operator’s manual idealarc ac1200 - lincoln electric · pdf fileidealarc ® ac1200...

25
IDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345) IM10119 | Issue Date 12-Oct © Lincoln Global, Inc. All Rights Reserved. For use with machines having Code Numbers: 11869 Register your machine: www.lincolnelectric.com/register Authorized Service and Distributor Locator: www.lincolnelectric.com/locator

Upload: phamdan

Post on 10-Mar-2018

223 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

IDEALARC ® AC1200

Operator’s Manual

Save for future reference

Date Purchased

Code: (ex: 10859)

Serial: (ex: U1060512345)

IM10119 | Issue D ate 12-Oct

© Lincoln Global, Inc. All Rights Reserved.

For use with machines having Code Numbers:

11869

Register your machine: www.lincolnelectric.com/register

Authorized Service and Distributor Locator: www.lincolnelectric.com/locator

Page 2: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

THANK YOU FOR SELECTING A QUALITY PRODUCT BY LINCOLN ELEC TRIC.

PLEASE EXAMINE CARTON AND EQUIPMENT FORDAMAGE IMMEDIATELY

When this equipment is shipped, title passes to the purchaserupon receipt by the carrier. Consequently, claims for materialdamaged in shipment must be made by the purchaser against thetransportation company at the time the shipment is received.

SAFETY DEPENDS ON YOU

Lincoln arc welding and cutting equipment is designed and builtwith safety in mind. However, your overall safety can be increasedby proper installation ... and thoughtful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETYPRECAUTIONS CONTAINED THROUGHOUT. And, most importantly,think before you act and be careful.

This statement appears where the information must be followedexactly to avoid serious personal injury or loss of life.

This statement appears where the information must be followedto avoid minor personal injury or damage to this equipment.

KEEP YOUR HEAD OUT OF THE FUMES.

DON’T get too close to the arc.Use corrective lenses if necessaryto stay a reasonable distanceaway from the arc.

READ and obey the Safety DataSheet (SDS) and the warning labelthat appears on all containers ofwelding materials.

USE ENOUGH VENTILATION orexhaust at the arc, or both, tokeep the fumes and gases from your breathing zone and the general area.

IN A LARGE ROOM OR OUTDOORS, natural ventilation may beadequate if you keep your head out of the fumes (See below).

USE NATURAL DRAFTS or fans to keep the fumes away from your face.

If you de velop unusual symptoms, see your supervisor. Perhaps the welding atmosphere and ventilation system should be checked.

WEAR CORRECT EYE, EAR & BODY PROTECTION

PROTECT your eyes and face with welding helmetproperly fitted and with proper grade of filter plate(See ANSI Z49.1).

PROTECT your body from welding spatter and arcflash with protective clothing including woolenclothing, flame-proof apron and gloves, leatherleggings, and high boots.

PROTECT others from splatter, flash, and glarewith protective screens or barriers.

IN SOME AREAS, protection from noise may be appropriate.

BE SURE protective equipment is in good condition.

Also, wear safety glasses in work areaAT ALL TIMES.

SPECIAL SITUATIONSDO NOT WELD OR CUT containers or materials which previouslyhad been in contact with hazardous substances unless they areproperly cleaned. This is extremely dangerous.

DO NOT WELD OR CUT painted or plated parts unless specialprecautions with ventilation have been taken. They can releasehighly toxic fumes or gases.

Additional precautionary measuresPROTECT compressed gas cylinders from excessive heat,mechanical shocks, and arcs; fasten cylinders so they cannot fall.

BE SURE cylinders are never grounded or part of an electrical circuit.

REMOVE all potential fire hazards from welding area.

ALWAYS HAVE FIRE FIGHTING EQUIPMENT READY FORIMMEDIATE USE AND KNOW HOW TO USE IT.

WARNING

CAUTION

Safety 01 of 04 - 06/15/2016

Page 3: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

SECTION A:WARNINGS

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel EnginesDiesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and otherreproductive harm.

Gasoline EnginesThe engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or otherreproductive harm.

ARC WELDING CAN BE HAZARDOUS. PROTECTYOURSELF AND OTHERS FROM POSSIBLE SERIOUSINJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITHTHEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. Foradditional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION,MAINTENANCE AND REPAIR PROCEDURES AREPERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE POWEREDEQUIPMENT.

1.a. Turn the engine off before troubleshootingand maintenance work unless themaintenance work requires it to be running.

1.b. Operate engines in open, well-ventilatedareas or vent the engine exhaust fumes outdoors.

