Orion On-Line Water Analysis
p r o d u c t s c a t a l o g
pH / ISE / DISSOLVED OXYGEN / CONDUCTIVITY
WASTEWATER / DRINKING WATER / POWER
SEMICONDUCTOR / PAPER PULP / PURE WATER
BOILER WATER / CHEMICAL / PETROCHEMICAL
Analyze • Detect • Measure • ControlTM
Dear Valued Customer,
Welcome to the NEW Orion On-Line Water Analysis Catalog. This edition includes our wide range of
continuous monitors designed to measure concentrations of various chemical species in a On-Line
environment. On-Line measurements are becoming increasingly important for a number of reasons.
Improved detection limits are now possible and regulations are mandating lower levels of contaminants in
water. On-Line monitors are ready to meet all your critical measurement needs.
New product highlights of this edition include:
• New 1811EL Diisopropylamine Reagent for better lower-level stability and longer reagent life.
• The 1817LL Low-Level Chloride Monitor for detecting ppb levels of chloride in
power plant chemistry.
• The QC Sampler introduces samples and standards for rapid validation of analyses.
Products include:
• 2001 pH Monitoring System featuring exclusive ROSS™ pH Technology
• 2002 pH and Conductivity Systems
• 2030 Silica Analyzer for pure water measurements
• 1700 Series Analyzers for chlorine and fluoride measurements in final release wastewater
• 1800 Series Analyzers, for specific ion and dissolved oxygen analysis in pure and potable water
• On-Line electrodes for process applications
• Steam Conditioner to reduce the temperature and pressure of a steam sample for On-Line analysis
• Paperless data recorders
Also available are Applications Support, Technical Notes and information about Orion laboratory products.
For comprehensive information about other Orion’s products please request the latest copy of the
Laboratory Products Catalog or Titration Products Catalog. Our Technical EdgeSM Customer Service Program
is available at 800.225.1480 or by fax at 978-232-6015. Please visit us at www.thermo.com, for the very
latest product information.
Thank you for your support and we will continue to guarantee your success!
Sincerely,
Jim Barbookles
President & CEO
Water Analysis
Environmental Instruments 166 Cummings Center Beverly, MA (978) 232-6000 www.thermo.com
Water Analysis
01915-6199 USA (978) 232-6015 fax
(800) 225-1480 technical
1
table of contentsanalyzer selection table
Monitors: Page(s):
Pure Water Analysis 2
Boiler Water Chemistry 3
Power Plant Chemistry 4
Drinking Water 5
Wastewater 6
Conductivity Analyzers & Sensors 7
ROSS™ pH 8, 9
pH Analyzers 10, 11
AquaPro - Industrial pH Electrodes 12, 13
Sodium 14, 15
Fluoride 16, 17
Chloride 18, 19
Ammonia 20
Dissolved Oxygen 21
Silica 22
Chlorine 23
Calcium 24
Oxygen Scavenger 25
Accessories: 26-27
• Paperless Recorders
• Steam Conditioner
• Dynamic Calibrator
• QC Sampler
Terms and Conditions, Warranty 28
Industries that manufacture and use DI/UPW are many.Some common ones are:
• The Power Industry, for steam generation to drive turbines.
• The Semiconductor Industry, for wafer production rinse water.
• The Pulp and Paper Industry, for steam generation usedto boil the wood pulp and also to drive turbinesgenerating power.
• The Pharmaceutical Industry, for products e.g. Water ForInjection (WFI), cleaning and rinsing, addition togranulates for tablet manufacturing and steamgeneration.
• The Petrochemical Industry, for steam generation usedto heat and boil products (better than naked flames!)and also for power generation.
The DI/UPW is generally manufactured using two methods, often a combination of both:
• Resin columns for stripping out cations (positivelycharged ions) and anions (negatively charged ions).
• Reverse Osmosis.
Resin columns are the most common and best way fordeionizing water. Good resins leave pure H2O. However, aresin column only has a limited life before the resins needto be regenerated. This regeneration process takes timeand is expensive. It involves washing resins with largequantities of sulfuric acid (for cation columns) or caustic(for anion columns). The more efficient the column is(until breakthrough occurs), the less expensive and moreenvironmentally safe it is for the user. Reverse Osmosisunits are often used ahead of demineralizers becausethey remove a good amount of the dissolved salts in theraw water. This extends the run time of the resin beds andlowers the frequency of regeneration.
Sodium
Water (usually city water or RO conditioned water) passesthrough a cation resin column first. This strips out cationssuch as sodium, potassium and calcium and exchangesthem for hydrogen ions. When the column is saturated,ions with the weakest bond to the resin escape. This iscalled "breakthrough" and when caught in time allows theuser to switch to a new resin column while regeneratingthe exhausted column. Sodium has the weakest bond ofall common cations and can be measured reliably at lowlevels. Sodium analyzer (Model 1811AO) is used to catchthis "breakthrough" as it is occurring.
Silica
The water leaving the cation column is now free of allcations, having replaced them with hydrogen ion, H+.Anions such as chloride and sulfate are still present. Theanion column strips these negatively charged ions andreplaces them with hydroxide ions, OH-, creating pureH2O. Although not an ion, silicate (SiO2) has a very weaknegative charge and bond and is the first measurableelement to "breakthrough" and indicate that anioncolumn regeneration is necessary. After the anion columna silica analyzer (Model 2030) is used to catch the firstsigns of this “breakthrough” occurring.
2
pure water analysisdeionized (DI)ultra pure water (UPW)
Cation Anion
H2O
Removes Cationssuch as Na+, K+
and Ca+2
Removes Anionssuch as Cl-, Br -
and SO4-2
“Don’t regenerateearly! Monitor silica
breakthrough!”
3
Boiler
Softened or Demineralized Water
Condensate return
Steam for power generation
Process steam
Industries that use Ultra Pure Deionized Water for plantprocesses and/or power generation need to maintain theintegrity of this water in their downstream applications.
Minimization of trace salt contamination is critical toprevent serious corrosion problems that can causeexpensive damage to turbines and other plantcomponents. Control of dissolved gases such as oxygenand ammonia, in proper low concentration ranges, isrequired to prevent corrosion. pH ranges must bemaintained in a narrow window for the same reasons.Proper chemistry control in these plant processes will notonly prevent costly and unscheduled outages, but willalso greatly extend the useful lifetime of the plant.
A typical plant schematic is outlined on thefollowing page, power plant chemistry.
Industries concerned with boiler water chemistry include:
• The Power Industry, See schematic for specificapplications - page 4
• The Pulp and Paper Industry, steam carryover andcontamination by sodium, sodium in condensate,deaerator outlet for oxygen concentration, sodium andsilica breakthrough on demineralizers or calciumhardness breakthrough on softeners, pH andconductivity at various points.
• The Petrochemical Industry, same applications as Pulpand Paper
Softened orDemineralizedMake Up water
• Model 1820Calcium hardnessmonitor for softenereffluent analysis
• Model 1811ELSodium & Model2030 Silica fordemineralized wateranalysis
Boiler Feed Water
• Model 1816AODissolved Oxygenfor deaerator outlet
• Model 2001 pH & 2002 pH andConductivity
• Model 1811ELSodium
• Model 1818AOOxygen Scavenger
Boiler Water
• Model 2001 and2002 pH
• ROSS™ pHElectrode
• Model 1817LL and1817HL Chloride
• Model 1811ELSodium
Steam
• Model 1811ELSodium for boilercarryover analysis
• Model 2001 pH& 2002 pH andConductivity
• ROSS pH Electrode
Condensate Return
• Model 1811ELSodium
• Model 1816AODissolved Oxygen
boiler water chemistryboiler feed water, steam, and condensate
“Only the best
sensors measure to
critical levels”
Condensate/Boiler Field Water
Cooling Water
Steam Analysis
Pure WaterProduction
Boiler Water/Blowdown
Make upDemineralizer(polisher)
Anion Bed
Cation Bed
City Water
Turbine
BoilerFeed Pump Condensate
Pump
Economizer(preheatsboiler feed
water)
Deaerator CondensatePolisher
(not used in all plants)
BoilerSteam
Generator
SuperHeaters
CoolingTower
StorageTank
Generator
Condenser
Pure Water Production• Model 1811EL Low Level Sodium Monitor for
Demineralization Mixed Bed Analysis• Model 1811AO Cation Sodium Monitor for
Demineralization Cation Exchange Analysis• Model 2030 Low Level Silica Monitor for
Demineralization Anion / Mixed Bed Analysis• Model 1820 Calcium Hardness Monitor for Softener
Effluent Analysis• Model 2001 pH/2002 pH and Conductivity Monitors
Boiler Feed Water• Model 1818 Oxygen Scavenger Monitor • Model 1810
Ammonia Monitor• Model 1811EL Low Level Sodium Monitor• Model 1816 Dissolved Oxygen Monitor• Model 2001 pH/2002 pH and Conductivity Monitors
Condensate• Model 1811EL Low Level Sodium Monitor• Model 1816 Dissolved Oxygen Monitor• Model 2001 pH/2002 pH and Conductivity MonitorsDeaerator• Model 1816 Dissolved Oxygen Monitor• Model 1818 Oxygen Scavenger Monitor• Model 2001 pH/2002 pH and Conductivity Monitors
Boiler Water / Blowdown• Model 2030 Low Level Silica Monitor• Model 1811EL Sodium Monitor• Model 1817HL and 1817LL (Equilibrium Phosphate
Treatment) Chloride Monitors• Model 2001 pH/2002 pH and Conductivity Monitors
Cooling Water Effluent• Model 1770 Total Residual Chlorine Monitor• Model 2001 pH/2002 pH and Conductivity Monitors
4
power plant chemistrywith On-Line monitors
“Corrosion in
your system is like
having termites.
