overall conclusion pendingartis.ai.accu-group.com/files/pdf/011606-is0046-flpi/... · 2016. 6....

18
Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 1 of 18 This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from their contractual obl igations nor prejudice buyer’s right for compensation for any apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment. ©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent GENERAL INFORMATION: Client Name : For life products Supplier : Foshan Shunde Maxcan Electrical Appliance Co.LTD Factory : Foshan Shunde Maxcan Electrical Appliance Co.LTD Inspection Date : 2016/6/23 Location : Shunde,Guangdong,South China Inspector(s) Code : 043 Authorizer : Elvis Zhao Inspection Type : During Production Inspection Product Description : Humidifier Purchase Order No. : 882(QVC) Item/SKU/Style No. : MH-901D black P.O. Quantity : 9690 Pieces Shipment Quantity : 9690 Pieces INSPECTION RESULT SUMMARY: 1) Quantity check : Pending, Refer to remark: 1 2) Workmanship : Pass 3) Product Description, Style, & Color Conformity : Pass 4) Labeling, Printing, Marking & Barcode : Pass 5) Packaging & assortment : Pass 6) Shipping marks : Pass 7) On-site test and Data measurement : Pass OVERALL CONCLUSION Pending Refer to Remark:1 Important Remarks: 1) For quantity check: During this inspection, there were two production lines (line 1 & 2) in production item MH-901D Black, it was finished 2399pcs for item MH-901D black(total: 9690pcs, finished:24.8%) at today. Reminding: 1) This is production completion condition for PO 882(item:MH-901D(QVC), details as below Order No. Item/SKU/ Style No. Order Qty Shipment Qty Packed in carton Finished not packed (Units) (Units) (Carton) Qty % Qty % 882(QVC) MH-901D Black 9690 9690 9690 8864 91.5 0 0 MH-901D Cream 4262 4262 4262 4262 100 0 0 MH-901D Navy 1938 1938 1938 1938 100 0 0

Upload: others

Post on 07-Nov-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 1 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

GENERAL INFORMATION:

Client Name : For life products

Supplier : Foshan Shunde Maxcan Electrical

Appliance Co.LTD Factory :

Foshan Shunde Maxcan Electrical

Appliance Co.LTD

Inspection Date : 2016/6/23 Location : Shunde,Guangdong,South China

Inspector(s) Code : 043

Authorizer : Elvis Zhao

Inspection Type : During Production Inspection

Product Description : Humidifier

Purchase Order No. : 882(QVC)

Item/SKU/Style No. : MH-901D black

P.O. Quantity : 9690 Pieces

Shipment Quantity : 9690 Pieces

INSPECTION RESULT SUMMARY:

1) Quantity check : Pending, Refer to remark: 1

2) Workmanship : Pass

3) Product Description, Style, & Color

Conformity

: Pass

4) Labeling, Printing, Marking &

Barcode

: Pass

5) Packaging & assortment : Pass

6) Shipping marks : Pass

7) On-site test and Data measurement : Pass

OVERALL CONCLUSION Pending

Refer to Remark:1

Important Remarks:

1) For quantity check:

During this inspection, there were two production lines (line 1 & 2) in production item MH-901D Black, it was finished 2399pcs

for item MH-901D black(total: 9690pcs, finished:24.8%) at today.

Reminding:

1) This is production completion condition for PO 882(item:MH-901D(QVC), details as below

Order No. Item/SKU/

Style No.

