mr . steam ® Feel Good Inc. ® Over Temperature Alarm and Shut Off Device For CT Day Spa & Commercial Steam Rooms Model CU-HTC Installation and Operation Manual _______________________________________ IMPORTANT: LEAVE THIS MANUAL WITH THE OWNER/OPERATOR OR ATTENDANT _______________________________________

Upload: others

Post on 24-Oct-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam®

Feel Good Inc.®

Over Temperature Alarmand Shut Off Device

For CT Day Spa & Commercial Steam RoomsModel CU-HTC

Installation and Operation Manual

_______________________________________IMPORTANT:

LEAVE THIS MANUAL WITH THEOWNER/OPERATOR OR ATTENDANT_______________________________________

Page 2: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

1

mr.steam® CU - H T C Installation & Operation Manual

TABLE OF CONTENTS

General Information . . . . . . . . . . . . . . . .2

Device Kit Contents . . . . . . . . . . . . . . . .2

Dimensions . . . . . . . . . . . . . . . . . . . . . . .3

Device Operation . . . . . . . . . . . . . . . . . .3––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

CU COMMERCIAL STEAMBATH SYSTEM

Device Installation . . . . . . . . . . . . . . . .4

CU Wiring Diagram . . . . . . . . . . . . . . .5

Typical Installation of CU Generator,Steamhead & Device . . . . . . . . . . . . . .5

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

CT DAY SPA SYSTEM

Device Installation . . . . . . . . . . . . . . . .6

CT Wiring Diagram . . . . . . . . . . . . . . . .7

Typical Installation of CT Generator,Steamhead & Device . . . . . . . . . . . . . .7

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Clear Temper Proof Cover Installation . .8

Device Sensor Installation . . . . . . . . . . .9

Calibration of Device Sensor . . . . . . . .10

Message Table . . . . . . . . . . . . . . . . . . .10

Monthly Checklist . . . . . . . . . . . . . . . .10

Warranty . . . . . . . . . . . . . . . . . . . . . . . .10

IMPORTANT! This Temperature Hi-limit Safety Device is for commercial steam rooms.Do not install or operate this control without reading the instructions provided.

For a replacement copy of instructions call 800-767-8326.

PUR 100562 REV 6.19

IMPORTANT NOTE: As you follow these instructions, you will notice warning and caution symbols. This informationis important for the safe and efficient installation and operation of this control. These are types of potential hazardsthat may occur during installation and operation:

signals a situation where minor injury or product damage may occur if you do not follow instructions.

states a hazard may cause serious injury or death if precautions are not followed.

mr.steam Sussman-Automatic Corporation® [email protected] www.mrsteam.com

43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM

WARNING!

CAUTION!

Over Temperature Alarm & Shut Off Device

All diagrams for illustrative purposes only.

Page 3: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

2

All diagrams for illustrativepurposes only.

GENERAL INFORMATION

The Over Temperature Alarm and Shut Off Device will be referred to as the "Device" in this Installa-tion and Operation Manual. The Device is recommended for use with any MrSteam CT Day Spa or CUCommercial Steam Generator System to provide over temperature shut off and alarm function. TheDevice is required where indicated by code.

IMPORTANT: Read these instructions and the CT Day Spa Installation and Operation Manual or theCU Steambath Generator Installation and Operation Manual thoroughly before installing or servic-ing the Device. If these materials are not available go to the "Downloads" section of the MrSteamwebsite or contact MrSteam for free replacements.

IMPORTANT INFORMATION ABOUT MRSTEAM CU COMMERCIALSTEAM GENERATORS AND CT DAY SPA STEAM GENERATORS.• Each CU Steambath Generator requires one D1 control. For typical installation see the CUInstallation, Operation & Maintenance Manual or the diagram on page 5. Set the D1 Control at amaximum of 118˚ F to prevent nuisance tripping of the Device.• For CT Day Spa Steambath Generator’s typical installation, see the CT Installation, Operation &Maintenance Manual or diagram on page 7.• Each room requires one Device when required by code.

