office of the treasurer - eproc.punjab.gov.pk · equipped with a differential pt-100 rtd probe, the...
TRANSCRIPT
Page 1 of 28
BID DOCUMENTS
Selected bids are invited on Single Stage Two Envelopes (Technical & Financial) basis by University
of the Punjab from manufacturers, authorized distributors, dealers, firms, registered with GST & NTN
and PRA (if applicable), for the procurement of below mentioned“ Laboratory Equipment for
Centre for Coal Technology”. Single Envelope Containing Two Separate Envelopes must be
marked as “Financial Proposal” & “Technical Proposal”. (C&F Basis Only)
OFFICE OF THE TREASURER PROCUREMENT WING – ACCOUNTS DEPARTMENT
2nd Floor, Admin Block, Quaid-e-Azam Campus, Lahore. Tel: 042-99233105 Fax: 042-35863230 Email: [email protected]
Price: Rs.500/- No. /PW/Bid Date /2019
OFFICE OF THE TREASURER PROCUREMENT WING – ACCOUNTS DEPARTMENT
2nd Floor, Admin Block, Quaid-e-Azam Campus, Lahore. Tel: 042-35838310, Fax: 042-35863230 Email: [email protected]
Price: Rs.1000/- No. ---PW/Bid Date /2015
PROCUREMENT WING – ACCOUNTS DEPARTMENT
2nd Floor, Admin Block, Quaid-e-Azam Campus, Lahore. Tel: 042-35838310, Fax: 042-35863230 Email: [email protected]
No. /PW Dated: /2014
Page 2 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
1
Multiflash-Abel Flash Point Tester With
Multiflash Base Unit
Highlights of the Equipment
The Multiflash – Abel fully automates and conforms
precisely to International Abel Closed Cup and
Equipment test Methods
Useful for equilibrium and Non-Equilibrium tests
The equipment enable training about obtaining multiple
flash point data of fuel oils, lubricants
The equipment is suitable forflash point application of jet
fuels, solvents, chemicals etc. and provides training to
measure the flammability.
The flash tester provides an increased temperature range
of operation as compared with other testers, allowing
greater flexibility in testing samples according to the
Abel test method
The unit provides a test range 110oC and can be extended
to -30oC by any appropriate external chiller
The flash point tester tests are simply conducted by
mounting the flash cup filled with sample into the test
position and selecting a pre- or user-programmed test
method
Automation routines provide accurate test results
Specifications (or equivalent)
Method (s) : ISO 11523; BS 3900 Parts A8 & A9; BS 6664
Parts 1 & 2; IP 170 ;IP 491; IP 492; IP 304 (obs) Part 2; EN
ISO 13736; BS 2000 Part 170
Equilibrium tests - Non-Equilibrium tests
Flash/no-flash tests - Flexible automated search mode
Ambient to 93oC ( 5
oC to 93
oC with cryostat )
Gas or electric ignition
Cooling boost module: Kerosine 500mL
Calibration & Verification: digital photo Tachometer;
Portable Digital Barometer
Multiflash Automatic Flash Point – Universal base unit
01
No.
Page 3 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
2
Multiflash Cleveland Flash Point Module With
Multiflash Base Unit
Highlights of the Equipment
The automated Cleveland Open Cup flash point tester
accurately determines flash and fire point temperature of
viscous petroleum products including oils and bitumens over
an extended temperature range. The flash/fire point tests are simply conducted by mounting flash cup
filled with sample into position and selecting a pre-programmed test
method or the search mode determine an approximate flash point.
The test results are automatically corrected to standard
pressure (101.3 kPa). Equipped with a different Pt-100RTD probe, the system is designed
to duplicate the response time of a mercury-in-glass thermometer
Flash and fire point testing
Flexible automated mode testing
Extended temperature range from ambient to 400OC
Gas or electric flexible ignition option
Automatic sniffer
Specifications (or equivalent)
Method (s) : AASTHO T48; ASTM D92; IP 36; EN ISO 2592;
BS 2000 Parts 36 & 403 (obs);
Fully self-contained flash/fire point test module
Ambient to 400OC
Exact conforms to the requirements of Cleveland test method
Automatic set up of test parameters
Gas or electric ignition
Automatic heating control, flash and fire detection
Automatic test result & end of test audible warning
Automatic snuffer
Centigrade or Fahrenheit temperature display
Automatic barometric correction
Calibration & Verification: FLASHCHECK (pack of 3x80mL)
Multiflash Automatic Flash point tester – universal base unit
01
No.
3
Multiflash Tag Flash Point Module With Multiflash Base
Unit Highlights of the Equipment
Used for determining the flash point of volatile flammable materials.
Conforming to CE requirements. Consisting of:
o Electric furnace with electronic controller of heating power
o Flame rotating ignition device (LPG supply is required)
o Glass cup - Insulating plate.
Easy to clean stainless steel case
Useful for equilibrium and Non-equilibrium tests
Flash/no-Flash testing - Flexible automated search mode
Ambient to 93OC (5
OC to 93
OC with optional cryostat)
Gas or electric ignition
Specifications (or equivalent)
Method (s) : ASTM E502; ASTM D56; ASTM D3934; ASTM D3941;
ISO 1516; ISO 1523; FTM 791 1101; IP 491; IP 492; IP 304 (obs)
PART 2
Fully self-contained flash point test module
Flash point to 93OC (200
OF)
Exact conforms to the requirements of Tag test method
Automatic set up of test parameters
Gas or electric ignition
Automatic heating control and flash detection
Automatic test result & end of test audible warning
Centigrade or Fahrenheit temperature display
Automatic barometric correction
Cooling boost accessory for multiflash instruments
Calibration & Verification: FLASHCHECK (pack of 3x80mL)
Multiflash automatic flash point tester – universal base unit
01
No.
Page 4 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
4
Semi-Automatic Tag Open Cup Flash Point Tester
With Multiflash Base Unit
Highlights of the Equipment
Used for determining the flash point of volatile flammable
materials. Conforming to CE requirements. Consisting of
o Electric furnace with electronic controller of heating power
o Flame rotating ignition device (LPG supply is required)
o Glass Cup
Equilibrium tests and non-equilibrium tests
Flash/no-flash testing
Flexible automated search mode
Ambient to 93OC (5
OC to 93
OC with optional cryostat)
Gas or electric ignition
Easy to clean stainless steel case
Specifications (or equivalent)
Methods (s): ASTM D1310; ASTM D3143
Ambient to 93OC - Variable ramp rate
Electrically driven sweep arm - 500mL bath
Suitable for use with mains gas or portable gas tank
Stainless steel case
Required Accessories:
IP20C Thermometer with certificate of conformity
IP15C Thermometer with certificate of conformity
IP59C Thermometer with certificate of conformity
Flashcheck (pack of 3x80mL)
Multiflash automatic flash point tester – Universal base unit
01
No.
5
Pensky-Martens Closed Cup Flashpoint Tester Highlights of the Equipment
Pensky Martens tester is a standardized measuring instrument
for determining the flash point of volatile liquids with flash
point exceeding 50°C.
This equipment enables to measure the flash point (up to
370°C) of distilled oils (diesel fuel, kerosene), fuel oils,
lubricating oils, etc... The used method is that of closed cup.
Flexible automated search mode
Extended temperature range from ambient to 400°C
temperature range
Gas or electric ignition possible
Useful for independent fire detector
Specifications (or equivalent)
Method(s): ASTM E502; ISO 15267; BIS IS 1448 Part 21; IP 404
(obs); ISO 2719; AASHTO T73-811; NF M07-019; EN 22719; IP
35; BS 2000 Parts 35 & 404 (obs); FTM 791 1102; JIS K2265;
ASTM D93; 1P 34;
Ambient to 370°C temperature range
Variable ramp rate
Two speed stirrer
Forced air cooling facility
Suitable for use with mains gas or gas canister
Required Accessories
Thermometer Ferrule and Adaptor to mount thermometers
Automated temperature Controller
Probe Assembly for Ramp Controller
IP16C Thermometer with Certificate of Conformity
ASTM Thermometer with Certificate of Conformity
IP15C Thermometer with Certificate of Conformity
Calibration & Verification
Multi Test CRM - Diesel Oil 500mL
MTVM - Gas Oil 500mL
Digital Photo Tachometer
01
No.
Page 5 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
6
Abel Flashpoint Tester
Highlights of the Equipment
The equipment enable training about obtaining multiple flash
point data of fuel oils, lubricants
The equipment is suitable for flash point applications of jet
fuels, solvents, chemical etc and provides training to measure
the flammability.