CONTROL
CORROSION
with good water
chemistry”
5
Raw WaterPumping Station
2001 & 2002 pHAquaPro pH electrodes
Model 1809Fluoride
2001 pH & 2002 pHand Conductivity
ROSS pH electrodes
Mixing FlocculationSettling
Filtration ClearwellFinished Water
Distribution/Bottling
Drinking water
is subject to regulations set forth by the U.S. EPA, the state, the city, town or county and vary across national and stateborders. Bottled drinking water is controlled, so that measured values and concentrations may be listed. Manymeasurements are made in the lab on benchtop instruments, however pH, conductivity and fluoride are also measuredOn-Line. These On-Line measurements detect changes as they occur and raise warning flags if limits are exceeded.
Model: Description: Application:2001 series pH analyzer (dual channel) Inlet and outlet of drinking water plant2002 series pH and conductivity analyzers (single channel) Inlet and outlet of drinking water plant1809 Fluoride analyzer Fluoride is commonly added to drinking water and
must be controlled at approximately 1 ppm.AQUA10 Industrial pH electrode AquaPro Series best for raw water,
and pre-filtration steps of processAQUA20 Twistlock industrial pH electrode For pipe insertion applicationsAQUA30 & 3H Flat surface pH electrode module and holder For pipe insertion applications2001SC ROSS™ pH electrode For high accuracy finished water applications
drinking watermunicipal and bottled
“Save lab time,monitor fluoride levels
‘On-Line’for accurate results
24 hours a day.”
Model 2001& 2002 pH
AquaPro pH Electrodes
Model 2001 pH & 2002 pHand Conductivity
AquaPro pH Electrodes
Model 1709 Fluoride forsemi conductor andmicro electronicsindustries using HF
1770 chlorine for industrial and municipal wastewater
Model 2001 pH & 2002 pHand Conductivity
AquaPro pH Electrodes
Model 1770 Chlorine
Model 1709 Fluoride
Influent TreatmentProcess
FinalEffluent
Wastewatercan be either municipal wastewater or industrial wastewater. The chemical composition of the wastewater is measured asis enters treatment and it is also measured before release into public waters such as rivers, lakes or the ocean. Analyzersused to measure wastewater On-Line are:
Model: Description: Application:2001 series pH analyzer (dual channel) Inlet and outlet2002 series pH analyzer (single channel) Inlet and outlet1770 Total residual chlorine analyzer Final release – the 1770 measures down to 1 ppb. No
other On-Line analyzer can read this low.1709 Fluoride analyzer Hydrofluoric acid (HF) is used in the etching process
in the semiconductor and microelectronics industry.Measuring fluoride indicates HF in the wastewaterwhich has not been removed. There are also some applications in refineries which use HFalkylation units.
6
wastewatermunicipal and industrial
"Are Chlorine
levels too high in
your effluent?"
7
µS/cm (sample) mS/cm (sample)0.1 1.0 10 100 10 100 1000
2 Cell Stainless Steel Cell Electrode
D.I. water
K = 0.1
drinking water
wastewater
surface water
seawaterprocess water
conc. acids and lyes
K = 0.475
4 Cell Carbon Cell Electrode
boiler feedwater
conductivitymodel 2002CD
Features: • Panel, surface or pipe mounting
• NEMA 4X, IP65, FM Class 1,Division 2
• Automatic temperature compensation
• Timer for wash down cycle• Automated USP Function• StatFace™ Sensor Diagnostics
2002CD Monitor Specifications:Measuring Range: 0.01 µS/cm to 1000 mS/cmOperating/EnvironmentTemperature Range: -20 to 55°C (-4 to 131°F)ATC Selection: Pt 100, Pt 1000, NTC 30 kohm or NTC
100 kohmChannels: 1 channelCell Constant Range: 0.0050 to 1.999 cm-1
Signal Output: 4-20 mA or 0-20 mACalibration Mode: Cell Constant AdjustmentElectrical 20 to 253 V AC @ 45 to 65 HzRequirements: 2VAProtection Rating: NEMA 4X/IP65, Class I, Div.2Housing: Thermoplastic polyester 1/2 DIN
144x144mm bezelShipping: Dimension: (LxWxD)
16x16x14 cm (6.3x6.3x5.5 in) Weight: 1 kg (2.2 Lbs)
2002SS 2-Cell Specifications:Measuring Range: 0.01 µS/cm to 300 µS/cmNominal Cell Constant: 0.1 cm-1
Application: Boiler feedwater, ultrapure waterTemperature Range: -5 to 100°C (23 to 212°F)Maximum Pressure: 100 psi (6.9 bar)Cable Length: 5 meters (16.4 ft)Electrode Material: stainless steel
2002CC 4-Cell Specifications:Measuring Range: 10 µS/cm to 200 mS/cmNominal Cell Constant: 0.475 cm-1
Application: Drinking water, waste or process waterTemperature Range: -5 to 100°C (23 to 212°F)Maximum Pressure: 100 psi (6.9 bar)Cable Length: 5 meters (16.4 ft)Electrode Material: Epoxy/graphite
2002CD: Model 2002 conductivity monitor2002BK: Bracket kit for pipe mounting2002PK: Panel mounting kit2002SH: Protective stainless steel housing2002SS: Stainless steel conductivity 2-cell with 100
µS/cm standard (2 oz. bottle)2002CC: Carbon conductivity 4-cell with 4-pack of
standards (one each: 100 µS/cm, 1413 µS/cm,12.9 mS/cm and 111.9 mS/cm, 2 oz. bottles)
2002FC: Flowcell and adapters
2002AD: Adapter for 2002CC011005: 111.9 mS/cm conductivity standard five pack,
2 oz. bottles011006: 12.9 mS/cm conductivity standard five pack,
2 oz. bottles011007: 1413 µS/cm conductivity standard five pack,
2 oz. bottles011008: 100 µS/cm conductivity standard five pack,
2 oz. bottles
Ordering Information:
8
ROSS™ pHsuperior technology
ROSS technology is widely used in laboratory and field pH measurements.
ROSS pH technology is also available for measuring ultrapure, pure or potable water On-Line, where the highestaccuracy is needed.
Pure water samples have relatively low ionic strength andare therefore poor conductors.
If you are measuring On-Line samples that have low ionicstrength or that fluctuate in temperature, the ROSSelectrode’s patented internal reference system provides:
• superior measurement stability
• faster response
• greater accuracy
• more reproducible results than conventionalOn-Line pH electrodes
The silver-free ROSS reference system has NO dissolvedmetals. In conventional silver-chloride based referencesystems, dissolved metals precipitate. The result inclogged junctions, causing a slow, sluggish response. TheROSS internal reference system features a unique liquid-to-liquid double junction design. This avoids long-termdrift or inaccurate readings. The graph below showstypical results of how ROSS electrodes respond versusconventional pH electrodes. The ROSS electrode respondsalmost immediately to the correct buffer pH value with thechange in temperature.
Temperature Response ofROSS Electrode vs. Conventional Electrode.
