Optional
Applications:Heavy dutyQuality testingLarge volumesHigh temperatures
TC16
16 litersTC40
40 liters TC58
58 liters
Aug. 2011
16
Tamson Circulator TC1616 liters bath
Options RS232 communication (readout of
0.01°C with free Tamson software). Remote PT100 Additional heater 1500W Bath drain (standard included) Pressure/suction pump Performance pump 16 L/min Levelling platform
Can be used as a circulator and a water bath.
Aug. 2011
17
Tamson Circulators TC40/TC5840/58 liters bath
Options RS232 communication (readout of 0.01°C
with free Tamson software). Remote PT100 Bath drain (standard included) Pressure / suction pump Performance pump 16 L/min Levelling platform + lid Gabled lid (so no condensation in samples). Top lid with cover of 2 sets of 9 rings Top lid with cover of 6 sets of 6 rings
Can be used as a circulator and a water bath.
Aug. 2011
18
Heat removal circulators (Low temperature)
TLC10, TLC15, TLC30, TLC40, TLC80, TLC80-DP and TLC90.
Ambient .. -90°CRS232 communicationExternal circulationBath
Drain Level indication
Aug. 2011
19
Heat removal(A few applications)
Cloud & Pour
Point
Flash Point
Viscosity
Circulation
General Laboratory
-Experiments
-Refractometers
-Rotary Evaporators
-Etc.
Cold Filter Plugging Point
Aug. 2011
Tamson Low-temperature Circulator TLC10-3
Stainless steel -10..60°C
Optional -10..150°C Stability better than ± 0.05°C Bath drain Level detection RS232, free software Can be used as small bath Bath volume 3 L Opening 40 x 120 mm Depth bath 150 mm Pump 7 L/min Excellent price value ratio
20
ReliableAuxilary temperature controlSmall footprintRapid cooling downVery quietPrecise controlCooling of other equipment like refractometers, thermostatic baths, viscometer baths, flashpoint, distillation, etc.
Aug. 2011
Tamson Low-temperature Circulator TLC15-5, TLC30-5
Stainless steel -15..60°C, -30C..60°C
Optional -15..150°C Stability ± 0.05°C Bath drain Level detection RS232, free software Can be used as small bath Bath volume 5 L Opening 85 x 150 mm Depth bath 150 mm Pump 7 L/min
21
ReliableAuxilary temperature controlSmall footprintRapid cooling downVery quietPrecise controlCooling of other equipment like refractometers, thermostatic baths, viscometer baths, flashpoint (Abel), etc.
Aug. 2011
Tamson Low-temperature Circulator TLC40-14, TLC80-14, TLC90-14
Stainless steel -40°C, -80°C, -90°C .. Ambient. Stability ± 0.05° Bath drain Level detection Bath volume 14 L Opening 240 x 160 mm Depth bath 150 mm Pump 7 L/min RS232* Suction / pressure pump* Performance pump 16 L/min, max 1
bar* Optional*
22
Bath or circulation.Replace tap water. High C&P(D97) (TLC40)C&P(D97), CFPP (TLC80, TLC90)Flash point (Abel, IP170) TLC40.Connect multiple laboratory equipment.Distillation
Aug. 2011
Tamson Low-temperature Circulator TLC80-14DP
Stainless steel -80°C .. Ambient Stability ± 0.05° Bath drain Level detection Bath volume 14 L Opening 240 x 160 mm Depth bath 150 mm Pump 10 L/min Economical mode RS232* Suction / pressure pump* Performance pump 16 L/min, max 1 bar* Optional*• Heat removal 150W @ -80°C
23
Bath or circulation.C&P(D97), CFPPConnect multiple laboratory equipment with only one cooler.Practical use -80 .. -40°C
Aug. 2011
Pump alternatives
24
Aug. 2011
Visibility / Viscosity Baths ASTM D445 / IP 71
A few Applications
25
Thermometer calibration
Sensor calibration
Kinematic Viscosity
Other examples:- Chemical prosesses- Density (ASTM 1401)- Reaction rate
Aug. 2011
Tamson Viscosity