The flash tester provides an increased temperature range of
operation as compared with other testers, allowing greater
flexibility in testing samples according to the Abel test
method.
The unit provides a test range to 110°C and can be extended to
-30°C by any appropriate external chiller.
The flash point tests are simply conducted by mounting the
flash cup filled with sample into the test position and selecting
a pre- or user-programmed test method.
Automation routines provide accurate test results.
Useful for equilibrium tests and non-equilibrium tests
Flash/No-Flash testing
Flexible automated search mode
Ambient to 93°C (5°C to 93°C with optional cryostat)
Gas or electric ignition
Specifications (or equivalent)
Method(s): IP 170; IP 33 (obs); BS 2000 Parts 33 (obs) & 170;
ISO 13736;
Conforms to the design of the 'original' Abel flash point tester
IP 74C and IP 75C thermometers included (IP 170 tests)
Required Accessories
Heater Assembly
Energy Regulator
Electrical Stirrer
IP74F Thermometer with collar for tests to IP 33 (pack of 2)
IP2F Thermometer with collar for tests to IP 33 (pack of 2)
IP75F Thermometer with collar for water bath (pack of 2)
Calibration & Verification
MTVM - Kerosine 500mL
01
No.
7
Semi-Automatic Cleveland Open Cup Flash Point
Tester
01
No.
Highlights of the Equipment
The automated Cleveland Open Cup flash point tester
accurately determines flash and fire point temperatures of
viscous petroleum products including oils and bitumens over
an extended temperature range. The flash/fire point tests are simply conducted by mounting the flash
cup filled with sample into the test position and selecting a pre-
programmed test method or the search mode to determine an
approximate flash point.
The test results are automatically corrected to standard
pressure (101.3 kPa). Equipped with a differential Pt-100 RTD probe, the system is designed to
duplicate the response time of a mercury-in-glass thermometer.
Flash and fire point testing
Flexible automated mode testing
Extended temperature range from ambient to 400°C
Gas or electric flexible ignition option
Automatic sniffer
Specifications (or equivalent)
ASTM D92; IP 36; EN ISO 2592; BS 2000 Parts 36 & 403 (obs);
AASHTO T48; FTM791 1103.7;
Variable temperature rise rate
Electrically driven sweep arm
Page 6 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
Suitable for use with mains gas or Portable Gas Tank
Stainless steel case
Required Accessories
Automated Temperature Controller
Probe Assembly
Calibration & Verification
FLASHCHECK (pack of 3 x 80mL)
8
Smoke Point Apparatus
Highlights of the Equipment
An instrument for determining the smoke point of kerosine and
aviation turbine fuel by measuring the maximum flame height
prior to smoke formation and comparing the results with those
of known standards
Robust construction to provide better training to
untrained/semitrained staff
Clear scale
Specifications (or equivalent)
Method(s): ASTM D1322; IP 57; BS2000 Part 57; ISO 3014;
BIS IS 1448 Part 31; IP 598;
Tripod stand, lamp body and chimney
Viewing window - Robust construction
Required Accessories
Mirror Wick Extraction Apparatus
Wick Trimmer Instrument Case
01
No.
9
Kinematic Viscometer
01
No.
Salient features of equipment
The Kinematic Viscometer is a compact version of the 83542-
0 Kinematic Viscometer, with one temperature-controlled bath
providing capacity for six viscometer tubes and six
simultaneous measurements.
Temperature range 0 to 150°C - Up to 6 viscometer tubes
Integral 6 channel digital timer
In-situ tube cleaning with integral vacuum pump
Specifications (or equivalent)
Method(s): ASTM D7279 Houillon method;
o Compact instrument - One temperature controller bath
Required Accessories
KV Thermometer 40°C Calibration Works
Viscometer Tube Range 3-9
Viscometer Tube Range 6-18
Viscometer Tube Range 10-30
Viscometer Tube Range 20-60
Viscometer Tube Range 60-180
Viscometer Tube Range 100-300
Viscometer Tube Range 200-600
Viscometer Tube Range 600-1200
Viscometer Tube Range 1000-2000
KV Thermometer 50°C Calibration Works
KV Thermometer 100°C Calibration Works
KV Thermometer 150°C Calibration Works
Back-Flush Kit - Pre-Heat and Filtering Unit
Digital Pipette 50 to 250µL
Disposable Tips (pack of 200)
Bath Oil 40°C - 80°C (5 litres)
Viscosity Bath Media Silicone Fluid 120° - 150°C (2 litres)
Bath Oil 80°C - 120°C (5 litres)
Mini Low Temperature Bath Circulator
Calibration & Verification
Thermometer
Page 7 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
10
KV6 Viscometer Bath
01
No.
Salient features of equipment
Accommodates up to 6 viscometer tubes
Temperature range ambient to 150°C
Double wall glass front panel ensures optimum insulation and
reduce heat loss
Low voltage halogen illumination for clear and precise reading
of viscometer tubes
Two positions for reference thermometers
Easy access drain tap fitted at the rear for bath fluid changes
Specifications(or equivalent) Method(s): EN 3104; NF T60-136; JIS K2283; BS 2000 Parts 71
& 319; EN 12595; DIN 51 562; NF T60-100;BIS IS 1448 Part 25;
ASTM D445-IP 71; ASTM D2270-IP 226; BS 188; ASTM D446;
ASTM D2170-IP 319; DIN 51 366; ISO 3105; FTM 791 305;
Accommodates up to 6 viscometer tubes
Temperature range ambient to 150°C, ±1-0.01°C
Digital temperature control with Thermostir Plus Oil, silicone fluid or Water filled depending on temperature of use
Stainless Steel construction
Double wall glass front panel ensures optimum insulation and
reduce heat loss
Integral safety features, including over temperature and low
level fluid cut outs and alarms for high/low temperature
Low voltage halogen illumination for clear and precise reading
of viscometer tubes
Two positions for reference thermometers
Integral cooling coil for connection to cold water supply or
refrigerated chiller optimizes bath stability
Easy access drain tap fitted at the rear for bath fluid changes
CE compliant
Viscosity Ranges 3.0 to 15 , 7.0 to 35 , 100 to 500
Required Accessories
Viscometer Tube Holder for U-tube reverse flow
Viscometer Tube Holder for Ubbelohde& suspended level
kinematic Viscometer, Ubbelohde
kinematic Viscometer, Ubbelohde
kinematic Viscometer, BS/IP/RF
kinematic Viscometer, BS/IP/RF
Viscosity Standard S3
Viscosity Standard S6 COVERS for unused holders in lid to minimise heat loss, pack of 2
IP92C Thermometer with certificate of conformity (C of C)
ASTM Thermometer with certificate of conformity (C of C)
Kinematic Viscosity Thermometer 40°C
Kinematic Viscosity Thermometer 100°C
Viscometer Tube Holder for Cannon Fenske
Calibrated Cannon-Fenskeroutine Viscometers
ASTM D445; D446; IP 71; ISO 3104; 3105
Universal Viscometer Holder
TIME 6-Channel Quartz Timer
Bath Oil 40°C - 80°C (20 litres)
Bath Oil 80°C - 120°C (20 litres)
Silicone Bath Oil 120°C - 150°C (20 litres)
CAPS for sealing space around viscometer limbs
Spirit Level
Bench Viscometer Stand
Digital Stopwatch
Mini Low Temperature Bath Circulator
Page 8 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
11
Viscometer Tube Cleaner
01
No.
Highlights of the Equipment
Cleans up to 6 tubes simultaneously
Heated solvent vapor process
5 to 15 minutes cleaning time
Low solvent loss
Specifications (or equivalent)
Method(s): ASTM D445-IP 71;
Cleaning up to 6 tubes simultaneously
Heated solvent vapour process
5 to 15 minutes cleaning time
Low solvent loss
12
Viscometer Tubes
01
No.
Specifications (or equivalent)
Calibrated U-Tube Viscometers
BS 188 Type BS/U
With constant and certificate of calibration
For transparent liquids requiring 13 to 40mL of sample
Viscosity Range (mm2/s)
0.3 to 1.0 , 0.9 to 3.0 , 2.0 to 10 , 6.0 to 30 , 20 to 100 ,
60 to 300 , 200 to 1000 , 600 to 3000 , 2000 to 10000
13
Calibrated U-Tube Reverse Flow Viscometers
01
No.
Highlights of the Equipment
With constant and certificate of calibration. For transport and
opaque liquids containing requiring a sample of 12 to 25 mL.