DEVICE KIT CONTENTS:

• Device• Clear Tamper Proof Cover• Sensor• Sensor Guard• 30 ft. Cable• #6 x 1” Tapping Screw• #6 x 1” Anchors• Silicone• Instruction Manual

30 ft. Cable

SensorClear Tamper Proof Cover

Sensor Guard

Silicone

Device

#6 x 1" Screws

#6 x 1" AnchorsIMPORTANT! This Temperature Hi-limit Safety Device is for commercial steam rooms.

Do not install or operate this control without reading the instructions provided.For a replacement copy of instructions call 800-767-8326.

Page 4: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

120° F (49˚ C), the Device activates an internal 90dbalarm, and shuts down the steam generator.The display will flash STOP.• The Device can be reset after the steam room tem-perature falls below 120 °F (49 °C) by pressing theRESET button. This will shut off the alarm and dis-play the current room temperature.• The Device display remains ON if the steam bathgenerator switch is in the OFF position, however,power to the solenoids will be OFF.• The Device meets New York City Code Section165.63: Sauna and Steam Room requirements.TESTING THE SYSTEM• Press the down arrow button to shut off the system.This shuts off power to the steam generator, soundsthe alarm, and displays STOP. Push the RESET but-ton to reset.• Press and hold the up arrow button to displaythe set point temperature (120° F).• Test monthly to insure proper operation.

To prevent shock hazard, DO NOTinstall the Device in the steam room.

Use only for MrSteam CT Day Spaand CU Commercial Steam Systems. Do Not usefor spas, saunas or any other equipment. The useof the Device with any equipment other than aMrSteam CT Day Spa or CU Commercial SteamSystem may result in an inoperable device andcause overheating or scalding.

mr.steam® CU - H T C Installation & Operation Manual

3

CAUTION!

CAUTION!

All diagrams for illustrative purposes only.

DisplayMenu ButtonSet Point Temperature

Test Button

Reset Button

Mounting Screws

4-1/2"

4-1/2"

11/32"1/16"

3-3/8"

IMPORTANT! This Temperature Hi-limit Safety Device is for commercial steam rooms.Do not install or operate this control without reading the instructions provided.

For a replacement copy of instructions call 800-767-8326.

DIMENSIONS

DEVICE OPERATION

• The Device is to be used in conjunction with asteam generator being used to heat a steam room.• The Device is factory set at 120° F (49° C) set point,however always check local codes for the maximumallowable operating temperature. If the tempera-ture rises above the set point, the Device will soundand disconnect the heating source.• The Device and the steam generator can only bereset by the attendant after the steam room coolsto a point below the Device’s set point.• The cause of overheating must be determined andcorrected before resetting the Device or operatingthe steam room.• Use only for MrSteam CT Day Spa and CUCommercial Steam Systems. Do Not use for spas,saunas or any other equipment.• Device is powered by 120 VAC.

The cause of overheating must be de-termined and corrected before resetting the de-vice or operating the steam room. Never operatethe steam room at temperatures above 120˚ F orabove temperatures required by local codes. Op-erating the steam room at excessive temperaturemay result in overheating and scalding.

For additional safety considerations see the CU/ CTInstallation, Operation and Maintenance Manuals andthe safety signage that are supplied with the steamgenerator. If these materials are not available go tothe "Downloads" section of the MrSteam website orcontact MrSteam for free replacements.• Device shut-off is fixed at 120° F (49° C). When theDevice sensor detects temperature in excess of

WARNING!

Page 5: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

4

• Locate the Device outside of the steam room,in a location that’s visible and accessible to thesteam room attendant.

• Select a gang box and a gang box cover thatare appropriate for installation. Install gangbox at chosen Device location.

• Install the Device Sensor in the steam room,see Device Sensor Installation on page 9.

• Run the 30 ft cable from the Device Sensor’slocation to Device’s location. If the 30 ft cableis not long enough, run 20 AWG type CL2insulated solid copper wire in the appropriatedlength (100 ft max).

• Connect purple and yellow wire from pin 3 andpin 4 of Device to the terminal block in theGenerator, with 16 AWG stranded insulatedwire, see WIRING DIAGRAM on page 5.

CU STEAMBATH SYSTEM: DEVICE INSTALLATION

Device

DoubleGang Box

Gang BoxCover

Figure 1

To prevent shock hazard, DONOT install the Device in the steam room.