TV2000 / new TV4000mkII / new TV7000mkII
Stainless steel Ambient .. 230°C 20, 40 or 70 L bath volume Stability ± 0.01°C (display also 0.01°C) RS232 + drain standard Large (double) windows Cooling coil + overflow outlet Two holes for separate ASTM reference
thermometer Top lid for use with viscometer holders Fine adjustable offset Fully ASTM D445 TV7000 fully ASTM D2162 Backlight (optional) Detachable window to clean inside
window
26
Designed for ultra precise measurement:Viscosity, calibration, crystal growing, density, reaction rate
Aug. 2011
Tamson ViscosityTV12
Only 12 liter bath volume Stability: ± 0.005°C Small footprint: 32 x 34 cm Span 15 .. 120°C (with external TLC10-
3 through cooling coil) Optional Span 15 .. 150°C
ASTM D 445 Display readout: 0.01°C Lid with 4 holes for viscometers Built-in illumination (LED LIGHTS) Detachable window to clean inside
window Stainless steel Hole for separate ASTM reference
thermometer
27
Designed for ultra precise measurement:Viscosity, calibration, sensor calibration, density, reaction rate
Aug. 2011
Tamson ViscosityTV12
1. RS2322. Motor Fuse3. Fan4. Built-in cooling coil (to work below
ambient)5. Overflow outlet6. Mains Connector7. Bath drain
28
4
12
3
5
6
7
4
Aug. 2011
Tamson ViscosityTV12
29
•Unique recovery time after temperature dip (caused by viscometers).
•3 times quicker than conventional bath.
•This is strictly conform to ASTM D 445.
Aug. 2011
Tamson Viscosity
Semi - automated TV2000AKV
Stainless steel Stability ± 0.01° Ambient .. 120°C 20 L bath volume Measuring head Ubbelohde or
Cannon Fenske System can store 10 viscometers
constants Built-in timer Infra red detection Transparent / dark samples
Fully ASTM D445
30
Automated Kinematic Viscosity measurement
Aug. 2011
Tamson Viscosity
TV2500
Stainless steel Stability ± 0.02° Ambient .. 100°C 4 positions for viscometer holder Good visibility 25 L bath volume Cooling coil RS232 Can be used for ASTM D1298
with special cover and 500 mL cylinders
31
Viscosity measurementPulp, en polymer industrySensor calibrationBitumen
Aug. 2011
Tamson Viscosity Low Temperature
TV4000LT / TV7000LT
40 ltr or 70 ltr bath Stability ± 0.02°C (0.01°C display) RS232 -40°C .. +100°C Top lid for use with viscometer
holders Fine adjustable offset Fully ASTM D445 Excellent homogenety Energy saving Window heating Can be used with Schott measuring
head. Standard drain
32
Designed for ultra precise measurement at low temperature:Viscosity, calibration, density, reaction rate
Aug. 2011
Tamson Viscosity Low Temperature NEW TV12LT
33
Only 15 liter bath volume.ASTM D445Display readout 0.01°C (0.001°C optional)Lid with 4 holes for viscometersBuilt-in illumination Built-in coolingTemperature range from -50 up to
+80°C. Detachable window to clean inside windowWindow heatingStainless steelRS232Holes for separate ASTM reference thermometerMore than 50 units since production started in 2011
Aug. 2011
Tamson Viscosity Low Temperature
TLV25
25 ltrs bath Stability ± 0.04°C RS232 Top lid for use with 3
viscometer holders Complies to ASTM D445 Window heating Built-in illumination
34
Designed for viscosity measurement at low temperatureOperates down to -80°C Need an external cooler like the KV40 or KV80
Aug. 2011
Tamson Viscosity Low Temperature
Cold probe cryostat
KV40 probe -40°C KV80 probe -80°C 2.5 mtr flexible hose Compact probe 50 x
200mm Easy operation
35
The probe can be immersed directly in a fluid Applies heat removal on a spotCan be used together with the TLV25.
