our new line of ptac's-ac's and heat pumps

23
Packaged Terminal Air Conditioners New Design 2012-PTAC

Upload: dgeisert

Post on 18-Jul-2015

179 views

Category:

Business


1 download

TRANSCRIPT

Page 1: Our New Line of PTAC's-AC's and Heat Pumps

Packaged Terminal Air Conditioners( New Design)

2012-PTAC

Page 2: Our New Line of PTAC's-AC's and Heat Pumps

Generation Two - PTACGeneration Two - PTAC1

Product Lineup and Features Product Lineup and Features 2

New Panel and AssemblyNew Panel and Assembly3

CONTENTS

Page 3: Our New Line of PTAC's-AC's and Heat Pumps

Generation Two - PTACGeneration Two - PTAC1

In collaboration with our customers we are pleased to introduce our new PTAC lineup. Improvements include:

A more user and installer friendly high performance product range. A refined and more elegant appearance. Ease of assembly and maintenance through the use of innovative sub-assemblies.

Page 4: Our New Line of PTAC's-AC's and Heat Pumps

1. Unit Types: Cool only Cool only with electric heater Heat pump with electric heater

2. Available Capacit ies: 7K Btu, 9K Btu ,12K Btu, 15K Btu

3. Power Arrangements: 208~230V/1Ph/60Hz 265V/1Ph/60Hz

Product Lineup and FeaturesProduct Lineup and Features

22

2

Page 5: Our New Line of PTAC's-AC's and Heat Pumps

Product Lineup and FeaturesProduct Lineup and Features2

FEATURESFEATURES::

15 Second Fan Off Delay

Random Compressor Restart

Comfort Control Design

Room Freeze Protection

Self Diagnostics

Effortless™ Maintenance

24 Hour On/Off Timer

Highly Energy - Efficient

Multi-Speed Fan

Silent Design

Memory

Automatic Auxiliary Heat

Eco-Friendly with R410a Refrigerant

Versatile Multi-Mode Operation

Page 6: Our New Line of PTAC's-AC's and Heat Pumps

Features and Benefits3

Highly Energy Efficient

The units are matched with a variety of leading brand compressors coupled with the use of more energy efficient motors and fans. Our R&D team has chosen the most energy efficient combinations.

Quiet Operation:

Our new unit is much quieter in operation because of the high quality cross flow fan design, hermetically sealed plastic motor, and improved air flow design. Additionally the compressor noise has been isolated from the indoor section by use of an acoustically reinforced center panel.

Page 7: Our New Line of PTAC's-AC's and Heat Pumps

Features and Benefits3

Random Compressor Restart

To help prevent power surges after a power outage or from many of our PTACs starting at the same time, the compressor is equipped with a 120 to 240 second random restart delay feature. Whenever the unit is plugged in or power has been restored, a random compressor restart will occur.

Auto Restart Memory

Our new units have a power off memory function. If power is ever lost or the unit is off control settings are memorized (set point, mode, fan speed). When power is restored or the unit is turned on the previous settings will operate.

Page 8: Our New Line of PTAC's-AC's and Heat Pumps

New Panel and Assembly New Panel and Assembly 2

Shear elegance.

Page 9: Our New Line of PTAC's-AC's and Heat Pumps

Front panel Electronic control box Base pan

Wall sleeve

Grille

Indoor side

Outdoor side

New Panel and AssemblyNew Panel and Assembly3

Compact structure based on maintenance friendly sub assemblies design

Page 10: Our New Line of PTAC's-AC's and Heat Pumps

New Panel and Assembly New Panel and Assembly 2

The elegance is matched with improved inlet and exhaust air performance.

CoolingHeating

Air Filter

Page 11: Our New Line of PTAC's-AC's and Heat Pumps

The leaf and horizontal plane form a 76°angle.

Rotating 180°from right to left the leaf and

horizontal plane form a 46°angle

◆ A unique air flow design with two angles to ensure maximum comfort

New Panel and AssemblyNew Panel and Assembly 3

When Cooling, air is discharged at 76°as cool air falls.

When Heating, air is discharged at 46°as warm air rises.

Page 12: Our New Line of PTAC's-AC's and Heat Pumps

◆ Indoor air flow sub assembly can be removed as shown, which is ideal for maintenance and cleaning.

New Panel and AssemblyNew Panel and Assembly 3

Page 13: Our New Line of PTAC's-AC's and Heat Pumps

◆ Use of a larger cross flow fan: Φ120 ×700mm

◆ Plastic sealed motor ensures a quieter and more reliable operation

◆ Well mounted and strong assembly

New Panel and AssemblyNew Panel and Assembly 3

Fan Balancing

Page 14: Our New Line of PTAC's-AC's and Heat Pumps

The electronic control box is sealed for fire

safety.

The electronic control box can be opened and is conveniently

located for installation and maintenance.

◆ Sealed electronic control box with easy access.

New Panel and AssemblyNew Panel and Assembly 3

Page 15: Our New Line of PTAC's-AC's and Heat Pumps

Intelligent electronic control board

New Panel and AssemblyNew Panel and Assembly 3

Optional universal electric heater

Page 16: Our New Line of PTAC's-AC's and Heat Pumps

When closed only the air inside the room is circulated and filtered. When opened

outdoor air will be filtered and drawn into the room.

Control lever

New Panel and Assembly New Panel and Assembly 2

Fresh air intake with a manual control lever conveniently located on the side of the unit.

Page 17: Our New Line of PTAC's-AC's and Heat Pumps

◆ Outdoor sub assembly structure can easily be removed independently for convenient disassembly and cleaning.

New Panel and AssemblyNew Panel and Assembly 3

Page 18: Our New Line of PTAC's-AC's and Heat Pumps

◆ The condenser axial fan has three blades which provide for greater air flow.

◆ Additionally we have added a water slinger feature to enhance the condensate management system.

New Panel and AssemblyNew Panel and Assembly 3

Greater Air Flow

Water Slinger Fan

Page 19: Our New Line of PTAC's-AC's and Heat Pumps

◆ Drainage tray and Base pan designed for enhanced drainage.

Base pan

Combination

Drainage Tray

New Panel and AssemblyNew Panel and Assembly 3

Page 20: Our New Line of PTAC's-AC's and Heat Pumps

New Panel and Assembly New Panel and Assembly 2

Improved drainage device with easy access. Heat pump models only.

Page 21: Our New Line of PTAC's-AC's and Heat Pumps

◆ Standard wall sleeve

42 ″

16 ″

14 ″

New Panel and AssemblyNew Panel and Assembly 3

Knocked down for convenient transportation

Standard size 42″×16″×14″.

Page 22: Our New Line of PTAC's-AC's and Heat Pumps

◆Four Control Options

Remote Control

Panel Control

Wireless Control

New Panel and AssemblyNew Panel and Assembly 3

Wired Control

Page 23: Our New Line of PTAC's-AC's and Heat Pumps

Thank you!