or 6-41 k 4 p1-t3 · or 6-41 k 4 p1-t3 retroreflective sensor di-soric gmbh & co. kg...

1
206206 © di-soric | Subject to modifications | 19/05/20 | Page 1 (1) OR 6-41 K 4 P1-T3 Retroreflective Sensor di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com TECHNICAL INFORMATION (typ.) +20°C, 24V DC Operating principle Retroreflective sensor Evaluation digital Size 38 x 27 x 15 mm (Dimensions) Design cuboid design Characteristics Integrated polarized filter, Reflector R 46 in delivery Emitted light Red, 630 ... 670 nm, clocked Operating distance 400 ... 4000 mm (R 46), 900 ... 9000 mm (R 84), 1000 ... 10000 mm (R 100x100) Service voltage 10 ... 30 V DC No-load current < 25 mA Sensitivity adjustment potentiometer Referring reflector 100 x 100 mm Switching output pnp, 100 mA, NC Shock-/vibration load 10 ... 55 Hz / 1,0 mm / 30 g Switching frequency 500 Hz Ambient temperature, operation -25 … +60 °C Ambient light immunity 5 kLx Protection class IP 67 Protection degree III, operation on protective low voltage Casing material plastics Material plastic (Window) Connection Connector, M8, 3-poled BN = brown BK = black BU = blue BN BK BU 1 4 3 S pnp Safety instructions The Instruments are not to be used for safety applications, in particular applications in which safety of persons depends on proper operation of the instruments. These instruments shall exclusively be used by qualified personnel. High operating distance Visible red light with small light spot Polarized filter Sensitivity adjustable Small design All-purpose mounting LED indicatior for output state

Upload: others

Post on 19-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OR 6-41 K 4 P1-T3 · OR 6-41 K 4 P1-T3 Retroreflective Sensor di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 -

206206

© di-soric | Subject to modifications | 19/05/20 | Page 1 (1)

OR 6-41 K 4 P1-T3

Retroreflective Sensor

di-soric GmbH & Co. KG Steinbeisstraße 6 DE-73660 Urbach

Fon + 49 (0) 71 81 / 98 79 - 0 Fax + 49 (0) 71 81 / 98 79 - 179 [email protected] www.di-soric.com

TECHNICAL INFORMATION (typ.) +20°C, 24V DC

Operating principle   Retroreflective sensor

Evaluation   digital

Size   38 x 27 x 15 mm (Dimensions)

Design   cuboid design

Characteristics   Integrated polarized filter, Reflector R 46 in delivery

Emitted light   Red, 630 ... 670 nm, clocked

Operating distance   400 ... 4000 mm (R 46), 900 ... 9000 mm (R 84), 1000 ... 10000mm (R 100x100)

Service voltage   10 ... 30 V DC

No-load current   < 25 mA

Sensitivity adjustment   potentiometer

Referring reflector   100 x 100 mm

Switching output   pnp, 100 mA, NC

Shock-/vibration load   10 ... 55 Hz / 1,0 mm / 30 g

Switching frequency   500 Hz

Ambient temperature, operation   -25 … +60 °C

Ambient light immunity   5 kLx

Protection class   IP 67

Protection degree   III, operation on protective low voltage

Casing material   plastics

Material   plastic (Window)

Connection   Connector, M8, 3-poled

BN = brown

BK = black

BU = blue

BN

BK

BU

1

4

3

Spnp

Safety instructionsThe Instruments are not to be used for safety applications, in particularapplications in which safety of persons depends on proper operation of theinstruments.These instruments shall exclusively be used by qualified personnel.

High operating distance

Visible red light with small light spot

Polarized filter

Sensitivity adjustable

Small design

All-purpose mounting

LED indicatior for output state