4.19 100
4.13 75
4.07 50
4.01
Minutes
Conventional Electrode
ROSS Electrode
Theoretical Response
1 2 3 4 5
pH Temp (°C)
2001SC and Filling Solution
9
ROSS™ pHmodel 2001SC
Features: • Patented ROSS technology
• Platinum reference system• Superior stability• Faster response• No long-term drift• Unique silver chloride-free
reference system• Specially designed flow
cell for low conductivity samples
Markets: • Semiconductor• Power• Pharmaceutical• Drinking water
Applications: • Ultra pure water• Potable water• Aqueous solutions
2001SC SpecificationsMeasuring Range: 0.01 to 14.00 pHTemperature Range: 0 to 100°C (32 to 212°F)Drift: < 0.5 pH units for 30 daysSlope: 92-102% (54.4-60.3 mV/dec)Isopotential Point: pH 7Diameter: 12 mm (0.5 in)Length: 125 mm (5.0 in)Electrolyte: ROSS
2001SC: ROSS combination screw-cap pH electrode,complete with reference electrolyte
2001EC: Electrode cable, 1 meter20015M: Electrode cable, 5 meter2001XM: Electrode cable, 10 meter2001FC: Stainless steel flow cell with mounting bracket2001TP: ATC probe, stainless steel, 30 kohm,
1 meter cable2001XT: ATC probe, stainless steel, 30 kohm,
10 meter cable2001LN: ATC probe, stainless steel, 8.5 kohm,
5 meter cable2001TM: ATC probe, stainless steel, 1 kohm,
5 meter cable
New! ROSS 5 meter electrode kit, (1) 2001SC ROSS2001EK: electrode, (1) 2001FC, (1) 2001XT, (1) 20015M2001PA: Pre-amp, for 2001 pH monitor2001BH: Calibration beakers (2) and holder2001B2: Spare calibration beakers (2)2001CP: Consumables pack, contains 5 bottles of ROSS
reference electrolyte, buffers 4, 7, and 10 (1 pint each), for 6 months
2001FS: 5 pack fill solution, contains five 2 oz. bottles ofROSS reference electrolyte
2001F4: 4 pack fill solution, contains four 4 oz. bottles ofROSS reference electrolyte
Ordering Information:
2001 Pre-Amplifier
10
pH On-Linemodel 2001pH
Features: • 2 measurement channels
• Large, easy-to-read LED display• Backlit LCD user prompts• Automatic temperature
compensation• Solution Compensation• 4 alarms, 4 relays• Rugged aluminum housing /
NEMA 4X• Panel or surface mounting
Markets: • Power• Pulp and paper• Semiconductor• Pharmaceutical• Drinking water• Wastewater
Applications: • Rugged industrial environments• Variety of application-specific
electrodes
2001pH Monitor Specifications:Measuring Range: 0.00-14.00 pHDisplay: Red LED: pH and temperature
Backlit LCD: 2 line, alphanumeric, userinterface prompts, display mV, E0,slope, channel information
Operating/EnvironmentTemperature Range: 0 to 45°C (32 to 113°F)ATC Probe Input: 30 kohm thermistorChannels: 2 channelsSignal Output: 4-20 mA or 0-20 mA
0-5V, RS2322 analog outputs (1 per channel)
Calibration: 1 or 2 point calibration Auto buffer recognition (4, 7, 10)
Electrical 110/115V AC @ 60 Hz 10 VARequirements: 220/240V AC @ 50 Hz 10 VAProtection Rating: NEMA 4X/IP66Housing: Aluminum, 1/2 DIN 144x144 mm
bezelShipping: Dimensions: (LxWxD)
25.4x25.4x25.4 cm (10x10x10 in)Weight: 2 kg (4.5 lbs)
200100: Model 2001 On-Line pH monitor200101: Model 2001 monitor 1 channel kit, complete
with (1) 2001SC ROSS electrode, (1) 2001FCflowcell, (1) 2001TP temperature probe, (1)2001EC electrode cable, 1 meter and buffers
200102: Model 2001 monitor 2 channel kit, completewith (2) 2001SC ROSS electrodes, (2) 2001FCflowcells, (2) 2001TP temperature probes, (2)2001EC electrode cable, 1 meter and buffers
2001PA: Pre-amp for 2001pH monitor (pictured above)New! Battery operated preamp for use with ModelsPHAMP1: 2001 and 2002 pH monitors910104: 4 buffer, 475mL (1 pint bottle)910107: 7 buffer, 475mL (1 pint bottle)910110: 10 buffer, 475mL (1 pint bottle)
Ordering Information:
pH Buffers 4, 7 and 10
11
pH On-Linemodel 2002pH
Features: • Panel, surface or pipe mounting
• NEMA 4X, IP65, FM Class 1,Division 2
• Automatic temperature compensation
• Temperature probe calibration• Timer for Activating Wash Cycle• StatFace™ Sensor Diagnostics
Markets: • Power• Pulp and paper• Semiconductor• Pharmaceutical• Drinking Water• Wastewater
2002pH Monitor Specifications:Measuring Range: 0.00 - 14.00 pHOperating/EnvironmentTemperature Range: -20 to 55 °C (-4 to 131 °F)ATC Selection: Pt 100, Pt 1000, NTC 30 kohmChannels: 1 channelSignal Output: 4-20 mA or 0-20 mACalibration: 1 or 2 point calibration
Auto buffer recognition (4, 7, 10)Electrical 20 to 253 V AC @ 45 to 65 HzRequirements: 2VAProtection Rating: NEMA 4X/IP65, Class I, Div.2Housing: Thermoplastic polyester
1/2 DIN 144 x 144 mm bezelShipping: Dimension: (LxWxD)
16x16x14 cm (6.3 x 6.3 x 5.5 in)Weight: 1 kg (2.2 Lbs)
2002PH: Model 2002 pH monitor2002BK: Bracket kit for pipe mounting2002PK: Panel mounting kit2002SH: Protective stainless steel housingNew! Battery operated preamp for use with ModelsPHAMP1: 2001 and 2002 pH monitors
910104: pH 4 buffer, 475mL (1 pint bottle)910107: pH 7 buffer, 475mL (1 pint bottle)910110: pH 10 buffer, 475mL (1 pint bottle)
Ordering Information:
12
AquaPro pHmodel AQUA10model AQUA40
AQUA10 Features: • Ideal general-purpose electrode
for all your On-Line pH needs• Rugged industrial housings for
On-Line, pipe insertion orsubmersion (dip system)applications
• Built in thermistor and solution ground
• Suitable for the harshest On-Lineor wastewater samples
• Stainless steel bulb guards to protect glass pH sensing bulb from breakage and damage
AQUA40Features: • Glass body electrode for flowcell
measurements• Ideal general-purpose electrode
for all your On-Line pH needs• Screw-cap connector for various
cable lengths
AQUA10 and AQUA40 Specifications:Measuring Range: 0.01 to 14.00 pHTemperature Range: -5 to 60°CThermistor (built in): 30 kohm (AQUA10)Isopotential Point: pH 7Pressure Range: 0 to 100 psi (6.9 bar)AQUA10 Dimensions: Length: 170 mm (6.7 in) Diameter:
30 mm (1.2 in), 3/4 in NPT ThreadingAQUA40 Dimensions: Length: 120 mm (4.7 in)
Diameter: 12 mm (0.5 in)Cable Length AQUA10: 5 meters (16 ft) AQUA40 screwcap electrode does not come with cable, may be used with 2001EC and 2001XM
AQUA10: Combination pH electrode w/ATC, 5 meter cableAQUA40: Combination pH electrode w/screwcap2001TP: ATC probe, stainless steel, 30 kohm, 1 meter2001XT: ATC probe, stainless steel, 30 kohm, 10 meters2001EC: Electrode cable, 1 meter (3 ft)2001XM: Electrode cable, 10 meters (32 ft)2001FC: Stainless steel flow cell w/mounting