Order Qty Shipment Qty Packed in carton Finished not packed

(Units) (Units) (Carton) Qty % Qty %

882(QVC)

MH-901D Black 9690 9690 9690 8864 91.5 0 0

MH-901D Cream 4262 4262 4262 4262 100 0 0

MH-901D Navy 1938 1938 1938 1938 100 0 0

Page 2: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 2 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

MH-901D Taupe 3875 3875 3875 3875 100 0 0

MH-901D Wine 3875 3875 3875 3875 100 0 0

MH-901D Orchid 2325 2325 2325 2325 100 0 0

MH-901D Sky Blue 2325 2325 2325 2325 100 0 0

MH-901D Platinum 10460 10460 10460 10460 100 0 0

Total: 38750 38750 38750 37924 97.9 0 0

Special Check Points

Description Result Actual findings

A. -

1) QUANTITY CHECK : Pending, Refer to remark: 1

Order No. Item/SKU/

Style No.

Order

Qty Shipment Qty Packed in carton

Finished not

packed

Sample Size

Packed Unpacked

(Units) (Units) (Carton) Qty % Qty % (Units) (Carton) (Units)

882(QVC) MH-901D 9690 9690 9690 2399 24.8 0 0 50 50 0

Total: 9690 9690 9690 2399 24.8 0 0 50 50 0

2) WORKMANSHIP : Pass

Inspection Standard: ISO 2859 AQL Accepted Rejected Total

Found

Sample

size

Sampling Plan : Single normal Critical : Not allowed 0 1 0 50

Sampling Level : Fixed Sample

Size

Major : 1.5 2 3 0 50

Sample Size : 50 Pieces Minor : 4.0 5 6 1 50

No. Defects Description: CRI MAJ MIN

Item No.: MH-901D Sample Size: 50 Samples

1. Scratches on the water tank - - 1

Total Found: - - 1

Representative Defects Photos:

N/A N/A

defect-minor-scratches on the water

tank N/A N/A

Note: Please refer to “Photo Attachment” For All defects photos .

Page 3: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 3 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

3) PRODUCT DESCRIPTION/STYLE/COLOR : Pass

Check points Result

1. Check against PO Pass

2. Check against product Spec/Drawing Pass

3. Check against Photo(s) Pass

4. Check against Instruction Manual Pass

5. Check against certificate: FCC ETL Pass

6. Check against component check Pass

Table-3.1: Critical component compare to certificate:

Component description Actual marking on component Does the Marking comply

with certificate?

Item No.: MH-901D

- Plug TIANJU TJ-1 E232726 UL Yes

- Power cord E232874 SPT-2 2x18AWG(0.824mm2) VW-1 105

oC 300V

TIANJU

Yes

- Ultrasonic transducer JYD Yes

- Transformer HYT0070A EER-28 Yes

- Thermal link AUPO BF94 Tf94oC Yes

- Fan motor NJ5015SM DC12V 0.06A Yes

- PCB 94V-0 S-1D E240257 UL Yes

- X capacitor 0.22uF MPX 40/105/21 275V~ BM Yes

- Y capacitor HEC CT7 222M UL Yes

- Fuse 5F 2.5A 250V Yes

- Water drain valve FPDF-16Y 12VDC 0.4A TIAN SHAN Yes

Table-3.2: Product dimension / weight measurement:

Item Sample size Specification Actual

MH-901D 1 10.4x7.8x34.1 inches/4.33lbs 10.28x7.76x34.08 inches/4.75lbs

Table-3.3: Power cord length:

Item Sample size Specification Actual

MH-901D 2 / 153/153 cm

Table-3.4: Water tank capacity:

Item Sample size Specification Actual

MH-901D 2 6.1L 6.13/6.15kg

Page 4: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 4 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

Photos of Product:

4) Labeling, Printing, Marking & Barcode : Pass

Check points Result

1. Barcode verification Pass

2. Warning words / Label Pass

3. Logo / Brand Pass

4. Certificate mark / Other Symbol Pass

5. Artwork (Label/User manual/Warranty card/hang tag) Pass

Table-4.1: Barcode verification:

Item Sample size Specification Actual

MH-901D 2 Outer carton V34160 012000 V34160 012000 for both

Gift box 180104004101 0180104004101 for both

Photos of Logo, Labeling, Printing, Marking & Barcode:

5) PACKAGING AND ASSORTMENT : Pass

Check points Result

1. Packaging checking Pass

2. Carton quantity and assortment checking Pass

3. Packing dimension and weight measurement Pass

Table-5.1: Packaging checking

Item Individual packing Unit package Inner carton Outer carton

MH-901D

Each sets product with a language the instruction manual; a

plug; plug use warning card; warning card and satisfaction

card were packed into a gift box, and protected by

Foam & poly

bag

Gift box,

single wall

Single wall,

sealed with

transparent

Page 5: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 5 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

foam ,and gift box packing into carton gummed tape

Table-5.2: Carton quantity and assortment checking

Item Sample size Quantity / inner carton Quantity / outer cartoon

MH-901D 1 1 1

Table-5.3: Dimension / weight of individual package:

Item Sample size Specification Actual

MH-901D 1 / 31x26.5x46.6cm/2.56kg

Table-5.4: Dimension / weight of master carton:

Item Sample size Specification Actual

MH-901D 1 / 32x27.8x48cm/3.02kg

Photos of Packaging:

6) SHIPPING MARK : Pass

Check points Result

1. Product description on shipping mark

(Name/Item/Reference No. etc)

Pass

2. Batch Number on shipping mark

(PO No./Date code etc)

Pass

3. Shipping mark layout Pass

Photos of Shipping mark:

Main mark ( 1 Sides) Side mark ( 0 Sides) Other mark ( 0 Sides)

N/A N/A

Page 6: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 6 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

7) ON-SITE TEST & DATA MEASUREMENT : Pass

Check points Sample Size Result

1. Hi-Voltage check(1500 V 1 second) All Samples Pass

2. Power consumption / Input current check All Samples Pass

3. Function check All Samples Pass

4. Internal Check for Workmanship 2 Samples Pass

5. Power on 4 hours check 2 Samples Pass

6. Real function operating check 2 Samples Pass

7. Strain relief check on power cord 2 Samples Pass

8. Barcode Readability Check 2 Samples Pass

9. Stability check at 10 degree 2 Samples Pass

10. Assembly check 2 Samples Pass

11. Rub Check for printing/painting 2 Samples Pass

12. Tape Check for printing/painting 2 Samples Pass

13. Transportation drop check 2 Samples Pass

14. Overheat protection check (thermal fuse) 2 Samples Pass

15. PCB coating check 2 Samples Pass

16. Time accuracy check 2 Samples Pass

17. Max pumping water time check 2 Samples Pass

18. Auto turn off time check (after lack of water ) 2 Samples Pass

Table-7.1: Power consumption measurement: (W)

Item Sample size Setting / Specification Actual

MH-901D all Setting 120V~

60Hz

At Max with turbo 24.7.2-27.2 W

At Max 22.1-23.2 W

At Min 11.9-12.7 W

Table-7.2: Steam rate check :

Item Sample size Setting / Specification Actual

MH-901D(Navy) 2 Setting 120V~

60Hz 4hrs

Low 71/73 g

High 312/299 g

Page 7: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 7 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

Table-7.3: Time accuracy check:

Item Sample size Setting / Specification Actual

MH-901D 2 60min 59’54”59/60’00”10

Photos of On-site test:

PROCESS OBSERVATIONS

Subject: Observations:

- Materials OK

- Work in process OK

- Finishing Pending(see remark1)

- Packing/Assortment OK

- Recommendations: - Keep the production lines clean and tidy.

- Lubricate and maintain the production machines well to ensure it in a good condition.

Page 8: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 8 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

- Array and stock semi-finished products in good order to avoid confused or damaged.

- Identify the defective products with marking or labeling to avoid it mixed with the

conforming product.

- To ensure the reworked and repaired products being re-inspected before release.

- Promote the ability / skill / awareness of workers.

- Make more training / explaining on main points of requirements to operators for

process:

NOTE

1) No carton No. was available in this inspection.

