ordering information - schreder...p7 - luco owlet control (dimming enabled) sxxx - custom...

4
SmartLume ORDERING INFORMATION Luminaire Flux Code Color Temp.(70+ CRI) Optic Voltage & EL Class Finish SMART1-US 12L041 (12 LEDs, 4.1K lms, 33W) + 12L055 (12 LEDs, 5.5K lms, 48W) + Standard NW (Neutral 4000K) Optional * WW (Warm 3000K) ^ CW (Cool 5700K) T2M (Type 2 Roadway 5172) T3M (Type 3 Roadway 5171) T3C (Type 3 Local 5173) T4M (Type 4 5174) T5S (Type 5 5175) T5Q (Type VS Square 5242) Standard SV (120-277V CLI) Optional * HV (347-480V CLI) # GY (RAL7040T Grey) BK (RAL9011T Black) WH (RAL9016T White) BZ (RAL8019T Bronze) SMART2-US 24L073 (24 LEDs, 7.3K lms, 56W) 24L093 (24 LEDs, 9.3K lms, 77W) 24L112 (24 LEDs, 11.2K lms, 98W) 36L146 (36 LEDs, 14.6K lms, 117W) 36L177 (36 LEDs, 17.7K lms, 155W) + SMART3-US 48L200 (48 LEDs, 20.0K lms, 166W) 48L214 (48 LEDs, 21.4K lms, 183W) 60L231 (60 LEDs, 23.1K lms, 180W) 60L284 (60 LEDs, 28.4K lms, 238W) x Preliminary data, date of revision: 09/22/2017 Copyright © Schréder ® Lighting LLC 2016 - Executive Publisher: Fred Kern. 1415 West 22nd Street, T Floor, Oak Brook, IL 60523. The information, descriptions and illustrations herein are of only an indicative nature. Due to advanced developments, we may be required to alter the characteristics of our products without notice. As these may present different characteristics according to the requirements of individual countries, we invite you to consult us. ANSI/UL 1598/CAN/CSA C22.2 No.250.0-08, 3 rd Ed. Control Options * P7 - LuCo Owlet Control (dimming enabled) SXXX - Custom control/sensor TXXX - Custom photocell SC - Shorting Cap Schréder Lighting LLC 1415 West 22nd Street, T Floor Oak Brook, IL 60523 USA T 847-621-5130 www.schreder.com All SmartLume fixtures ship with: • NEMA 7-pin receptacle included (shorting cap optional, must be ordered separately) • 20 kV / 10kA surge protection included • Standard mast-arm lateral entry mounting to 1 1/4” - 2” pipes • Compatible for wireless dimming with LuCo Owlet Control or other wireless NEMA twist-lock devices • 10 year warranty Sample Configuration: SMART2-US-36L146-NW-T3M-SV-BZ-___-___-___-___-___ 1. Specify BASE LUMINAIRE 2. Select OPTIONS BASE LUMINAIRE (recommended flux code configurations) OPTIONS (add codes below to end of part number above) * Dimming Options * D01 - 0-10V DXXX - Custom dimming Other Options * ZZ - Custom cable type AA - Special wattage labeling A6 - Oceanside (3000 hour paint testing) PXXX - Custom photometry CXXX - Custom cables LXXX - Custom labeling FXXX - Custom finish/color OXXX - Other AB Bird spikes S1 Backlight Shield (consult factory) ADDITIONAL FLUX CODE CONFIGURATIONS: SMART2-US, 24 LED SMART2-US, 36 LED SMART3-US, 48 LED SMART3-US, 60 LED 24L081 (24 LEDs, 8.1K lms, 64W) 36L134 (36 LEDs, 13.4K lms, 104W) 48L185 (48 LEDs, 18.5K lms, 148W) 60L267 (60 LEDs, 26.7K lms, 223W) x 24L101 (24 LEDs, 10.1K lms, 85W) 36L168 (36 LEDs, 16.8K lms, 144W) 60L306 (60 LEDs, 30.6K lms, 280W) --x 24L122 (24 LEDs, 12.2K lms, 111W) + Finish Options * RALXXXXM - (Other RAL matte) RALXXXXB - (Other RAL brilliant) RALXXXXT - (Other RAL textured) NOTES: + Configuration not available in HV (347-480V CLI) -- Configuration not available in SV (120-277V CLI) x HV Configurations ship with 277-480V CLI voltage driver standard * Additional cost may apply ^ Lumen output for WW (Warm 3000K) LED configurations is up to 15% less than NW or CW configurations # Luminaire typical power consumption is +/- 5% with HV (347-480V CLI) voltage & EL Class Job Name / Location Fixture Type Configuration NEW!