bracket (AQUA40)
900023: pH Electrode cleaning solution (for generalcleaning, includes four 1 oz. bottles)
900024: pH Electrode cleaning solution (for removing oiland grease contaminant’s, includes four 1 oz.bottles)
see page 10 for pH buffer ordering information
Ordering Information:
CONTACT Reference SystemThe AQUA10 and AQUA40 On-Line pH electrodes featurethe unique CONTACT Reference System. This referencesystem utilizes a polymer reference electrolyte. Thispolymer electrolyte does not hydrolyze or break down andis extremely stable. The polymer reference electrolytemakes direct CONTACT with the sample, through an open-hole junction. Problems associated with clogged junctionsare eliminated! These electrodes are Ag/AgCl double-junction combinationpH electrodes, which do not have any silver (Ag+) in theelectrolyte contacting the sample. Samples andtemperatures that precipitate silver are not a problem. • Internal reference system held under constant
conditions for high stability, low drift• Polymer matrix acts as protective barrier from
sample contamination• Long life, low maintenance electrodes which
don’t need refilling• Designed for use with models 2001 and
2002 pH Monitors
13
AquaPro pHmodel AQUA20model AQUA30
AQUA20Features: • Ideal for quick insertion and
removal applications• AQUA20 pH electrode inserts
and locks into AQUA2A adapter• Rugged industrial housings for
On-Line, pipe insertion orsubmersion (dip system)applications
• Built in thermistor and solution ground
• Bulb guards to protect glass pHsensing bulb from breakage and damage
AQUA30 Features: • Flat surface sensor helps prevent
breakage and damage• Ideal for samples containing oil,
grease or particulates• AQUA30 pH electrode screws into
AQUA3H electrode housing foreasy cleaning or replacement
• AQUA3A adapter slides ontoAQUA3H for On-Line insertion
• Built in thermistor and solution ground
AQUA20 and AQUA30 Specifications:Measuring Range: 0.01 to 14.00 pHDrift: < 0.5 pH units for 30 daysTemperature Range: -5 to 100°CThermistor (built in): 30 kohmIsopotential Point: pH 7AQUA20 Dimensions: Length: 144 mm (5.7 in)
Diameter: 25 mm (1.0 in) 3/4 in NPTon AQUA20, 1 in NPT on AQUA2A
AQUA3H Dimensions: Length: 185 mm (7.3 in)Diameter: 28 mm (1.1 in) 3/4 in NPTon AQUA3H, 1 1/2 in NPT on AQUA3A
Pressure Range: 0 to 100 psi (6.9 bar)Cable Length: 5 meters (16 ft)
AQUA20: Combination pH electrode/thermistorAQUA2A: Twistlock adapter for AQUA20AQUA30: Combination pH electrode module
(needs AQUA3H)AQUA3H: Bulkhead assembly and thermistor
for AQUA30 module, AQUA3A included
900023: pH electrode cleaning solution (for generalcleaning, includes four 1 oz. bottles)
900024: pH electrode cleaning solution (for removing oil and grease contaminant’s, includes (4) 1 oz. bottles)
see page 10 for pH buffer ordering information
Ordering Information:
HYDRAPERM Reference SystemThe AQUA20 and AQUA30 On-Line pH electrodes are idealfor the harshest samples and environments. TheHYDRAPERM Reference System is a polymer basedreference electrolyte, which hydrates and expands when itcomes in contact with an aqueous sample. Theseelectrodes have a large, rugged reference junction, suitablefor harsh On-Line samples that fluctuate in temperatureand pressure. • Long life double junction combination
Ag/AgCl electrodes
• Designed for use with models 2001 and 2002 pH Monitors
Sodium Reagent, Electrodes and Solutions
14
sodium monitormodel 1811EL
Features: • 0.01 ppb - low detection range
• No moving parts - little maintenance required
• Automatic calibration
Markets: • Power• Semiconductor• Chem / Petrochemical• Pulp and Paper
Applications: • Ultra pure water analysis• Boiler feed water• Ion exchange breakthrough• Steam analysis• R/O systems• Drum boiler water
1811EL Specifications:Measuring Range: 0.01-1000 ppb sodium,
higher levels on requestAccuracy: 0.01 ppb or 2.5%, whichever is greater
Standard deviation ± 2.5%Response Time: 50% within 2 minSignal Output: 4-20 mA or 0-20 mA
0-5V or 0-10V DCLinear or log output
Sample Temperature: 5 to 40°C (41 to 104°F) Requirements: Pressure: (0.6 - 6.9 bar) (8-100 psi)
Flow: 40 mL/min, minimumTotal acidity: < 50 ppm CaCO3
Calibration: Automatic - double known additionElectrical 100/110/115/220/240V ACRequirements: 50/60 Hz 100 wattsShipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
1811EL: Low-level sodium monitor, complete with sodiumelectrode, reference electrode, temperaturesensor, standard solutions kit, signaloutput module
181101: Electrode kit complete with (1) 100048 sodiumelectrode, (1) 100058 reference electrode and (2) cables
100058: Reference electrode, with 2 oz. bottle of referencefilling solution
150072: Reference electrode internal filling solution, five 2 oz. bottles
181140: Sodium Standard Solutions Kit, (2) 2 oz. BottlesStandard “1” – 19.1 ppm Na, Standard “2” – 192ppm Na, and one 2 oz. rinse solution
181148: Calibration kit, with carrying case, includesincludes 0.1 mL pipet, box pipet tips, washbottle, 4-ft. diffusion tubing, bottle adapter
18LL53: Consumables kit, for 1 year, consists of (6) 1 literbottles of monoethylamine reagent, diffusiontubing, adapter, standards, sodium and referenceelectrode, filling solution, O-rings, check valve,pipet tips, restriction tubing, and inlet filters.
151111: Monoethylamine reagent, with tubing, for 1 year181111: Monoethylamine reagent, with tubing,
for 2 months100048: Sodium electrode, screw cap
180011: Alarm module, with 2 separate adjustable alarms
181127: Temperature sensor181113: Sodium electrode rinse solution*New! Diisopropylamine Reagent (DIPA) (0.8 L bottle) 181190: with diffusion tubing kit*New! Diisopropylamine Reagent (6 x 0.8 L bottle) with181191: six diffusion tubing kits*New! Sodium Consumables DIPA Kit (Includes181192: Diisopropylamine Reagents). Consists of 6x0.8L
reagent with diffusion tubing kit, diffusion bottleadapter/cap, (1) standard solutions kit, (1) sodium electrode, one reference electrode, (5) 2 oz. bottles reference filling solution, one O-ring kit, one check valve, (1) set pipet tips, (1) restriction tube assembly, (2) 60 micron inlet filters, and (1) filter gasket.
