ODOFLUX™
Sampling chamber for odors &
volatile chemicals from surface sources
Copyright © 2008 Odotech Inc. Odoflux is a trademark of Odotech Inc.
Odoflux™• Dynamic flux chamber used to
measure emission flow rates per surface unit according to EPA/600/8-86/008 standard.
• For everybody who need to measure odors and volatile chemical compounds flow rates emitted by surface sources:
– Engineer-consultants– Site manager– Inspectors– Scientific researches
An efficient and accepted method for diffuse gas emission sampling.
Sampling chamber on a landfill unloading area
Copyright © 2008 Odotech Inc. Odoflux is a trademark of Odotech Inc.
Area Source Sampling• The Odoflux™ sampling device is used to measure emission flow rates
from various diffusing surfaces (water, soil, waste), which are usually difficult to characterize by traditional means:
– Contaminated soils– Spreading fields– Landfills– Retention, aeration, water treatment pools– Compost windrows– Lagoons– Volatile organic compounds– Odors– Methane– Biogas– Greenhouse gases– Hydrogen sulphide
Soucre sampling: contaminated soil
Copyright © 2008 Odotech Inc. Odoflux is a trademark of Odotech Inc.
Measurements from various diffusing surfacesOdoflux™ has many ports allowing simultaneous monitoring of several parameters. It easily adapts to several configurations depending on analysis needs.
Soucre sampling: soil
Soucre sampling: liquide surface
Copyright © 2008 Odotech Inc. Odoflux is a trademark of Odotech Inc.
Area Source Sampling• The flux chamber consists of a cylindrical enclosure with a spherical top.
The flux chamber is supplied with a controlled flow of ultra pure air from a cylinder (see figure on reverse side). The pure air can also be generated in the field by a filtration system and a compressor. The bag introduced in the lung chamber is connected by a TEFLON© tube to the outlet of the flux chamber. The air is aspirated from the lung chamber using a pump at a controlled flow rate. Due to negative relative pressure, the bag is then filled with gas from the flux chamber.
Processus
A - Compressed ultra pure air (or any neutral gas)B - Odoflux™ flux chamberC - Lung chamberD - TEDLAR© or NALOPHANE© sampling bagE - PumpF - RotameterG - 1/4“ NPT ports for temperature probe, etc.
Copyright © 2008 Odotech Inc. Odoflux is a trademark of Odotech Inc.