Upload: others

Post on 05-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ORDERING INFORMATION - Schreder...P7 - LuCo Owlet Control (dimming enabled) SXXX - Custom control/sensor TXXX - Custom photocell SC - Shorting Cap Schréder Lighting LLC 1415 West

SmartLumeORDERING INFORMATION

Luminaire Flux Code Color Temp.(70+ CRI) Optic Voltage & EL Class Finish

SMART1-US 12L041 (12 LEDs, 4.1K lms, 33W) +12L055 (12 LEDs, 5.5K lms, 48W) +

StandardNW (Neutral 4000K)

Optional *WW (Warm 3000K) ^CW (Cool 5700K)

T2M (Type 2 Roadway 5172)T3M (Type 3 Roadway 5171)T3C (Type 3 Local 5173)T4M (Type 4 5174)T5S (Type 5 5175)T5Q (Type VS Square 5242)

StandardSV (120-277V CLI)

Optional *HV (347-480V CLI) #

GY (RAL7040T Grey)BK (RAL9011T Black)WH (RAL9016T White)BZ (RAL8019T Bronze)SMART2-US 24L073 (24 LEDs, 7.3K lms, 56W)

24L093 (24 LEDs, 9.3K lms, 77W) 24L112 (24 LEDs, 11.2K lms, 98W)

36L146 (36 LEDs, 14.6K lms, 117W)36L177 (36 LEDs, 17.7K lms, 155W) +

SMART3-US 48L200 (48 LEDs, 20.0K lms, 166W) 48L214 (48 LEDs, 21.4K lms, 183W)

60L231 (60 LEDs, 23.1K lms, 180W)60L284 (60 LEDs, 28.4K lms, 238W) x

Preliminary data, date of revision: 09/22/2017Copyright © Schréder® Lighting LLC 2016 - Executive Publisher: Fred Kern. 1415 West 22nd Street, T Floor, Oak Brook, IL 60523. The information, descriptions and illustrations herein are of only an indicative nature. Due to advanced developments, we may be required to alter the characteristics of our products without notice. As these may present different characteristics according to the requirements of individual countries, we invite you to consult us.

ANSI/UL 1598/CAN/CSA C22.2 No.250.0-08, 3rd Ed.

Control Options *P7 - LuCo Owlet Control (dimming enabled)SXXX - Custom control/sensorTXXX - Custom photocellSC - Shorting Cap

Schréder Lighting LLC1415 West 22nd Street, T Floor Oak Brook, IL 60523 USAT 847-621-5130www.schreder.com

All SmartLume fixtures ship with:• NEMA 7-pin receptacle included (shorting cap optional, must be ordered separately)• 20 kV / 10kA surge protection included• Standard mast-arm lateral entry mounting to 1 1/4” - 2” pipes• Compatible for wireless dimming with LuCo Owlet Control or other wireless NEMA twist-lock devices• 10 year warranty

Sample Configuration: SMART2-US-36L146-NW-T3M-SV-BZ-___-___-___-___-___1. Specify BASE LUMINAIRE2. Select OPTIONS

BASE LUMINAIRE (recommended flux code configurations)

OPTIONS (add codes below to end of part number above) *

Dimming Options *D01 - 0-10VDXXX - Custom dimming

Other Options *ZZ - Custom cable typeAA - Special wattage labelingA6 - Oceanside (3000 hour paint testing)PXXX - Custom photometry CXXX - Custom cables LXXX - Custom labelingFXXX - Custom finish/colorOXXX - OtherAB – Bird spikesS1 – Backlight Shield (consult factory)