*New! Diffusion Bottle Adapter/Cap Assembly for use181193: with DIPA reagent. *New! Diffusion Tubing Kit, (for use with DIPA reagent):181194: 2 x 4-inch lengths and O-rings.*New! Retro Fit Kit for DIPA: including bottle adapter/cap181195: and bottle shelf.New! 1800 series shelf/clamp for 181196: glass reagent bottles
*Must purchase retro fit kit to use DIPA reagent
Ordering Information:
Calibration Kit
15
sodium monitormodel 1811AO
Features: • 1 ppb detection limit
• Simple operation and calibration• Low maintenance requirements• Digital LCD• Automatic calibration
Markets: • Power• Semiconductor• Chem / Petrochemical
Applications: • Cation exchange breakthrough• For high acid samples• Increase the effective run time on
cation exchangers• Drum boiler water
1811AO Specifications:Measuring Range: 1 ppb-200 ppm sodiumAccuracy: ± 2 ppb up to 10 ppb 5% of
reading up to 200 ppmResponse Time: 50% within 2 minSignal Output: 4-20 mA or 0-20 mA
0-5V or 0-10V DCLinear or log output
Sample Temperature: 5 to 45°C (41 to 112°F)Requirements: Pressure: (0.6 - 6.9 bar) (8-100 psi)
Flow: 25 mL/min minimumTotal acidity: < 250 ppm CaCO3
Calibration: Automatic - double known additionElectrical 110/115/220/240V AC 50/60 HzRequirements: 100 wattsShipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
1811AO: Cation sodium monitor, complete with sodiumelectrode, reference electrode, temperaturesensor, signal output module, standard solution kit
181102: Electrode kit complete with (1) 100045 sodiumelectrode, (1) 100056 reference electrode and(2) cables
100045: Sodium electrode100056: Reference electrode, with 2 oz. bottle of
filling solution181073: Reference electrode internal filling solution,
five 2 oz. bottles181149: Calibration kit, with carrying case, includes 0.5
mL pipet, pipet tips, diffusion bottle adapter,wash bottle, tubing, rinse solution (shown above)
181150: Consumables kit, for 1 year, consists of (12) 2liter bottles reagent, diffusion tubing, standardsolutions kit, sodium electrode, referenceelectrode, filling solution, O-ring kit, check valve,pipet tips, restriction tube assembly and inlet filters
181130: Acid Reagent, 2 liter bottle, for 30 days(181160 diffusion tubing not included)
181160: Diffusion tubing, (3) 5’ 8” lengths with O-rings180011: Alarm module, with 2 separate adjustable alarms181127: Temperature sensor181113: Sodium electrode rinse solution181140: Sodium standard solution kit181141: High level sodium standard solution kit
Ordering Information:
Fluoride Reagent and Electrodes
16
fluoride monitormodel 1809AO
Features: • 0.01 to 100 ppm
• Solid state electrode• Simple operation• No moving parts• Simple calibration• Correlates well with lab
measurements• Designed to measure clean water
Markets: • Potable water• Bottled water• Municipal drinking water
Applications: • Fluoridation control• Fluoride level monitoring
1809AO Specifications:Measuring Range: 0.01-100 ppm fluorideAccuracy: 0.1 ppm or 10% of reading,
whichever is greaterResponse Time: 90% within 2 min function of flowSignal Output: 4-20 mA or 0-20 mA
0-5V or 0-10V DCLinear or log output
Sample Temperature: 5 to 35°C (41 to 95°F)Requirements: Pressure: (0.6 - 6.9 bar) (8-100 psi)
Flow: 40 mL/minTotal alkalinity: < 200 ppm CaCO3
Calibration: Automatic - double known additionElectrical 110/115/220/240V AC 50/60 HzRequirements: 100 wattsShipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
1809AO: Low-level fluoride monitor, complete withfluoride electrode, reference electrode,temperature sensor, standard solutions (100and 1000 ppm), signal output module
100029: Fluoride electrode, screw cap100056: Reference electrode, screw cap181073: Reference electrode internal filling solution, five
2 oz. bottles940907: Fluoride standard solution, 100 ppm,
475mL (1 pint bottle)110902: Fluoride standard solution, 1000 ppm,
475mL (1 pint bottle)182011: Reagent, acid, for 60 days
180949: Calibration kit, with carrying case, includes 0.5ml pipet, pipet tips, fluoride standards (100 and1000 ppm), inlet filter, wash bottle and diffusionbottle adapter, tubing, solutions
180950: Consumables kit, for 1 year, consists of six 1 literbottles of reagent, diffusion tubing, standards,fluoride electrode, reference electrode, fillingsolution, O-ring kit, check valve, pipet tips,restriction tube assembly and inlet filters.
181170: Inlet filters, stainless steel, 60 micron filters with gaskets, pack of 2, for 6 months
181125: Restriction Tube Assembly204847-001: Calibration pipet, 0.5 mL204846-001: Pipet tips, set of 100
Ordering Information:
Fluoride Standard and Electrodes
17
fluoride monitormodel 1709
Features: • 0.01 to 1000 ppm
• Solid state electrode• Choice of measuring range• Measures unfiltered wastewater• Reagent buffers up to 500 ppm
acidity / alkalinity• Reliable chemistry• Low cost of operation
Markets: • Semiconductor• Industrial wastewater• Municipal wastewater
Applications: • Compliance monitoring
1709 Specifications:Measuring Range: 0.01-1000 ppm fluoride. User to
select 2, 3, or 4 decades within thisrange. Higher ranges available
Accuracy: ± 10 ppb or ± 10% of readingwhichever is greater
Response Time: 1 minSignal Output: 0-5V DC
4-20 mAOutputs to drive recorder
Sample Temperature: 0 to 40°C (32 to 104°F)Requirements: Pressure: (0.1 - 1.4 bar) (2-20 psi)
Flow: 2-20 L/min (0.5-5 gal/min)Total alkalinity: 0-500 ppm CaCO3
Calibration: 2 point calibrationElectrical 115V AC (170901) 50/60 HzRequirements: 220V AC (170903) 50/60 Hz
100 wattsShipping: Dimensions: (LxWxD)
154x64x33 cm (60x25x13 in)Weight: 102 kg (225 lbs)
170901: Fluoride monitor, 115V, complete with fluoride electrode (100029), and reference electrode(100031)
170903: Fluoride monitor, 220V, complete with fluoride electrode(100029), and reference electrode(100031)
100029: Fluoride electrode, screw cap100031: Reference electrode, with 2 oz. bottle of internal
filling solution150071: Reference electrode internal filling solution, for
use with 100031 reference electrode, (5) 2 oz. bottles
170950: Consumables kit, for 1 year, contains fluoridereagent and standard
170930: Fluoride reagent, for 30 days170959: Spare parts kit, consists of fluoride electrode,
reference electrode, filling solutions, inletscreens, pump seals, fuses, O-ring kit, checkvalves and carbon filter.
940907: Fluoride standard solution, 100 ppm, 475mL (1 pint bottle)
110902: Fluoride standard solution, 1000 ppm, 475mL (1 pint bottle)
170013: Tubing kit150084: Signal linearizer207303-A01: Cable, screw cap to SHV connector
Ordering Information:
Chloride Reagent and Electrodes
chloride monitormodel 1817HL
Features: • 0.1 ppm detection limit
• Simple operation and calibration• No moving parts• Wide range of detection• Digital LCD• Chloride specific measurement
Markets: • Power• Semiconductor• RO systems
Applications: • Detects condenser leaks inseawater cooled power plants
• Boiler water monitoring• RO feedwater monitoring
1817HL Specifications:Measuring Range: 0.1-100 ppm chloride Higher
ranges availableAccuracy: ± 0.1 ppm or 10%, whichever
is greaterResponse Time: 90% within 2 minSignal Output: 4-20 mA or 0-20 mA
0-5V or 0-10V DCLinear or log output
Sample Temperature: 5 to 35°C (41 to 95°F)Requirements: Pressure: (0.6 - 6.9 bar) (8-100 psi)
Flow: 40 mL/minTotal alkalinity: < 50 ppm CaCO3Sulfite cannot be present in sample
Calibration: Automatic - double known additionElectrical 110/115/220/240V AC 50/60 HzRequirements: 100 wattsShipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
1817HL: Chloride monitor, complete with chloride andreference electrodes, standard solutions kit, andsignal output module
100025: Chloride electrode, screwcap100057: Reference electrode, screwcap181140: Standard solutions kit181141: High level standard solutions kit
182011: Reagent, Acid, with tubing, for 60 days180011: Alarm module, 2 adjustable alarms181060: Diffusion tubing (thin-walled), (4) 2 foot lengths
with O-rings181125: Restrictor Tube Assembly204847-001: Calibration pipet, 0.5 mL204846-001: Pipet tips, set of 100
Ordering Information:
18
1817LL Sample Cooler
chloride monitormodel 1817LL (Low-Level)
New!
Features: • Measures down to 5 ppb chloride• Low cost of operation• QC Sampling Capability:
- Validation using standards- Grab samples- Alternative to lab analyses
• Integrated sample temperaturecontrol for lower levels of detection
• Low maintenance• Ease of calibration
Markets: • Power Generation• Reverse Osmosis
Applications: • Boiler water chloridemeasurements
• Equilibrium Phosphate Treatment (EPT) chloridemeasurements
• RO Effluent
1817LL Specifications:Measuring Range: 5ppb to 10ppm chlorideSignal Output: 4-20 mA or 0-20 mA
0-5V or 0-10V DCLinear or log output
Precision: 10% of reading or ± 5 ppb, whicheveris greater, within ± 5˚ C of calibrationtemperature.
Drift: 0.1 ppm per month or 10% of readingwhichever is greater.
Sample Temperature: 5 to 45 ˚C (40 to 113 ˚F)Requirements: Pressure: (0.6 - 6.9 bar) (8-100 psi)
Flow: 40 mL/minTotal alkalinity: < 50 ppm CaCO3
Sulfite must not be present. Cooled Sample Temp: 5-12 ˚CCalibration: 1 - 3 - point calibration using dynamic
calibrator (see page 27)Electrical 100/115/220 or 240V AC, ± 10%, Requirements: 50/60 Hz, 100 watts.Shipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
1817LL: Low-Level Chloride monitor with cooler, 110V1817LL100: 1817LL, 100V1817LL230: 1817LL, 230V100025: Chloride electrode, screwcap100057: Reference electrode, screwcap941707: 100 ppm Chloride standard,
475mL (1 pint bottle)
1817CAL: Includes Dynamic calibrator (Cat. No. 15DC15),and 100ppm Chloride standard (Cat. No.941707) in an easy-to-use kit.