Specifications (or equivalent)
BS 188 Type BS/IP/RF
Viscosity Range (mm2/s)
0.6 to 3.0 , 2.0 to 10 , 6.0 to 30 , 20to 100 , 60 to 300
200 to 1000 , 600 to 3000 , 2000 to 10000 ,
6000 to 30000 , 20000 to 100 000 , 60 000 to 300 000
14
Calibrated Cannon-Fenske Routine Viscometers
01
No.
Highlights of the Equipment
With constant and certificate of calibration (calibration data at
40°C with the constant stated at 40°C and 100°C). For
transparent liquids requiring approximately 7mL of sample.
Specifications (or equivalent)
Method(s) : ASTM D445; D446; IP 71; ISO 3104; 3105
With constant and certificate of calibration. For transparent
liquids requiring approximately 7mL of sample.
Viscosity Range (mm2/s)
0.5 to 2.0 , 0.8 to 4.0 , 1.6 to 8.0 , 3.0 to 15 , 7.0 to 35 ,
20 to 100 , 50 to 250 , 100 to 500 , 240 to 1 200 ,
500 to 2 500 , 1 600 to 8 000 , 4 000 to 20 000
15
Calibrated Cannon-Fenske Opaque Viscometers
01
No.
Highlights of the Equipment
With constant and certificate of calibration (calibration data at
40°C with the constant stated at 40°C and 100°C). For
transparent and opaque liquids requiring approximately 12mL
of sample.
Specifications (or equivalent)
ASTM D445; D446; IP 71; ISO 3104; 3105
Viscosity Range (mm2/s)
0.5 to 2.0 , 0.8 to 4.0 , 1.6 to 8.0 , 3.0 to 15
7.0 to 35 , 20 to 100 , 50 to 250 , 100 to 500
240 to 1 200 , 500 to2 500 , 1 600 to 8 000
4 000 to 20 000
Page 9 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
16
Calibrated Zeitfuchs Cross-Arm Viscometers
01
No.
Highlights of the Equipment
With constant and certificate of calibration. For transparent
and opaque liquids requiring a sample of up to 3mL
Specifications (or equivalent)
Method(s): ASTM D445; D446; IP 71; ISO 3104; 3105
With constant and certificate of calibration. For transparent and
opaque liquids, requiring 3mL of sample.
Viscosity Range (mm2/s)
0.6 to 3.0, 2. 0 to 10 , 6.0 to 30 , 20 to 100 , 60 to 300
200 to 1 000 , 2600 to 3 000 , 2 000 to 10 000
6 000 to 30 000 , 20 000 to 100 000
17
Calibrated Ubbelohde Viscometers
01
No.
Highlights of the Equipment
With constant and certificate of calibration for transparent
liquids requiring 18mL of sample.
Specifications (or equivalent)
Method(s): ASTM D445; D446; IP 71; ISO 3104; 3105
With constant and certificate of calibration. For transparent
liquids requiring 18mL of sample.
Viscosity Range (mm2/s)
0.3 to 1 , 0.6 to 3 , 1 to 5 , 2 to 10 , 6 to 30 , 10 to 50
20 to 100 , 60 to 300 , 100 to 500 , 200 to 1 000
600 to 3 000 , 1000 to 5 000 , 2 000 to 10 000
6 000 to 30 000 , 10 000 to 50 000 , 20 000 to 100 000
18
Tri-Gauge Viscosity Comparator
01
No.
Highlights of the Equipment
A transparent perspex block with three tubes and ball testers
that allows a simple comparison of a sample to reference oils
of higher and lower viscosity.
Specifications (or equivalent)
Ideal for In-Service lubricant oil testing
Rapid and easy Go / No-Go viscosity test
Quick and easy comparison of approximate relative viscosity
10mL sample and reference oil size
Suitable for clear and opaque liquids
Engraved scale
19
Saybolt-Redwood Viscometer Bath
01
No.
Highlights of the Equipment The Saybolt-Redwood Viscometer Bath is an oil filled bath designed to
heat two sample filled viscometer cups and then maintain them at a
constant temperature while the flow time is measured.
Specifications (or equivalent)
Method(s): BS 434; ASTM D88; ASTM E102; IP 70 (obs);
AASHTO T72; FTM 791 304;
2 cup capacity
For use with Saybolt, Redwood or Bitumen cups
Temperature range ambient to 250°C (482°F)
14 litre oil filled stainless steel bath
1000W heater - Digital temperature controller Thermostir unit with fine temperature control adjustment (0.1 °C range) Cooling coil - Cup Adaptors
Required Accessories
Bath oil 40 - 80°C (20 litres)
Bath oil 80 - 120°C (20 litres)
Digital Stopwatch
Silicone Bath Oil 120 - 150°C (20 litres)
Saybolt Viscosity Kit (ASTM D88)
Redwood No. 1 Viscosity Kit (IP 70)
Redwood No. 2 Viscosity Kit (IP 70, BS 434)
Page 10 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
20
Viscosity Standards
01
No.
Highlights of the Equipment
Viscosity standards are exactly equivalent to, and interchangeable
with, other recognized Viscosity standards which adopt the
standard reference number as specified in many international test
methods and often referred to for calibration requirements.
Specifications (or equivalent) i. Viscosity Standard S3 ii. Viscosity Standard D10
iii. Viscosity Standard S20 iv. Viscosity Standard N35
v. Viscosity Standard N100 vi. Viscosity Standard S200
vii. Viscosity Standard N350 viii. Viscosity Standard S6
ix. Viscosity Standard S60 x. Viscosity Standard S600
xi. Viscosity Standard S2000
xii. Viscosity Standard S8000
xiii. Viscosity Standard N15000
xiv. Viscosity Standard N 1000
xv. Viscosity Standard N4000
xvi. Viscosity Standard S30000
21
Cloud And Pour Point Cryostat
01
No.
Highlights of the Equipment
The Cloud and Pour Point Cryostat has Four 2 litre
compartments independently temperature controlled. Three
compartments have a temperature range of ambient to -35°C (0
to -35 ±1.5°C).
One low temperature compartment -35 to -51°C (±1.5°C).
Each 2 litre compartment is individually temperature
controlled and can accommodate four Air Wells.
The lid is electrically heated to prevent the formation of ice
and condensation. Refrigeration is accomplished by a two
stage CFC free system. An internal spare canister of R507
refrigerant allows easy recharging of the second stage.
Specifications (or equivalent)
Method(s): ASTM D97-IP15; ASTM D2500-IP 219; EN 23015;
BS 2000 Parts 15 & 219; ISO 3015 ISO 3016; DIN 51 597 (obs);
NF T60-105; FTM 791 201; ASTM D5853-IP 441; JIS K2269 ,
BIS IS 1448 Part 10; BIS IS 1448 Part 110; ASTM D6422;
Four individually temperature controlled compartments
Three compartments ambient to -35°C
one compartment -35°C to -51°C
2litre bath capacity in each compartment
four air wells in each compartment
independent temperature control
two stage 'CFC free' refrigeration system
Heated anti-condensation lid
Required Accessories
IP1C Thermometer with Certificate of Conformity
IP2C Thermometer with Certificate of Conformity
IP63C Thermometer with Certificate of Conformity
Copper Corrosion Test Vessel
Spares
Graduated jar and cork (pack of 10)
Insulating gasket (pack of 20)
Insulating disc (pack of 20)
Compartment Thermometer +20 to -70°C
Cork for jar thermometer well (pack of 10)
Temperature sensor
Calibration & Verification
Multi Test CRM - Diesel Oil, 500mL
MTVM- Gas Oil 500mL
MTVM - Fuel Oil 500mL
Page 11 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
22
Grease Drop Point Oven
01
No.
Highlights of the Equipment
The Grease Drop Point Oven is heated by an integral 775W
temperature controlled cartridge heater. The oven contains six
apertures to receive 11740-0 grease cups and support
assemblies.
Specifications (or equivalent)
Method(s) ASTM D2265; ISO 6299;
Aluminum solid block oven
Six test apertures
Temperature range 120 to 345°C
Illuminated chambers
Accessories
Grease Cup and Support Assembly
Thermometer Depth Gauge
IP73C Thermometer with Certificate of Conformity
IP73F Thermometer with Certificate of Conformity
Calibration & Verification
Cup Plug Gauge
Go-Not-Go Cup Gauge
23
Penetrometer
01
No.
Highlights of the Equipment
A manual penetrometer with a range of 0 to 640mm (64 Pen).
