odisha state co-operative bank ltd head office ... of link road building...300 mm dia piles 748.00...
TRANSCRIPT
Page 1
Odisha State Co-Operative Bank Ltd
HEAD OFFICE, PANDIT JAWAHARLAL NEHRU MARG
BHUBANESWAR - 751001
ORIGINAL
TENDER DOCUMENT
FOR
PROPOSED CONSTRUCTION OF LINK ROAD BRANCH BUILDING AT -CUTTACK ,
----------------
CIVIL, SANITARY & WATER SUPPLY AND ELECTRICAL WORKS
Volume – II ( Price Bid)
Name of the Tenderer : M/s. ___________________________
Address with contact no. : __________________________
Class of Contractor : ______________________
____________________________
Date of Submission of Tender papers : Up to 2.00 PM on Date 30.03.2016Date of Submission of Tender papers : Up to 2.00 PM on Date 30.03.2016
Date of Opening of Tender : 3.00 PM on Date 30.03.2016
Place of Submission: Odisha State Co-op Bank LTD.
Head Office,
Pandit Jawaharlal Nehru Marg
Bhubaneswar – 751001
TEL:.0674-2375100/167
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 2
AMOUNT
SECTION-1 Rs.
SECTION-2
Rs.
Rs.
Rs.
Rs.
SECTION-3
COST ABSTRACT FOR PROPOSED ODISHA STATE CO-OPERATIVE BANK, LINK ROAD BRANCH OVER
PLOT NO-1027, MOUZA CUTTACK TOWN, UNIT NO-33,
AT- CUTTACK
DESCRIPTION
CIVIL WORKS
(BUILDING PORTION)
INTERNAL & EXTERNAL
SANITARY WORKS
A )SANITARY
INSTALLATIONS
B)WATER SUPPLY
C)SEWERAGE
D )TUBE WELL & RAIN
WATER HARVESTING
SITE DEVELOPMENT
Rs.
Rs.
Rs.
Rs.
SECTION-4 Rs.
SECTION-5
Rs.
Rs.
Rs.TOTAL
A ) C.C ROAD
B) SURFACE DRAIN
C) BOUNDRY WALL
D) CROSS DRAINAGE
WORK WITH COW
CATCHER
FIRE FIGHTING
ELECTRICAL
A)INTERNAL
ELECTRICAL
B)OUT SIDE SOLAR
STREET LIGHT
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 3
CIVIL WORKS (BUILDING PORTION)
Sl
noBOQ DESCRIPTION QTY UNIT RATE IN FIGURES AMOUNT
EARTH WORK
1
All kinds of soil
497.77 sqm
RATE IN WORDS
2
SECTION-1
DETAIL TENDER BOQ OF PROPOSED ODISHA STATE CO-OPERATIVE BANK, LINK ROAD BRANCH OVER
PLOT NO-1027, MOUZA CUTTACK TOWN, UNIT NO-33,
AT- CUTTACK
Surface dressing of the ground including removing vegetation and inequalities not
exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and
saplings of girth upto 30 cm measured at a height of 1m above ground level and removal
of rubbish upto a distance of 50 m outside the periphery of the area cleared etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant.
497.77 sqm
RATE IN WORDS
3
497.77 sqm
RATE IN WORDS
4
All kinds of soil.38.616 cum
RATE IN WORDS
PILE WORK
Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery
of the area cleared etc complete including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m
etc complete including supply & transportation of materials from the source to the work
site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 4
5
300 mm dia piles748.00 Mtr
RATE IN WORDS
6
176.00 Each
RATE IN WORDS
7
Boring, Providing and installing cast in situ Bore compaction under reamed piles of
specified diameter and length below pile cap in M-25 cement concrete, to carry a safe
working load not less than specified, excluding the cost of steel reinforcement but
including the cost of boring with bentonite solution and the length of the pile to be
embedded in pile cap etc. all complete. (Length of pile for payment shall be measured
upto to the bottom of pile cap) :etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant
Extra for providing additional bulb in under reamed piles, under specified dia meter (Only
the quantity of extra bulbs are to be paid).etc complete including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of
loading platform by Kentledge method and preparation of pile head or construction of test
cap and dismantling of test cap after test etc. complete as per specification & the
direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried
out by Dynamic method of testing. Note: 2. Testing agency shall submitt the design of 7
1.00 Each
RATE IN WORDS
8
1.00 Each
RATE IN WORDS
9
100.00 ltr
RATE IN WORDS
out by Dynamic method of testing. Note: 2. Testing agency shall submitt the design of
loading platform for the approval of Engineer-in-charge.etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Single pile upto 50 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe capacity)
Single pile above 50 tonne and upto 100 tonne Safe capacity etc complete including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Routine test (Test Load 1.5 times the Safe capacity)
Supplying chemical emulsion in sealed containers including delivery as specified. etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultantChlorpyriphos/ Lindane emulsifiable concentrate of 20%
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 5
10
256.00 Mtr
RATE IN WORDS
11
243.20 sqm
RATE IN WORDS
12Supplying and filling in plinth with Local sand under floors, including watering, ramming,
consolidating and dressing etc complete including supply & transportation of materials
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite
treatment (excluding the cost of chemical emulsion) etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Along the external wall below concrete or masonry apron using chemical emulsion @
2.25 litres per linear metre including drilling and plugging holes etc.:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300
mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2
(1 cement : 2 Coarse sand) to match the existing floor etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
12
134.73 cum
RATE IN WORDS
13
12.872 cum
RATE IN WORDS
14
25.744 cum
RATE IN WORDS
15
41.13 cum
consolidating and dressing etc complete including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations
etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by
ramming and watering, lead up to 50 m and lift upto 1.5 m etc complete including supply
& transportation of materials from the source to the work site, labour, scaffolding, taxes
& royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant.
Carriage by mechanical transport for 5 km lead: etc all complete as per the instruction of
the Bank's Engineer/Architect consultant.
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant.
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 6
RATE IN WORDS
16
11.25 sqm
RATE IN WORDS
17
145.92 sqm
RATE IN WORDS
REINFORCED CEMENT CONCRETE WORK
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand
: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast
40 mm nominal size, well rammed and consolidated and grouted with fine sand, including
finishing the top smooth. etc complete including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant.
Providing and laying in position machine batched and machine mixed design mix M-25
grade cement concrete for reinforced cement concrete work, using cement content as
18
77.23 Cum
RATE IN WORDS
grade cement concrete for reinforced cement concrete work, using cement content as
per approved design mix, including pumping of concrete to site of laying but excluding the
cost of centering, shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,
improve workability without impairing strength and durability as per direction of Engineer-
in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less
cement used as per design mix is payable/recoverable separately).. etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant.
All works for pile cap & plinth beam
Extra for providing richer mixes at all floor levels.
Note:- Excess/less cement over the specified cement content used is
payable/recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC / RMC. (Note:- Cement
content considered in M-30 is @ 340 kg/cum)
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 7
19
RCC in Column 43.71 Cum
RATE IN WORDS
RCC in RoofBeam 59.81 Cum
RATE IN WORDS
RCC in Roof Slab 92.98 Cum
RATE IN WORDS
RCC in Stair Case 10.84 Cum
RATE IN WORDS
RCC Wall 13.15 Cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site
of laying , excluding the cost of centering, shuttering finishing and reinforcement,
including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/
retard setting of concrete, improve workability without impairing strength and durability as
per direction of the Engineer - in - charge. (Note :- Cement content considered in this
item is @ 330 kg/cum. Excess/ less cement used as per design mix is
payable/recoverable separately). etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant.
All works above plinth level upto floor V level
RCC Wall 13.15 Cum
RATE IN WORDS
RCC in Lintel 9.64 Cum
RATE IN WORDS
RCC in Sill 6.03 Cum
RATE IN WORDS
RCC Platform 0.57 Cum
RATE IN WORDS
RCC in Chajja 3.59 Cum
RATE IN WORDS
20
Lower G.F 29338.45 kg
RATE IN WORDS
21
Stilt Floor 10520.62 kg
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level. etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant.