*182011: Acid Reagent for 60 days operation (one literbottle) with one 2 foot length thin-walled tubingand O-rings
*Contains hazardous material.
Ordering Information:
19
Ammonia Reagents, Electrodes and Solutions
20
ammonia monitormodel 1810AO
Features: • 10 ppb detection limit
• Direct measure of ammonia• Continuous readings• Simple operation and
automatic calibration• Digital LCD
Markets: • Power• Pulp and Paper• Chem / Petrochemical
Applications: • Boiler feed water
1810AO Specifications:Measuring Range: 10 ppb-10 ppm ammoniaAccuracy: ± 0.03 ppm
Standard deviation ± 5%Response Time: 90% response within 1.5 minSignal Output: 4-20 mA or 0-20 mA
0-5V or 0-10V DCLinear or log output
Sample Temperature: 15 to 35°C (59 to 95°F)Requirements: Pressure: (0.6 - 6.9 bar) (8-100 psi)
Flow: 40 mL/min Total alkalinity: < 250 ppm CaCO3
Calibration: Automatic - double known additionElectrical 110/115/220/240V AC 50/60 HzRequirements: 100 wattsShipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
1810AO: Ammonia monitor, complete with sensingelectrode, reference electrode, temperatureprobe, standard solution kit, signal outputmodule
181049: Calibration kit, with carrying case, includesstandards, electrodes, bottles, tubing, solutions
180011: Alarm module, 2 adjustable alarms
181050: Consumables kit, for 1 year181030: Reagent, 2 liter bottle181040: Ammonia standard solutions kit100047: Ammonium electrode100056: Reference electrode, with 2 oz. bottle of
filling solution181127: Temperature sensor
Ordering Information:
Dissolved Oxygen Probe and Filling Solution
21
dissolved oxygenmodel 1816AO
Features: • Low-level detection - 0.1 ppb
• Galvanic cell with low-levelguard ring
• 316 stainless steel flow cell• Digital LCD readout• Built in alarms and relays• Pre-assembled teflon membrane
module for easy replacement
Markets: • Power• Pulp and Paper• Chem / Petrochemical
Applications: • Boiler feed water• Ultra pure water• Process steam• Deaerator outlet• Condensate• Oxygen feed control for plants
using oxygen treatment chemistry
1816AO Specifications:Measuring Range: 0.1 ppb-300 ppb dissolved oxygenCalibration Range: 0-10 ppm oxygen in water
saturated airAccuracy: 0.1 ppb ± 2%, whichever is greaterResponse Time: 1 min, from high to low levelsSignal Output: 4-20 mA or 0-20 mA
0-5V or 1-5V DCBi-directional RS232, 2 relays
Sample Temperature: 2 to 45°C (35 to 113°F)Requirements: Flow: 50-200 mL/min pH: > 4
Pressure: < 4 bar (60 psi)Calibration: Automatic in water saturated airProtection Rating: NEMA 4X/IP65Electrical 115/230V AC 50/60 HzRequirements: 50 wattsShipping: Dimensions: (LxWxD)
16x26x9 cm (6.3x10.24x3.54 in) Weight: 4.9 kg (10.8 lbs)
1816AO: Low-level dissolved oxygen monitor, completewith flow cell, maintenance kit and electrodewith 10 foot shielded cable, 115/230V
1816A2: Low-level dissolved oxygen monitor, 115/230V(without electrode)
181621: Low-level dissolved oxygen probe, with 10 footshielded cable
181621X: Low-level dissolved oxygen probe, customlength shielded cable (30 foot max)
181622: Maintenance kit, with membrane module, o-ring, and fill solution
1816FP: Portable fluidics panel, with needle valve andbypass, quick connect fitting, for easy hook up(shown above with monitor and electrodeattached)
223115-S01: Flow cell assembly
Ordering Information:
Silica Reagent and StandardGrab Sampler
22
silica monitormodel 2030
Features: • 0.5 ppb detection limit
• 3 reagent addition CEGB method• 6 stream capability (1 standard)• Ease of use with digital
alphanumeric readout• Grab sample capability• Accurate reagent metering for
low and high levels• Fully programmable for individual
needs - 10 stored methods• Fully programmable AUTOCAL™• Analog and digital outputs• Stores last 25 calibrations and
last 120 measurements• Rugged NEMA 4X enclosure
Markets: • Power• Semiconductor• Pharmaceutical• Pulp and Paper• Chem / Petrochemical
Applications: • Demineralizer effluent• Boiler water
2030 Specifications:Measuring Range: 0-500 ppb SiO2
Method: Silica in water using the absorptionband at 810 nm with referencewavelength at 450 nm single beamdual wavelength using fiber-opticprobe in the transflection mode
Limit of Detection: 0.5 ppbResponse Time: 8-10 min, 0-100 ppb
15 min, 100-500 ppbSignal Output: 0-10 mV
0-100 mV0-1V4-20 mARS232 bi-directionalModem
Sample Temperature: 5 to 70°C (41 to 158°F)Requirements: Pressure: (0.2 - 3 bar) (2-50 psi)
Flow: 50-900 mL/minSample Streams: 1 standard, 2-6 optionalCalibration: Automatic - fully programmableEnclosure Rating: NEMA 4X, IP65Electrical 110/115/220/240V AC 50/60 HzRequirements: 100 wattsShipping: Dimensions: (LxWxD)
76x76x48 cm (30x30x19 in) Weight: 44 kg (96 lbs)
203000: Silica analyzer, single stream2030S2: Silica analyzer, 2 streams2030S3: Silica analyzer, 3 streams2030S4: Silica analyzer, 4 streams2030S5: Silica analyzer, 5 streams2030S6: Silica analyzer, 6 streams*2030RE: Reagent kit, 1 month*2030IR: International reagent kit, 1 month2030RT: Reagent holder shelf203002: 20 ppb silica standard, (4) 475 mL
(1 pint) bottles*Contains hazardous material
203010: 100 ppb silica standard, (4) 475 mL(1 pint) bottles
203020: 200 ppb silica standard, 5 liters (1.3 gallons),for automatic calibration
2030MK: Maintenance kit, 3 months, check valves forreagent tubing, pump seals, silicon oil, reactioncell O-ring kit, C-flex tubing
2030GS: Silica grab sample kit2030GP: Silica grab sample kit spare parts2030LA: Replacement tungsten lamp
Ordering Information:
Chlorine Electrode and Standards
177001: Total residual chlorine monitor, complete withchlorine electrode, and manual, 115V
177003: Total residual chlorine monitor, complete withchlorine electrode, and manual, 220V
100020: Chlorine electrode177015: Calibration equipment kit, for use with
Calibration refill kit (177013)177050: Chlorine consumables kit177013: Calibration refill kit, for use with calibration
equipment kit*177011: Reagent, 900 mL concentrated acid and 54
grams Iodide reagent powder, requires dilutionwith deionized water to 5 gallons, for 30 days
*Contains hazardous material
177012: Iodide powder reagent, four 54 gram bottles, 4 months
177014: Standards A and B, 4 bottle pack, requires177041 and 177042 reagents
177041: Iodide reagent, five 2 oz. bottles, for use with177014 standards
177042: Acid reagent, five 2 oz. bottles, for use with177014 standards
170013: Tubing kit948201: Electrode polishing strips, twenty-four,
6 inch strips150084: Signal linearizer
Ordering Information:
Features: • 1 ppb detection limit
• Provides lowest level of detection• Reliable• Low operating cost• Solid state electrode• U.S. EPA approved method• Measures unfiltered wastewater• Measures other oxidants
such as bromine
Markets: • Power• Desalination plants• Reverse osmosis• Wastewater treatment
Applications: • Cooling water• RO membrane protection• Effluent samples• Compliance monitoring
1770 Specifications:Measuring Range: 0.001-10 ppm total residual chlorine
4-decade scale standard. Other ranges available
Accuracy: ± 10% of readingResponse Time: 90% within 2 minSignal Output: 4-20 mA or 0-5VSample Temperature: 5 to 45°C (40 to 113°F)Requirements: Flow: 2-20 L/min
Total alkalinity: < 500 ppm CaCO3
Calibration: 2 point calibrationElectrical 115V AC (177001) 50/60 HzRequirements: 220V AC (177003) 50/60 Hz
230 wattsShipping: Dimensions: (LxWxD)
154x64x33 cm (60x25x13 in)Weight: 102 kg (225 lbs)
chlorine monitormodel 1770 total residual
23
Calcium Reagent, Electrodes and Solutions
24
1820AO Specifications:Measuring Range: 25 ppb-500 ppm calcium hardness
as CaCO3
Accuracy: ± 10% of reading or 10 ppb,whichever is greater within ± 10°C ofcalibration temperature
Response Time: 50% within 2 min function offlow and volume
Signal Output: 4-20 mA or 0-20 mA 0-5V or 0-10V DCLinear or log output
Sample Temperature: 5 to 40°C (41 to 104°F)Requirements: Pressure: (0.6 - 6.9 bar) (8-100 psi)
Flow: 40 mL/min, minimumTotal alkalinity: < 250 ppm,No filming amines; cannot contain
sulfite > 2 ppm chelants such as EDTAmust not be present
Calibration: Automatic - double known additionElectrical 100/115/220/240V AC 50/60 HzRequirements: 100 wattsShipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
Features: • 25 ppb up to 500 ppm
• Wide range• Simple operation• No moving parts
Markets: • Power• Pulp and Paper• Chem / Petrochemical• Drinking water
Applications: • Zeolite softener effluent monitoring
• Water softening• Blending applications
calcium monitormodel 1820AO
1820AO: Calcium hardness monitor, complete withcalcium electrode, reference electrode,temperature sensor, standard solutions kit,signal output module
182049: Calibration kit, with carrying case, includesstandards, tubing, solutions, 0.5 mL pipet, pipettips, standards, inlet filter, wash bottle,diffusion bottle adapter
*182011: Reagent, acid, for 60 days*182051: Consumables kit, for 1 year, consists of (6) 1
liter bottles reagent, diffusion tubing andadapter, standards, calcium electrode, referenceelectrode, filling solutions, O-ring kit, checkvalve, pipet tips, restriction tube assembly, andinlet filters.