Specifications (or equivalent)
Method(s): ASTM D1831; ASTM D5; ASTM D217; ASTM
D937; ASTM D1321; ASTM D1403; ASTM D2884; IP 49; IP
50; IP 179; IP 310; IP 376; BS 1377; BS 2499 Part 3; BS 2000
Parts 49, 50 & 179; ISO 2137; ASTM D7342; EN 1426;
Microprocessor controlled
Penetration range 0 to 630 Pen (63mm)
Timer range 1 to 9999 second
Automatic plunger release and retention
Flexi light
RS232C interface
Required Accessories
ASTM D5 Kit
Water Bath
Calibration & Verification
Penetrometer Calibration Kit
MTVM - Bitumen 200mL
24
Auto Oxidation Stability Bath
01
No.
Highlights of the Equipment
The Oxidation Stability Console Bath measures the induction
period for oxygen in gasoline, and allows the weight of gum
and residue in aviation fuel to be determined by direct
weighing.
The Oxidation Stability Console Bath comprises a heated
water bath with reflux condenser, a cold water plunge tank for
cooling test vessels after each test, and an integral system for
charging oxidation vessels prior to test.
The Auto-Oxi Control system provides automatic monitoring
of up to 4 pressure test vessels. High quality pressure
transducers and system components ensure reliable operation
and fully traceable results.
Specifications (or equivalent)
Method(s): ASTM D873; BS 2000 Parts 40 & 138; NF M07-012;
NF M07-013; ISO 7536; FTM 791 3352; FTM 791 3354; JIS
K2287; IP 138; IP 40; ASTM D525; EN 7536; BIS IS 1448 Part
147; BIS IS 1448 Part 28;
Operating temperature 100°C
4 test stations
Page 12 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
Cold-Plunge bath
Optional automatic pressure monitoring
Integral vessel charge system
Constant level device
Automatic pressure recording options
Required Accessories
Charging lead - low pressure
Oxidation Vessel
Vessel Bench Clamp & Holder
Spanner
Liner with cover (pack of 3)
IP24C Thermometer with Certificate of Conformity
Transducerc/w Lead
Calibration Plug
Oxygen Charging and Purging Kit
Pressure Gauge
Pressure Transmitting Capillary
Water Purifier
Automatic Oxidation Control Unit
25
Oxidation Bath With Oxflo Controller
01
No.
Highlights of the Equipment
The Oxidation Bath is used for quantative analysis of the
tendency of oils and fuels to form sludge, acids and deposits when
exposed to oxygen in the presence of metallic catalysts over
extended periods.
Specifications (or equivalent)
Method(s): ASTM D943; ASTM D2274-IP 388; ASTM D4310;
IP 157: ISO 4263; ISO 12205; BS 2000 Part 388;
Ambient +5°C to 100°C temperature range
6 position oil bath
Reliable digital thermostir unit
Oxflo Controller and flowmeters included
Low liquid protection
Over temperature cut out
Required Accessories
Silicone Carbide Paper 100 grit (pack of 50)
Set Glassware ASTM D2274
Sample Filtering Kit for D2274
Steel Catalyst Wire in 3 metre lengths (pack of 6)
Pre-formed Copper and Steel Catalyst Coil (pack of 6)
Copper Catalyst Wire in 3 metre lengths (pack of 6)
Accessory Pack ASTM D943
Thermometer for. ASTM D943
Laboratory Drying Oven
IP80C Thermometer with Certificate of Conformity
Hot Heater 1000W
Analytical Balance
Bath oil 8O - 120°C (20 litres)
26
Oxi-Cor Bath
01
No.
Highlights of the Equipment
A stainless steel water or oil bath with a temperature range of
ambient ±5°C to 150°C, temperature controlled to ±0.1°C by a
top mounted thermo stir circulator with integral over-temperature
and low fluid level protection devices.
Specifications (or equivalent)
Method(s)ASTM D4048; ASTM D4814; IP 227 (obs); ASTM
D873; ISO 7536; ASTM D5304 ; IP 112; ASTM D130; EN 2160;
BS 2000 Parts 40, 112, 138 & 154; IP 154; IP 138; IP 40 ASTM
D525;
Ambient +5°C to 150°C temperature range
Page 13 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
4 test stations (3 when used for Oxidation tests)
Copper/Silver Corrosion and Oxidation tests
Optional AUTO-OXI Automatic Pressure Monitoring System
Required Accessories
Spanner
Silicon Carbide Paper 150 grit (pack of 50)
Support Assembly (pair)
Glassware Silver Corrosion
Silver Test Strip (pack of 5)
ASTM Colour Standard
Silicon Carbide Cloth 240 grit (pack of 50)
Silicon Carbide Paper 220 grit (pack of 50)
Silicon Carbide Paper 100 grit (pack of 50)
Silicon Carbide Grains 150 grit 500g (pack of 5)
Glass Support Cradle (pack of 3)
Pressure Test Vessel
Silver Corrosion Kit
Tongs
Silver Corrosion Test Kit for Gasoline - ASTM D7671
Test Tube Ejector Spring (one per tube)
Multi-Strip Vice
Copper Test Strip (pack of 30)
Flat Glass Test Tube (pack of 10)
ASTM -IP Copper Strip Corrosion Standard
Test Tube (pack of 10)
Digital Stopwatch
Silicone Bath Oil 120°C - 150°C (20 litres)
Bath Oil 40°C - 80°C (20 litres)
bath Oil 80°C - 120°C (20 litres)
AutoOxi Control System
Transducer complete with lead
Charging lead - low pressure
Oxidation Vessel
Vessel Bench Clamp & Holder
Liner with cover (pack of 3)
Water Purifier
IP64C Thermometer with Certificate of Conformity
IP64F Thermometer with Certificate of Conformity
IP24C Thermometer with Certificate of Conformity
IP63C Thermometer with Certificate of Conformity
27
Oil Test Centrifuge
01
No.
Highlights of the Equipment
This purpose-made Oil Test Centrifuge is fully programmable
allowing automatic configuration to the specified oil test
parameters. A four-place swing out rotor and universal bucket
assembly accommodates low cost adaptors and cushions suitable
for borosilicate glass centrifuge tubes of the types specified for oil
testing: 6 or 8-inch conical8-inch trace sediment, 8 inch pear-
shaped or 12.5mL. To reduce errors in measurement of tube
content, the rotor design allows tubes to stand in a near upright
(vertical) position at rest.
Specifications (or equivalent)
Method(s): ASTM D91; ASTM D96 (obs); ASTM D893; ASTM
D1290; ASTM D1796; ASTMD1966; ASTM D2273; ASTM
D2709; ASTM D2711; ASTM D4007; IP 75 (obs); IP 359; BS
2882 (obs); API 2542; API 2548; ISO 3734; DIN 51 793; NF
M07-020; ISO 9030;FTM 791; Methods 3000; 3003; 3004; 3101;
3121; 5661; ASTM D5546;
Conforms to safety requirements IEC 1010-1; 1010-2-D
Page 14 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
4 place swing out rotor
specifically designed for testing oils
Static , near vertical bucket positioning
Heated chamber, ambient to 80°C
Membrane 'touch' control panel Pre-heat facility to ensure bowl is at test temperature prior to test
Universal buckets for 12.5mL, 6 and 8 inch glassware
Optional Hazard Reduction System
Microprocessor control with 99 memories
Optional trolley
Required Accessories
Bucket adaptor for 90040-0 & 90060-0 (pack of 4)
Tube 8 inch x 100mL cone-shaped (pack of 6)
Hazard reduction System
Bucket Adaptor for 90050-0 (pack of 4)
Bucket Adaptor for 90011-0 Tube (pack of 4)
Transformer for 220V 60Hz operation
Tube 6inch x 100mL cone-shaped (pack of 6)
Tube 8inch x 100mL pear-shaped (pack of 6)
Tube 100mL trace-sediment (pack of 6)
Rack, holds 5 x 90011-0 tubes
Rack, Holds 6 x 90040-0 or 90060-0 tubes
Rack, Holds 4 x 90050-0 tubes
Stoppers (pack of 50)
Block Heater
Adopter for 90012-0 Centrifuge Tube (pack of 4)
Centrifuge Tube 12.5mL (pack of 6)
Block 90040 -0/90060-0
28
Dew-Point Apparatus
01
No.
Highlights of the Equipment
To determine the vapour content of fuels by measuring the
dew point. The sample enters a stainless steel chamber and
passes across a stainless steel mirror cooled by refrigerant.
The temperature at which water vapour starts to condense on
the mirror is indicated by athermometer, viewed through a
pressure-resisting window.
Specifications (or equivalent)
Method (s): ASTM D1142;
To determine the vapour content of fuels by measuring the
dew point
Bureau of Mines type
Accuracy ±0.1°C
Required Accessories
- Pressure Gauge - Oxygen Gauge 0 to 8.3bar
- Pressure Gauge 0-4 bar - Pressure Gauge 0-40 bar
- Pressure Gauge 0-70 bar - Pressure Gauge 0-140 bar
- Tripod with adjustable legs - Thermometer 0 to 100°F
- Thermometer -40 to +250°F - Thermometer -40 to +460°F
29
H2S Analyzer
01
No.