1.c. Do not add the fuel near an open flamewelding arc or when the engine is running.Stop the engine and allow it to cool beforerefueling to prevent spilled fuel fromvaporizing on contact with hot engine partsand igniting. Do not spill fuel when fillingtank. If fuel is spilled, wipe it up and do not start engine untilfumes have been eliminated.

1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating orrepairing equipment.

1.e. In some cases it may be necessary to remove safety guards toperform required maintenance. Remove guards only whennecessary and replace them when the maintenance requiringtheir removal is complete. Always use the greatest care whenworking near moving parts.

1.f. Do not put your hands near the engine fan. Do not attempt tooverride the governor or idler by pushing on the throttle controlrods while the engine is running.

1.g. To prevent accidentally starting gasoline engines while turningthe engine or welding generator during maintenance work,disconnect the spark plug wires, distributor cap or magneto wireas appropriate.

1.h. To avoid scalding, do not remove the radiatorpressure cap when the engine is hot.

ELECTRIC ANDMAGNETIC FIELDS MAYBE DANGEROUS

2.a. Electric current flowing through any conductorcauses localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physicianbefore welding.

2.c. Exposure to EMF fields in welding may have other health effectswhich are now not known.

2.d. All welders should use the following procedures in order tominimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Securethem with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and workcables. If the electrode cable is on your right side, thework cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as pos-sible to the area being welded.

2.d.5. Do not work next to welding power source.

SAFETY

Safety 02 of 04 - 06/15/2016

Page 4: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

ELECTRIC SHOCK CAN KILL.

3.a. The electrode and work (or ground) circuits areelectrically “hot” when the welder is on. Donot touch these “hot” parts with your bare skin or wet clothing.Wear dry, hole-free gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation.Make certain the insulation is large enough to cover your full areaof physical contact with work and ground.

In addition to the normal safety precautions, ifwelding must be performed under electricallyhazardous conditions (in damp locations or whilewearing wet clothing; on metal structures such asfloors, gratings or scaffolds; when in crampedpositions such as sitting, kneeling or lying, if thereis a high risk of unavoidable or accidental contactwith the workpiece or ground) use the followingequipment:

• Semiautomatic DC Constant Voltage (Wire) Welder.

• DC Manual (Stick) Welder.

• AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode,electrode reel, welding head, nozzle or semiautomatic weldinggun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electricalconnection with the metal being welded. The connection shouldbe as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical (earth)ground.

3.f. Maintain the electrode holder, work clamp, welding cable andwelding machine in good, safe operating condition. Replacedamaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts of electrodeholders connected to two welders because voltage between thetwo can be the total of the open circuit voltage of bothwelders.

3.i. When working above floor level, use a safety belt to protectyourself from a fall should you get a shock.

3.j. Also see It ems 6.c. and 8.

ARC RAYS CAN BURN.

4.a. Use a shield with the proper filter and cover plates to protect youreyes from sparks and the rays of the arc when welding orobserving open arc welding. Headshield and filter lens shouldconform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistant materialto protect your skin and that of your helpers from the arc rays.

4.c. Protect other nearby personnel with suitable, non-flammablescreening and/or warn them not to watch the arc nor exposethemselves to the arc rays or to hot spatter or metal.

FUMES AND GASESCAN BE DANGEROUS.

5.a. Welding may produce fumes and gaseshazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enoughventilation and/or exhaust at the arc to keep fumes and gasesaway from the breathing zone. When welding hardfacing(see instructions on container or SDS) or on leador cadmium plated steel and other metals orcoatings which produce highly toxic fumes, keepexposure as low as possible and within applicableOSHA PEL and ACGIH TLV limits using localexhaust or mechanical ventilation unless exposureassessments indicate otherwise. In confinedspaces or in some circumstances, outdoors, arespirator may also be required. Additionalprecautions are also required when welding on galvanized steel.

5. b. The operation of welding fume control equipment is affected byvarious factors including proper use and positioning of theequipment, maintenance of the equipment and the specificwelding procedure and application involved. Worker exposurelevel should be checked upon installation and periodicallythereafter to be certain it is within applicable OSHA PEL andACGIH TLV limits.

5.c. Do not weld in locations near chlorinated hydrocarbon vaporscoming from degreasing, cleaning or spraying operations. Theheat and rays of the arc can react with solvent vapors to formphosgene, a highly toxic gas, and other irritating products.

5.d. Shielding gases used for arc welding can displace air and causeinjury or death. Always use enough ventilation, especially inconfined areas, to insure breathing air is safe.