*Contains hazardous material
180011: Alarm module, with 2 adjustable alarms182040: Calcium standard solutions kit181073: Reference electrode internal filling solution,
five 2 oz. bottles100049: Calcium electrode, screw cap100056: Reference electrode, screw cap, with 2 ounce
bottle of filling solution181120: Inlet filters, 4 pack, for 1 year181127: Temperature sensor
Ordering Information:
Reagent, Electrodes and Solutions
25
oxygen scavengermodel 1818AO
Features: • 1 ppb detection limit
• Simple operation• No moving parts• Alarm and control capability• Measures most oxygen scavengers• Solid state electrode• Unique chemistry
Markets: • Power• Pulp and Paper• Chem / Petrochemical
Applications: • Boiler feed water• Hydrazine• Elimin-Ox®†
• Carbohydrazide• DEHA and others
† Elimin-Ox is a registered trademark of NALCO Chemical Co.
1818AO Specifications:Measuring Range: Hydrazine: 0-200 ppb
Elimin-Ox Carbohydrazide: 0-1000 ppb
Accuracy: Hydrazine: 0-50 ppb ± 2 ppb or 10%0-200 ppb ± 2 ppb or 15% Elimin-Ox: ± 30 ppb or 10%
Response Time: 90% within 4 minSignal Output: 4-20 mA or 0-20 mA
0-5V or 0-10V DCLinear or log output
Sample Temperature: 15 to 40°C (59 to 104°F)Requirements: Pressure: (0.6 - 6.8 bar) (8-100 psi)
Flow: 40 mL/min, minimumCalibration: Hydrazine: 1 or 2 point calibration
using dynamic calibratorElimin-Ox: 2 point calibration usingdynamic calibrator (see page 27)
Electrical 110/115/220/240V AC 50/60 HzRequirements: 100 wattsShipping: Dimensions: (LxWxD)
65x45x27 cm (26x17x11 in)Weight: 31.4 kg (69 lbs)
1818AO: Oxygen scavenger monitor, complete withsensing electrode, reference electrode, signaloutput module (note: comes installed withHYDRAK, ELIMAK software and instructions forinstallation are included)
HYDRAK: Application kit, for measuring HydrazineELIMAK: Application kit, for measuring NALCO ELIMIN-OX
Carbohydrazide100022: Iodide Sensing electrode, screwcap100056: Reference electrode, screwcap180011: Alarm module, 2 adjustable alarms
*181850: Consumables kit, for 1 year, consists of (6) 1liter bottles reagent, diffusion tubing, iodidereagent, reference electrode, filling solution, O-ring kit, check valve, restriction tube assemblyand inlet filters.
*181811: Reagent, with tubing, for 6 months181127: Temperature sensor181170: 60 micron inlet filters, 2 pack, for 1 year151810: Hydrazine standardizing solution,
475mL (1 pint bottle)180096: Syringe kit, for use with 15DC15
dynamic calibrator181860: Diffusion tubing and O-rings*Contains hazardous material
Ordering Information:
accessoriesfor On-Line products
26
Steam conditioning:The 1803 is designed to take a high pressure steam sample (e.g.the process steam used in power plants, paper mills, oil refineriesetc.) and reduce the temperature and pressure down to the levelsrequired by our On-Line analyzers. Process steam is used in manyindustries; it is the analysis of this steam that has made On-Lineanalyzers so important in the power, paper, petrochemical andother industries.• The 1803 can handle pressures of up to 20,897 K Pa (3030 psi).
The usual average pressure of process steam is approximately6,896 K Pa (1000 psi)
• The 1803 can reduce the temperature of the sample from 538°C(1000°F) to under 38°C (100°F)
• No electrical requirements - the 1803 is purely mechanical,requiring no electrical hook up. This means that it can be used inmultiple countries regardless of the voltage requirements. The1803 can also be used in hazardous locations without anydanger of explosion
• The 1803 has a mechanical temperature shut off valve which willtrip if the temperature exceeds 40°C (104°F). This can happenwhen a cooler fails or the cooling water becomes too hot. Thevalve diverts the hot sample away from the On-Line monitor,avoiding costly damage
Features:• Thermal shut off valve• Sample cooler• Pressure reduction element• Temperature indicator• Back pressure relief valve
Markets:• Power• Pulp and Paper• Chem / Petrochemical
Applications:• Reduce temperature and pressure of steam samples for analysis
steam conditioner model 1803
Thermo Westronics SV100 Video Recorder
The SV100 takes touch screen technology to the next level withextensive use of intuitive Windows® style menus.
The SV100 comes standard with dual RS232 and RS485 interfaceswith MODBUS protocol support.
• Inputs: Accepts 6, 12 or 18 inputs and is designed with 3 cardslots to accommodate any combination of analog input cards andcontact output/digital input cards. Up to 30 calculated pointsincluding custom entry of algebraic equations. All pointsscanned at 125 mS.
• Display Options: Inputs and calculated points can be displayedin a wide variety of user-defined formats such as Vertical Trend,Horizontal Trend, Bargraph, Digital, Alarm Summary, Overviewand/or Bitmap Screens. “Thumbnails” of all configured screensare on one page eliminating need to scroll through numerousselections. Points can be programmed to flash or change coloron alarm. Intuitive touch screen and Windows style menus allowstraightforward programming and operation without requiring theuse of cumbersome function keys and keypads. Review ofhistorical data is flexible with the touch of the fast forward andrewind buttons.
• Storage Media: 8 MB Internal Flash Memory protectsconfiguration and data from power loss. 16MB Internal RAM
permits the operator to search through an extensive amount ofhistorical data effortlessly and without delay. RemovableStorage: 3.5” floppy disk, ATA flash memory card and Zip disks.User-selectable for Cyclical or Fill to End mode of storage.Measured values are saved to media as an average orinstantaneous value. No data is lost during media change.
• Networking: 10 Base-T Ethernet. RS232, RS485 with MODBUSRTU or ASCII as standard feature. Real time remote monitoring anddata backup.
• Additional Features: A standard parallel printer port supportsPrint Screen, Alarms and/or Time of Day or Interval Logs. EventMessage feature allows the operator to mark the trend screens withcustom messages. IP65 Front Panel. Modular Compact Design.
Note: Specially configured for each application, please call for ordering information.