Highlights of the Equipment
The H2S Analyser is an excellent tool for supporting product
Quality Control and safety; ensuring product is within
approved specification. It is also ideal for both product
remediation treatment of feedstock components and off-spec
products with fast repeat sample measurement capability.
IP 570/12a, procedure A includes the Vapour Phase Processor
(VPP) accessory, which provides the marine industry with a
more robust specification tool for monitoring H2S. This is
achieved by removing any interfering chemicals such as
Page 15 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
toluene, xylene or Mercaptans, which can damage the sensor
and 'interfere' with readings. Additionally the VPP can be
used to address a broader range of petroleum products.
The H2S Analyser combined with the VPP offers a fast and
robust means of determining H2S levels to ensure efficient
treatment of Crudes. The instrument provides a costeffective
alternative to traditional methods which cannot offer a true
indication of H2S at low gas levels.
Specifications (or equivalent)
H2S Analyzer range: 0-250 mg/kgH2S in the liquid phase (0-
250 ppm H2S)
Viscosity range: Up to 3000 mm2/s
Principle of measurement: Advanced Electrochemical sensor
Test duration: 25 minutes with VPP
Sample size: 1mL, 2mL, 5mL (depending on H2S
concentration)
Diluent Volume 20mL
H2S vapour Phase Processor (VPP)
VPP accessory for use with the H2S Analyzer to improve
precision and accuracy of IP 570- ASTM D7621 by eliminating
the effects of chemicals such as toluene, xylene or Mercaptans
which can damage the sensor and 'interfere' with readings
Consumables Test Kit
30
Portable Flowmeter
01
No.
Highlights of the Equipment
An in-line flow meter with an advanced straight sensor tube
and restrictor flow element to give a high degree of accuracy.
Specifications (or equivalent)
0 to 200 mL/min
±1.5% accuracy
Oxygen or air
Tilting display
31
Manometer Digital
01
No.
Highlights of the Equipment
Portable, handheld instrument for calibration of gauges and
apparatus. The large LCD screen shows readings in kPa or
equivalent units of measurement can be selected. Calibration and cross-check of vacuum measuring instruments
Accurate in-situ checks for vacuum performance.
Specifications (or equivalent)
Range: 0 to100kPa
Accuracy :0.25% Full Scale
Power Supply: 9 volt PP3 battery (supplied)
Size:( HxWxD): 14 x 7 x 2.5cm
32
Hot Stir
01
No.
Specifications (or equivalent)
Temperature range: 5 to 550°C(41 to 1022°F)
Stir Range: 60-1150 rpm
Top material Pyroceram Glass Ceramic
Top size: 10.8 x 19.7 x 28 cm
Voltage: 200/240V, 50Hz
Power: 698W Stirrer Bar (5)
Stirrer Rotor
33
Digital Calibration Thermometer
01
No.
Specifications (or equivalent)
High precision, portable temperature measurement
Wide temperature range of -40OCto +150
OC
Calibrated for use at 37.8OC (100
OF)
Designed specifically for verification of temperatures
associated with vapour pressure tests at 37.8oC (100
oF).
Page 16 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
34
Portable Density Measurement Kit
01
No.
Specifications (or equivalent)
0 to 3g/cm3 range
Single hand operation
Density and SG measurements
Explosion-proof - Ex II 2 G EExib IIC T4
Petrol and organic solvent resistant
Automatic temperature compensation
Density standards included in the kit
35
Octane / Cetane Analyzer
01
No.
Highlights of the Equipment
Bench top operation
Fully automated measurement
Very small sample volumes (approx 40 mL/analysis including
flushing)
Short analysis time of approximately 20 minutes per sample
Integral 20 place carousel and auto sampler
Minimum operator time Precise and reproducible software-controlled determination of CN(cv)
Calibration with industry approved PRFs
Excellent correlation to EN ISO 5165 & ASTM D613
Advanced electronically controlled high pressure fuel
injection system
Safe operation -- integral safety monitoring functions
Results saved to PC or for download
Proven calibration stability — minimizing downtime
Specifications (or equivalent)
Function Quantitative constituent analysis for product research
measurement and/or product monitoring
System Capabilities
Precalibraed for: Octane number RON, MON, (R+M)/2
Optional Calibrations: Diesel cetane index, cetane number
Outputs: LCD display, built-in printer
Data Transfer: Via RS-232 port for interface with PC
Data Anaylsis: Includes full calibration software
Results: Traceable to CFR Engine or other fuel lab standards
Calibrations : Stores up to 10 calibration sets
Data Storage: Stores data for up to 25 samples
Optical Capabilities
Measurement Mode: Diffuse transmittance Spectrum Range: 14 filters covering wavelengths from 893 to 1045 nm
Scan speed: Up to 10 scans per second
Optical range: 0 to 6 AU
Resolution: 0.00001 AU
Stability: 0.05 Mili-AU
Measurement Time: Variable (Typically under 20 seconds)
Sampleinformation Sample size: 200mL with 75 mm path length
SampleHolder: Reusable glass with chemical seal cover
Sample Preparation: None required
Sample Destruction: None
Physical Data
Dimensions: 12 cm X 36 cm X 11 cm
Weight:3 lbs (less than 2 kg)
Installation Data AC Power Requirements: 240 VAC 50/60 Hz AC adapter (supplied)
DC Power Requirements: 6 AA alkaline batteries (included)
optional 12V automobile adapter Power consumption: 750 ma
Page 17 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
36
Water Still Merit
01
No.
Specifications (or equivalent)
Output 4 liters/hour single distilled with bench/wall mounting
stand. Overall 500 x 150 x 450mm high. For 240V 50/60Hz
single phase supplies. Rating 3kW.
Long life metal sheathed heater Safety thermostat protects still in the event of water supply failure
Pyrex glass boiler and double coil condenser
Plumbing connections via screwthread connectors
Can be descaled without dismantling
Bench or wall mounting
Water consumption 60 litres/hour
Pyrogen free (output must be tested)
Distillate quality: Conductivity 3 to 4µS/cm / pH 5 to 6.5
37
Junkers Gas Calorimeter
01
No.
Specifications (or equivalent)
A self-contained steady flow gas calorimeter, complete with
highly insulated, Combustion chamber/water heat exchanger
A constant head, controlled water flow with flow
measurement, together with a wet type gas flowmeter and
pressure regulating device. All relevant thermometers and wet type gas flow meter must be supplied
Spares for at least 2 years normal teaching operation must be supplied
Two year warranty
Dimensions
Height: 300cm Depth: 250cm Width: 250cm Weight: 25kg.
38
Boys Gas Calorimeter
01
No.
Specifications (or equivalent)
Boys Gas Calorimeter Set comprising calorimeter.
Wet type
Hyde pattern precision gas meter fitted with spirit level
Point-setting key and height gauge
A constant-head overhead funnel with water collecting tubes
2 thermometers engraved 0-50°C and 0-75°C for inlet and
outlet water temperatures
2thermometers engraved 0-50°C (-5 to 105°C for tropical
climates) for water temperatures
2 thermometers engraved 0-35°C (0-50°C for tropical
climates) for Ambient temperatures
2 Adjustable reading lenses
A graduated glass vessel 2,400 mL capacity
A graduated glass vessel 50 mL capacity
A gas Control valve
A cylindrical metal vessel and a 4 burner set covering
propane (25000 BTU/ft3, 93.1 MJ/m
3)
Butane and air/propane mixture (600-900 BTU/ft3, 22.3-33.5 MJ/m3)
Natural gas and methane (900-1200 BTU/ft3, 33.5-44.7
MJ/m3) and propane, acetylene, ethylene/propane mixture
(1200-3500 BTU/ft3, 44.7-130 MJ/m
3).
39
Gaussmeter
01
No.
Specifications (or equivalent)
Axis: 3
Range: 0-250 mG, 0-25.0 microT
Resolution: 0.01 mG, 0.1 microT
Frequency: 15-5500 Hz
Accuracy: ±½dB 30 to 5000 Hz
Selectable axis (3D, X, Y, Z) on ALL features
Peak Axis (which axis has the strongest field)
On-Screen Graphing (Horizontal bargraph of field strength)
Max Hold
Variable Brightness Blue LED Backlight
Page 18 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
Selectable units: milliGauss or microTesla
Fast Update Rate: 2.5 times per second
Low battery indicator
Flat frequency response
±½dB 30 to 5000 Hz
-3dB 15 to 5500 Hz
40
Ambient Air Analyzer
01
No.
Specifications (or equivalent)
Method of Detection: O2, CO2, SO2, NO, NO2, HCl, Cl2, NH3,
and H2S by electrochemicalsensor, % RH by capacitive polymer,
CO2 by infrared sensor, combustibles by catalytic sensor
Resolution: 0.1% on %O2, 1ppm on ppm gases
Accuracy and Repeatability: ±2% of full scale
Drift Less than 1% of full scale or 2 ppm per 8 hours,
whichever is greater, with constant ambient temperature
Response Time (T-90): varies with individual sensor but
generally under 2 minutes for full reading
Ambient Temperature Range: 400 to 120°F (4 to 49°C)
Linearity: Better than ±2% of full scale
Size and Weight: 15"W x 7" H x 12" D
Power:220 VAC 60 Hz for recharging
Output Options: 4-20mA or 0-1 VDC, built-in printer,
detachable data logger
Alarms: low battery and low flow alarms are standard,
audible and visual alarms per gas
41
Total Organic Carbon (TOC)Analyzer
01
No.
Specifications (or equivalent)
Includes:
Computer, Printer and HTaccess Windows, software
Cable set
instruction manual
Spare partkit (2CA16450), which consists of: grease, (pump)-
tubing, TC tube, and TC catalyst, pinner, sample needle, 0-
rings and sealings, quartz wool filling, fuses
CO2SCRUBBER for removal of CO2 from Carrier
Air Cylinder & Regulator Consumables and spare parts required for the analysis of 5000 samples
Glass sample tube 15 mL. for auto-sampler (250 pcs)
Grease for pump decks (50 mL)
Pump tubing 2 color bridges, black-orange (8 pcs)
Tubing PTFE 1.6x6.3mm IDx0D (1 meter)
Polyethene tubing 1.5 mm ID (15 meter)
O-ring/sealing kit for Injection-ports consisting of: (1 set)
Sealing ring small PTFE (4 pcs.)
O-ring precise Silicone70, 9.3x2.4mm (4pcs.) Sealing ring large PTFE (4 pcs.)
O-ring precise Silicone70, 37.8x1.78 (4pcs.)
O-ring 1.8 x 1.78 mm Viton (10 pcs.)
O-ring 0.74 x 1.02 mm Viton (10 pcs.)
O-ring, 21.3 x 2.4 Viton (4 pcs.)
Gasket PTFE 18.77 x 1.78 (2 pcs.)
42
Wireless Environmental Monitoring System With
Computer And Backup UPS
01
No.
Highlights of the Equipment
Weather-environmental control station: operation and
installation characteristics
Sensors: operation and positioning characteristics
Mechanical and electrical installation techniques
Data transmission: software installation, station preparation
Page 19 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
Specifications (or equivalent) Wireless weather station, with radio range up to 300 m and
integrated sensor block, including supporting pole (1.77 m) and
related mounting tripod. 1 console with graphical display, assembly
base allowing both tabletop or wall use, power supply included
Sensors for the acquisition of environmental and weather parameters Pressure: range from 880 to 1080 mbar, resolution of 0.1 mbar
Inner/outer relative humidity: range from 0 to 100%, resolution of 1% Outer temp. range from -40 to +65°C, resolution of 1°C
Inner temperature: range from 0 to 60°C, resolution of 1°C
Wind speed: range from 1 to 67 m/s, resolution of 0.1 m/s
Wind direction: from 0 to 360°, resolution of 1°
Rain: range from 0 to 19999 mm, resolution of 0.2 mm Solar radiation: range from 0 to 1800 W/m
2, resolution of 1 W/m
2
Data transmission via radio every 2.5 seconds. The console
enables to display not only the instantaneous measure of the
parameters mentioned above, but also the following ones:
Heat index Minimum and maximum external/internal humidity, with time and date
Weather forecasts with graphical symbols
Lunar phase and solar phase Minimum and maximum external temperature with time and date
Maximum wind speed with date and time Minimum and maximum values of external humidity, with time and date
Dew point
1 data logger with USB interface The data acquisition and processing software for Windows to:
Display the weather actual conditions
Plot daily, weekly or yearly diagrams
Display different parameters, at the same time, to analyze any
correlation among them.
43
Dual Beam 8 Cell Scanning Spectrophotometer
With Computer And Backup UPS
01
No.
Specifications (or equivalent)
Optical System: Dual beam
Wavelength range: 190nm-1100nm
Spectral bandwidth: 2.0nm
Stray Light: 0.2%T (220nm and 340nm)
Wavelength accuracy: 0.5nm (with automatic wavelength correction)
reproducibility: 0.2nm
Photometric Range: -0.3~3.0 Abs (0~200%T)
Photometric Accuracy: 0.002Abs (0~0.5Abs), 0-0.004Abs
(0.5~1.0Abs) 0.3%T (0~100%T)
Accessories:
8 Auto Cell Holder 8 Optical Glass Cell 10 mm
2 Quartz Cell 10 mm 1 Cable
1 Software and Cable 1 Dust Cover
1 instruction Manual
44
Electronic Balance
01
No.
Specifications (or equivalent)
Capacity: 400 grams
Readability: 0.001 gram
Power: AC Adapter: 200,240 VAC 50/60 Hz
45
Volumetric Titrator
01
No.
Specifications (or equivalent)
Polarized sensor input
measurement range: -2000...+2000 mV
resolution / Limits of error: 0.1 mV / 2 mV
Polarization current range: 0...24 µA
polarization current resolution / Limits of error: 0.1µA / 1 µA
Page 20 of 28
Sr.
No.
ITEMS DESCRIPTIONS Qty. Brand,
Make &
Model
Unit Price
(C&F Basis)
Total Price
(C&F Basis) Minimum Required Specifications
Burette drive Drive resolution: 20'000 steps
Burette resolution (for 5 mL burette): 0.25 µL
Limits of error: 0.3% of the respective volume
Resolver: 32 pulses / mm stroke
Resolver resolution: 0.0625% of burette volume
Filling time and discharge time: 20 s at 100% filling rate
Environment
Ambient temperature: +5...+40oC
Atmospheric humidity max.: 80% at 31oC
Titrator dimensions Width x depth x height / Weight: 210 x 333 x 320 mm / 4.2 kg
Glass beaker: 150 mL
Control and display
Touchscreen: QVGA 5.7" color TFT, 320 x 240 pixel
Application (depends on the environment and handling)
Drift measurement: Online, <5 µg/min
Measurement range: 100 ppm...100%
Repeatability: 0.3% at >10 mg H2O
Warranty: Supplier shall ensure 1 year comprehensive warranty including all parts.
Supplier must quote spares / consumables for 02 years.
Note:
(i) Installation will be the responsibility of the manufacturer or his representative free of cost. However, provision of
electrical switches, gas and water supply will be the responsibility of the University.
(ii) Supplier will also provide training to the faculty members free of cost.
Total Amount / Bid Value
2% Bid Security (Amounting to Rs.1,299,800/-) of the Estimated Price (Amounting to
Rs.64.99 Million) in the form of Demand Draft / Bankers Cheque / CDR Must be
Attached with the Technical Bid:
Evaluation Criteria
Sr.
No.
Parameters Detail Total
Marks
Remarks
1 Past Performance
(Within previous
3 years)
(a) Major Public / Government Institutions
Served (Form A1): (15 marks)
i No. of institutions served 0
ii 1 to 3 5
iii 4 to 6 10
iv 7 & Above 15
(b) Major Private Institutions Served:
(Form A2) (05 marks)
i No. of institutions served 0
ii 1 to 3 2
iii 4 to 6 3
iv 7 & Above 5
20
(15+5)
Public / Government
Institutions mean government
institutions / Public Sector
organizations / Public Sector
Universities / Government
Agencies / Autonomous
Bodies etc.
Private Institutions referred to
other than above.
2 Market experience
in quoted items
i 1 year 2
ii 2 years 4
iii Above 2 years 5
Copy of Delivery Challan duly signed by the
concerned customer / bill of entry etc. must be
provided
5 Experience will be confirmed
from the date of supplies made
/ delivered against the purchase
order.
3 Length of
Dealership
i Above 4 years 5
ii 3 – 4years 4
5 Length of dealership with the
quoted principal will be
considered. Documentary
Page 21 of 28
iii 2 – 3 years 3
iv 1 – 2 years 2
v Below 1 year 0
Evidence beattached.
4 Financial Status
i Tax Returns (Last 3
years)(2 marks each year)
6
ii Bank Certificate* 4 iii Bank Statement
(Previous 12 months) 10
(a) Balance above 50 Million 10
(b) Balance 40.1 to 50 Million 08
(c) Balance 30.1 to 40 Million 06
(d) Balance 20.1 to 30 Million 04
(e) Balance 10.1 to 20 Million 02
(f) Balance below 10 Million 0
20 All provided documents can
be verified by the
Department. The marks of
audited balance sheet will be
given in proportion to their
net worth.
* In case of Bank Certificate,
the Bank will certify about
the Bidder’s financial worth,
liquidity status, reputation.
5 Technical Staff
(Overall)
(Form B1)
(Form-B)
i Less than 2 persons 0
ii 2 to 3 persons 05
iii 4 to 5 persons 08
iv More than 5 persons 10
Qualification: Minimum Graduation
Masters qualification
(1 person = 2 marks / 2 person = 4 marks
More than 2 persons – 5 marks )
Training: Foreign Training from principal relating to
the product: 5 marks
(1 person = 2 marks / 2 person = 4 marks
More than 2 persons – 5 marks )
Experience: (1 person equal to or more than 2 years = 02 marks 2 persons equal to or more than 2 years = 04 marks More than 2 persons equal to or more than 2
years = 05 marks
More than 2 persons – 5 marks )
25 Qualification marks will be
awarded on the final
degree. Complete
supporting documents be
attached.
6 Good Reputation
Certificate from any
Govt. Institution /
Private Sector in
Connection with
Services
(Form C1)
i No certificate provided 0
ii 1 to 2 5
iii 3 to 5 10
iv 6 to 7 15
v 8 to 9 20
vi 10 and above 25
Appreciation Certificates / Satisfactory
letters etc. must be attached.
25 Public / Government
Institutions mean government
institutions / Public Sector
organizations / Public Sector
Universities / Government
Agencies / Autonomous
Bodies etc.
Total Marks: 100
Qualifying Marks: 65%
Note: Marks will be awarded only if the comprehensive and complete concerned supporting
documents are enclosed.
The financial bids of technically accepted bidders will be opened publicly at a time to be announced by
the Procuring Agency. The financial bids of the bidders found technically non-responsive shall be
returned un-opened to the respective Bidders.
Page 22 of 28
Form A1
Past Performance – Major Public / Government Institutions Served
Sr.
No.
Contract Name Contract
Value
Brief Description of
the work performed
Name, Address &
Contact No. of the
Client
01
02
03
04
05
06
07
Copies of Contract awarded / Purchase Order must be attached otherwise no marks would be awarded.
Form A2
Past Performance – Major Private Institutions Served
Sr.
No.
Contract Name Contract
Value
Brief Description of
the work performed
Name, Address &
Contact No. of the
Client
01
02
03
04
05
06
07
Copies of Contract awarded / Purchase Order must be attached otherwise no marks would be awarded.
Page 23 of 28
Form B1
List of Technical Staff
Sr.
No.
Name of Employee Certificate/
Diploma/ Higher
Technical
Qualification
Experience Name, Address &
Contact No. of the
Employee
01
02
03
04
05
06
07
08
09
10
Name and Signature of Bidder
With official Stamp
Dated:
Special Note:
1. The required Bid Security must be attached with Technical Bid, otherwise, bid will be rejected.
2. Only the manufacturers or the concerned authorized distributors / whole sellers / dealers / partners / firms of the
concerned manufacturers are eligible to participate in the bid. (Documentary Support must be attached with the
bid).
3. Only one brand / model is allowed to quote against each option. In case, more than one options with different
brands / models have been quoted with different prices against one option, the bid will be rejected as a whole.
4. In case, the firm wants to quote the price on C&F basis, the firm will ensure that Principal is agreed to open LC
with the quoted price in black & white. Subsequently, if, it is communicated by the vendor that the quoted
amount / ordered quantity is lesser and LC cannot be opened with the said amount or ordered quantity (quantity
of the items mentioned in the purchase order as per actual requirement), then, the excuse will not be acceptable
and action will be taken according to the rules which can include forfeiture of bid security or blacklisting or
both of them.
5. Complete supporting documents must be attached with the technical bid according to the requirements
mentioned in the evaluation criteria.
6. The mentioned specifications and the terms & conditions and parameters of the bid documents constitute the
bid evaluation criteria. The financial bids of technically accepted bidders (whose quoted item / model / brand
will be according to the minimum required specifications and who will comply with the terms and conditions of
the bid documents or in case of sample requirement, whose sample will be passed by the technical committee)
will be opened publicly at a time to be announced by the Procuring Agency. The financial bids of the bidders
found technically non-responsive shall be returned un-opened to the respective Bidders.
Page 24 of 28
Note:
1. An Affidavit / Undertaking on Stamp Paper of Rs.20/- (minimum) must be submitted by
the bidder undertaking that:
a) The firm has not been blacklisted in the past on any ground by any Government
(Federal, Provincial), a local body or a public sector organization and no litigation is
underway on account of blacklistment process. In case the bidder has been
disqualified or blacklisted earlier in the past by any public sector organization, detail
concerning the period of such disqualification/ blacklistment, cause of such embargo
and eventual result/ latest status shall be mentioned by the bidder. On account of
submission of false statement or concealment of fact, the Bidder shall be disqualified
forthwith, if contract has not been executed and blacklisted, if the contract has been
executed.
2. 0.25% stamp duty would be furnished by the successful bidder against the amount of the
value of purchase order as levied by the Government after the issuance of purchase order.
3. Financial / Bank Statement for minimum period of 01 year is enclosed.
4. The University shall initially open only the envelopes marked as “TECHNICAL
PROPOSAL” in the presence of Bidders’ representatives who choose to be present, at the
time of bid opening. However, the envelope marked as “FINANCIAL PROPOSAL” shall
remain unopened and shall be retained in safe custody of the University till completion of the
technical evaluation process. Financial Details (Rates of Quoted Items) must not be
mentioned in the technical bid otherwise the bid will be rejected.
5. The over writing / cutting in the rates / specifications etc. is not allowed. In case of over
writing / cutting, the bid for the said item will be rejected or the decision of University will
be final & applicable which will not be challengeable anywhere.
6. Complete brochures / supporting documents of the quoted brands / items must be
enclosed along with the bid document, where applicable.
7. Brand details, Country of Origin and port of shipment must be mentioned in the bidding
documents, if applicable.
8. Technical Specifications must be Equivalent or Higher. Soft copy must be provided in
form of (MS-Word) CD along with bid.
9. Signature & stamp of the bidder is essential at the proper place given at the end of bid
document.
10. Sample of each quoted item must be provided by bidder, if Technical Committee will
demand. In case non-compliance, the bid will be rejected.
11. In case of FOR basis, Prices must be quoted clearly mentioning with all charges/inclusive
of all applicable taxes.
TERMS & CONDITIONS:
1) Bid should be addressed in the name of Treasurer, University of the Punjab and reach in
this office (Procurement Wing) by 31-01-2019 at 09:45 (a.m.).
2) The Tender Opening Committee will open the bids on same date at 10:15 (a.m.) in the
presence of bidders, who wish to attend. In case of bid submission / opening date falls on the
public holiday, the submission / opening date will be next working date.
3) Bid received after due date/time will not be accepted under any circumstances.
Page 25 of 28
4) The bid should be submitted along with 2% Earnest Money Demanded (EMD) of the estimated
price in the form of Demand Draft, Bankers Cheque, or CDR in favor of the Treasurer,
University of the Punjab payable at Lahore to be issued from any enlisted bank with State
Bank of Pakistan. No bid shall be acceptable without EMD. The said EMD of rejected bidder /
bidders will be released after final decision. However, the EMD of successful bidder / bidders
will be retained until the completion of job successfully as per work order. In case of LC, the
2% EMD can be get released after submission of 10% performance security. In case of Rate
Contract, the 2% bid security will be retained until the expiry of contract period.
5) Bid shall remain valid for 90 days from the date of opening the bid.
6) In case of Rate Contract, the Rate Contract shall be placed with only registered / reputed
manufacturers / authorized distributors of foreign manufacturers who are authorized for
supplying the stores, so fresh registration/authorization certificate is required along with bid
subject to the reasonability of rates, company profile, past experience, professional skills,
credibility of the firm etc. However, if some un-authorized firm bearing excellent goodwill,
company profile, past experience, professional skills, credibility of the firm etc. with reasonable
price that can be considered subject to the recommendations of concerned committee.
7) The supply should be executed promptly within delivery period mentioned in Purchase Order.