5.e. Read and understand the manufacturer’s instructions for thisequipment and the consumables to be used, including theSafety Data Sheet (SDS) and follow your employer’s safetypractices. SDS forms are available from your weldingdistributor or from the manufacturer.

5.f. Also see item 1.b.

SAFETY

Safety 03 of 04 - 06/15/2016

Page 5: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

WELDING AND CUTTINGSPARKS CAN CAUSEFIRE OR EXPLOSION.

6.a. Remove fire hazards from the welding area. Ifthis is not possible, cover them to prevent the welding sparksfrom starting a fire. Remember that welding sparks and hotmaterials from welding can easily go through small cracks andopenings to adjacent areas. Avoid welding near hydraulic lines.Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, specialprecautions should be used to prevent hazardous situations.Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1)and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit istouching the work or ground. Accidental contact can causeoverheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until theproper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside.They can cause an explosion even though they have been“cleaned”. For information, purchase “Recommended SafePractices for the Preparation for Welding and Cutting ofContainers and Piping That Have Held Hazardous Substances”,AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting orwelding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil freeprotective garments such as leather gloves, heavy shirt, cufflesstrousers, high shoes and a cap over your hair. Wear ear plugswhen welding out of position or in confined places. Always wearsafety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding areaas practical. Work cables connected to the building framework orother locations away from the welding area increase thepossibility of the welding current passing through lifting chains,crane cables or other alternate circuits. This can create firehazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

6.I. Read and follow NFPA 51B “Standard for Fire Prevention DuringWelding, Cutting and Other Hot Work”, available from NFPA, 1Batterymarch Park, PO box 9101, Quincy, MA 022690-9101.

6.j. Do not use a welding power source for pipe thawing.

CYLINDER MAY EXPLODE IFDAMAGED.

7.a. Use only compressed gas cylinders containingthe correct shielding gas for the process usedand properly operating regulators designed forthe gas and pressure used. All hoses, fittings,etc. should be suitable for the application andmaintained in good condition.

7.b. Always keep cylinders in an upright position securely chained toan undercarriage or fixed support.

7.c. Cylinders should be located:

• Away from areas where they may be struck or subjectedto physical damage.

• A safe distance from arc welding or cutting operationsand any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any otherelectrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outletwhen opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tightexcept when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders,associated equipment, and CGA publication P-l, “Precautions forSafe Handling of Compressed Gases in Cylinders,” available fromthe Compressed Gas Association, 14501 George Carter WayChantilly, VA 20151.

FOR ELECTRICALLYPOWERED EQUIPMENT.

8.a. Turn off input power using the disconnectswitch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National ElectricalCode, all local codes and the manufacturer’s recommendations.

8.c. Ground the equipment in accordance with the U.S. NationalElectrical Code and the manufacturer’s recommendations.

Refer tohttp://www.lincolnelectric.com/safetyfor additional safety information.

SAFETY

Safety 04 of 04 - 06/15/2016

Page 6: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

ivSAFETYiv

PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parraissent dans cemanuel aussi bien que les précautions de sûreté générales suiv-antes:

Sûreté Pour Soudage A LʼArc1. Protegez-vous contre la secousse électrique:

a. Les circuits à lʼélectrode et à la piéce sont sous tensionquand la machine à souder est en marche. Eviter toujourstout contact entre les parties sous tension et la peau nueou les vétements mouillés. Porter des gants secs et sanstrous pour isoler les mains.

b. Faire trés attention de bien sʼisoler de la masse quand onsoude dans des endroits humides, ou sur un planchermetallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grandepartie du corps peut être en contact avec la masse.

c. Maintenir le porte-électrode, la pince de masse, le câblede soudage et la machine à souder en bon et sûr étatdefonctionnement.

d.Ne jamais plonger le porte-électrode dans lʼeau pour lerefroidir.

e. Ne jamais toucher simultanément les parties sous tensiondes porte-électrodes connectés à deux machines à souderparce que la tension entre les deux pinces peut être letotal de la tension à vide des deux machines.

f. Si on utilise la machine à souder comme une source decourant pour soudage semi-automatique, ces precautionspour le porte-électrode sʼapplicuent aussi au pistolet desoudage.

2. Dans le cas de travail au dessus du niveau du sol, se protégercontre les chutes dans le cas ou on recoit un choc. Ne jamaisenrouler le câble-électrode autour de nʼimporte quelle partiedu corps.

3. Un coup dʼarc peut être plus sévère quʼun coup de soliel,donc:

a. Utiliser un bon masque avec un verre filtrant appropriéainsi quʼun verre blanc afin de se protéger les yeux du ray-onnement de lʼarc et des projections quand on soude ouquand on regarde lʼarc.

b. Porter des vêtements convenables afin de protéger lapeau de soudeur et des aides contre le rayonnement delʻarc.

c. Protéger lʼautre personnel travaillant à proximité ausoudage à lʼaide dʼécrans appropriés et non-inflammables.