†Windows is a registered trademark of Microsoft Corporation
New! paperless recorder
Sample requirements: Temperature: up to 538°C (1000°F)Pressure: 20,897 K Pa (3030 psi)Panel dimensions: 30.5x91.5x17 cm (12x36x6.5 in)Material: Stainless steel
180300: Steam sample conditioner
Specifications: Ordering Information:
Paperless Recorder
Steam Conditioner
27
By using the QC Sampler, operators can temporarily interrupt theflow of water to 1800 Series monitors and substitute it withsamples coming from the QC Sampler. In this way, samples fromother parts of the plant, or validation and calibration standardscan be analyzed. The QC Sampler allows for rapid sampling whereno On-Line instrumentation is present, and providestroubleshooting to validate readings without disturbing On-Line operations.
Features:• Compatible with all 1800 series monitors• Portable design• Easy to install• Introduce standards or samples into the monitor for analysis
1800 Series QC Sampler
Dynamic Calibrator
Many analyzers claim to measure in the low ppb range but it can be difficult to verify that an On-Line instrument is accuratelyreading at this low-level. Part-per-billion standards are difficult tomake and maintain, and transporting grab samples for laboratoryanalysis is difficult.
The Low-Level Verification system uses On-Line dynamic dilution.The key component of this system is the Dynamic Syringe Pumpwhich can deliver a steady flow rate of solution or standard downto 0.1 mL/min. The low-level verification kit includes an injectionport, which is installed into the process downstream offlow regulation.
Calculation for the expected concentration of the standard:
The expected reading is the sample reading plus the expectedstandard concentration.
The Dynamic Calibrator can be used for Low-Level Verification of allmodel 1800 Series ISE Analyzers!
low-level verification system
accessoriesfor On-Line products
ElectricalRequirements: 9V DC, 9 wattsInput: 115VAC/60Hz Adapter, 230VAC/50Hz AdapterFlow Rate: 40 mL/min nominal set by pressure regulatorCompatibility: All 1800 Series MonitorsDimensions: 14.5 x 10 x 6 in (h.w.d.);
36.8 x 25.4 x 15.2 cm (h.w.d.)Weight: 10 pounds/4.5 kgTemperature: 5 to 45 °CApprovals: CE, CSA
18GRAB: 1800 Series QC Sampler, includes (1) 1-liter polypropylenesample bottle, tubing, fittings, power supplies and instruction sheet.
18GBTL: 1-Liter Polypropylene Bottle with Cover, case of 418GTBK: QC Sampler Replacement Tubing Kit224329-A01: Wall Adapter, 115V224330-A01: Wall Adapter, 230V
Specifications: Ordering Information:
X= Expected Standard
Concentration
Injected Standard
(Sample + Injected Standard)
Injected StandardConcentration
15DC15: Dynamic Calibrator, complete with syringe pump and syringekits (150096 and 180096) and mounting bracket, 115V.
15DC20: Dynamic Calibrator, 220V216970-AOI: Low-Level verification kit, includes T-fitting and tubing
Ordering Information:
Low-Level Verification System
QC Sampler
terms and conditionswarranty informationFor products not listed in this warranty statement, please visit our website at www.thermo.com
28
Minimum order:
The minimum order requirement is $100 for Orion On-Lineproducts. An order is considered to be a purchase order forproducts to be shipped to a single location. International minimumorder requirements may vary. Contact your international coordinatorfor details.
Rush orders:
For customers in the U.S., rush orders received before 12 pmEastern Time will be shipped the same day. Rush orders receivedafter 12 Noon Eastern Time will be shipped the next business day.For customers and dealers in Canada, rush orders will be shippedwithin 2 business days. For customers and dealers outside the U.S.and Canada, contact your international coordinator for rush orderscheduling. All rush orders carry a $50 incremental charge perorder. FOB: Beverly. Freight charges are prepaid and added orfreight collect. All rush order processing is subject to stockavailability.
Returning goods:
Permission to return merchandise purchased from Thermo ElectronCorporation must be obtained prior to return. Contact within 30days of receipt of goods for a return authorization number:
Thermo Electron CorporationEnvironmental Instruments DivisionWater Analysis166 Cummings Center, Beverly, MA 01915. Phone 978-232-6000, fax 978-232-6015 (inside U.S. and Canada), fax 978-232-6031 (outside U.S. and Canada), or call toll free 800-225-1480.
Hazardous materials:
Some materials are designated corrosive/oxidizer by DOT and IATA.Some materials may require special labeling and handling. Carriersmay add additional freight charges for handling/transporting thesematerials. Consolidating such material with other products may beprohibited. Additional freight charges are billed to you per FOBterms. Advise Thermo Electron Corporation of shipping instructionsfor these hazardous materials to reduce your freight costs.
Restocking charge:
Permission to return new, excess inventory must be obtained priorto return. If any item is authorized to be returned for credit as aresult of an incorrect purchase without a reorder, a 25% restockingcharge of the price paid for the product will be made. Internationalcustomer’s restocking fee of 25% will be off the international price.Only new (in-the-box) goods may be returned within 30 days ofshipment from Thermo. Older items, 9-digit parts, anddiscontinued items cannot be returned for credit.
Short shipments:
Thermo must be notified within 30 days of receipt of invoice of anyitem or billing discrepancies. All substantiated claims will beremedied by a credit memo and a new order placed for shortshipment. Any shipment discrepancy claimed after 30 days of
invoice date will not be honored and credit will not be issued by Thermo.
Force majeure:
Thermo shall not be liable for failure to perform or for delay inperformance due to fire, flood, strike, or other labor difficulty, act ofGod, act of any governmental authority or of the purchaser, riot,embargo, fuel or energy shortage, wrecks or delays intransportation, inability to obtain necessary labor, materials, ormanufacturing facilities from usual sources, or due to any causebeyond its reasonable control. In the event of a delay inperformance due to any such cause, the date of delivery or time forcompletion of performance will be extended by a period of timereasonably necessary to overcome the effect of such delay.
Warranty:
Orion On-Line monitoring products are warranted to be free fromdefects in material and workmanship for a period of 12 monthsfrom date of installation or 18 months from date of shipment,whichever is earlier, when used under normal operating conditionsand in accordance with the operating limitations and maintenanceprocedures given in the instruction manual, and when not havingbeen subjected to accident, alteration, misuse, or abuse. Thiswarranty is also conditioned upon expendable and consumableitems (diffusion tubing, electrodes, and all solutions) being storedat temperatures between 5°C and 45°C (40°F and 110°F) in a non-corrosive atmosphere and within the shelf life printed on the product.
In the event of failure within the warranty period, Thermo, or itsauthorized dealer, will, at Thermo’s option, repair or replace theproduct nonconforming to the above warranty, or will refund thepurchase price of the unit.
The warranty described is exclusive and in lieu of all otherwarranties whether statutory, express, or implied including, but notlimited to, any implied warranty of merchantability or fitness for aparticular purpose and all warranties arising from the course ofdealing or usage of trade. The buyer’s sole and exclusive remedy isfor repair or replacement of the non-conforming part thereof, orrefund of the purchase price, but in no event shall Thermo (itscontractors and suppliers of any tier) be liable to the buyer or anyperson for any special indirect, incidental, or consequentialdamages whether the claims are used in contract, in tort (includingnegligence), or otherwise with respect to or arising out of theproduct furnished hereunder.
On-Line products used at overseas nuclear facilities are alsosubject to Thermo nuclear terms and conditions. Contact Thermo ifyou do not have a copy.
Representations and warranties made by any person, including itsauthorized dealers, distributors, representatives, and employees ofThermo, which are inconsistent or in addition to the terms of thiswarranty shall not be binding upon Thermo unless in writing andsigned by one of its officers.
© Copyright 2003 Thermo Electron Corporation. All rightsreserved. Thermo Electron Corporation, question everything,Analyze. Detect. Measure. Control., AUTOCAL, Pure Water,ROSS and StatFace are trademarks of Thermo ElectronCorporation. Guaranteed Success and The Technical Edge areservice marks of Thermo Electron Corporation. PerpHecTROSS are protected by U.S. patent 4,495,050.
The specifications, descriptions, drawings, orderinginformation and part numbers within this document aresubject to change without notice. This publicationsupersedes all previous publications on this subject.
Be sure to log on to thermo.com for all thelatest information concerning all productsand new releases.
Thermo Electron CorporationEnvironmental Instruments DivisionWater Analysis166 Cummings CenterBeverly, MA 01915-6199 USATel: 978-232-6000Dom. Fax: 978-232-6015Int’l. Fax: 978-232-6031
Lit 242720-001 Rev. A 2/03
Customer SupportToll Free: 800-225-1480 www.thermo.com Dom. e-mail: [email protected]’l. e-mail: [email protected]