Aug. 2011
Accessories
Bath fluid Viscosity accessories 8-Channel Stopwatch Backlight illumination ASTM Thermometers Digital Contact
Thermometer Reference Standards Performance pump Tubing Manifold
36
Aug. 2011
Bath fluid
Mineral oil (range 80 … 150°C)
Silicone oil transparent (range 20 … 150°C) (range 80 … 150°C) (range 80 … 250°C)
Silicone oil opaque Range 80 … 250°C
Important viscosity ≤10 cSt
37
Aug. 2011
Viscosity AccessoriesViscometer capillaries
Cannon Fenske Routine Cannon Fenske Opaque U-Tube (Ostwald) Routine U-Tube (Ostwald) Opaque Ubbelohde Baume Vigneron Houillon S.I.L. Zeitfuchs Ubbelohde (TV2000-AKV) Cannon Fenske (TV2000-AKV) Other types on request
38
Standard Calibration Certificate
Optional UKAS certificate*
Aug. 2011
Viscosity AccessoriesViscometer holders
39
• Insulated handle, easy to grab at high working temperatures• Stainless steel• Ring to hang out
Cannon Fenske Opaque
Cannon Fenske Routine
Utube (Ostwald) Routine
Utube (Ostwald) Opaque
Ubbelohde
Pinkevitz Long
Pinkevitz Short
Aug. 2011
Viscosity AccessoriesVisco hanger
• Stainless steel• Leakage tray• Easy drainage• 7 viscometer tubes• 51 x 28 x 49 cm
40
Aug. 2011
8-Channel stopwatch
• 8 channel
• Easy to operate
• Long battery life
• Uses simple 9V block
• Keeps value in memory after power off
• 0.01 sec resolution
• Saves bench space
• Optional Calibration Certificate
41
Aug. 2011
Backlight Illumination
Z41 (TV2000, TV4000 TV4000LT, TV2500, TV2000-AKV)
Z71 (TV7000, TV7000LT)
42
To be used when measurements have to be followed visually!!
Aug. 2011
ASTM Thermometers
43
• These thermometers comply with the ASTM E1.
• The glass thermometers are suitable for official calibration.
• All thermometers have a sub division of 0.05C (0.1F) and are equipped with an ice-point scale.
• To protect the thermometer for mechanical damage a stainless steel holders can be supplied
Aug. 2011
Tamson Thermometer 3 decimals TT-3
44
Complies to IEC 751Accuracy of ± 0.01°CCalibrated of 0.015°CResolution of ± 0.001°C.Substitute for the commonly known mercury thermometerFree Tamcom softwareRange from -100 .. +250°CProtective blue suitcaseConforms to new requirements of ASTM
Aug. 2011
• Sensor element PT100 (Thermistor or PT100)• Display resolution 0.001°C (0.01°C)• Accuracy better than ±0.015°C (±0.015°C)• Linearity ±0.01°C (±0.01°C)• Fast responsetime 3sec (<6 sec)• Annual drift <± 0.001°C (<± 0.01°C)
D445
Viscosity Calibration Standards Primary Standard Conforms to ASTM D2162 ISO 17025 & ISO Guide 34 certified under UKAS Values certified 20, 25, 40, 50 and 100°C Up to 2 Years Shelf life 0.5 liter bottles Other ASTM references on request (e.g. TAN, TBN, Flashpoint,
CRM.)
45
To be used as a reference standard for viscosity measurements!
Aug. 2011
See our extensive database at www.tamson.com
ASTM Equipment A few products
46
Kinematic Viscosity (ASTM D445/ASTM D446)
Copper Corrosion (ASTM D130)
Density by hydrometer method (ASTM D1298, D287)
LPG Sampling
Aug. 2011
ASTM D130 & D4048Copper Corrosion
47
Range from +5°C..250°C6 positionsHolders for test cylinderHolders for test tubesStandard drainAll accessories are supplied by Tamson.Can also be used as circulator
Aug. 2011
ASTM D1265, ISO EN 4057LPG Sampling
48
Comform EU 1999/36EC and ADR regulation (acc. ADR medium nr.1965).Stainless steel 1.4541600, 2300 and 3800 ml capacityII and CE laser marking, sealableTeflon coating is optionalAdditional adapters availableEasy internal cleaningCompletely acetone resistantWe have certificates for whole product (not a part of it) allowing to use our tanks in all EU countries.Strong base, impossible to knock over the containerSampling pump optional
Aug. 2011
ASTM D1298, D287Density by hydrometer method
49
Solid/firm frameClear view on hydrometerEasy cleaning & drainageHigh quality glassLeakage trayDouble wall cylindersCooling circulatorRange from +5°C .. +100°C