4. Des gouttes de laitier en fusion sont émises de lʼarc desoudage. Se protéger avec des vêtements de protection libresde lʼhuile, tels que les gants en cuir, chemise épaisse, pan-talons sans revers, et chaussures montantes.

5. Toujours porter des lunettes de sécurité dans la zone desoudage. Utiliser des lunettes avec écrans lateraux dans leszones où lʼon pique le laitier.

6. Eloigner les matériaux inflammables ou les recouvrir afin deprévenir tout risque dʼincendie dû aux étincelles.

7. Quand on ne soude pas, poser la pince à une endroit isolé dela masse. Un court-circuit accidental peut provoquer unéchauffement et un risque dʼincendie.

8. Sʼassurer que la masse est connectée le plus prés possiblede la zone de travail quʼil est pratique de le faire. Si on placela masse sur la charpente de la construction ou dʼautresendroits éloignés de la zone de travail, on augmente le risquede voir passer le courant de soudage par les chaines de lev-age, câbles de grue, ou autres circuits. Cela peut provoquerdes risques dʼincendie ou dʼechauffement des chaines et descâbles jusquʼà ce quʼils se rompent.

9. Assurer une ventilation suffisante dans la zone de soudage.Ceci est particuliérement important pour le soudage de tôlesgalvanisées plombées, ou cadmiées ou tout autre métal quiproduit des fumeés toxiques.

10. Ne pas souder en présence de vapeurs de chlore provenantdʼopérations de dégraissage, nettoyage ou pistolage. Lachaleur ou les rayons de lʼarc peuvent réagir avec les vapeursdu solvant pour produire du phosgéne (gas fortement toxique)ou autres produits irritants.

11. Pour obtenir de plus amples renseignements sur la sûreté,voir le code “Code for safety in welding and cutting” CSAStandard W 117.2-1974.

PRÉCAUTIONS DE SÛRETÉ POURLES MACHINES À SOUDER ÀTRANSFORMATEUR ET ÀREDRESSEUR

1. Relier à la terre le chassis du poste conformement au code delʼélectricité et aux recommendations du fabricant. Le dispositifde montage ou la piece à souder doit être branché à unebonne mise à la terre.

2. Autant que possible, Iʼinstallation et lʼentretien du poste seronteffectués par un électricien qualifié.

3. Avant de faires des travaux à lʼinterieur de poste, la debranch-er à lʼinterrupteur à la boite de fusibles.

4. Garder tous les couvercles et dispositifs de sûreté à leurplace.

Page 7: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

Page

Installation .......................................................................................................Section ATechnical Specifications ........................................................................................A-1Location ................................................................................................................A-2Input Wiring............................................................................................................A-2Output Connections...............................................................................................A-2

1. Wire Feeder Connections ...........................................................................A-2Connection of AC-1200 (with NL Option) to LAF or LT34 .....................................A-3Connection of AC-1200 to NA-4 with Switch for ʻCurrent Controlʼ.........................A-3Connection of AC-1200 to NA-4 with rheostat for current control or LT-6. ............A-3

2. Output Studs ...............................................................................................A-43. Auxiliary Power ...........................................................................................A-4

Duty Cycle .............................................................................................................A-4

_______________________________________________________________________

Operation .........................................................................................................Section BSafety Precautions.................................................................................................B-1To set for machine or Remote Control...................................................................B-1To set Output Current ............................................................................................B-1

________________________________________________________________________

Accessories .....................................................................................................Section COptional Kit ............................................................................................................C-1

________________________________________________________________________

Maintenance ....................................................................................................Section DSafety Precautions ................................................................................................D-1

________________________________________________________________________

Troubleshooting ..............................................................................................Section ESafety Precautions.................................................................................................E-1How to Use Troubleshooting Guide.......................................................................E-1Troubleshooting Guide....................................................................................E-2,E-3

________________________________________________________________________

Wiring Diagram and Connection Diagrams .................................................Section F________________________________________________________________________

Parts Pages............................................................................................... P-701, P-28-J________________________________________________________________________

vi vi TABLE OF CONTENTS

Page 8: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

A-1INSTALLATION

IDEALARC® AC-1200

A-1

Weight1636 lbs.(742 kg.)