CAUTION!

Terminal Block

CU Generator

Steam RoomSensor Guard#6 x 1" Screws& Anchors

Device Sensor

Area Accessableby Owneror Attendant

30 ft. Cable

Purple Wire

Yellow Wire

30 ft. Cable for Device Sensor

Black and White Wiresto 120 VAC Power SupplyConnector for 30 ft. Cable

Mating Connectoron 30 ft. Cable

Facility or Mechanical Room

Device

Field Wiring that connect purpleand yellow wires on Device toTerminal Block on CU Generator

Figure 2

• Connect black and white wire from pin 10 and pin 11of Device to 120 VAC input terminals in generator(see wiring diagram on page 5), with 16 AWGstranded insulated wire.

• Connect 30 ft cable on Device Sensor to its matchingconnector on supplied 30 ft. cable,see Figure 2.

• Connect Device Sensor to the other end of supplied30 ft cable.

• Fasten Device onto gang box cover with4 mounting screws, see Figure 1.

All diagrams for illustrative purposes only.

Page 6: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

5All diagrams for illustrative purposes only.

Factory WiringField Wiring

Device

PROBE

Reset

YEL

PUR

BLK

WHT

RED

CU Alarm(optional)

SteamRoom

InternalBuzzer

Remove Jumperwhen Device

is installed

Remove Jumperwhen 2ndDevice isinstalled

Terminal Block inside CU Steam Generator

Remove Jumperwhen 2nd Digital 1

is Installed

2ndDigital 1

120 VAC Input

1 2 3 4 5 6 7 8 9 10 11

NL

CU WIRING DIAGRAM

Device

U T I L I T Y R O O M

Location visibleand accessibleto the steam

room attendant. S T E A M R O O M

3⁄4" SteamSolenoid

3⁄4" Steamhead withAcrylic Shield orLinear Steamhead

SteamGenerator Fully

InsulatedSteamPipe

DeviceSensor

D1 ControlSensor

1" SteamOutlet

e

NOTE: FOR ILLUSTRATIVE PURPOSES ONLY. Optional equipment shown. Consult with qualifieddesigner, architect or contractor for steam room construction details, including location of steam-head(s) and sensors.

To prevent shock hazard, DO NOT install the Device in the steam room.

TYPICAL INSTALLATION OF CU GENERATOR, STEAMHEAD AND DEVICE

CAUTION!

Page 7: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

6

TerminalBlock

CT Generator

Facility or Mechanical Room

Field Wiring that connect purple and yellow wireson Device to Terminal Block on CT Generator

30 ft.Cable

Purple Wire

Yellow Wire

30 ft. Cable for Device Sensor

Steam RoomSensor Guard

#6 x 1" Screws& AnchorsDevice Sensor

Black and White Wires to120 VAC Power Supply

Connector for30 ft. Cable

Mating Connectoron 30 ft. Cable

Device

Area Accessable byOwner orAttendant

All diagrams for illustrative purposes only.

• Locate the Device outside of the steam room,in a location that’s visible and accessible to thesteam room attendant.

• Select a gang box and a gang box cover thatare appropriate for installation. Install gang boxat chosen Device location.

• Install the Device Sensor in the steam room,see Device Sensor Installation on page 9.

• Run the 30 ft cable from the Device Sensor’slocation to Device’s location. If the 30 ft cable isnot long enough, run 20 AWG type CL2insulated solid copper wire in the appropriatedlength (100 ft max).

• Connect purple and yellow wire from pin 3 andpin 4 of Device to the terminal block in theGenerator, with 16 AWG stranded insulatedwire, see CT WIRING DIAGRAM on page 7.

CT DAY SPA SYSTEM: DEVICE INSTALLATION

Device

DoubleGang Box

Gang BoxCover

Figure 1

To prevent shock hazard, DONOT install the Device in the steam room.

CAUTION!

• Connect black and white wire from pin 10 and pin 11of Device to 120 VAC power supply, with 16 AWGstranded insulated wire.

• Connect 30 ft cable on Device Sensor to its matchingconnector on supplied 30 ft. cable, see Figure 2.

