operation and maintenance 9400awy

Upload: nguyen-huu-luong

Post on 03-Apr-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 Operation and Maintenance 9400AWY

    1/46

    9400AWY

    9400AWY Introduction

    9400AWY Characteristics

    Comissioning 9400AWY Link

    Trouble Shooting 9400AWY Link

    Gtel Central Internal Training Program --

  • 7/28/2019 Operation and Maintenance 9400AWY

    2/46

    9400 Introduction

  • 7/28/2019 Operation and Maintenance 9400AWY

    3/46

    9400 AWY

    Solution

    9400 AWY: Low-Medium Capacity

    Low Medium capacityplatform

    High spectrum

    efficiency PDH interfaces Ethernet interfaces Ideal for Urban

    backhaul

    PDH interfaces up 32xE1

    4xEthernet ports 10/100/1000 BaseT- Ideal for WiMAX backhauling

    - Up to 64Mbps throughput supporting tri-sectors WBS

    - Integrated L2 switch for traffic aggregation

    - QoS awareness

    Split-mount configurationOutdoor unit (ODU):

  • 7/28/2019 Operation and Maintenance 9400AWY

    4/46

    The cost-optimized Alcatel 9400 AWY is ideal for short-haul digital transmissions

    In high-density mobile networks, particularly mobile backhaul networks (2G, 2.5G, 3G and WiMAX),

    Node BUMTS CN

    UMTS network

    ACCESS COREMOBILE

    RNC

    Concentrationpoint

    As well as utility networks (railways, electricity, pipelines), regionaland local traffic systems, and private data networks (WANs, LANs).

  • 7/28/2019 Operation and Maintenance 9400AWY

    5/46

    Complete ETSI frequency coverage

    Traffic interfaces

    Frequency band availability according to roadmap

    7GHz - 8GHz - 13GHz - 15GHz - 18GHz - 23GHz - 25GHz -38GHz

    1 to 32 E1

    1 x E3

    4 x 10/100/1000 Base-T up to64Mbps

    Unique fine E1/Ethernet modularity

    Full flexibility with no wasted capacity

    9400 AWY principal technicalcharacteristics

  • 7/28/2019 Operation and Maintenance 9400AWY

    6/46

    Typically the distances achieved with99,99% of the time of availability are :

    From 10km to 50km for 7/8 Ghz From 05km to 10km for 13 to 18 Ghz

    From a few hundred meters up to 10km for23Ghz to 38Ghz

    Distances achieved

  • 7/28/2019 Operation and Maintenance 9400AWY

    7/46

    Equipment architecture

    Splitmount architecture

    Indoor Unit (IDU)

    Outdoor Unit (ODU)

    IDUODU cable

    Configurations : 1+0and 1+1

    The 2+0

    configuration is not

  • 7/28/2019 Operation and Maintenance 9400AWY

    8/46

    Technical characteristics

    IDU 32Mbps - R2.0

    capacity agility from 2 to 32Mbps software controlled daughter boards to provide E3 Daughter board to provide 2 ports in Fast Ethernet

    IDU 64Mbps - R2.1

    capacity agility from 2 to 64Mbps software controlled daughter board to provide 4 ports Gigabit Ethernet integrating Level2 switch

    Two power supply options 48 VDC for standard installations in equipment rooms 24/60 VDC available

    Two types ofIDU

    End of Life

    IDU (Indoor Unit)

  • 7/28/2019 Operation and Maintenance 9400AWY

    9/46

    In 1+0: 1U optimised Main IDU

    minimum configuration 8E1/16Mbps or 16E1/32Mbps

    modular slot for expansion up to 32E1/64Mbps common to all frequency bands

    In 1+1: 1U complete Extension IDU

    AWY offers both full protection and radio protection

    AWY Indoor can be replaced for repair without traffic impact

    common to all frequency bands

    configurations 1+0 and 1+1

    IDU (Indoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    10/46

    9400 AWY64Mbps IDU Technical characteristics

    9400 AWY 64Mbps ExtensionIDU

    9400 AWY 64Mbps MainIDU

    Trafficmodules

    L2 Ethernet

    16E1

    16E1

    16E1

    IDU (Indoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    11/46

    The IDU incorporates the baseband processing and offers tributariesinterfaces as well as service channel and supervision.

    The IDU is frequencyindependent, but capacitydependent

    IDU (Indoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    12/46

    Description of IDU Main unit

    Front View

    Rear View

  • 7/28/2019 Operation and Maintenance 9400AWY

    13/46

    IDU Main Unit LEDssummary

  • 7/28/2019 Operation and Maintenance 9400AWY

    14/46

    Power Supplyconnector

    IDU-ODUconnector

  • 7/28/2019 Operation and Maintenance 9400AWY

    15/46

    ODU (Outdoor Unit)The ODU consists of a cabinet including the modem + transceiver

    of a channel. one for all frequency bands from 13 to 38 GHz :

    The branching (diplexer) is internal to the ODU cabinetThe only differences among the frequency bands : the diplexer

    and the RF section For all frequency bands from 7 to 8 GHz :

    ODU is composed by two independent units: the branching(diplexer) and the RF section (transceiver)

  • 7/28/2019 Operation and Maintenance 9400AWY

    16/46

    ODU Block Diagram

    ODU (Outdoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    17/46

  • 7/28/2019 Operation and Maintenance 9400AWY

    18/46ODU configurations

    ODU (Outdoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    19/46

    ODU (Outdoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    20/46

    ODU (Outdoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    21/46

    ODU Pole mounting solutions diagrams

    1+0 solution with fullintegrated antenna

    1+1 solution withfull integratedantenna10dB coupler

    Complete antenna portfolio Integrated antenna of 1FT, 2FT, 3FT, 4FT and 6FT Non integrated antenna

    1+0 solution withnon integratedantenna

    ODU (Outdoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    22/46

    Part list of ODU

    Example part list of ODU 13Ghz

    ODU (Outdoor Unit) cont

  • 7/28/2019 Operation and Maintenance 9400AWY

    23/46

    ODU (Outdoor Unit) cont

    ODU C l (i 1 1 t ti )

  • 7/28/2019 Operation and Maintenance 9400AWY

    24/46

    ODU Coupler (in case 1+1 protection)

  • 7/28/2019 Operation and Maintenance 9400AWY

    25/46

    IDUODU cableThe connection between the IDU and the ODU is realized with asingle coaxial cable and N50 ohm connectors (2 cables in 1+1configurations).On this cable the following signals are present: DC voltage to the remote power supply of the ODU; HDB3 Tx signal; HDB3 Rx signal.

  • 7/28/2019 Operation and Maintenance 9400AWY

    26/46

    Commisioning

    Login by CT

    NE Parameter Configuration

    Radio Configuration Dem fail, High BER alarms

  • 7/28/2019 Operation and Maintenance 9400AWY

    27/46

    Login by CT

    Execute Lower Layers Manager

    Execute AWY_CT_V01.07.18

    Input : IP address

    (default 10.0.1.2)

    Input : User : initial

    Pass : initialing

  • 7/28/2019 Operation and Maintenance 9400AWY

    28/46

    NE Parameter Configuration

    iguration->System Setting -> NE configuration

  • 7/28/2019 Operation and Maintenance 9400AWY

    29/46

    nfiguration->System Setting -> Link Identifier

    NE Parameter Configuration (cont)

  • 7/28/2019 Operation and Maintenance 9400AWY

    30/46

    dio Configuration : Configure Shifter and Frequency

    Radio Configuration

  • 7/28/2019 Operation and Maintenance 9400AWY

    31/46

    Radio Configuration : Configure Tx power

    Radio Configuration (cont)

  • 7/28/2019 Operation and Maintenance 9400AWY

    32/46

    Show Power Measure :

    Radio Configuration (cont)

  • 7/28/2019 Operation and Maintenance 9400AWY

    33/46

    ine Interface -> Select triburaty PDH

    Tributary Configuration

  • 7/28/2019 Operation and Maintenance 9400AWY

    34/46

    NMS Configurationnfiguration -> Network Configuration -> Local Configuration

    This local IP address is the IP address associated to the F interface andto the other interfaces which use the PPP protocol (the 3 NMS

    channels).

    NMS Configuration (cont)

  • 7/28/2019 Operation and Maintenance 9400AWY

    35/46

    NMS Configuration (cont)figuration -> Network Configuration -> IP point to point Configuration

  • 7/28/2019 Operation and Maintenance 9400AWY

    36/46

    NMS Configuration (cont)nfiguration -> Network Configuration -> Ethernet Configuration

  • 7/28/2019 Operation and Maintenance 9400AWY

    37/46

    Trouble Shooting

    Available Loopbacks

    Tx mute function and Rx received

    Flow chart to handle : Mod LOS, Txfail, Rx fail, Dem fail, High BERalarms

    A il bl L b k

  • 7/28/2019 Operation and Maintenance 9400AWY

    38/46

    Available Loopbacks

    A il bl L b k ( t)

  • 7/28/2019 Operation and Maintenance 9400AWY

    39/46

    is loopback is useful to check the continuity of the signal overall pathcluding the LIU interface in the remote station

    Near End Tributary Loopback

    Available Loopbacks (cont)

    Tx mute function

  • 7/28/2019 Operation and Maintenance 9400AWY

    40/46

    Tx mute function

  • 7/28/2019 Operation and Maintenance 9400AWY

    41/46

    Mod Los Alarm

  • 7/28/2019 Operation and Maintenance 9400AWY

    42/46

    R f il Al

  • 7/28/2019 Operation and Maintenance 9400AWY

    43/46

    Rx fail Alarm

  • 7/28/2019 Operation and Maintenance 9400AWY

    44/46

    Dem fail Alarm

  • 7/28/2019 Operation and Maintenance 9400AWY

    45/46

    HBER Alarm

  • 7/28/2019 Operation and Maintenance 9400AWY

    46/46

    Q&A !!!