INPUT - SINGLE PHASE ONLY

RATED OUTPUT

PHYSICAL DIMENSIONS

RECOMMENDED INPUT WIRE GROUNDING CONDUCTOR AND FUSE SIZES

Standard Voltage

Duty Cycle100%

Current Range240/1200

Maximum Open Circuit Voltage

Depth38.00 in.

(965.2mm.)

Width22.30 in.

(566.4mm.)

Height53.50 in.

( 1358.9mm.)

AMPS AC1200 @ 44 Volts

Input Current at 100% Rated OutputSingle Phase Output Scott Connection

460/60440/50/60415/50/60380/50/60

182 209190 219201 232220 255

TECHNICAL SPECIFICATIONS - IDEALARC® AC-1200

86-88

RATING: IP21 ENCLOSURE

Power Factor @ Rated load With P.F. Capacitors

79%(60 Hz) 76%(50 Hz)

Input Copper Wire Size - 75˚C in Conduit Super Lag FusesVoltage/ Input Amps Power Input Wires Grounding Conductor Size in Amps

Hertz1 Phase Scott 1 Phase Scott 1 Phase Scott 1 Phase Scott

Conn. Conn. Conn. Conn.

460/60 182 209 #4/0 250MCM #4 #3 300 350

440/50/60 190 219 #4/0 250MCM #4 #3 300 350

415/50/60 201 232 #4/0 300MCM #4 #3 300 350

380/50/60 220 255 250MCM 350MCM #3 #3 300 400

Page 9: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

A-2INSTALLATION

IDEALARC® AC-1200

A-2

LOCATIONInstall the welder in a dry location where there is freecirculation of air in through the louvers in front and outthrough the louvers in the back of the case. A locationwhich minimizes the amount of smoke and dirt drawninto the machine reduces the chance of dirt accumula-tion that can block air passages and cause overheat-ing.

INPUT WIRING

Failure to fuse the input lines per the specificationsin this manual will constitute customer abuse andvoid the warranty.-----------------------------------------------------------------------------Have a qualified electrician make the complete inputconnection in accordance with the National ElectricalCode, all local codes and the connection diagramlocated inside the machine.

Be sure the voltage, phase and frequency of the inputpower is as specified on the welder nameplate.

For most installations, connect the AC-1200 to singlephase power or to one phase of a three phase line.Unbalanced line conditions can be easily avoided byproperly balancing the AC-1200 with other machineryon the lines.

When installing two or four Scott connected AC-1200machines for AC-AC tandem arc welding, three phaseinput power must be used. The terminals for connec-tions to provide an output phase angle less than orgreater than the usual 90º phase angle are includedon the input panel.

The AC-1200 does not have an input contactor.Therefore, include an external starter or disconnectswitch when planning the input circuit.

Remove the right side panel of the AC-1200 and bring theinput power lines through the hole in the back of the case.See the table below for reccomended sizing of input leadsand overcurrent protection.

The frame of the welder must be grounded, A stud markedwith the symbol located on the welder case backhole in the back of the case is provided for this purpose.See the National Electrical Code for details on propergrounding methods.

OUTPUT CONNECTIONS

1. Wire Feeder Connection

Turn the input power to the welder off. Remove thescrew and lift the hinged door on the front of the controlpanel to expose the terminal strips. Connect the leads ofthe wire feeder input control cable to the terminal stripsexactly as specified in the appropriate connection diagram.The AC-1200 to NA-4 connection diagrams are includedin the NA-4 Operating Manual IM-278. Attach the controlcables to the panel at the right of the terminal strip usingthe clamps provided.

If connecting the AC-1200 to an older NA-4 with the tog-gle switch type “Current Control” (below code 7532), a K-775 “Remote Control” must be purchased and installed inaccordance with the connection diagram S-15667 on page5. The “Remote Control” cord can be lengthened to anylength by properly splicing a four conductor cord to thestandard 25ʼ cord before connecting to the AC-1200 ter-minal strip.

If connecting the AC-1200 to an LAF-4 or the AC con-trols of the LT-34 tractor, the AC-1200 must be orderedwith the required “–NL” optional circuit installed. This kitincludes the K-775 “Remote Control”. Connect in accor-dance with diagram S-15666 on page 5.

To connect the AC-1200 to any other wire feeder, write tothe factory for instructions giving complete nameplate infor-mation for the specific equipment.

When connection to the terminal strips are completed,close the door and replace the screw.

WARNING

ELECTRIC SHOCKcan kill.

• Have an electrician installand service this equip-ment.

• Turn the input power off atthe fuse box before work-ing on equipment.

• Do not touch electricallyhot parts.