ADDITIONAL FLUX CODE CONFIGURATIONS:SMART2-US, 24 LED SMART2-US, 36 LED SMART3-US, 48 LED SMART3-US, 60 LED 24L081 (24 LEDs, 8.1K lms, 64W) 36L134 (36 LEDs, 13.4K lms, 104W) 48L185 (48 LEDs, 18.5K lms, 148W) 60L267 (60 LEDs, 26.7K lms, 223W) x 24L101 (24 LEDs, 10.1K lms, 85W) 36L168 (36 LEDs, 16.8K lms, 144W) 60L306 (60 LEDs, 30.6K lms, 280W) --x24L122 (24 LEDs, 12.2K lms, 111W) +

Finish Options *RALXXXXM - (Other RAL matte)RALXXXXB - (Other RAL brilliant)RALXXXXT - (Other RAL textured)

NOTES:+ Configuration not available in HV (347-480V CLI)-- Configuration not available in SV (120-277V CLI)x HV Configurations ship with 277-480V CLI voltage driver standard* Additional cost may apply^ Lumen output for WW (Warm 3000K) LED configurations is up to 15% less than NW or CW configurations# Luminaire typical power consumption is +/- 5% with HV (347-480V CLI) voltage & EL Class

Job Name / Location

Fixture Type

Configuration

NEW!

Page 2: ORDERING INFORMATION - Schreder...P7 - LuCo Owlet Control (dimming enabled) SXXX - Custom control/sensor TXXX - Custom photocell SC - Shorting Cap Schréder Lighting LLC 1415 West

Low-profile, budget-friendly outdoor lighting solution that performs in a range of municipal and road applications.

BEST IN CLASS OPTICS New optics designed specifically for SmartLume provide market-leading performance in compliance with IES recommendations for roadway lighting (IES RP-08-14) and parking facilities (IES RP-20-14).

APPLICATIONS• Major and minor roadways• City streets in both downtown and residential environments• Parking lot applications• Municipal parks • Recreation areas

DESIGN OPTIONSSmartLume's adjustable LED optical block design is offered in three scalable sizes to suit the requirements of individual applications. Efficiently replaces HID/HPS fixtures ranging from 50W – 400W to deliver accelerated project ROI.

ECONOMIC BENEFITSSmartLume has been engineered with a superior quality-to-cost ratio. Because of its economical price point, ease of installation in both retrofit or new construction applications, and maintenance savings over the life of an installation, SmartLume offers the fastest ROI in the market for a wide variety of projects.

SMARTLUMESMARTLUME

KEY SPECIFICATIONS - LUMINAIREOptical compartment tightness level: IP 66 (*)

Power compartment tightness level: IP 54 (*)

Impact resistance: IK 10 (**) Nominal voltage: 120 - 277V - 50-60Hz 347 - 480V - 50-60HZL70: 100,000+ hoursCCT: 3000K, 4000K or 5700KTHD: ≤ 20%PF: ≥ 0.90Electrical safety class: Class 1EPA:

SmartLume 1: 0.431 ft2

SmartLume 2: 0.753 ft2

SmartLume 3: 0.786 ft2

Materials: Body: High-pressure die-cast aluminium Lenses: SiliconeColour: RAL 7040T (any other RAL color upon request)

KEY ADVANTAGES• Accelerated return on investment• Easy and fast installation in retrofit or new construction• IP 66 tightness level ensures long-lasting performance • Operating temp range -40°F to 131°F, -40°C to 55°C (*)

• BUG rating: U=0, no up-light• Standard mast-arm mounting: 1 ¼” to 2” pipes (42-60mm) with

inclination from -10° to +5° in steps of 2.5°• 3G rated, ANSI standard C136-31• Surge protection 20kV / 10kA• 7-pin receptacle included (shorting cap optional)• Optional control solutions: photocell and/or Owlet® control

systems (*) according to IEC - EN 60598

(**) according to IEC - EN 62262

SmartLume

Preliminary data, date of revision: 09/22/2017

Copyright © Schréder® S.A. 2017 - Executive Publisher: Fred Kern. 1415 West 22nd Street, T Floor, Oak Brook, IL 60523. The information, descriptions and illustrations herein are of only an indicative nature. Due to advanced developments, we may be required to alter the characteristics of our products without notice. As these may present different characteristics according to the requirements of individual countries, we invite you to consult us.