2) Manufacturer refused us to draw one production sample to ACCU office for reference.

ATTACHMENTS (List all documents attached to this report)

1) NIL

PHOTO ATTACHMENT

01 production line

01 production line 1 02 production line 2 03 production line view 1

04 production line view 2 05 production line view 3 06 production line view 4

N/A N/A

07 production line view 5 N/A N/A

02 product view

Page 9: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 9 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

08 outer carton view 1 09 outer carton view 2 10 outer carton view 3

11 gift box view 1 12 gift box view 2 13 gift box view 3

14 gift box view 4 15 gift box view 5 16 gift box view 6

17 gift box view 7 18 gift box view 8 19 gift box view 9

Page 10: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 10 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

20 gift box view 10 21 gift box view 11 22 gift box view 12

23 gift box view 13 24 product packing view 1 25 product packing view 2

26 product packing view 3 27 product packing view 4 28 product packing view 5

29 product packing view 6 30 product packing view 7 31 product packing view 8

Page 11: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 11 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

32 product packing view 9 33 product packing view 10 34 product packing view 11

35 product packing view 12 36 product packing view 13 37 product packing view 14

38 product packing view 15 39 warning card 40 satisfaction card

41 product IM view 1 42 product IM view 2 43 product IM view 3

Page 12: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 12 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

44 product IM view 4 45 product IM view 5 46 product IM view 6

47 product IM view 7 48 plug use card 49 product view 1

50 product view 2 51 product view 3 52 product view 4

53 product view 5 54 product view 6 55 product view 7

Page 13: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 13 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

56 product view 8 57 product view 9 58 product view 10

59 product view 11 60 product marking view 1 61 product marking view 2

62 product marking view 3 63 product marking view 4 64 product marking view 5

65 product marking view 6 66 warning label 67 rating label

Page 14: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 14 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

N/A N/A

68 patent label N/A N/A

03 on site test

69 outer carton size check 70 gift box size check 71 product size check

72 outer carton GW check 73 gift box GW check 74 product weight check

75 water tank capacity check 76 barcode scanning check 1 77 barcode scanning check 2

Page 15: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 15 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

78 silk screen check 1 79 silk screen check 2 80 power cord length check

81 power cord pull check 82 Stability check 83 steam rate check

84 function check 1 85 function check 2 86 function check 3

87 function check 4 88 function check 5 89 function check 6

Page 16: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 16 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

90 function check 7 91 function check 8 92 function check 9

93 function check 10 94 Hi-Voltage check 95 internal check 1

96 internal check 2 97 main component check 1 98 main component check 2

99 main component check 3 100 main component check 4 101 main component check 5

Page 17: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 17 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

102 main component check 6 103 main component check 7 104 main component check 8

105 main component check 9 106 main component check 10 107 main component check 11

108 main component check 12 109 main component check 13 110 main component check 14

111 main component check 15 112 main component check 16 113 main component check 17

Page 18: OVERALL CONCLUSION Pendingartis.ai.accu-group.com/Files/PDF/011606-IS0046-FLPI/... · 2016. 6. 23. · N/A N/A Note: Please refer to “Photo Attachment” For All defects photos

Inspection Report (DPI) Report No.: 011606-IS0046-FLPI Page: 18 of 18

This report reflects our findings at the time and place in inspection. This inspection has been carried out to the best of our knowledge and ability and our responsibility is limited to the exercise of reasonable one. This report does not relieve the sellers from thei r contractual obl igations nor prejudice buyer’s right for compensation for any

apparent and/or hidden defects not detected during our random inspection or occurring thereafter. This report does not evidence shipment.

“©2003-2015 AccuInspection All rights reserved. Do not disclose outside your organization w ithout AccuInspection prior w ritten consent”

N/A

114 PCB coating check 1 115 PCB coating check 2 N/A

04 defect

N/A N/A

116 defect-minor-scratches on

the water tank N/A N/A

------END OF THE REPORT------