Page 10: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

A-3INSTALLATION

IDEALARC® AC-1200

A-3

Connection of AC-1200 (with NL Option) S-15666to LAF-4 or LT-34 4-18-75

Connection of AC-1200 to NA-4 S-15667

with Switch for ‘Current Control’ 4-18-75

Connection of AC-1200 toNA-4 with rheostat for current control or LT-6.

S-15602

6-22-84H

Page 11: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

A-4INSTALLATION

IDEALARC® AC-1200

A-4

2. Output Studs

Connect the work cables to the “To Work” stud onthe front of the AC-1200. Connect the electrodecables to the “Min”, “Med” or “Max” studs for theoutput desired. Actual current ranges for each studare indicated on the nameplate above each stud.Recommended cable sizes are listed below. Boththe “To Work” and “Max” studs have two terminalsto simplify connection of recommended cables inparallel. Tighten the nuts with a wrench.

Select cables required for combined work and elec-trode cable lengths up to 150ʼ from the followingtable:

Maximum Allowable Current for Copper Welding CableCables in accessory kit recommended below haveterminals as required to comply with applicableU.L. standards for safety.

150ʼ combined length electrode and work cables.

3. Auxiliary Power

920 volt-amperes of 115 volt AC power are avail-able from #31 and #32 on the AC-1200 terminalstrip.

DUTY CYCLE

The AC-1200 is rated for 100% duty cycle at 1200amps and 44 volts.

DutyCycle One 4/0 Two 4/0 Three 4/0 Four 4/0100% 500 930 1150 135080%* 560 1040 1290 1510

* Based on 10 minute cycle.

Page 12: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

B-1OPERATION

IDEALARC® AC-1200

B-1

TO SET FOR LOCAL OR REMOTECONTROLThe output can be controlled either from the AC-1200, the wire feeder or other remote locations.

To adjust the current from the wire feeder or otherremote locations, set the toggle switch on the front ofthe AC-1200 to “ “. To adjust the output currentfrom the AC-1200, set this switch to “ “.

T0 SET THE OUTPUT CURRENT

Start the AC-1200 using the line disconnect switch orbreaker installed with the input wiring. The yellow pilotlight on the front panel indicates when the welder ison.

Adjust the output current from minimum to maximumwithin the range set by the output stud connectionsusing either the “ “ rheostat on the AC-1200 (tog-gle switch set on “ “) or the wire feeder or otherremote rheostat (toggle switch set on “ “).

ELECTRIC SHOCKcan kill.

• Do not touch electrically live partsor electrode with skin or wetclothing.

• Insulate yourself from work andground.

• Always wear dry insulating gloves.

FUMES AND GASEScan be dangerous.

• Keep your head out of fumes.

• Use ventilation or exhaust toremove fumes from breathingzone.

WELDING SPARKScan cause fire orexplosion

• Keep flammable material away.

• Do not weld on containers thathave held combustibles.

ARC RAYScan burn.

• Wear eye, ear and bodyprotection.

SAFETY PRECAUTIONS

Read and understand this entire section before oper-ating the machine.

Observe additional Safety Guidelines detailedthroughout this manual.

WARNING

GRAPHIC SYMBOLS THAT APPEAR ONTHIS MACHINE OR IN THIS MANUAL

Output Control 1 Single Phase

Remote Control Setting 3 Three Phase

Local Control Settin Uo Rated No-Load Voltage

Input Power Type U1 Rated Input Voltage

Submerged Arc Welding U2 Rated Welding Voltage

Transformer Type X Rated Duty Cycle

Fuse I1 Rated Input Current

High Voltage Indicator I2 Rated Welding Current

High Temperature Indicator

Rated Frequency

Page 13: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

C-1ACCESSORIESC-1

OPTIONAL KIT: Remote control K775.

IDEALARC® AC-1200

Page 14: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

D-1MAINTENANCED-1

IDEALARC® AC-1200

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.• Have qualified personnel do the

maintenance and troubleshootingwork.

• Turn the input power OFF at the disconnectswitch or fuse box before working on thisequipment.

• Do not touch electrically live parts or electrodewith skin or wet clothing.

• Insulate yourself from work and ground.

• Always wear dry insulating gloves.------------------------------------------------------------------------See additional warning informationthroughout this operatorʼs manual.

------------------------------------------------------------

1. Every three months, blow out the machine withcompressed air. More frequent cleaning may benecessary in areas with chemical or metallic parti-cles and large quantities of dust.

2. The fan motors have sealed bearings which requireno service.

WARNING

Page 15: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

E-1TROUBLESHOOTINGE-1

IDEALARC® AC-1200

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

This Troubleshooting Guide is provided to help youlocate and repair possible machine malfunctions.Simply follow the three-step procedure listed below.