Thermo-Mechanically Treated bars
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level. etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant.
Thermo-Mechanically Treated bars
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 8
RATE IN WORDS
First Floor 13131.28 kg
RATE IN WORDS
Second Floor 11631.45 kg
RATE IN WORDS
Head room & Machine room 3097.94 kg
RATE IN WORDS
FORM WORK
22
379.19 sqm
RATE IN WORDS
131.47 sqm
RATE IN WORDS
Foundations, footings, bases of columns, etc. for mass
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses
etc.
Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering (steel/water proof ply) including strutting, propping etc. and
removal of form for : etc complete including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant.
792.32 sqm
RATE IN WORDS
47.81 sqm
RATE IN WORDS
874.92 Sqm
RATE IN WORDS
50.75 Sqm
RATE IN WORDS
485.70 Sqm
RATE IN WORDS
72.46 sqm
RATE IN WORDS
BRICK WORK
23
Columns, Pillars, Piers, Abutments, Posts and Struts
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
in foundation and plinth in: etc complete including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant.
Cement mortar 1:6 (1 cement : 6 coarse sand)
Stairs, (excluding landings) except spiral-staircases
Suspended floors, roofs, landings, balconies and access platform
Weather shade, Chajjas, corbels etc., including edges
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Small lintels not exceeding 1.5 m clear span, moulding as incornices, window sills, string
courses, bands, copings, bed plates,anchor blocks and the like
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 9
12.52 cum
RATE IN WORDS
24
Silt Floor 22.62 Cum
RATE IN WORDS
First Floor 37.87 Cum
RATE IN WORDS
Second Floor 49.66 Cum
RATE IN WORDS
Head room & Machine room 29.33 Cum
RATE IN WORDS
Silt Floor 1.19 Cum
Brick work with non modular fly ash lime bricks (FALG Bricks) conforming to IS:12894,
class designation 10 average compressive strength in super structure above plinth level
up to floor V level in : etc complete including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant.
Cement mortar 1:6 (1 cement : 6 Coarse sand)
Cement mortar 1:4 (1 cement : 4 coarse sand)
RATE IN WORDS
First Floor 13.57 Cum
RATE IN WORDS
Second Floor 17.26 Cum
RATE IN WORDS
PLASTERING & PAINTING
25
Silt Floor 185.16 sqm
RATE IN WORDS
First Floor 400.79 sqm
RATE IN WORDS
Second Floor 435.72 sqm
RATE IN WORDS
Head room & Machine room 163.85 sqm
RATE IN WORDS
15 mm cement plaster on rough side of single or half brick wall of mix : etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant.
1:6 (1 cement: 6 coarse sand)
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 10
26
Silt Floor 121.06 sqm
RATE IN WORDS
First Floor 362.03 sqm
RATE IN WORDS
Second Floor 417.54 sqm
RATE IN WORDS
Head room & Machine room 159.32 sqm
RATE IN WORDS
27
Silt Floor 226.43 sqm
12 mm cement plaster of mix : etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant.
1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix : etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant.
1:3 (1 cement : 3 fine sand)
Silt Floor 226.43 sqm
RATE IN WORDS
First Floor 245.01 sqm
RATE IN WORDS
Second Floor 240.17 sqm
RATE IN WORDS
Head room & Machine room 53.75 sqm
RATE IN WORDS
28
3010.81 Sqm
RATE IN WORDS
29
3010.81 Sqm
RATE IN WORDS
Neat cement punning. etc complete including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant.
Applying one coat of water thinnable cement primer of approved brand and manufacture
on wall surface etc complete including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Water thinnable cement primer
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 11
30
1825.29 Sqm
RATE IN WORDS
31
1825.29 Sqm
RATE IN WORDS
32
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat
of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the surface
even and smooth complete.etc complete including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Wall painting with acrylic emulsion plastic paint of approved brand and manufacture to
give an even shade : etc complete including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Finishing walls with Weather coat Acrylic Smooth exterior paint of required shade : etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
1185.52 Sqm
RATE IN WORDS
33
Stilt Floor 21.17 Sqm
RATE IN WORDS
First Floor 58.9 Sqm
RATE IN WORDS
Second Floor 60.52 Sqm
RATE IN WORDS
Head room & Machine room 3.24 Sqm
RATE IN WORDS
34
Stilt Floor 21.17 Sqm
RATE IN WORDS
Applying priming coat : etc complete including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on
steel galvanised iron/ steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even
shade : etc complete including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Two or more coats on new work
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 12
First Floor 58.9 Sqm
RATE IN WORDS
Second Floor 60.52 Sqm
RATE IN WORDS
Head room & Machine room 3.24 Sqm
RATE IN WORDS
FLOORING
35
36.57 Sqm
RATE IN WORDS
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more
(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of
approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick
cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white
cement and matching pigments etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in
36
150.93 sqm
RATE IN WORDS
37
25 mm thick74.90 sqm
RATE IN WORDS
38
16.24 Sqm
RATE IN WORDS
skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement
: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing
in white cement mixed with pigment of matching shade etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey
cement slurry mixed with pigment to match the shade of the slab, including rubbing and
polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm
(average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey
cement slurry mixed with pigment to match the shade of the slabs, including rubbing and
polishing etc complete including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 13
39
184.70 Sqm
RATE IN WORDS
40
Providing and laying flamed finish Granite stone flooring in required design and patterns,
in linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar
1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rubbing , curing and
polishing etc. all complete as specified and as directed by the Engineer-in-Charge : etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or
equivalent.
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in
required pattern in linear portion of the building all complete as per architectural drawings,
with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4
(1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm
including pointing with white cement slurry admixed with pigment to match the marble
shade including rubbing, curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge : etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:18 mm thick Italian Marble stone lab,Perlato, Rosso verona, Fire Red or Dark
184.70 Sqm
RATE IN WORDS
41
38.30 sqm
RATE IN WORDS
42
18 mm thick Italian Marble stone lab,Perlato, Rosso verona, Fire Red or Dark
Emperadore etc.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and
similar locations of required size, approved shade, colour and texture laid over 20 mm
thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all levels.etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Area of slab over 0.50 sqm
Providing and fixing machine cut, mirror / eggshell polished , Marble stone work for wall
lining (veneer work) including dado, skirting, risers of steps etc., in required design and
pattern wherever required, stones of different finished surface texture, on 12 mm
(average) thick cement mortar 1:3 (1 cement : 3 oarse sand) laid and jointed with white
cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with
pigment of matching shade, including rubbing, curing, polishing etc. all complete as per
Architectural drawings, and as directed by the Engineer-in-Charge.. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark
Emperadore etc.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 14
38.30 sqm
RATE IN WORDS
43
97.20 metre
RATE IN WORDS
44
4.00 Each
RATE IN WORDS
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including
machine polishing to edge to give high gloss finish etc. complete as per design approved
by Engineer-in-Charge.including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in
kitchen platform, vanity counter and similar location in marble/ Granite/stone work,
including necessary holes for pillar taps etc. including moulding, rubbing and polishing of
cut edges etc complete including supply & transportation of materials from the source
to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as
per the instruction of the Bank's Engineer/Architect consultant:
Mirror polishing on marble work/Granite work/stone work where ever required to give high
45
445.99 sqm
RATE IN WORDS
46
186.66 Sqm
RATE IN WORDS
47 Laqured Glass
7.93 sqm
RATE IN WORDS
WOOD & PVC WORKS
48
Mirror polishing on marble work/Granite work/stone work where ever required to give high
gloss finish etc complete including supply & transportation of materials from the source
to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as
per the instruction of the Bank's Engineer/Architect consultant:
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed
with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing
and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4
coarse sand). etc complete including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Medium shade pigment using 50% white cement 50% Grey cement
Providing wood work in frames of doors, windows, clerestory windows and other frames,
wrought framed and fixed in position with hold fast lugs or with dash fasteners of required
dia & length ( hold fast lugs or dash fastener shall be paid for separately). etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 15
1.37 Cum
RATE IN WORDS
49
62.96 sqm
RATE IN WORDS
50
Rectangular or square0.36 sqm
RATE IN WORDS
Sal wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)
decorative type, core of block board construction with frame of 1st class hard wood and
well matched teak 3 ply veneering with vertical grains or cross bands and face veneers
on both faces of shutters. etc complete including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of
glass excluded) (overall area of door shutter to be measured) : etc complete including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
51
151.50 Rmt
RATE IN WORDS
52
3481.00 Kg
RATE IN WORDS
53
162.00 Each
RATE IN WORDS
Providing and fixing teak wood lipping of size 25x3 mm in pelmet etc complete including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm
diameter bolts, nuts and wooden plugs and embedding in cement concrete block
30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm
nominal size). etc complete including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
square bars etc. including priming coat with approved steel primer etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Fixed to steel windows by welding
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 16
54
5.04 Sqm
RATE IN WORDS
55
125x65x2.12 mm
6.00 Each
RATE IN WORDS
56
Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary
screws etc. complete :including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and
3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete,
including applying a priming coat of approved steel primer. etc complete including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
300x16 mm 4.00 Each
RATE IN WORDS
57
4.59 sqm
RATE IN WORDS
58
3.00 Each
RATE IN WORDS
59
Providing and fixing ball bearing for rolling shutters. etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths,
interlocked together through their entire length and jointed together at the end by end
locks, mounted on specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull operation complete,
including the cost of providing and fixing necessary 27.5 cm long wire springs
manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -
part 1 and M.S. top cover of required thickness for rolling shutters. etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Extra for providing mechanical device chain and crank operation for operating rolling
shutters. etc complete including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Exceeding 10.00 sqm and upto 16.80 sqm in the area
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 17
4.59 sqm
RATE IN WORDS
60
125 mm4.00 Each
RATE IN WORDS
61
38.00 Each
RATE IN WORDS
62
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with
