optimize refrigeration efficiency - reduce … coolsmarttm refrigeration synergy. optimize...

4
www.coolsmart.net CoolSmart TM Refrigeration Synergy. Optimize Refrigeration Efficiency - Reduce Operating Costs CoolSmart TM is a patent-pending solution that integrates with an existing refrigeration system to improve operational efficiency and reduce costs. The Concept Refrigeration vapor compressors alone create the pressure difference that moves refrigerant vapor and liquid through DX cooling systems in supermarkets and other facilities. CoolSmart TM adds pressure - but no heat - to the liquid refrigerant. Adding pressure to the liquid refrigerant increases expansion valve capacity. Food cases and other cooling loads are thereby refrigerated more efficiently and at a reduced energy cost. The refrigeration vapor compressors’ workload, run time and electrical energy consumption are reduced; vapor compressors use the most electrical energy in a DX refrigeration system. Consider… Using vapor compressors to move liquid refrigerant is like using a fan to push water through pipes. Not energy efficient. Not CoolSmart TM . CoolSmart TM allows equipment to be used for its intended purpose: Allow vapor compressors to only move vapor refrigerant. Use a liquid pump to move liquid refrigerant. CoolSmart TM Refrigeration Synergy.

Upload: truongnhu

Post on 07-May-2018

224 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Optimize Refrigeration Efficiency - Reduce … CoolSmartTM Refrigeration Synergy. Optimize Refrigeration Efficiency - Reduce Operating Costs CoolSmartTM is a patent-pending solution

www.coolsmart.net

CoolSmartTM Refrigeration Synergy.

Optimize Refrigeration Efficiency - Reduce Operating Costs

CoolSmartTM is a patent-pending solution that integrates with an existing refrigeration system to improve operational efficiency and reduce costs. The Concept Refrigeration vapor compressors alone create the pressure difference that moves refrigerant vapor and liquid through DX cooling systems in supermarkets and other facilities. CoolSmartTM adds pressure - but no heat - to the liquid refrigerant. Adding pressure to the liquid refrigerant increases expansion valve capacity. Food cases and other cooling loads are thereby refrigerated more efficiently and at a reduced energy cost. The refrigeration vapor compressors’ workload, run time and electrical energy consumption are reduced; vapor compressors use the most electrical energy in a DX refrigeration system.

Consider…

Using vapor compressors to move liquid refrigerant is like using a fan to push water through pipes.

Not energy efficient.

Not CoolSmartTM.

CoolSmartTM allows equipment to be used for its intended purpose:

Allow vapor compressors to only move vapor refrigerant.

Use a liquid pump to move liquid refrigerant.

CoolSmartTM Refrigeration Synergy.

Page 2: Optimize Refrigeration Efficiency - Reduce … CoolSmartTM Refrigeration Synergy. Optimize Refrigeration Efficiency - Reduce Operating Costs CoolSmartTM is a patent-pending solution

www.coolsmart.net

CoolSmartTM Refrigeration Synergy.

Operation With CoolSmart™ in operation, the refrigeration system is effectively divided into liquid and vapor circuits.

   

CoolSmart™ utilizes an energy efficient liquid pump controlled by a variable frequency drive to add the optimal amount of pressure to the liquid refrigerant delivered to expansion valves. Compressors operate less, expansion valve capacities increase, and energy consumption is reduced. Reliable Operation for All Refrigeration Demand Conditions CoolSmartTM insures that pressurized liquid refrigerant is available under all refrigeration demands year-round, and liquid refrigerant pressure is maintained for the desired food case temperatures. The CoolSmartTM design has eliminated the operational issues and high maintenance requirements of previous liquid pump systems.

Expansion Valve

Liquid Refrigerant to Expansion Valve

Refrigeration Rack Compressors

Bulb

Liquid Refrigerant from Condenser

Suction Vapor

Discharge Vapor

Check Valve

Check Valve

Vapor Circuit Liquid Circuit

Refrigerant Storage Tank

Liquid Venturi Eductor

High pressure connection Suction

Port

Discharge Port

Check Valve

���������

Condenser

Evaporator

Liquid Refrigerant Overflow

Pressurized Liquid Refrigerant

Page 3: Optimize Refrigeration Efficiency - Reduce … CoolSmartTM Refrigeration Synergy. Optimize Refrigeration Efficiency - Reduce Operating Costs CoolSmartTM is a patent-pending solution

www.coolsmart.net

CoolSmartTM Refrigeration Synergy.

Benefits Summary CoolSmart™ field operation demonstrates the following benefits:

• Energy cost reduction on compressor rack • Operation at reduced head pressure and temperatures • Continuous 24x7 operation without pump cavitation • Increased refrigeration capacity • Improved food case temperature stability • Reduced refrigerant leakage and system charging • High Reliability: 10,000+ hours of operation (and counting)

without a failure • Reduced maintenance • Ease of integration with an existing refrigeration system • Bypass to conventional refrigeration system operation

when not in operation • Footprint of less than 20 square inches

CoolSmart™ industry leading OEM partners include Teikoku USA / Chempump, Yaskawa, and Westermeyer Industries.

Energy Savings and Return on Investment A CoolSmart™ financial analysis that includes local energy rates, refrigeration rack loads, operating conditions, and seasonal temperatures will estimate cost savings potential. CoolSmart™ is approved for energy efficiency rebates and incentives in certain regions.

Contact us for more information.

CoolSmartTM 259 Drum Point Road

Brick, NJ 08723 (732) 451 9100

[email protected]

Page 4: Optimize Refrigeration Efficiency - Reduce … CoolSmartTM Refrigeration Synergy. Optimize Refrigeration Efficiency - Reduce Operating Costs CoolSmartTM is a patent-pending solution

www.coolsmart.net

CoolSmartTM Refrigeration Synergy.

259 Drum Point Road Brick, NJ 08723 (732) 451 9100

[email protected]

CoolSmartTM Refrigeration Synergy.