• Connect Device Sensor to the other end of supplied30 ft cable.

• Fasten Device onto gang box cover with 4 mountingscrews, see Figure 1.

Figure 2

Page 8: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

7

DEVICE SteamRoom

YEL

PUR

BLK

WHT

WHT

RED

L N120 VAC Input

Reset

PROBE

CU Alarm(optional)

InternalBuzzer

1 2 3 4 5 6 7 8 9 10 11

C

GROUND

G

AutoFlush(optional)

Steam Genie(optional)

Control

Wiring inside a CT Steam Generator

RED

WHT/RED

BLUE

WHT/BLUE

BLACK

BLACK

PURPLEMSTS

Temp. Probe

GREEN

Remove Jumper

To ProbeControl Board

Transformer

S

Water FeedSolenoid

Valve

Thermostat

Contactor

GRAY

WHT/GRAY

Factory WiringField Wiring

CT WIRING DIAGRAM

All diagrams for illustrative purposes only.

NOTE: FOR ILLUSTRATIVE PURPOSES ONLY. Some components may be omitted or altered for clar-ity. Do not use for wiring, repair or other purposes not related to component identification.

To prevent shock hazard, DO NOT install the Device in the steam room.

TYPICAL INSTALLATION OF CT GENERATOR, STEAMHEAD AND DEVICE

CAUTION!

SteamGenerator

Device SensorRemote Sensor

CT SteamStopControl

Control

Device

Steamhead

U T I L I T Y R O O M

Location visibleand accessibleto the steam

room attendant.

S T E A M R O O M

Page 9: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

8All diagrams for illustrative purposes only.

CLEAR TEMPER PROOF COVER INSTALLATION• Remove cover for easy installation, by pulling the Hinge Tabs, see fig 1.

• Place Base Ring over the Device, align Base Ring with the Device and use a level to level Base Ring.Mark locations of 4 mountings holes for Base Ring, see fig 2.

• Drill 4 pilot holes for anchors (included).

• Mount Base Ring to wall with 4 anchors (included) and 4 x 1-1/4" long screws (included), see fig 3.

• Snap Cover back onto Base Ring and lock with key (included), see fig 4.

Hinge Tabs

Cover Base Ring

Fig. 1

Base Ring

Device

MountingHoles

Fig. 2

Fig. 3

Fig. 4

Key

Cover

Base Ring

Anchors(included) Wall

1-1/4"Long Screws

(included)

Base Ring

Device

IMPORTANT! This Temperature Hi-limit Safety Device is for commercial steam rooms.Do not install or operate this control without reading the instructions provided.

For a replacement copy of instructions call 800-767-8326.

Page 10: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

9

Ensure that 1/2" of the Sensor tip is in"free air" and clear of silicone or any material.Failure to keep the Sensor tip free of silicone sealantmay interfere with steam room temperature monitoringand may cause overheating or scalding.

DEVICE SENSOR INSTALLATIONInstall the sensor:• On a vertical surface.• 4-5 feet above the floor in a location representative of the desired steam bathing temperatures.• Do not locate the Sensor above or near the steam head or direct steam emissions.

DO NOT LOCATE THE DEVICE SENSORS NEAR OR ABOVE THE STEAMHEAD(S)WHERE DIRECT STEAM EMISSION CAN INTERFERE WITH STEAM ROOM TEMPERATUREMONITORING. IMPROPER LOCATION OF THE SENSOR MAY INTERFERE WITH TEMPERATUREMONITORING AND MAY CAUSE OVERHEATING OR SCALDING.

• Route Sensor cable directly to Device.

• Do not route Sensor Cable with power wiring, next to electric motors or any other location subject toelectrical noise. Subjecting the wiring to electrical noise may cause improper Device operation.

• Ensure that the Sensor protrudes a minimum of 1/2" from the wall surface.

• Seal 3/8" hole with silicone provided.

• Protect Sensor with Sensor Guard provided.

Ensure all splices in the Sensor Cable are securely crimped or soldered and sealed withheat shrink tubing as required for a secure electrical connection.