necessary screws etc complete including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with
hooked ends in R.C.C. slabs or beams during laying, including painting the exposed
portion of loop, all as per standard design complete.including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
99.00 Each
RATE IN WORDS
63
250x10 mm33.00 Each
RATE IN WORDS
64
66.00 Each
RATE IN WORDS
65
33.00 Each
RATE IN WORDS
Bank's Engineer/Architect consultant:
125x85x5.5 mm (heavy typ
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws
etc. complete including supply & transportation of materials from the source to the work
site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Providing and fixing bright finished brass handles with screws etc. complete including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Providing and fixing bright finished brass hanging type floor door stopper with necessary
screws, etc. complete. including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 18
66
125x75x4 mm36.00 Each
RATE IN WORDS
67
24.00 Each
RATE IN WORDS
68
Providing and fixing aluminium extruded section body tubular type universal hydraulic
door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight
upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed
adjustment with necessary accessories and screws etc. complete. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
125 mm
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less
than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with
necessary screws etc. complete: :including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less
than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with
necessary screws etc. complete :including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
29.00 Each
RATE IN WORDS
69
34.20 Rmt
RATE IN WORDS
70
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section
90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm
thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester
resin and chopped mat . Door frame laminate shall be 2 mm thick and shall be filled with
suitable wooden block in all the three legs. The frame shall be covered with fiber glass
from all sides. M.S. stay shall be provided at the bottom to steady the frame. etc.
complete. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Providing and fixing to existing door frames.etc. complete. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required
colour and approved brand and manufacture, made with fire - retardant grade
unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails
and styles, with wooden frame and suitable blocks of seasoned wood inside at required
places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels
conforming to IS: 14856, including fixing to frames.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 19
9.45 Sqm
RATE IN WORDS
71
54.68 Sqm
RATE IN WORDS
72
Providing and fixing factory made uPVC window frame made of uPVC extruded sections
having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (±
0.2 mm), corners of the window frame to be Jointed with galvanized brackets and
stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the
frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall
thickness and 3 nos. stainless steel hinges fixed to the frame with Providing and fixing
double glazed hermetically sealed glazing in windows, ventilators and partition etc. with 6
mm thick clear float glass both side, having 12 mm air gap, including providing EPDM
gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary
sealant) etc. complete.including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing factory made uPVC window frame made of uPVC extruded sections
having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (±
0.2 mm), corners of the window frame to be Jointed with galvanized brackets and
stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the
frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall
16.20 Sqm
RATE IN WORDS
73
16.74 Sqm
RATE IN WORDS
ALUMINUM WORK
With float glass panes of 6.0 mm thickness
Providing and fixing factory made uPVC door frame made of uPVC extruded sections
having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (±
0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless
steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames
reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall
thickness and 3 nos. stainless steel hinges fixed to the frame with providing and fixing
single glazing in doors with EPDM rubber / neoprene gasket etc. .including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
With float glass panes of 8 mm thickness
frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall
thickness and 3 nos. stainless steel hinges fixed to the frame with providing and fixing
single glazing in window, ventilator shutters and partitions etc. with EPDM rubber /
neoprene gasket etc. complete .including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 20
74
23.40 Kg
RATE IN WORDS
75
4.68 Sqm
RATE IN WORDS
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions
etc. with EPDM rubber / neoprene gasket etc. complete.including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
With float glass panes of 4.0 mm thickness
Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required
dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and
sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel
screws, (Glazing, paneling and dash fasteners to be paid for separately) : etc.
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
RATE IN WORDS
WATER PROOFING TREATMENT
76
Terrace floor 12.72 cum
RATE IN WORDS
77
Terrace floor 254.32 Sqm
RATE IN WORDS
Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) etc. complete.including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and laying in situ five course water proofing treatment with APP (Atactic
Polypropylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40Kg per sqm, 2nd & 4th courses of bonding material @ 1.20
kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702,
3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00
Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron
HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is
protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall be
finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement
: 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over
a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat ( item of
laying brick tiles shall be paid for separately).etc. complete.including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 21
78
254.32 Sqm
RATE IN WORDS
79
Terrace floor 254.32 Sqm
RATE IN WORDS
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester
of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the
membrane by Butane Torch as per manufactures recommendation etc.
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI
(solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the
ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement &
marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts
complete, including providing skirting upto 150 mm height along the parapet walls in the
same manner.etc. complete.including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free
80
Terrace floor 254.32 Sqm
RATE IN WORDS
STRUCTURAL GLAZING
81
465.71 Kg
RATE IN WORDS
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free
Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of
foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per
litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40
mm thick cement screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm
nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with
24 G wire netting and sealing the joints with polymerized mastic, etc. complete.including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Providing and supplying aluminium extruded tubular and other aluminium sections as per
the architectural drawings and approved shop drawings , the aluminium quality as per
grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80
microns conforming to AAMA 2604 of required colour and shade as approved by the
Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws
etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account).etc. complete.including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 22
82
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of
sizes, shapes and profiles, as required as per the site conditions, to seal the gap between
Structural analysis & design and preparation of shop drawings for the specified design
loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times
design wind pressure without any failure), including functional design of the aluminum
sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and
splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and
weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave
cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection
against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5
brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional
movement for achieving perfect verticality and fixing structural glazing system rigidly to
the RCC/ masonry/structural steel framework of building structure using stainless steel
anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and
washers etc. of stainless steel grade 316, of the required capacity and in required
numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather
silicone sealant compatible with the structural silicone sealant of required bite size in a
clean and controlled factory / work shop environment , including double sided spacer
tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as
per the approved sealant design, within and all around the perimeter for holding glass.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid)
unitized system of structural glazing (with open joints) for linear as well as curvilinear
portions of the building for all heights and all levels, including:
sizes, shapes and profiles, as required as per the site conditions, to seal the gap between
the building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to
make it watertight, by incorporating principles of pressure equalization, providing suitable
gutter profiles at bottom (if required), making necessary holes of required sizes and of
required numbers etc. complete. This item includes cost of all inputs of designing, labour
for fabricating and installation of aluminium grid, installation of glazed units, T&P,
scaffolding and other incidental charges including wastages etc., enabling temporary
structures and services, cranes or cradles etc. as described above and as specified. The
item includes the cost of getting all the structural and functional design including shop
drawings checked by a structural designer,dully approved by Engineer-in-charge. The
item also includes the cost of all mock ups at site, cost of all samples of the individual
components for testing in an approved laboratory, field tests on the assembled working
structural glazing as specified, cleaning and protection till the handing over of the building
for occupation. In the end, the Contractor shall provide a water tight structural glazing
having all the performance characteristics etc. all complete as required, as per the
Architectural drawings, as per item description, as specified, as per the approved shop
drawings and as directed by the Engineerin- Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded
aluminium section capping for fixing in the grooves of the curtain glazing and vermin
proof stainless steel wire mesh shall be paid for separately under relevant items under
this subhead. However, for the purpose of payment, only the actual area of structural
glazing (including width of grooves ) on the external face shall be measured in sqm. up to
two decimal places.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 23
84.68 Sqm
RATE IN WORDS
Note:-2. The following performance test are to be conducted on structural glazing system
if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated
by NABL(National Accreditation Board for Testing and Calibration Laboratories),
Department of Science & Technologies, India. Cost of testing ispayable separately. The
NIT approving authority will decide the necessity of testing on the basis of cost of the
work, cost of the test and importance of the work. Performance Testing of Structural
glazing system Tests to be conducted in the NBL Certified laboratories
1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to
+300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing
method for a range up to 2000 ml.”
