optoacoplador cosmo k1010
TRANSCRIPT
PRODUCT SPECIFICATION DATE:06/04/2012
NO.60P00075cosmo ELECTRONICS CORPORATION
Photocoupler:
K1010 SHEET 1 OF 6REV.
6
High Reliability Photocoupler
Features
1. Current transfer ratio ( CTR:Min. 50% at IF=5mA VCE=5V )
2. High isolation voltage between input and output ( Viso:5000Vrms )
3. Compact dual-in-line package. 4. Pb free and RoHS compliant. 5. Agency Approvals
• UL UL1577 / CUL C22.2 No.1 & NTC No.5, File No. E169586 • VDE EN60747, File No.101347 • FIMKO EN60065, File No.FI23149 • FIMKO EN60950, File No.FI24584 • SEMKO EN60065, File No.1016484 • SEMKO EN60950, File No.1016433 • CQC GB4943 / GB8898, File No.CQC10001049555/CQC08001023986
Application:
1. Registers, copies, automatic vending machines. 2. System appliances, measuring instruments. 3. Computer terminals, programmable controllers. 4. Communications, telephone, etc. 5. Electric home appliances, such as oil fan heaters, Microwave
Oven, Washer, Refrigerator, Air conditioner, etc. 6. Medical instruments, physical and chemical equipment. 7. Signal transmission between circuits of different potentials
and impedances. 8. Facsimile equipment, Audio, Video. 9. Switching power supply, Laser beam printer.
PRODUCT SPECIFICATION DATE:06/04/2012
NO.60P00075cosmo ELECTRONICS CORPORATION
Photocoupler:
K1010 SHEET 2 OF 6REV.
6
Outside Dimension:Unit ( mm )
0.40
3.00
2.70
13.00°
0.25
13.00°
1.200.50
2.54
7.62
6.503.
50
4.60
cosmo1010817XXX
Data Code
CTR Rank
TOLERANCE:±0.2mm
Schematic:Top View
1
2
4
3
1. Anode 2. Cathode 3. Emitter 4. Collector
PRODUCT SPECIFICATION DATE:06/04/2012
NO.60P00075cosmo ELECTRONICS CORPORATION
Photocoupler:
K1010 SHEET 3 OF 6REV.
6
Absolute Maximum Ratings
Parameter Symbol Rating Unit Forward current IF 50 mA Peak forward current IFM 1 A Reverse voltage VR 6 V
Input
Power dissipation PD 70 mW
Collector-emitter voltage VCEO 80 V Emitter-collector voltage VECO 6 V Collector current IC 50 mA Collector power dissipation PC 150 mW
Output
Junction temperature Tj 125 ℃
Total power dissipation Ptot 200 mW Isolation voltage 1 minute Viso 5000 Vrms Operating temperature Topr -55 to +115 ℃
Storage temperature Tstg -55 to +125 ℃
Soldering temperature 10 second Tsol 260 ℃
Electro-optical Characteristics
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Forward voltage VF IF=20mA - 1.2 1.4 V
Peak forward voltage VFM IFM=0.5A - - 3.0 V
Reverse current IR VR=4V - - 10 μA Input
Terminal capacitance Ct V=0, f=1KHz - 30 - pF
Output Collector dark current ICEO VCE=20V - - 0.1 μA
Current transfer ratio CTR IF=5mA, VCE=5V 50 - 600 %
Collector-emitter saturation VCE(sat) IF=20mA, IC=1mA - 0.1 0.2 V
Isolation resistance Riso DC500V 5x1010 1011 - Ω
Floating capacitance Cf V=0, f=1MHz - 0.6 1.0 pF
Cut-off frequency fC VCC=5V, IC=2mA, RL=100Ω - 80 - KHz
Response time ( Rise ) tr - 4 18 μs
Transfer charac- teristics
Response time ( Fall ) tf VCE=2V, IC=2mA, RL=100Ω
- 3 18 μs
PRODUCT SPECIFICATION DATE:06/04/2012
NO.60P00075cosmo ELECTRONICS CORPORATION
Photocoupler:
K1010 SHEET 4 OF 6REV.
6
Fig.1 Current Transfer Ratio vs. Forward Current
Cur
rent
tran
sfer
ratio
C
TR (
% )
1 2 5 20 500
50
100
150
200
250
300
350
400
450
500
Ta=25℃
0 10
VCE=5V
Classification table of current transfer ratio is shown below.