Sensor Cable

3/8" hole

Silicone Sealant

(4) Mounting Screws(supplied)Sensor Guard

Route Sensor Cable directly tothe supplied 30 ft Cable

Locate approximately 4-5 feetabove steam room floor

Sensor

CAUTION!

CAUTION!

Cross-section viewof sensor for reference

- Apply silicone sealant only as required for a moisture proofseal. Do not apply silicone to the exposed 1/2" of the sensor.

CAUTION!

All diagrams for illustrative purposes only.

Page 11: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam® CU - H T C Installation & Operation Manual

10

WARRANTY: To view or download the MrSteam Residential Device Warrantyand register your product go to: blog.mrsteam.com/wr

Message TableMessage Description

Opened Device Sensor connection. Shut off power to Device and check Device Sensor connection.

Shorted Device Sensor connection. Shut off power to Device and check Device Sensor connection.

Device in Stop mode. See "Device Operation" on page 3.

Device reset to factory defaults by pressing and holding MENU button and UP arrow button for5 seconds or longer. Shut off power to Device to complete factory reset. This will remove calibratedoffset value of Device Sensor.

Monthly Check List

Did Set Point Temperaturedisplay when pressing and

holding the Up Arrow button?Date

of TestName of tester& signature

Did the Device shut off power tothe steam generator, sound thealarm, and display STOP when

the Down Arrow Button is pressed?

Did the Device reset thesystem when the Reset

button is pressed?

CALIBRATION OF DEVICE SENSORCalibration is necessary after Device and Device Sensor installa-tion to ensure an accurate steam room temperature reading. Atthis point, Device and Device Sensor should be installed, tested,and functioning properly.

• Press and hold Menu Button for 3 seconds to enter |configuration mode.

• Device will show a blank display with only the left most digitflashing “0”. Use the Up and Down Arrow buttons to enterpass code “5913” one digit at a time. Press the Menu Button after entering each digit.

• After entering the four-digit pass code, press Menu Button to enter input parameter “InPt”.Press Menu Button again to enter parameter “I.CAl” for calibration of Device Sensor.

• Press Menu Button to confirm entering calibration of Device Sensor, then use theUp and Down Arrow button to enter offset value for Device Sensor of a maximum of +25° Fand a minimum of -25° F. Press Menu Button to confirm offset value.

• Press and hold Menu Button to exit input parameter. Press and hold Menu Button again to exitconfiguration mode.

• Device should now display Device Sensor reading with offset value.

Display

Menu Button

Up Arrow

Down Arrow

IMPORTANT! This Temperature Hi-limit Safety Device is for commercial steam rooms.Do not install or operate this control without reading the instructions provided.

For a replacement copy of instructions call 800-767-8326.

All diagrams for illustrative purposes only.

Page 12: OverTemperatureAlarm andShutOffDeviceprodrep.mrsteam.com/DocumentResources/0afbf502-24e...120°F(49˚C),theDeviceactivatesaninternal90db alarm,andshutsdownthesteamgenerator. ThedisplaywillflashSTOP

mr.steam®

Feel Good Inc.®

mr.steam Sussman-Automatic Corporation® I [email protected] I www.mrsteam.com43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM

2018 © Sussman-Automatic Corporation I MrSteam and des., A Lifetime of Pleasure, AirTempo, AromaFlo, AudioWizard, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...Every Time,Club Therapy, CT Day Spa, Digital 1, Express Steam, Feel Good Inc., From Bathroom to Spa, HomeWizard, iButler, iGenie, iSpa Package, iSteam, iTempo, iTempo/Plus, Linear Steamhead, Making Wellnessa Way of Life, Music Therapy, My Steam, SmartSizing, Spa Package, Steam Genie, Steam on Demand, Steam in a Box, Steam@Home, SteamStart, SteamTherapy, Sussman, Tala, Tala Bath & Body, Tempo,The Intelligent Steambath, Valet Package, and Virtual Spa System are registered trademarks of Sussman-Automatic Corporation. PUR 100562 REV 6.19

FOR MORE INFORMATION PLEASE CALL

Sales & SupportEAST COAST 1.800.76.STEAM

WEST COAST 1.800.72.STEAM

www.mrsteam.com

Products, information andspecifications are subjectto change without notice.