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method
for a range upto 2000 ml”
4. Structural Performance Deflection and deformation by static air pressure test (1.5
times desing wind pressure without any failure) as per ASTME-330-10 testing method for
a range upto 50 mm”
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for
Qualitative test” Tests to be conducted on site
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto
2000ml”
83
84.68 Sqm
RATE IN WORDS
84Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium
Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of
the building , for all heights and all levels etc. including:
Structural analysis & design and preparation of shop drawings for pressure equalisation
or rain screen principle as required, proper drainage of water to make it watertight
including checking of all the structural and functional design.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat
strengthened monolithic float glass of approved colour and shade with reflective soft
coating on surface # 2 of approved colour and shade so as to match the colour and
shade of the IGUs in the vision panels etc. ,all complete for the required performances as
specified, as per the Architectural drawings, as per the approved shop drawings, as
specified, and as directed by the Engineer- in- Charge. For payment, only the actual area
of glass on face # 1 of the glass panels (but excluding the area of grooves and weather
silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for
fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent
Item*).
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2,
having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection
internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28)
and U value of 3.0 to 3.3 W/m2 degree K etc. . The properties of performance glass shall
be decided by technical sanctioning authority as per the site requirement. etc.
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 24
30.19 Sqm
Providing, fabricating and supplying and fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of approved shades made out of 4mm thick
aluminium composite panel material consisting of 3mm thick FR grade mineral core
sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium
composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1
and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts,
bolts, washers, cleats, weather silicone sealant, backer rods etc.
The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the wind load movement, fasteners, SS 316
Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-
metallic contacts all complete required to perform as per specification and drawing
The item includes cost of all material & labour component, the cost of all mock ups at
site, cost of all samples of the individual components for testing in an approved
laboratory, field tests on the assembled working curtain wall with aluminium composite
panel cladding, cleaning and protection of the curtain wall with aluminium composite
panel cladding till the handing over of the building for occupation. Base frame work for
ACP cladding is payable under the relevant aluminium item.s The Contractor shall
provide curtain wall with aluminium composite panel cladding, having all the performance
characteristics all complete , as per the Architectural drawings, as per item description,
as specified, as per the approved shop drawings and as directed by the Engineer-in-
Charge. However, for the purpose of payment, only the actual area on the external face
of the curtain wall with Aluminum Composite Panel Cladding (including width of groove)
shall be measured in sqm. up to two decimal places.(Make-TIMEX or EQUIVALENT)
30.19 Sqm
RATE IN WORDS
85
90.00 Rft
RATE IN WORDS
TOTAL
Providing stainless steel hand rail for staircase with approve design made out of 18
gauge pipe of approved make as directed by Engineer in charge.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 25
INTERNAL & EXTERNAL SANITARY WORKS
Sl
noBOQ DESCRIPTION QTY UNIT RATE IN FIGURES AMOUNT
( A)SANITARY INSTALLATIONS
1
9.00 each
RATE IN WORDS
2
DETAIL TENDER BOQ OF PROPOSED ODISHA STATE CO-OPERATIVE BANK, LINK ROAD BRANCH OVER
PLOT NO-1027, MOUZA CUTTACK TOWN, UNIT NO-33,
AT- CUTTACK
SECTION-2
Providing and fixing white vitreous china pedestal type water closet (European type W.C.
pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe,
with manually controlled device (handle lever), conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and making good the walls and floors wherever
required :etc. complete.including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350
mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush
pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :
2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of
fittings and cutting and making good the walls and floors wherever required :etc.
2.00 each
RATE IN WORDS
3
9.00 each
RATE IN WORDS
4
White 9.00 each
RATE IN WORDS
Providing and fixing white vitreous china pedestal for wash basin completely recessed at
the back for the reception of pipes and fittings.etc. complete.including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
fittings and cutting and making good the walls and floors wherever required :etc.
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Single half stall urinal with 5 litre P.V.C. automatic flushing
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm
C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting
and making good the walls wherever require:complete.including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
White Vitreous China Flat back wash basin size 550x 400 mm
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 26
5
2.00 each
RATE IN WORDS
6
9.00 each
RATE IN WORDS
7
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with
C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets,
cutting and making good the walls wherever required :etc. complete.including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Kitchen sink with drain board
510x1040 mm bowl depth 250 mm
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved
quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
brass screws and washers complete.including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on
anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed
with 40 mm long screws, rawl plugs etc., complete.including supply & transportation of
9.00 each
RATE IN WORDS
8
C.P. brass 9.00 each
RATE IN WORDS
9
36.00 each
RATE IN WORDS
10
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and
repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing
complete so as to make it leak proof etc., complete.including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
with 40 mm long screws, rawl plugs etc., complete.including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing toilet paper holder :etc., complete.including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Cutting holes up to 30x30 cm in walls including making good the same:etc.,
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
With common burnt clay F.P.S. (non modular) bricks
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 27
10.00 each
RATE IN WORDS
11
110 mm diameter 90.00 metre
RATE IN WORDS
12
Bend 87.5°
110 mm bend 16.00 each
RATE IN WORDS
Shoe (Plain)
110 mm Shoe 8.00 each
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to
IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10
mm gap for thermal expansion, (i) Single socketed pipes. etc., complete.including supply
& transportation of materials from the source to the work site, labour, scaffolding, taxes
& royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal
expansion.etc., complete.including supply & transportation of materials from the source
to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as
per the instruction of the Bank's Engineer/Architect consultant:
110 mm Shoe 8.00 each
RATE IN WORDS
13
8.00 each
RATE IN WORDS
14
2.40 cum
RATE IN WORDS
15
110mm dia pipe 165.00 metre
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter
and weighing not less than 440 grams.etc., complete.including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :etc., complete.including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Providing and fixing on wall UV stablized Unplasticised Rigid PVC pipes (single socketed)
having 3.2mm wall thickness conforming to IS:13592 (4kg/sqcm) including jointing with
seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.etc.,
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 28
RATE IN WORDS
50mm dia pipe18.00 metre
RATE IN WORDS
16
Vent cowl - 110 mm 9 each
RATE IN WORDS
Access door cap - 110 mm 18 each
RATE IN WORDS
"P" trap 110mmx110mm long 12 each
RATE IN WORDS
Multi floor trap 110 12 each
RATE IN WORDS
Coupler - 110 mm 25 each
RATE IN WORDS
Single tee with door -
110x110x110 mm18 each
Providing and fixing on wall UV stablized Unplasticised Rigid PVC moulded
fittings/accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to
IS:13592 (heavy) jointing with seal ring conforming to IS:5382 leaving 10mm gap for
thermal expansion.etc., complete.including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
110x110x110 mmRATE IN WORDS
110 mm bend Door 9 each
RATE IN WORDS
110 mm plain bend 12 each
RATE IN WORDS
17
62.00 sqm
RATE IN WORDS
18
1st F.F 8.00 cum
RATE IN WORDS
2nd F.F 8.00 cum
RATE IN WORDS
( B) WATER SUPPLY
Supply all materials, labour T & P & filling sunken floor of toilet blocks with approved
