online emergency lighting inverter three phase 3 kw - 125 kw

10
Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

Upload: justice-keating

Post on 30-Mar-2015

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

Online Emergency Lighting Inverter

Three Phase 3 KW - 125 KW

Page 2: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

What is the Fortress 3?It is a three phase

Emergency Lighting Inverterit is used for outdoor applications, and

is online at all times.It defends your environment against

unwanted power outage andelectrical disturbances. It continually

maintains efficient AC Emergency Powerto operate all emergency lighting fixturesat “full-light” output, providing superior

dependability and security tocommercial/industrial environments

in a small footprint.

It is available in power levels of3.0, 4.5, 6.0, 8.0, 10.0, 12.0, 16.0,

20.0, 24.0, 30.0, 40.0, 60.0,80.0, 100.0 and 125.0 KW

Page 3: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

What makes theFortress 3 different?

• DSPM Watchdog software always on guard.• Dependable DSP/PWM technology for unsurpassed reliability.• Economical for the lowest overall cost for your light safety, with an Energy Star Rating.• Temperature compensating technology that controls batteries for the longest battery life.• Sealed maintenance free batteries.• Full light output for entire 90 minutes.• Self-diagnostics for a safe and secure lighted environment.• Pure sine wave output for all types of lamps.• ECM module is a patented technology used by DSPM.• Backup solutions for multiple applications such as: indoor and outdoor emergency lighting, exits, cash registers, computers, strategic electronics and more!• 10 Year pro-rated battery warranty• 5 Year power train warranty• Meets federal, state and local codes: UL924, NFPA 101, NFPA 70, NEC and OSHA.• Cities of Chicago and New York Approved.• Complies with the Buy American Act.

Page 4: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

Specifications*Standard Power Levels...........3.0, 4.5, 6.0, 8.0, 10.0, 12.0, 16.0, 20.0, 24.0,

30.0, 40.0, 60.0, 80.0, 100.0 and 125.0 KW*Input Voltage .......................... 208Y/120, 480Y/277, 208 or 480VAC*Input Voltage Range...............+10%. -15%*Output Voltage........................ 208Y/120 or 480Y/277 VAC*Output Voltage Regulation......±2% for all loads and battery discharge mode*Output Frequency Range........60 Hz, ±1%Output Wave Form....................Sine-wave <5% @ 100% linear loadCrest Factor...............................2.5:1 typicalInput Protection.........................Input Main Circuit BreakerOutput Protection......................Output Main Circuit BreakerSurge Protection.......................The unit will protect itself and the load against surges

as defined in ANSI/EEE C62.45 category A and BBattery.......................................Sealed maintenance-free (AGM) lead calciumRecharge Current.....................Conforms to UL924 standardsExternal Battery........................Provision for hardware connection of

external battery cabinets or DC sourceEfficiency..................................≥92% at 100% linear loadAudible Noise...........................<45dB measured on Response Curve “A” Safety Agencies.......................Listed to UL standard 924Operating Temperature...........-20º to 50ºC (-4º to 122ºF)Storage Temperature...............-20º to 60ºC (-4º to 140ºF)Humidity...................................5 - 100%, Non-condensingCabinet…..................................NEMA 3R

*Consult factory for others. Specifications subject to change without notice.

Page 5: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

OptionsEnvironmental Control ModuleNormally OFF Circuit 120VAC or 277VACNormally OFF “Hold On” 120VAC or 277VACOutput Circuit Breaker(s)Emergency Power OffRemote Indicator PanelEthernet Interface with RS232Fax ModemForm C ContactsOnsite StartupInternal Dimmer BypassExternal Maintenance BypassHeat ExchangerHeaterExtended Warranty

Subject to change without notice.

Page 6: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

System Drawing:

Specification

Chart:

Page 7: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

BrochureFor your convenience you can download the brochure with

all the information about our Fortress 3 from our website: www.dspmanufacturing.com

Page 8: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

Data SheetFor your convenience you can download the data sheet with

all the information along with how to order ourFortress 3 from our website: www.dspmanufacturing.com

Page 9: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

Other DownloadsFor your convenience you can also download the

technical specification, manual, field service documents, andwhite papers for the Fortress 3 from our website:

www.dspmanufacturing.com

Page 10: Online Emergency Lighting Inverter Three Phase 3 KW - 125 KW

If you have any other questions or would like more information

Call 1.877.DSPM.POWER1.877.377.6769

Thank You!089-0013-01A