Aug. 2011
ASTM D1796 & ASTM D4007Waterbath to preheat the cones
50
Range from +5°C..250°C9 positionsStandard drainWith the levelling platform you can immerse the centrifuge cones in the vertical position to the 100-mL markCan also be used as circulator
Aug. 2011
ASTM D2162Calibration of Master Viscometers
(calibration long thermometers and temp. sensors)
51
Ultra stable +/- 0.005°CIntegrated coolingStainless steel bathHeated windowsRS232 communication0.001°C readoutRange from +10°C up to +60°CMaster viscometer + holders availableHolders + levelling platform for thermometers available.This bath is unique in the worldProduct for National Calibration labs
Aug. 2011
Calibration baths
52
Ultra stable +/- 0.005°CStainless steel bathOptional 0.001°C readoutRange from +10°C up to +120°C for TV12Range from +10°C up to +230°C for TV4000mkII DCRange from +10°C up to +120°C for TV12Range from -50°C up to +100°C for TV12LTCustom holders, platform and blocks possible
TV12
TV12LTTV4000MKII-DC
Calibration blocks
Custom design
Aug. 2011
2 times the accuracy when using calibration block
Aug. 2011
53
Calibration bathsTV12LT
54
Ultra stable +/- 0.01°CStainless steel bathOptional 0.001°C readoutRange from -40°C up to +80°C for TV12LTIntegrated coolingHeated windowsHolders + levelling platform for thermometers availableCalibration blocks available
Aug. 2011
Calibration bathsTV16000
55
Ultra stable +/- 0.005°CIntegrated coolingStainless steel bathHeated windows0.001°C readoutRange from +10°C up to +60°CHolders + levelling platform for thermometers available.This bath is unique in the worldProduct for National Calibration labs
Aug. 2011
Calibration bathsTV7000/TV7000LT
56
Ultra stable +/- 0.01°CStainless steel bath0.001°C readout optionalFor long thermometersHolders + levelling platform for thermometers available.RS232 communicationTV7000 range from ambient up to 230°CTV7000LT range from -40°C up to 100°C
Integrated coolingHeated windows
Aug. 2011
Tamcom• Free download from www.tamson.com• Auto detect Tamson equipment• Zoom function• Export as picture or CSV• Min max value• Realtime display• Program setpont curve
Aug. 2011
57
Send setpoint file to TLC30
Temperature LoggingSetpoint
Real time
New development
Aug. 2011
• Thermometer E20
• Digital Vacuum pump
• TLC80 - TLC40
• TLH80 – TLH40
• Sensor Density, dynamic viscosity, kinematic viscosity
• Controller Unit
58
Thermometer E20
Aug. 2011
59
• 3 digits• Stand alone• Full ASTM D445 – E20-
9• Multiplex up to 8
sensors• Readout on LCD• 6 point calibration• Free Tamcom software
Digital Vacuum pumpProvides constant vacuum
Aug. 2011
60
• 0 .. 350mm Hg• High accuracy +/- 0.5mm Hg• ASTM D2171 standard test for
viscosity of asphalt by vacuum capillary viscometer
• Can be offered with every manual viscometer bath
• Wide range input 110 .. 230V 50~60Hz
TLC80 – TLC40TLH80 - TLH40
Aug. 2011
61
- TLC = bath circulator- TLH circulate only- Single stage: -40°C- Dual stage: -80°C- Based on special
pump, 800mBar- Multiple safety
features:- First stage- 2nd stage
- Fast cooldown, -80 in 30 minutes
Introduction
• TLC80 renewed Dec 2011
• TLH80 july 2012 (Achema)
• TLC40 renewed Feb 2011
• TLH40 july 2012 (Achema)
Aug. 2011
62
Sensor D2KVDensity, dynamic viscosity, kinematic viscosity
• Based on resonating finger• Accuracy conforms to D445• 4 parameters:
– Temperature– Density– Dynamic and Kinematic Viscosity
• Dynamic and Kinematic viscosity• Range 0 .. 100 cSt, 100 .. 100 cSt• Temp range -40 .. 250°C• 10 ml Sample
Aug. 2011
63
Controller Unit
Aug. 2011
64
• Ultra accurate temperature control• Unit includes drivers heating both
• AC 115 .. 230V• DC output
• 0.001 resolution/sec on DC control• Readout 0.001°C• PT100• PID parameters• RS232 control
Thank you for your attention