quality clynder under size 40mm to 50mm added with cement slurry supply. etc.,
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Supplying all materials, labors, taxes, T&P treatment, the sunken with NANO Technology
water proofing compound Zycosile, Zycoprime, Elostoban mixture etc, including cement
plaster(1:4) with punning as per the direction of E.I.C.As per guideline of company etc.,
complete.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 29
1
15 mm nominal outer dia .Pipes.10.00 metre
RATE IN WORDS
20 mm nominal outer dia .Pipes.30.00 metre
RATE IN WORDS
25 mm nominal outer dia .Pipes.20.00 metre
RATE IN WORDS
32mm nominal outer dia. Pipes25.00 metre
RATE IN WORDS
2
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing
the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one
step CPVC solvent cement and the cost of cutting chases and making good the same
including testing of joints Concealed work, including cutting chases and making good the
walls .etc., complete.including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply, including all CPVC plain & brass threaded fittings, including
fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with
one step CPVC solvent cement and testing of joints etc., complete.including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
25 mm nominal outer dia .Pipes.25.00 metre
RATE IN WORDS
32 mm nominal outer dia .Pipes.30.00 metre
RATE IN WORDS
50 mm nominal outer dia .Pipes.45.00 metre
RATE IN WORDS
3
45.00 metre
RATE IN WORDS
4
80 mm dia nominal bore 30.00 metre
RATE IN WORDS
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Internal work - Exposed on wall
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply including all CPVC plain & brass threaded fittings This
includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling
& testing of joints complete including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
75 mm nominal inner dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling
etc including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 30
5
120.00 metre
RATE IN WORDS
6
15 mm nominal bore 2.00 each
RATE IN WORDS
7
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved
quality conforming to IS:8931 a) 15 mm nominal bore etc complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
out the excavated soil, and then returning the soil as required, in layers not exceeding 20
cm in depth, including consolidating each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead of 50 m :complete including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
7
15mm nominal bore 22.00 each
RATE IN WORDS
8
25 mm nominal bore 1.00 Each
RATE IN WORDS
32 mm nominal bore. 5.00 Each
RATE IN WORDS
50mm dia nominal bore 3.00 Each
RATE IN WORDS
80 mm dia nominal bore 5.00 Each
RATE IN WORDS
9
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed
end) : etc complete including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with
Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball .etc complete including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
50 mm nominal bore, 242mm long, weighing not less than 1240 gms
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 31
2.00 Each
RATE IN WORDS
10
25.00 Each
RATE IN WORDS
11
10.00 Each
RATE IN WORDS
Cutting holes up to 30x30 cm in walls including making good the same: etc complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
With common burnt clay F.P.S. (non modular) bricks
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and
repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing
complete so as to make it leak proof.etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4
(1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter,
12
4.00 Each
RATE IN WORDS
13
7000.00 litre
RATE IN WORDS
14
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI :
12701 marked, with cover and suitable locking arrangement and making necessary holes
for inlet, outlet and overflow pipes but without fittings and the base support for tank. etc
complete including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and
conforming to IS:8931 including C.P. brass extension if required:
(JAQUAR/MARK/EQUIVALENT) etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
(1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter,
160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab
1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c
necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded
stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design :etc complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 32
15mm dia C.P.Pillor cock 9.00 Each
RATE IN WORDS
15mmm C.P.Urinal flush cock2.00 Each
RATE IN WORDS
15mm dia C.P. flange 35.00 Each
RATE IN WORDS
15mm dia C.P. extension piece35.00 Each
RATE IN WORDS
C.P. towel ring 9.00 Each
RATE IN WORDS
Two way bib cock (800gms)
with health facet9.00 Each
RATE IN WORDS
Bottle trap set with extension
pipes11.00 Each
RATE IN WORDS
Soap dish plate18.00 Each
RATE IN WORDS
Providing and fixing stainless steel drain jali of approved make/quality. etc complete
including supply & transportation of materials from the source to the work site, labour, 15
24.00 Each
RATE IN WORDS
16
LS
RATE IN WORDS
17
25000.00 Ltr.
RATE IN WORDS
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Providing & construction of RCC base slab of following size with necessary brick work in
CM(1:6), beam & slab of RCC (1:11/2:3) etc complete including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Base slab=(1.5x5.0)mtr with stegging 600mm over terrace level
Design, Construction, Testing & Commissioning of following capacity R.C.C under ground
clean water reservoir including provision of G.I ladder, C.I manhole (with locking
arrangement) ventilator, loading, overflow, washout chamber, section and delivery piping
& valve arrangement etc. complete including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
25000 lit. Fire Fighting sump with overhead pump house .
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 33
18
1.00 set
RATE IN WORDS
19
Fire Fighting (4mt x 3mt) 12.00 sqm
RATE IN WORDS
( C) SEWERAGE
Supplying all materials, labor, T&P and cost of pump house of following size as per the
provided drawing & specifications. Earthwork in hard soil, PCC(1:3:6), brickwork(1:6) in
foundation, plinth & supedr structure, 12mm C.P (1:6) inside & 16mm (1:6) outside
R.C.C. roof slab in M-20. MS door & window internal electrification, sintex overhead tank,
inside & outside Cement painting etc. complete including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
out the excavated soil, and then returning the soil as required, in layers not exceeding 20
Supply, installation, testing & commissioning of centrifugal pump sets would provide head
& discharge of 45 mt & 5 LPS respectively including control panel, section and delivery
piping & valve arrangement etc. all complete as the direction of E.I.C ( @ 5 H.P per set)
with 100% Stand by for drinking water purpose.etc. complete including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
1
87.00 metre
RATE IN WORDS
2
100 mm diameter S.W. pipe 15.00 metre
RATE IN WORDS
150 mm diameter S.W. pipe 72.00 metre
RATE IN WORDS
3
100 mm dia. R.C.C. pipe 15.00 metre
RATE IN WORDS
out the excavated soil, and then returning the soil as required, in layers not exceeding 20
cm in depth, including consolidating each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead of 50 m :etc. complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per
standard design :etc. complete including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed
with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete :including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 34
150 mm dia. R.C.C. pipe 72.00 metre
RATE IN WORDS
4
13.00 each
RATE IN WORDS
5Extra for depth for manholes : etc. complete :including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Size 90x80 cm
With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand )
with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded
stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar
1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making
channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate
20 mm nominal size) finished with a floating coat of neat cement complete as per
standard design : etc. complete :including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610
mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight
of cover 23 kg and weight of frame 15 kg) :
With Sewer bricks conforming to IS : 4885
1.00 metre
RATE IN WORDS
6
7.00 each
RATE IN WORDS
7
6.00 each
RATE IN WORDS
8
1.00 each
With Sewer bricks conforming to IS : 4885
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as
per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross
section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm
with minimum 112 mm space between protruded legs having 2 mm tread on top surface
by ribbing or chequering besides necessary and adequate anchoring projections on tail
length on 138 mm as per standard drawing and suitable to with stand the bend test and
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size
(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70
kg as per standard design:etc. complete :including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
150 x 100 mm size P type
With sewer bricks conforming to IS : 4885
Supplying all material & labour T&P construction of 50 user septic tank with 1 year
clearing interval of inner size 5.00mtX1.6X1.3mt liquid depth as per drawing etc.