In case, the firm fails to supply the stores within stipulated period, University of the Punjab
reserves the right not to accept the supply, in part or in full and to claim liquidated damages @
2% per Month (0.06% per day) subject to a maximum of 10% of the total value of stores
ordered.
8) The vendor should ensure that no other Govt. organization is being offered / benefited more
than this discount. If the same is found at any stage recovery will be made accordingly.
9) For any Damages/Shortage during transit, bidder will be responsible & the same must be
replaced within maximum 7 working days.
10) In case the supplies are warranty items, 10% Security of the ordered value will be deducted at
the time of payment or the vendor can himself submit 10% performance security in the form of
CDR / banker’s cheque / bank guarantee having minimum expiry date in accordance with the
warranty period of the items etc. In case of warranty, the amount of Security will be held by the
University till warranty period and the said amount will be released upon the satisfactory report
of end user.
11) The supply will be checked by the Technical Committee / representative of the department, if
so desired.
12) The technical committee shall determine to its satisfaction whether the bidder that is selected as
having submitted the lowest evaluated responsive bid is qualified to perform the Contract
satisfactorily.
13) The determination shall take into account the Bidder’s financial, technical, and production
capabilities. It shall be based upon an examination of the documentary evidence of the Bidder’s
qualifications submitted by the Bidder, as well as such other information as the Technical
Committee / University deems necessary and appropriate.
14) The Technical Committee / University, at any stage of the procurement proceedings, having
credible reasons for or prima facie evidence of any defect in Supplier’s capacities may require
the Suppliers to provide information concerning their professional, technical, financial, legal or
managerial competence.
15) The Technical Committee / University shall disqualify or blacklist a Bidder if it finds, at any
time, that the information submitted by him concerning his qualification as Supplier was false
inaccurate or incomplete, or otherwise to be indulging in corrupt and Fraudulent practices.
Page 26 of 28
16) The Bidder should quote the prices of goods according to the technical specifications. The
specifications of goods, different from the demand of enquiry, shall straightway be rejected.
17) The Bidder is required to offer competitive price. All prices must include relevant taxes and
duties, where applicable. If there is no mention of taxes, the offered / quoted price shall be
considered as inclusive of all prevailing taxes/duties. The benefit of exemption from or
reduction in the GST or other taxes, if granted at any stage of procurement, shall be passed on
to the University.
18) Prices offered should be for the entire quantity demanded; partial quantity offers shall
straightaway be rejected. Conditional offer shall also be considered as non-responsive Bidder.
Where prices are to be quoted in package, all items mentioned in the package shall be quoted in
the offered prices. Non-mentioning of price of each item of the package being non-responsive
shall be rejected straightaway.
19) The Supplier/ agent shall have to produce letter of authorization from Manufacturer and in case
of Manufacturer, documentary proof to the effect that they are the original Manufacturer of the
required goods shall be provided.
20) National Tax Number (NTN), General Sales Tax Number, Professional Tax (if applicable) and
registration certificate with PRA (if applicable) with documentary proof shall have to be
provided by each Bidder in the tender.
21) During evaluation of the bids, the University may, at its discretion, ask the Bidder for a
clarification of its bid. The request for clarification and the response shall be in writing, and no
change in the prices or substance of the bid shall be sought, offered, or permitted.
22) In the financial bids (at the time of opening the financial proposal) the arithmetical errors shall
be rectified on the following basis. If there is a discrepancy between the unit price and the total
price that is obtained by multiplying the unit price and quantity, the unit price shall prevail, and
the total price shall be corrected. If the Bidders/Suppliers do not accept the correction of the
errors, its bid shall be rejected. If there is a discrepancy between words and figures, the amount
in words shall prevail.
23) In case, the blacklistment of the firm is to be pursued, the blacklisting procedure will be
adopted as per PPRA rules.
24) In case the vendor fails to complete the job or provide substandard articles, or withdraw his
offer for any reason, the EMD will be forfeited.
25) The material must be supplied in one lot. Part supplies generally will not be acceptable.
Moreover, the payment will be made after the job has been accomplished in all respects quite in
accordance with the work order. However, in special cases, partial supply / partial payment is
allowed subject to the approval of competent authority.
26) Force majeure clause is acceptable as defined under sales of goods & contract Act.
27) No advance payment will be made in favor of tender awarded firm.
28) Normally the payment will be made within 14 days after receipt of supplies & found in order in
quality and quantity and submission of claim / bill with complete supporting documents.
29) The supplies must be confirmed to the specification of supply order and free of defects in all
respects. If the same is found defective, the same must be replaced immediately free of charge
at University of the Punjab, Lahore.
30) All the disputes under the Rate Contract will be settled by the Main Purchase & Indent
Committee, University of the Punjab and will be binding on vendor.
Page 27 of 28
31) The competent authority reserves the rights to increase or decrease the quantity as per actual
requirement / availability of funds.
32) It is the intention of the authority to make the selection of vendor(s) as fair, transparent
objective and efficient as possible. The Technical Committee will adopt the approach outlined
below to achieve this objective.
(i) Review all quotations to ensure that the minimum technical specifications are met. Any
bid which fails to meet the defined minimum specifications will be disqualified.
(ii) Evaluate the proposed products that are above the minimum requirements. The
evaluation procedure adopted is based on the weighting of all requirements and scoring
the vendor’s responses appropriately.
(iii) Good will / past experience/ history of the firm will be considered while evaluating the
bids.
33) The firm will be bound to provide / ensure quality after sales services during the warranty
period. Otherwise, disciplinary action will be taken under the rules which can include forfeiture
of bid security/ black listing/ disqualification for the participation in any bidding process in
future or both of them.
34) The end user on behalf of the University shall notify the supplier in writing / through telephone
immediately of any defect that occurs during the warranty period. On receipt of such
intimation/notification within the warranty period, the supplier shall attend the emergency /
breakdown call within a maximum of 06 working hours.
35) All the expenses for the above remedial measures including the repair / replacement if so
required shall be born by the supplier. In case the fault has occurred as direct consequence of
undesirable condition i.e. electricity or temperature, the supplier shall inform the buyer for
taking corrective measures prior to the commencement of the remedial activity.
36) Wherever a brand has been specified, equivalent will be entertained subject to technical
evaluation according to PPRA Rules.
37) The rates should be quoted after allowing rebates / discounts, if any but including
transportation, delivery at site, commissioning, packing charges, forwarding and all taxes.
(i) If the supply is taxable, the rate must be quoted Inclusive of all Taxes.
(ii) If the supplies are exempted of taxes, the exemption certificate/ comprehensive
supporting documents must be provided along with the bid.
(iii) If the PST duly imposed by the Govt. of the Punjab is applicable on the quoted job,
then the rate must be quoted after including PST.
38) While quoting the rates of required/specified supplies, its make & made/brand should be
written against each. The rates should be quoted only in Unit / Per Kg. / Per Litter / Pack Each
according to the nature of the quotations / bids.
39) Competent authority / University of the Punjab, has full unchallengeable rights for formal
approval / rejection of bids or overall the purchase case.
40) In case of supply on FOR basis, the supply shall be accepted subject to the condition of final
and unchallengeable approval of the Purchase / Inspection Committee of the University, at the
destination.
Page 28 of 28
41) Prior to the detailed evaluation, the University shall determine the substantial responsiveness of
each bid to the bidding documents. A substantially responsive bid is one, which conforms to all
the terms and conditions & specifications of the bidding documents without material
deviations. Deviations from, or objections or reservations to critical provisions shall be deemed
to be a material deviation for technical proposals. The University’s determination of a bid’s
responsiveness is to be based on the contents of the bid itself without recourse to extrinsic
evidence.
42) If a bid is not substantially responsive, it shall be rejected and will not be accepted/ entertained
for detail evaluation.
43) In case of bid on C&F basis, the University will provide a request letter to concerned tax
authorities for exemption of taxes at the import stage.
44) In case of bid on C&F basis, all bids shall be valid subject to the Performa Invoice in Original
from the Principal duly signed, clearly indicating the name of manufacturer & country of origin
/ port of shipment, along with a certificate from the Principal authorizing the Supplier to bid on
his behalf in case of manufactured goods. Photo copies of the Performa Invoice shall not be
considered. The Supplier should enclose the Principal catalogue/leaflet/literature and other
technical data, if any, along with his bid.
45) The bid amount will be quoted by the vendor along with this certificate:
Assistant Treasurer (Procurement)
I / We have read all the above Bid Document’s instructions and submit
bids/rates in conformity / compliance with the above given terms and
conditions.
_______________________________________
Signature & Stamp of Supplier/Bidder/Vendor
________
Dealing Person Asstt./Deputy Treasurer