optronic laboratories inc. ol series 750 automated spectroradiometric measurement system

28
Optronic Laboratories, Optronic Laboratories, Inc. Inc. Optronic Laboratories Inc. Optronic Laboratories Inc. OL Series 750 Automated OL Series 750 Automated Spectroradiometric Spectroradiometric Measurement System Measurement System - PMTs - Indium Antimodide (InSB) - Silicon (Si) - Mercury Cadmium Telluride (HgCdTe) - Germanium (Ge) - Pyroelectric - Indium Gallium Arsenide (InGaAs) - CCD - Lead Sulphide (PbS) - Cameras - Lead Selenide (PbSe) - Radiometers and Photometers An Advanced Turnkey System for An Advanced Turnkey System for Automated Detector Response Automated Detector Response Measurements Measurements

Upload: harmon

Post on 23-Feb-2016

119 views

Category:

Documents


0 download

DESCRIPTION

Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System . An Advanced Turnkey System for Automated Detector Response Measurements. - PMTs- Indium Antimodide (InSB) - Silicon (Si)- Mercury Cadmium Telluride (HgCdTe) - Germanium (Ge)- Pyroelectric - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Optronic Laboratories Inc.Optronic Laboratories Inc. OL Series 750 Automated OL Series 750 Automated

SpectroradiometricSpectroradiometric Measurement System Measurement System

- PMTs - Indium Antimodide (InSB)- Silicon (Si) - Mercury Cadmium Telluride (HgCdTe)- Germanium (Ge) - Pyroelectric- Indium Gallium Arsenide (InGaAs) - CCD- Lead Sulphide (PbS) - Cameras- Lead Selenide (PbSe) - Radiometers and Photometers

An Advanced Turnkey System for An Advanced Turnkey System for Automated Detector Response Automated Detector Response

MeasurementsMeasurements

Page 2: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

About Optronic About Optronic Laboratories, Inc.Laboratories, Inc.

Optronic Laboratories, Inc. was established in 1970 by two eminent researchers at NIST (then NBS). Facilities were modeled after NIST, and Optronic

Laboratories, Inc. achieved a worldwide reputation for excellence in light measurement and calibration.

Continuing to work closely with NIST, the development of new instruments and techniques at Optronic Laboratories, Inc. constantly improves the

accuracy and precision of light measurement.

Page 3: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

About Optronic About Optronic Laboratories, Inc.Laboratories, Inc.

In 1998, Optronic Laboratories, Inc. moved into its new 25,000 square foot purpose-built

facility, consolidating and expanding production, R & D and calibration facilities

Page 4: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Spectroradiometers: laboratory & field portable

Broad-band radiometers & photometers: DC, AC, pulsed or modulated sources

Sphere systems: from 1” to 76” diameter as standard

NIST-traceable calibration sources, materials & detectors: from 200 nm to 30,000 nm

Measurement services: sources, materials & detectors

Customization/new product development

Training, consultation & advice

About Optronic About Optronic Laboratories, Inc.Laboratories, Inc.

Optronic Laboratories’ instruments & services include:

Page 5: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The heart of any spectroradiometric system is the monochromator, but…

It must give the right bandpasses – not too large and not too small

It must give high spectral purity (low stray light) so only the wavelength of interest is detected

Page 6: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Available in single and double (shown) versions

F/4 optics for high throughput

Very low stray light Numerous special

features for most accurate results

Page 7: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Large range of gratings available

Optimised for high efficiency

Optimised for wide wavelength range

Optimised for high resolutionTri-grating mounts change

gratings automatically

Page 8: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Range of Plug-in input accessories

Choppers (shown) for IR detectors

Automatic control of chopper speed and “open” position stop

Filter-wheel for input attenuation or filteringVersatile plug-in chopper or

filter wheel input accessories

Page 9: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Fully automated 11 position blocking-filter wheel

Includes SHUT position for dark current readings

Optimised filters for widest wavelength rangeBlocking-filter wheel

changes filters automatically

Page 10: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Blocking filters:how they work

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Gratings diffract light at different angles depending on wavelength

400nm will also diffract at the same angle as 800nm (since 2 x 400 = 800)

A blocking filter removes the 400nm so just 800nm is left

400nm +

800nm400nm400nm

800nm

Blocking filter

grating

Page 11: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Light passes into the monochromator through the entrance slit, then onto the first collimating mirror.

Page 12: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

Collimated (parallel) light is directed onto the grating.

Page 13: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The grating diffracts the light, sending each wavelength off at a different angle.The desired wavelength is collected by the first focussing mirror….

Page 14: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

…which focuses it at the middle slit.A second collimating mirror collects this beam…

Page 15: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

…and collimates it onto a second grating.Since the second grating is linked to the first, they are at the same angle and hence the same wavelength.

Page 16: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

This second grating acts like the first, but the spectral purity is increased by many decades.

Page 17: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 750 The OL Series 750 MonochromatorsMonochromators

The pure monochromatic light, at the wavelength desired, is then focussed onto the exit slit and emerges from the monochromator

Page 18: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

Single and double lamp versions

UV lamp 200nm to 400nm

Tungsten lamp 250nm to 2500nm

Glowbar 1000nm to

30000nm

Page 19: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

Optics match the OL Series 750 Monochromators

Easy switching from one source …

Page 20: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL Series 740-20 The OL Series 740-20 Light SourcesLight Sources

…to the other

Optics match the OL series 750 monochromators

Easy switching from one source …

Fully automated switching available

Page 21: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750 + OL 740-The OL 750 + OL 740-2020

200 to 30,000 nm coverage

monochromatic light prevents sample heating

Suits a very wide range of standard OL accessories

Suits many existing and future applications

Page 22: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Detector Spectral Detector Spectral ResponseResponse

In order to characterize their performance in a particular applications, single detectors, array detectors and assemblies often need spectral response to be known

For example, photopic detectors can be analysed for V() matching

Page 23: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Detector Spectral Detector Spectral ResponseResponse

Measurements are generally consistent with detector use, and may require a large collimated beam, a small spot, a diffuse source or other geometry

Optronic Laboratories, Inc. manufactures a wide range of accessories for most detector measurement requirements, including quantum efficiency

Page 24: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

Detector Spectral Detector Spectral ResponseResponse

Optronic Laboratories, Inc. provides standard detectors, traceable to NIST and other National Laboratories

To illustrate a detector spectral response system, we will use the OL 750-10C All Mirror Collimator

Page 25: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750-10CThe OL 750-10C

2 inch diameter beam

Excellent beam uniformity

Constant collimation at all wavelengths

Page 26: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750 + OL 740-The OL 750 + OL 740-20 + OL 750-10C20 + OL 750-10C

If we put these together…

Page 27: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

The OL 750 + OL 740-The OL 750 + OL 740-20 + OL 750-10C20 + OL 750-10C

We have a complete system for detector response

First we calibrate with the standard

detector

Then we measure the test detector

Page 28: Optronic Laboratories Inc.  OL Series 750 Automated Spectroradiometric  Measurement System

Optronic Laboratories, Inc.Optronic Laboratories, Inc.

More InformationMore Information

The system illustrated represents one of the applications of the OL 750 Series ASMS, others include:

Source Spectral Analysis (Irradiance and Radiance) Transmission (Diffuse and Linear) Reflectance (Diffuse and Specular)

Visit our website at www.olinet.com