Step 1. LOCATE PROBLEM (SYMPTOM).Look under the column labeled “PROBLEM (SYMP-TOMS)”. This column describes possible symptomsthat the machine may exhibit. Find the listing thatbest describes the symptom that the machine isexhibiting.

Step 2. POSSIBLE CAUSE.The second column labeled “POSSIBLE CAUSE” liststhe obvious external possibilities that may contributeto the machine symptom.

Step 3. RECOMMENDED COURSE OF ACTIONThis column provides a course of action for thePossible Cause, generally it states to contact yourlocal Lincoln Authorized Field Service Facility.

If you do not understand or are unable to perform theRecommended Course of Action safely, contact yourlocal Lincoln Authorized Field Service Facility.

HOW TO USE TROUBLESHOOTING GUIDE

Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.Unauthorized repairs performed on this equipment may result in danger to the technician andmachine operator and will invalidate your factory warranty. For your safety and to avoid ElectricalShock, please observe all safety notes and precautions detailed throughout this manual.

__________________________________________________________________________

WARNING

Page 16: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

E-2TROUBLESHOOTINGE-2

IDEALARC® AC-1200

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDEDCOURSE OF ACTION

Welder will not start.

Welder will not weld (Contactorsoperating properly)

Welder will not weld (Contactors notoperating).

Welder welds at min. only no control.

1. Supply line fuse blown.

2. Open supply line lead.

3. Wrong supply line voltage.

1. Electrode or ground cable loose orbroken.

1. Thermostat on coil tripped. Welderoverheated (Fan motors operat-ing). light is on.

2. Thermal protection in auxiliarytransformer, T2, has opened. (Fanmotors not running)

3. Circuit across #2 and #4 not work-ing properly.

4. Wire feeder control power; Novoltage across #31 and #32.

1. Remote control switch in wrongposition.

2. Control rheostat open.

3. Control circuit open.

4. Open saturable reactor control coilor connection.

5. Welder control circuit dead: Novoltage across Control BoardTransformer X1-X2.

1. Replace fuse.

2. Look for possible cause andrepair.

3. Repair. Provide nameplate specifiedvoltage.

1. Tighten connection or repair bro-ken cable.

1. Check operation of fans and makesure there is no obstruction to airflow. Do not operate in excess ofwelder rating.

First check 8 Amp fuse and replace ifnecessary. If all recommendedpossible areas of misadjustmenthave been checked and the prob-lem persists, Contact your localLincoln Authorized FieldService Facility.

1. Switch to “ “ for welder rheo-stat control and to “ ” for con-trol through accessory.

If al l recommended possibleareas of misadjustment havebeen checked and the problempersists, Contact your localLincoln Authorized FieldService Facility.

Page 17: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

E-3TROUBLESHOOTINGE-3

IDEALARC® AC-1200

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDEDCOURSE OF ACTION

Welder welds at max. only no con-trol.

Contacts chatter.

Diodes or SCR ʼs on heat sinkassemblies shorted.

Shorted or grounded current controllrheostat.

Output By-Pass Capacitors open ordisconnected.

Free wheeling diode open or discon-nected.

P.C. board components failed.

1. Low supply line voltage. Checkwith Power Company.

Faulty contactor.

If all recommended possible areasof misadjustment have beenchecked and the problem persists,Contact your local LincolnAuthorized Field Service Facility.

Page 18: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

F-1DIAGRAMSF-1

IDEALARC® AC-1200

NO

TE

: T

his

diag

ram

is fo

r re

fere

nce

only

. It

may

not

be

accu

rate

for

all m

achi

nes

cove

red

by th

is m

anua

l. T

he s

peci

fic d

iagr

am fo

r a

part

icul

ar c

ode

is p

aste

d in

side

the

mac

hine

on

one

of th

e en

clos

ure

pane

ls.

If th

e di

agra

m is

ille

gibl

e, w

rite

to th

e S

ervi

ce D

epar

tmen

t for

a r

epla

cem

ent.

Giv

e th

e eq

uipm

ent c

ode

num

ber.

Page 19: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

F-2DIAGRAMSF-2

IDEALARC® AC-1200

AC-1200 SCOTT CONNECTION DIAGRAM

Page 20: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

F-3DIAGRAMSF-3

IDEALARC® AC-1200

M10033-1A.01

100

90

80

L2

L1

L2

L1

P1

C B ATO GROUND PER NATIONAL ELECTRIC CODE.

WORK

ELECTRODE

WORK

ELECTRODE

N.B.