ANSI/UL 1598/CAN/CSA C22.2 No.250.0-08, 3rd Ed.

Page 3: ORDERING INFORMATION - Schreder...P7 - LuCo Owlet Control (dimming enabled) SXXX - Custom control/sensor TXXX - Custom photocell SC - Shorting Cap Schréder Lighting LLC 1415 West

Prel

imin

ary

data

, dat

e of

rev

isio

n: 0

9/22

/201

7

PHOTOMETRY

SmartLume Size 1 Neutral White (4000K)

SmartLume Size 2 Neutral White (4000K)

SmartLume Size 3 Neutral White (4000K)

Number of LEDs

Typical luminaire

output flux (*)

Typical luminaire

power consumption

(120-277V)

Typical luminaire

power consumption (347-480V)

Number of LEDs

Typical luminaire

output flux (*)

Typical luminaire

power consumption

(120-277V)

Typical luminaire

power consumption (347-480V)

Number of LEDs

Typical luminaire

output flux (*)

Typical luminaire

power consumption

(120-277V)

Typical luminaire

power consumption (347-480V)

124100lm 33W -

24

7300lm 56W 55W

48

18500lm 148W 149W

5500lm 48W - 8100lm 64W 62W 20000lm 166W 165W

(*) The flux is an indicative flux @ tj 25°C based on LED manufacturer’s data. The real flux output of the luminaire depends on environmental conditions (e.g. temperature and pollution) and the optical efficiency of luminaire.

9300lm 77W 74W 21400lm 183W 181W

10100lm 85W 83W

60

23100lm 180W 188W

11200lm 98W 96W 26700lm 223W 227W

12200lm 111W - 28400lm 238W 248W

36

13400lm 104W 108W 30600lm - 280W

14600lm 117W 120W

16800lm 144W 144W

17700lm 155W -

Smar

tLum

e DIMENSIONS AND WEIGHT LL

H1 H2

l

SmartLume 1 SmartLume 2 SmartLume 3 L 19.2” | 487mm 23.9” | 607mm 28.6” | 727mm H1 5.2” | 131mm 5.2” | 131mm 5.2” | 131mm H2 6.4” | 162mm 6.4” | 162mm 6.4” | 162mml 13” | 330mm 13” | 330mm 13” | 330mmWeight 14.3lbs | 6.5kg 16.5lbs | 7.5kg 18.7lbs | 8.5kg

LuminaireT2M

(Type II Roadway 5172)T3M

(Type III Roadway 5171)T3C

(Type III Local 5173)T4M

(Type IV 5174)T5S

(Type VS 5175)T5Q

(Type VS Square 5242)

SMART1-US, 12 LED B1 U0 G1 B1 U0 G1 B1 U0 G1 B1/B2 U0 G1/G2 B3 U0 G1 B3 U0 G1

SMART2-US, 24 LED B2 U0 G2 B2 U0 G2 B2 U0 G2 B2/B3 U0 G2/G3 B3/B4 U0 G2 B3/B4 U0 G2

SMART2-US, 36 LED B3 U0 G3 B3 U0 G3 B3 U0 G3 B3 U0 G3 B4 U0 G2 B4 U0 G2/G3

SMART3-US, 48 LED B3 U0 G3 B3 U0 G3 B3 U0 G3 B3 U0 G3/G4 B4 U0 G2/G3 B4 U0 G2/G3

SMART3-US, 60 LED B3 U0 G3 B3 U0 G3/G4 B3/B4 U0 G3/G4 B3/B4 U0 G3/G4 B4 U0 G3/G4 B4 U0 G3/G4

Page 4: ORDERING INFORMATION - Schreder...P7 - LuCo Owlet Control (dimming enabled) SXXX - Custom control/sensor TXXX - Custom photocell SC - Shorting Cap Schréder Lighting LLC 1415 West

LIGHT DISTRIBUTIONS*

T3M (Type III Roadway 5171)

T2M (Type II Roadway 5172)

T3C (Type III Local 5173)

T4M (Type IV 5174)

T5S (Type VS 5175)

T5Q (Type VS Square 5242)

*48 LED NW distributions shown. lluminance diagrams use a mounting height of 25ft (7.6m).