complete :including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 35
RATE IN WORDS
9
1.00 each
RATE IN WORDS
( D) TUBE WELL & RAIN WATER HARVESTING
1
200 mm dia
70.00 metre
RATE IN WORDS
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting samples from different strata,
preparing and submitting strata chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for the job,
upto 90 metre depth below ground level.etc. complete :including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
All types of soil
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting samples from different strata,
preparing and submitting strata chart/ bore log, including hire & running charges of all
Supplying all material & labour T&P construction of Soak Way Pit of the following size
with dry brick work etc. complete :including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
2
30.00 metre
RATE IN WORDS
3
150 mm nominal size dia 70.00 metre
RATE IN WORDS
4
150 mm nominal size dia 30.00 metre
RATE IN WORDS
preparing and submitting strata chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for the job, beyond 90 metre & upto 150
metre depth below ground level .etc. complete :including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Rocky strata including Boulders
200 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized
PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including
required hire and labour charges, fittings & accessories etc. all complete, for all
depths,.including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized
PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire &
labour charges, fittings & accessories etc. all complete, for all depths, including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 36
5
8.00 hour
RATE IN WORDS
6
200 mm dia 2.00 each
RATE IN WORDS
7
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of
tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size
complete. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish
maximum rate of usable water yield without sand content (beyond permissible limit), with
required capacity air compressor, running the compressor for required time till well is fully
developed, measuring yield of well by “V” notch method or any other approved method,
measuring static level & draw down etc. by step draw down method, collecting water
samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,
including hire & labour charges of air compressor, tools & accessories etc., including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top
of bore well housing/ casing pipe, removable as per requirement, all complete for
borewell of: etc., including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:.
200 mm clamp 4.00 each
RATE IN WORDS
8
10.00 cum
RATE IN WORDS
9
10.00 cum
RATE IN WORDS
10
15.00 cum
RATE IN WORDS
of the Bank's Engineer/Architect consultant:.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in
recharge pit, in the required thickness, for all leads & lifts, all complete . including supply
& transportation of materials from the source to the work site, labour, scaffolding, taxes
& royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the
recharge pit, over the existing layer of boulders, in required thickness, for all leads &
lifts,all complete . including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in
recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 37
11
60.00 metre
RATE IN WORDS
12
150 mm dia. R.C.C. pipe 60.00 metre
RATE IN WORDS
13
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting
out the excavated soil, and then returning the soil as required, in layers not exceeding 20
cm in depth, including consolidating each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead of 50 m :all complete
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:.
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed
with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete :including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone
aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as
per standard design :including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:.
150 mm diameter S.W. pipe 60.00 metre
RATE IN WORDS
14
10.00 each
RATE IN WORDS
15
1.00 set
RATE IN WORDS
TOTAL
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement
mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as
per standard design :including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying all materials, labors, T&P & installation testing commisionning with all
accessories like Riser Pipe, Control panel, 3 core flat copper cable, SS nipples & GI
fitting etc of 3phase 560 cycles vertical submerrsibble pump set switable for 200mm dia
production well with a head of 45.0 mt & discharge 3lps to 5lps including 100% stand by
(approx 2 HP) 1 set make KSB/ Texmo/Tora /equivalent including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:.
instruction of the Bank's Engineer/Architect consultant:.
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 38
SITE DEVELOPMENT
(A) C.C ROAD
Sl
noBOQ DESCRIPTION QTY UNIT RATE IN FIGURES AMOUNT
1
In all types of soil 120.45 cum
RATE IN WORDS
2
DETAIL TENDER BOQ OF PROPOSED ODISHA STATE CO-OPERATIVE BANK, LINK ROAD BRANCH OVER
PLOT NO-1027, MOUZA CUTTACK TOWN, UNIT NO-33,
AT- CUTTACK
SECTION-3
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
etc. complete :including supply & transportation of materials from the source to the work
site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne
capacity after excavating earth to an average of 22.5cm depth, dressing to camber and
consolidating with road roller including making good the undulations etc. and re-rolling the
sub grade and disposal of surplus earth with lead upto 50 metres. etc. complete
:including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
192.72 Sqm
RATE IN WORDS
3
48.18 cum
RATE IN WORDS
4
9.636 cum
RATE IN WORDS
5
Construction of granular sub-base by providing close graded Material conforming to
specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by
tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness
with motor grader on prepared surface and compacting with vibratory power roller to
achieve the desired density etc. complete :including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR
Value-25
Supplying and filling in plinth with Local sand under floors, including watering, ramming,
consolidating and dressing complete. :including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level : complete. :including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 39
24.1 cum
RATE IN WORDS
6
38.544 cum
RATE IN WORDS
(B) SURFACE DRAIN
1
In all types of soil 162.89 cum
RATE IN WORDS
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size)
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm
nominal size) in pavements, laid to required slope and camber in panels as required
including consolidation finishing and tamping complete. :including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in
foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including
dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the
excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m.
ETC including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
RATE IN WORDS
2
18.10 cum
RATE IN WORDS
3
18.10 cum
RATE IN WORDS
4
141.00 each
RATE IN WORDS
Providing and fixing factory made precast RCC perforated drain covers, having concrete
of strength not less than M-25, of size 1000 x 450x100 mm, reinforced with 8 mm dia four
nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia
perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size
50 mm x 1.6 mm complete, including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
reinforcement - All work up to plinth level :
Supplying and filling in plinth with Local sand under floors, including watering, ramming,
consolidating and dressingeyc including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 40
5
41.77 cum
RATE IN WORDS
6
250.60 sqm
RATE IN WORDS
7
19.49 cum
RATE IN WORDS
Brick work with modular extruded brunt fly ash clay sewer bricks (Conforming to IS: 4885
) in foundation and plinth including supply & transportation of materials from the source
to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as
per the instruction of the Bank's Engineer/Architect consultant:
Cement Mortar 1:4 ( 1 cement : 4 coarse sand)
12 mm cement plaster : including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
1:4 (1 cement : 4 coarse sand)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations
etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by
ramming and watering, lead up to 50 m and lift upto 1.5 m. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
RATE IN WORDS
8
12 mm cement plaster : 250.60 sqm
RATE IN WORDS
9
143.40 cum
RATE IN WORDS
(C) BOUNDRY WALL
1
0.18 Cum
RATE IN WORDS
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Neat cement punning. including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Carriage by mechanical transport for 5 km lead:
Providing and laying cement concrete in retaining walls, return walls, walls(any thickness)
including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,
string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills,
fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering
and finishing: including supply & transportation of materials from the source to the work
site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 41
2
RCC in Column 0.90 Cum
RATE IN WORDS
3
Thermo-Mechanically Treated bars
148.50 Kg
RATE IN WORDS
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix, manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads,
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site
of laying , excluding the cost of centering, shuttering finishing and reinforcement,
including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/
retard setting of concrete, improve workability without impairing strength and durability as
per direction of the Engineer - in - charge. (Note :- Cement content considered in this
item is @ 330 kg/cum. Excess / less cement used as per design mix is
payable/recoverable separately). including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level. including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
RATE IN WORDS
4
14.82 Sqm
RATE IN WORDS
5
9.55 Cum
RATE IN WORDS
6
1:6 (1 cement: 6 coarse sand) 161.30 Sqm
RATE IN WORDS
712 mm cement plaster of mix :including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Centering and shuttering including strutting, propping etc. and removal of form for
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Columns, Pillars, Piers, Abutments, Posts and Struts
Brick work with non modular fly ash lime bricks (FALG Bricks) conforming to IS:12894,
class designation 10 average compressive strength in super structure above plinth level
up to floor V level in : including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Cement mortar 1:6 (1 cement : 6 Coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix : including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 42
1:6 (1 cement: 6 coarse sand) 183.70 Sqm
RATE IN WORDS
8
1:3 (1 cement : 3 fine sand) 12.42 Sqm
RATE IN WORDS
9
357.42 Sqm
RATE IN WORDS
10
6 mm cement plaster of mix :including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Cement washing 1 coat with grey cement etc complete. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
New work (three or more coats)
Finishing walls with Acrylic Smooth exterior Weather coat paint of required shade :
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat
of exterior primer applied @ 2.20 kg/ 10 sqm)