MAIN TRANSFORMER LEAD ARC

4/O CABLES

4/O CABLE

N.C.

TEASER TRANSFORMER TRAIL ARC

4/O CABLES

4/O CABLE

N.C.

100

90

80

L2

L1

L2

L1

P1

C B ATO GROUND PER NATIONAL ELECTRIC CODE.

WORK

ELECTRODE

WORK

ELECTRODE

N.B.

N.B.

N.B.

3 PHASE SUPPLY LINE (N.A.)

NOTES:

N.B. ELECTRODE CABLES OF PARALLELED MACHINES SHOULD BE CONNECTED TO THE SAME RANGE TAP.

N.C. NUMBER OF 4/O CABLES CONNECTED: 1 ON MIN. TAP; 2 PARALLEL ON MED. TAP; 3 PARALLEL ON MAX. TAP.

TWO PARALLEL MACHINES SCOTT CONNECTED TO TWO OTHER PARALLEL MACHINES

FOR DESIRED PHASE ANGLE, INTERCONNECT MACHINES (AS SHOWN BELOW). BOTH PHASE ANGLES MUST BE THE SAME.

N.A. TO OBTAIN NORMAL PHASE SEQUENCE AT THE WELDING ARCS, THE INPUT LINE PHASE SEQUENCE SHOULD BE A-C-B.

AC-1200 SCOTT CONNECTION DIAGRAM

Page 21: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

F-4DIAGRAMSF-4

IDEALARC® AC-1200

AC-1200 AND PARALLELED DC-1000’s

Page 22: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

F-5DIAGRAMSF-5

IDEALARC® AC-1200

AC-1200 AND DC-1500’s

Page 23: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BEUSED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.

SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOSCONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.

LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS AETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.

LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.

Do not touch electrically live parts orelectrode with skin or wet clothing.Insulate yourself from work andground.

No toque las partes o los electrodosbajo carga con la piel o ropa moja-da.Aislese del trabajo y de la tierra.

Ne laissez ni la peau ni des vête-ments mouillés entrer en contactavec des pièces sous tension.Isolez-vous du travail et de la terre.

Berühren Sie keine stromführendenTeile oder Elektroden mit IhremKörper oder feuchter Kleidung!Isolieren Sie sich von denElektroden und dem Erdboden!

Não toque partes elétricas e elec-trodos com a pele ou roupa molha-da.Isole-se da peça e terra.

Keep flammable materials away.

Mantenga el material combustiblefuera del área de trabajo.

Gardez à l’écart de tout matérielinflammable.

Entfernen Sie brennbarres Material!

Mantenha inflamáveis bem guarda-dos.

Wear eye, ear and body protection.

Protéjase los ojos, los oídos y elcuerpo.

Protégez vos yeux, vos oreilles etvotre corps.

Tragen Sie Augen-, Ohren- und Kör-perschutz!

Use proteção para a vista, ouvido ecorpo.

Page 24: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA ASPRÁTICAS DE SEGURANÇA DO EMPREGADOR.

Keep your head out of fumes.Use ventilation or exhaust toremove fumes from breathing zone.

Los humos fuera de la zona de res-piración.Mantenga la cabeza fuera de loshumos. Utilice ventilación oaspiración para gases.

Gardez la tête à l’écart des fumées.Utilisez un ventilateur ou un aspira-teur pour ôter les fumées des zonesde travail.

Vermeiden Sie das Einatmen vonSchweibrauch!Sorgen Sie für gute Be- undEntlüftung des Arbeitsplatzes!

Mantenha seu rosto da fumaça.Use ventilação e exhaustão pararemover fumo da zona respiratória.

Turn power off before servicing.

Desconectar el cable de ali-mentación de poder de la máquinaantes de iniciar cualquier servicio.

Débranchez le courant avant l’entre-tien.

Strom vor Wartungsarbeitenabschalten! (Netzstrom völlig öff-nen; Maschine anhalten!)

Não opere com as tampas removidas.Desligue a corrente antes de fazerserviço.Não toque as partes elétricas nuas.

Do not operate with panel open orguards off.

No operar con panel abierto oguardas quitadas.

N’opérez pas avec les panneauxouverts ou avec les dispositifs deprotection enlevés.

Anlage nie ohne Schutzgehäuseoder Innenschutzverkleidung inBetrieb setzen!

Mantenha-se afastado das partesmoventes.Não opere com os paineis abertosou guardas removidas.

Page 25: Operator’s Manual IDEALARC AC1200 - Lincoln Electric · PDF fileIDEALARC ® AC1200 Operator’s Manual Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345)

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •