FERRARO GROUPLmf Clima 201612
RKB
Sheet metal supporting frame and double shell curtain panels externally pre-painted, fully removable with 20 mm thick internal thermal and acoustic insulation. Average efficiency static heat recovery, of the air-air type cross-flows with aluminium exchanger plates equipped with additional sealing; aluminium drain pan to collect the condensation, extended to the whole area dedicated to the thermal treatment. Cross-flow heat recovery unit certified by Eurovent according to UNI EN 308.The unit comes without filters; optionally you can choose compact G4 filters 98 mm, or any combination of compact filters by type G4 48 mm, M6, F7, or F8, according to UNI EN 779:2012.Filters can all be removed from the bottom of the unit.Forward-curved blades centrifugal fans with double air inlet directly coupled with multi speed motors; the fans comply to the year 2013-2015 to the ErP directive 2009/125/EC, in accordance with the European regulation 327/2011. The unit comes complete with IP 56 electrical box and connection terminals for each fan.
Heat recovery units
from 100 to 5.400 m3/h
ERP 2015 HORIZONTAL ORIENTATION
EFFICIENCY
>50%
INSIDEVERTICALORIENTATION
ONLYEXTRA-EU
![Page 2: ONLY EXTRA-EU ORIENTATION · g49 RKB 500 E.S.P 52,0 53,0 54,0 55,0 56 ,0 57 ,0 58 ,0 59 ,0 6 0,0 0 50 100 150 200 250 300 350 400 450 500 550 16 00 19 00 2200 2500 28 00 3100 3400](https://reader033.vdocuments.mx/reader033/viewer/2022052001/60140a9d9373eb02c876c883/html5/thumbnails/2.jpg)
13Lmf Clima 2016FERRARO GROUP FERRARO GROUP
Accessories
G4 filter 98mm thick G49
G4 filter 48mm thick G45
High efficiency M6 filter FC6
High efficiency F7 filter FC7
High efficiency F8 filter FC8
Unit conversion Kit from Horizontal to Vertical KVU
External by-pass CDM
Electric coil section SKE
Water coil section SAF
Adiabatic Cooler/Humidifier HCP
Roof coverage - Horizontal unit TPR
Feet 180mm high (kit = 4 pieces) PD2
3-position speed switch RCV
3 step fan speed control CVU
Control panel PCR
Remote temperature sensor for PCR NTC
Power relay board LVN
Multi-function control panel LCE
3-way modulating valve with actuator - SAF - V33
PARTIALOUTSIDE
ROUND ADAPTER FOR CONNECTINGCIRCULAR DUCTS AS STANDARD
POSSIBILITY OF INSPECTION, MAINTENANCE AND REPLACEMENT OF
ALL THE COMPONENTS, EVEN FOR A UNIT INSTALLED
HIGH EFFICIENCY ALUMINIUM HEAT EXCHANGER
![Page 3: ONLY EXTRA-EU ORIENTATION · g49 RKB 500 E.S.P 52,0 53,0 54,0 55,0 56 ,0 57 ,0 58 ,0 59 ,0 6 0,0 0 50 100 150 200 250 300 350 400 450 500 550 16 00 19 00 2200 2500 28 00 3100 3400](https://reader033.vdocuments.mx/reader033/viewer/2022052001/60140a9d9373eb02c876c883/html5/thumbnails/3.jpg)
FERRARO GROUPLmf Clima 201614
ModelsRKB 500 1000 2000 3200 4300
AirflowMax
m3/h500 1000 2000 3200 4300
Med 330 900 1500 2600 -Min 220 800 1100 2100 3200
Static pressure (4)Max
Pa155 125 130 160 180
Med 100 105 115 150 -Min 45 80 80 105 110
1m sound pressure levelMax
dB(A)51 52 58 59 62
Med 50 49 54 53 -Min 44 45 42 51 55
Nom motor power W 2 x 60 2 x 147 2 x 420 2 x 550 2 x 750Maximum total current A 2 x 0,70 2 x 1,40 2 x 3,80 2 x 5,40 2 x 3,30Max. total power absorbed kW 2 x 0,22 2 x 0,27 2 x 0,80 2 x 1,20 2 x 1,89Specific fan power W/(m3/s) 1019 720 1125 1170 12132009/125/EC ErP Compliance - Free 2015 2015 2015 2015Fan speed n° 3 3 3 3 2Min degree of Protection - IP 32 IP 44 IP 44 IP 44 IP 55Min temperature class - B F F F FPower supply V-Ph-Hz 230-1-50 400-3-50
Efficiency (1)Max
%58,7 56,4 50,0 53,8 54,6
Med 61,6 57,2 51,7 55,5 -Min 64,3 58,0 53,5 57,1 56,9
Recovered power (1)Max
kW2,40 4,70 8,30 14,30 19,50
Med 1,70 4,30 6,40 12,00 -Min 1,20 3,90 4,90 10,0 15,1
Supply temperature (1)Max
°C8,3 7,8 6,3 7,2 7,4
Med 9,0 8,0 6,7 7,6 -Min 9,6 8,2 7,1 8,0 7,9
Efficiency class according to UNI EN 13053. Max - H4 H4 H5 H5 H5SAF WATER COOLING SECTION
Total cooling capacity (2) kW 3,10 6,00 11,2 19,2 25,4Sensible cooling capacity (2) Max kW 1,86 3,60 6,72 11,5 15,2Supply temperature (2) Max °C 17,9 18,4 19,4 18,7 18,8Heating capacity (3) Max kW 6,30 12,2 23,7 37,9 53,9Supply temperature (3) Max °C 44,5 43,0 40,1 41,2 43,4Water flow rate Max m3/h 0,53 1,03 1,91 3,29 4,37Water side pressure drop Max kPa 11 17 11 29 22Air pressure drop Pa 63 45 87 84 50Coil rows Max - 3 3 3 3 3
SKE ELECTRIC HEATER FOR PRE- OR POST-HEATINGStages 1 1 1 1 1Heating capacity Max kW 2,00 4,50 9,00 12,0 18,0ΔT air side Max °C 11,8 13,2 13,2 11,8 13,2Pressure drop Max Pa 5 5 13 12 9Power supply V-Ph-Hz 230-1-50 400-3+N-50
HIGH EFFICIENCY FILTERSG49 Pressure drop G4 Max Pa 35 48 66 85 56G45 Pressure drop G4 Max Pa 50 69 95 122 81FC6 Pressure drop M6 Max Pa 78 108 149 191 127FC7 Pressure drop F7 Max Pa 117 162 224 287 190FC8 Pressure drop F8 Max Pa 143 198 274 350 232
(1) External air Winter – 5°C, 80% RH ambient air at 20°C, 50% RH, Summer 32°C 50% RH, ambient air 26°C 50% RH (2) Air outlet conditions of the recovery system, inlet water 7°C, outlet 12°C(3) Air outlet conditions of the recovery system, inlet water 70°C, outlet 60°C(4) Static pressure E.S.P. calculated with G49 mounted
![Page 4: ONLY EXTRA-EU ORIENTATION · g49 RKB 500 E.S.P 52,0 53,0 54,0 55,0 56 ,0 57 ,0 58 ,0 59 ,0 6 0,0 0 50 100 150 200 250 300 350 400 450 500 550 16 00 19 00 2200 2500 28 00 3100 3400](https://reader033.vdocuments.mx/reader033/viewer/2022052001/60140a9d9373eb02c876c883/html5/thumbnails/4.jpg)
15Lmf Clima 2016FERRARO GROUP FERRARO GROUP
Performance
Air flow (m3/h)
E.S.
P. (P
a)
50,0
52,0
54,0
56,0
58,0
60,0
62,0
64,0
66,0
68,0
70,0
0
50
100
150
200
250
300
350
400
100 150 200 250 300 350 400 450 500 550 600 650
eff %
max
min
med
Effici
ency
(%)
P.D
. (Pa
)
0
50
100
150
200
100 150 200 250 300 350 400 450 500 550 600 650
fc8
ske
fc6
fc7
safg45
g49
RKB
500
E.S.
P. (P
a)
52,0
53,0
54,0
55,0
56,0
57,0
58,0
59,0
60,0
050
100150200250300350400450500550
1600 1900 2200 2500 2800 3100 3400 3700 4000
max
min
med
eff %
Effici
ency
(%)
P.D
. (Pa
)
0
50
100
150
200
250
300
350
400
450
1600 1900 2200 2500 2800 3100 3400 3700 4000
fc8
ske
saf
fc7
fc6
g45
g49
RKB
3200
E.S.
P. (P
a)
50,0
52,0
54,0
56,0
58,0
60,0
62,0
0
50
100
150
200
250
300
350
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600
eff %
max
min
med
Effici
ency
(%)
P.D
. (Pa
)
0
50
100
150
200
250
300
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600
fc8
ske
fc6
fc7
saf
g45
g49
E.S.
P. (P
a)
48,0
49,0
50,0
51,0
52,0
53,0
54,0
55,0
56,0
57,0
58,0
0
50
100
150
200
250
300
350
400
600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600
eff %
max
min
med
Effici
ency
(%)
P.D
. (Pa
)
0
50
100
150
200
250
300
350
400
600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600
fc8
ske
fc6
fc7
saf
g45
g49
RKB
2000
RKB
1000
PERFORMANCE COMPONENTS PRESSURE DROP
Air flow (m3/h)Air flow (m3/h)
Air flow (m3/h)
Air flow (m3/h)
Air flow (m3/h)
Air flow (m3/h)
Air flow (m3/h)
![Page 5: ONLY EXTRA-EU ORIENTATION · g49 RKB 500 E.S.P 52,0 53,0 54,0 55,0 56 ,0 57 ,0 58 ,0 59 ,0 6 0,0 0 50 100 150 200 250 300 350 400 450 500 550 16 00 19 00 2200 2500 28 00 3100 3400](https://reader033.vdocuments.mx/reader033/viewer/2022052001/60140a9d9373eb02c876c883/html5/thumbnails/5.jpg)
FERRARO GROUPLmf Clima 201616
Noise levelsThe table lists the sound power values (SWL) in octave bands and totals; it also indicates the values of sound pressure level (SPL) at 1 m, 5 m and 10 m at supply, return and at the outside of the unit.All values refer to the operation of the ducted unit at FULL speed and at the nominal flow rate.
SPL return
SPL external
RKB SWL [dB] OCTAVE BAND [HZ] SWL SPL SUPPLY SPL RETURN SPL OUTSIDE1 m 5 m 10 m 1 m 5 m 10 m 1 m 5 m 10 m
63 125 250 500 1000 2000 4000 8000 dB dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)500 78,6 79,4 77,6 69,0 70,4 71,4 66,9 62,2 84 77 63 52 46 60 49 43 51 40 34
1000 72,4 78,9 75,9 71,1 72,8 73,7 71,7 69,0 83 79 65 53 48 62 50 45 52 40 352000 90,7 82,9 90.1 79,4 78,6 79,5 79,3 75.5 94 87 72 61 56 69 58 53 58 47 423200 103,4 83,2 88,7 78,6 80,0 79,9 77,6 72,6 104 87 72 61 56 69 58 53 59 48 434300 95,4 89,0 92,5 87,7 81,5 82,6 83,5 79,0 99 91 76 65 60 72 61 56 62 51 46
Dimensions and weights
RKB 500 1000 2000 3200 4300P mm 375 450 450 615 675L mm 400 700 700 700 850H mm 270 410 470 490 630D mm 200 315 355 450 500
WEIGHT SKE kg 7 15 16 21 31WEIGHT SAF kg 9 20 21 25 40WEIGHT HCP kg 9 17 21 25 40
H
LP
DD
H
LP
LP
D
H
SKE SAF HCP
Performance
Air flow (m3/h)
E.S.
P. (P
a)
50,0
51,0
52,0
53,0
54,0
55,0
56,0
57,0
58,0
59,0
60,0
0
50
100
150
200
250
300
350
400
450
3000 3300 3600 3900 4200 4500 4800 5100 5400
eff %
max
min
Effici
ency
(%)
Air flow (m3/h)
P.D
. (Pa
)
0
50
100
150
200
250
300
3000 3300 3600 3900 4200 4500 4800 5100 5400
fc8
ske
fc6
saw
fc7
g49
g45
PERFORMANCE COMPONENTS PRESSURE DROP
SPL supply
RKB
4300
![Page 6: ONLY EXTRA-EU ORIENTATION · g49 RKB 500 E.S.P 52,0 53,0 54,0 55,0 56 ,0 57 ,0 58 ,0 59 ,0 6 0,0 0 50 100 150 200 250 300 350 400 450 500 550 16 00 19 00 2200 2500 28 00 3100 3400](https://reader033.vdocuments.mx/reader033/viewer/2022052001/60140a9d9373eb02c876c883/html5/thumbnails/6.jpg)
17Lmf Clima 2016FERRARO GROUP FERRARO GROUP
E
AR
M
M90 E90
R90 A90
E
A R
M
M90E90
B A
R90A90
100 100
H
D
C
F
E
Controls
type A
type B
KEY
M supply
R return
E exhaust
A fresh air
RKB 500 1000 2000 3200 4300A mm 750 900 1000 1300 1400B mm 750 900 1000 1300 1400C mm 295 410 470 530 705D mm 200 315 355 450 500E mm 145 205 235 265 352F mm 202 240 265 340 365
WEIGHT kg 41 68 99 155 235Drains Inch 2 x 1/2" F 2 x 1/2" F 2 x 1/2" F 2 x 1/2" F 2 x 1/2" F
H CDM mm 75 75 100 150 175
RCV CVU (*) PCR (*) LCEManual selection of 3 speed • • • •Automatic/manual selection of speed • •Manual ON-OFF • • • •Cool/change over valve management SAF+V33 • •Heat valve management SAF+V33 • •Water coil anti-freeze management •ON-OFF electric heater management SKE • •Filter pressure switch management •Free-cooling damper management CDM •Alarms management •Post ventilation • •Weekly programming •Remote ON-OFF •Mode change (hot/cold) from digital input • Remote display with internal sensor • •BMS Modbus RS485 protocol •Reference diagram 1 1 2 3
(*) to be combined with LVN