357.42 Sqm
RATE IN WORDS
11
3449.32 Kg
RATE IN WORDS
12
118.26 Sqm
RATE IN WORDS
(D) CROSS DRAINAGE WORK WITH COW CATCHER
2.00 Nos.
RATE IN WORDS
TOTAL
2.5mX4m as per drawing and specification.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat with approved steel primer all
complete. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Fixed to steel windows by welding
Painting with synthetic enamel paint of approved brand and manufacture to give an even
shade :including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 43
FIRE FIGHTING
( A)Down Commer System
Sl
noBOQ DESCRIPTION QTY UNIT RATE IN FIGURES AMOUNT
1
1.00 Nos
RATE IN WORDS
2
1.00 Set
RATE IN WORDS
DETAIL TENDER BOQ OF PROPOSED ODISHA STATE CO-OPERATIVE BANK, LINK ROAD BRANCH OVER
PLOT NO-1027, MOUZA CUTTACK TOWN, UNIT NO-33,
AT- CUTTACK
SECTION-4
Centrifugal type Boosting Fire pump of capacity 900 LPM @ 30 M. head with Class-A
Insulation, 50 Hz.,415 V Three Phase Induction Motor (7.5 HP), 2880 RPM, complete
with all associated accessories.Make-Lubi/Cromton Greaves/Kirloskar :including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Pump starter panel to start/stop of booster pump complete in all respect. :including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
3
1.00 No.
RATE IN WORDS
4
100 mm NB 2.00 No.
RATE IN WORDS
5
100 mm NB 1.00 No.
RATE IN WORDS
Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves below of suitable
size with all accessories .ake-H.Guru,:including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
ISI Mark CI butterfly valves( PN 16) slim seal standared lever operated type with required
flanges, nuts, bolts etc. complete.Make-Kartar/Intervalve/Veeson :including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
ISI Mark Dual Plate Wafer Type Non-return valves ( PN 16) with required flanges, nuts,
bolts and gaskets etc. complete.Make-Kartar/Intervalve/Veeson :including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 44
6
25 mm NB 3.00 No.
RATE IN WORDS
7
100 mm NB 1.00 No.
RATE IN WORDS
8
3.00 No.
RATE IN WORDS
Standard make Y Strainer with required flanges, nuts, bolts and gaskets etc. complete.
:including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
GM Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique
tyep, as per IS :5290/93.Make-Omex/Eversafe/Gtech :including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
GM short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per
IS:903..Make-Omex/Eversafe/Gtech :including supply & transportation of materials from
Bronze Ball Valve (Threaded).Make-Leader/Zoloto :including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
9
3.00 No.
RATE IN WORDS
10
6.00 No.
RATE IN WORDS
11
3.00 No.
RATE IN WORDS
12
3.00 No.
IS:903..Make-Omex/Eversafe/Gtech :including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
ISI marked Fire Hose fitted with copper alloy male & female coupling complete by GI
wire binding, size: 63 mm NB and 15 meter long each. .Make-Omex/Eversafe/Gtech
:including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
MS Hose Box to accommodate 2 nos. of 15 mtr long fire hose and a branch pipe, wall
mounted type. :including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and
moving parts with rubber hose of 19 mm dia. and 30 mtrs. long with self closing shut-off
nozzle as per IS: 444., complete with all accessories..Make-Omex/Eversafe/Gtech
:including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 45
RATE IN WORDS
13
1.00 No.
RATE IN WORDS
14
1 Lot
RATE IN WORDS
15
100mm NB 36.00 Mtr.
RATE IN WORDS
2- way fire brigade connection..Make-Omex/Eversafe/Gtech :including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Control & power cabling as required for establishing of the pumping system Make-
Polycab/R.R Kable/Finolex :including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Medium grade MS pipe as per IS: 1239 with all fittings and accessories complete with
anti corrosive painting of p.o.red etc. as may be applicable, to complete in all
respect.Make-Tata/Jindal :including supply & transportation of materials from the source
to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as
per the instruction of the Bank's Engineer/Architect consultant:
80 mm NB 6.00 Mtr.
RATE IN WORDS
25 mm NB 6.00 Mtr.
RATE IN WORDS
16
200 Kg.
RATE IN WORDS
( B)Fire Alarm System
1
1.00 No
RATE IN WORDS
Structural Steels as required for making of supports etc. to make the system complete
:including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Analog Addressable Fire Alarm Control panel with battery back up for 8 hours normal
operation and 15 minutes alarm operation. The control panel, battery charger etc, shall
be UL / EN listed.The panel shall be 4 loops capacity and expandable to 6 loops. The
panel shall consisting with 80 character LCD display and RS 485 for networking. Make-
GST/EST/Morley IAS :including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 46
2
44.00 No
RATE IN WORDS
3
4.00 No
RATE IN WORDS
4
4.00 No
RATE IN WORDS
Analogue Addressable Multi Sensor Smoke detector with programmable for timed
automatic sensitivity selection with base, Junction box and other accessories as required
and Cetectors shall be UL listed,Make-GST/EST/Morley IAS :including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Addressable Single action Manual pull station having an integrally mounted addressabla
module that monitors and reports contact status.Make-GST/EST/Morley IAS :including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Addressable Horn / Strobe wall mounted type rated at 82 dBA @ 3m for Audible
annunciation and 75cd flashintg at 1 Hz for visual indication.Make-GST/EST/Morley IAS
:including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
RATE IN WORDS
5
2.00 No
RATE IN WORDS
6
14.00 No
RATE IN WORDS
7
180.00 Mtr
RATE IN WORDS
Analogue Addressable Fault isolator module capable of monitoring shorted loop circuit
and automatically restore communications when shorted conditions are corrected
:including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Supplying, laying, testing and commissioning of Response Indicator for Above Ceiling
Detector-Make-GST/EST/Morley IAS :including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Supplying, installing, testing and commissioning of 2 runs of 1.5 sq. mm, PVC insulated
copper wires confirming to IS standards Make-Finolex,Polycab,R.R Kable :including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 47
8
20 mm dia.180.00 Mtr
RATE IN WORDS
(C)FIRE EXTINGUISHERS
1
6.00 Nos.
RATE IN WORDS
Supplying, installing and commissioning Portable Fire extinguishers of following type &
capacity.Make-Safex,Omex,Kanex :including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Providing and fixing Co2 type fire extinguisher as per IS 2878 with discharge time of 10
sec to 18 sec and gas storage pressure of 85 kgf/sq cm with internal charge.
i)Capacity 4.5 kg.(Wall Mounted)
ABC chemical powder type fire extinguisher of 6 Kgs. Capacity, with initial filling in brand
new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2
gas cartridge, discharge hose, wall mounting bracket etc. complete, confirming to
IS:15683 :including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Supply, installation of PVC conduits having 1.5mm wall Thickness with necessory fittings
like Junction boxes, collars, saddles screws on walls / ceiling / embeded in the walls
etc.complete.Make-AKG/Any ISI Mark :including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