Model No. CTR ( % ) K10101A 80 ~ 160 K10101B 130 ~ 260 K10101C 200 ~ 400 K10101D 300 ~ 600 K10101E 50 ~ 600
Forward current IF (mA)
Fig.2 Collector Power Dissipation vs. Ambient Temperature Fig.3 Collector Dark Current
vs. Ambient Temperature
Col
lect
or P
ower
Dis
sipa
tion
P C (
mW
)
250-55
50
0
100
1257550
200
150
250
115
Col
lect
or D
ark
Cur
rent
I C
EO (
A )
-810
0 2510
-1110
-10
-910
Vce=20V
10-7
10-6
10-5
7550 115-55
Ambient Temperature Ta (℃) Ambient Temperature Ta (℃)
Fig.4 Forward Current vs. Ambient Temperature Fig.5 Forward Current vs.
Forward Voltage
Forw
ard
Cur
rent
I F (
mA
) 60
10
-550
20
0 25
30
40
50
50 75 115 125
Forw
ard
Cur
rent
I F (
mA
)
1.8
-25°
1.61.21.0 1.4
Ta=75°
50°C
C
2.42.0 2.2
C
C25°
C0°
500
20
1
2
510
10050
200
Ambient Temperature Ta (℃) Forward Voltage VF (V)
PRODUCT SPECIFICATION DATE:06/04/2012
NO.60P00075cosmo ELECTRONICS CORPORATION
Photocoupler:
K1010 SHEET 5 OF 6REV.
6
Fig.6 Collector Current vs. Collector-Emitter Voltage Fig.7 Relative Current Transfer Ratio
vs. Ambient Temperature
Col
lect
or C
urre
nt I C
(mA
)
00 1
5
10
2 3 4 65 7
5mA
98
20mA
20
15
25
30Ta=25°
10mA
CIF=30mA
Rel
ativ
e C
urre
nt T
rans
fer
Rat
io (
% )
-550
-25
50
25 50 11575
IF=5mAVCE=5V
150
100
0
Collector-Emitter Voltage VCE (V) Ambient Temperature Ta (℃)
Fig.8 Collector-Emitter Saturation Voltage vs. Ambient Temperature Fig.9 Collector-Emitter Saturation
Voltage vs. Forward Current
Col
lect
or-E
mitt
er S
atur
atio
n Vo
ltage
VC
E (
V )
00 5025 75 115
Ic=1mA
0.02
0.04
0.06
0.10
0.08
0.12
0.16
0.14IF=20mA
-55
Col
lect
or-E
mitt
er S
atur
atio
n Vo
ltage
VC
E (
V )
50 10
CTa=25°
Ic=7m A
Ic=5m A
Ic=3m A
Ic=1m A
Ic=0.5m A
0
1
3
2
5
4
6
7
Ambient Temperature Ta (℃) Forward Current IF (mA)
Fig.10 Response Time vs. Load Resistance Fig.11 Response Time vs.
Load Resistance
Res
pons
e R
ise
Tim
e ( u
s )
1 010 .1
tr
0 .5
0 .20 .1
1 2
5
1 0
2 0
1 0 0
5 0 Ic = 2 m AV c e = 2 V
CT a = 2 5 °
Res
pons
e Fa
ll Ti
me
( us
)
1 00 .1 10 .10 .2
1
0 .5
5
2
2 0
1 0
Ic = 2 m AV c e = 2 V
1 0 0
5 0C
tfT a = 2 5 °
Load Resistance RL (KΩ) Load Resistance RL (KΩ)
PRODUCT SPECIFICATION DATE:06/04/2012
NO.60P00075cosmo ELECTRONICS CORPORATION
Photocoupler:
K1010 SHEET 6 OF 6REV.
6
Notice
The information contained in this document is intended to be a general product description and is subject to change without notice. Please contact cosmo in order to obtain the latest device data sheets before using any cosmo device. cosmo does not assume any responsibility for use of any circuitry described. No circuit patent licenses are implied. This publication is the property of cosmo. No part of this publication may be reproduced or copied in any form or by any means, or transferred to any third party without the prior written consent of cosmo Electronics Corporation. The devices listed in this document are designed for general applications only in electronic equipment. No devices shall be deployed which require higher level of reliability such as:
– Medical and other life support equipments. – Space application. – Telecommunication equipment ( trunk lines ). – Nuclear power control equipment. Unless it received prior written approval from cosmo. cosmo takes no responsibility for damages arise form the
improper usage of our device. Please contact cosmo for further information regarding the above notices.