6.00 Nos.
RATE IN WORDS
6.00 Nos.
RATE IN WORDS
TOTAL
of the Bank's Engineer/Architect consultant:
Providing and fixing 9 Litres capacity fire extinguisher water type Gas Pressure
conforming to IS: 940 marking, fixed to wall. :including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 48
(ELECTRICAL)
INTERNAL ELECTRICAL
Sl
noBOQ DESCRIPTION QTY UNIT RATE IN FIGURES AMOUNT
A(modular Wiring Items)
1
248.00 Nos
RATE IN WORDS
2
DETAIL TENDER BOQ OF PROPOSED ODISHA STATE CO-OPERATIVE BANK, LINK ROAD BRANCH OVER
PLOT NO-1027, MOUZA CUTTACK TOWN, UNIT NO-33,
AT- CUTTACK
SECTION-5
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit, with modular switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as
required.GROUP-C including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper
conductor, single core cable (Finolex/Polycab/L&T) or any other equivallent reputed make
ISI marked as approved, in surface/recessed PVC conduit medium (AKG or any other
equivallent reputed make ISI marked as approved) as required. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
2 x 2.5 + 1 x 2.5 sq mm.(LDB to
LSB)311.00 Mtr
RATE IN WORDS
4 x 2.5 + 2 x 2.5 sq mm.(LDB to
LSB)288.00 Mtr
RATE IN WORDS
6 x 2.5 .(LDB to LSB)(IN
EXISTING CONDUIT)120.00 Mtr
RATE IN WORDS
2 x 4 + 1 x 4 sq mm.(CDB to
Power.comp. board)256.00 Mtr
RATE IN WORDS
4 x 4 + 2 x 4 sq mm.(CDB to
Power.comp. board)211.00 Mtr
RATE IN WORDS
6 x 4 .(CDB to CB)(IN
EXISTING CONDUIT)116.00 Mtr
RATE IN WORDS
2 x 6 + 1 x 6 sq mm.( L.Panel to
LDB/UDB TO UBDB)88.00 Mtr
RATE IN WORDS
4 x 6 + 2 x 6 sq mm.( L.Panel to
LDB)( L.Panel to LDB/UDB TO
UBDB)
121.00 Mtr
RATE IN WORDS
4 x 10 + 2 x 10 sq mm.( P.Panel
to PDB)138.00 Mtr
RATE IN WORDS
4 x 16 + 2 x 16 sq mm.( P.Panel
toPDB)145.00 Mtr
RATE IN WORDS
Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 49
3
151.00 Nos
RATE IN WORDS
4
151.00 Nos
RATE IN WORDS
5
Supplying and fixing 5/6A modular switch on the existing modular plate & switch box
including connections but excluding modular plate etc. as required. of Anchor/wipro
make.(for computer point 2x5/6A Switch+2x5/6A Socket & other light load 1x5/6A
Switch+1x5/6A Socket with separate modular board of suitable size) including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Supplying and fixing 3 pin 5/6A modular socket on the existing modular plate & switch
box including connections but excluding modular plate etc. as required. of Anchor/wipro
make.(for computer point 2x5/6A Switch+2x5/6A Socket & other light load 1x5/6A
Switch+1x5/6A Socket with separate modular board of suitable size) including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Supplying and fixing 15/16A modular switch on the existing modular plate & switch box
including connections but excluding modular plate etc. as required. of Anchor/wipro
make.(for power point 1x15/16A Switch+1x15/16A Socket with separate modular board 5
33.00 Nos
RATE IN WORDS
6
33.00 Nos
RATE IN WORDS
7
4 (4+12)way, Double Door TPN
DB(comp.,light,power,UPS)
make.(for power point 1x15/16A Switch+1x15/16A Socket with separate modular board
of suitable size) including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Supplying and fixing 15/16A modular socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required. of Anchor/wipro
make.(for power point 1x15/16A Switch+1x15/16A Socket with separate modular board
of suitable size) including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant:
Supplying and fixing of following mentioned way, three pole/single pole and neutral,
sheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess,
complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper
conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar.
Legrand/Hager/Siemens make, or any other equivallent A catagories reputed make ISI
marked as approved including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 50
6.00 Nos
RATE IN WORDS
2+12 way SPN DB (Double door)(comp.,light,power,UPS)
6.00 Nos
RATE IN WORDS
8
144.00 Nos
RATE IN WORDS
9
6.00 Nos
RATE IN WORDS
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of
Legrand/Hager/Siemens make or any other equivallent A catagories reputed make ISI
marked as approved in the existing MCB DB complete with connections. including supply
& transportation of materials from the source to the work site, labour, scaffolding, taxes
& royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Supplying and fixing 63 Amps rating, TPN, 415 volts, RCCB,300mA
Legrand/Hager/Siemens make or any other reputad equevallent A catagories make ISI
marked as approved in the existing MCB DB complete with connections, testing and
commissioning etc. as required. including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
RATE IN WORDS
10
6.00 Nos
RATE IN WORDS
11
20.00 Nos
RATE IN WORDS
12
4 moudle(125mmx75m) 42.00 Nos
RATE IN WORDS
Supplying and fixing following size/ modules, GI box along with modular base & cover
plate for modular switches in recess etc as required. MAKE-Legrand/L&T/Siemens
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant:
Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Legrand/Hager/Siemens
make or any other reputad equevallent A catagories make ISI marked as approved in the
existing MCB DB complete with connections. including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole
and earth metal enclosed plug top alongwith 32 amps. C-series, SP MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for the socket outlet, and
complete with connections, testing and commissioning etc. as required.
Legrand/Hager/Siemens make including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 51
1 moudle(75mmx75m) 33.00 Nos
RATE IN WORDS
12 moudle(200mmx150m) 26.00 Nos
RATE IN WORDS
8 moudle(125mmx125m) 28.00 Nos
RATE IN WORDS
13
40 MM 55.00 mtrs
RATE IN WORDS
50 MM 55.00 mtrs
RATE IN WORDS
14
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/recess including cutting the wall and making good the same in
case of recessed conduit as required.MAKE-KINJAL/AKG including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant:
Supply and fixing modular type indicator on the existing switch box/cover of Anchor
make. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction 14
45.00 Nos
RATE IN WORDS
15
27.00 Nos
RATE IN WORDS
B(Light fitting & Fan)
1
6.00 Nos
RATE IN WORDS
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant:
Supplying and installation of AC starter Moudlar type,L&T make or any other equivalent
reputed make as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod
Box of suitable size including moudlar cover. including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant:
Supplying, installation, of exhaust fan of heavy duty 380 mm sweep with louvers (BAJAJ
make or any other equivalent reputed make as approved) of exhaust fan in the existing
wall, including fixing & conntection. including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant:
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 52
2
10.00 Nos
RATE IN WORDS
3
10.00 Nos
RATE IN WORDS
4
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers (BAJAJ
make or any other equivalent reputed make as approved) of exhaust fan in the existing
wall, including fixing & conntection. including fixing & conntection. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying, installation, testing and commssioning of 900 mm sweep white/milky colour
ceiling fan of BAJAJ Make or any other equivalent reputed make as approved including
wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated,
copper conductor, single core cable etc. As required.(With fan Regulator) including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour
ceiling fan of BAJAJ Make or any other equivalent reputed make as approved including
wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated,
copper conductor, single core cable etc. As required.(With fan Regulator) including
supply & transportation of materials from the source to the work site, labour, scaffolding,
8.00 Nos
RATE IN WORDS
5
16.00 Nos
RATE IN WORDS
6
6.00 No
RATE IN WORDS
Supplying and fixing of concealed LED square light fitting with glass cover, in existing
false ceiling wire guard etc. of 1 x 40 watt LED Fixture,PHILIPS,M-RC171BLED29S-
6500PSEWH220-24050HZ make or any other reputed make of approved quality
including supply and fixing of FTL with connection etc. as required. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour
ceiling fan of BAJAJ Make or any other equivalent reputed make as approved including
wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated,
copper conductor, single core cable etc. As required.(With fan Regulator) including
supply & transportation of materials from the source to the work site, labour, scaffolding,
taxes & royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 53
7
58.00 Nos
RATE IN WORDS
8
42.00 Nos
RATE IN WORDS
9
Supplying and fixing of Concealed type LED fitting with glass cover, wire guard etc. of
15W,1 x 15 watt LED Fixture,PHILIPS,M-DN393LED12S-4000PSUWH make or any
other reputed make of approved quality including supply and fixing of LED with
connection etc. as required.including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Supplying and fixing of surface type LED fitting with glass cover, wire guard etc. of
15W,1 x 15 watt LED Fixture,PHILIPS,M-DN170CLED10S-6500PSUWH make or any
other reputed make of approved quality including supply and fixing of LED with
connection etc. as required. including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Supplying & installation, testing and commissioning of prewired, slim (energy sever)LED
tube light fitting with 1x19w LED tube PHILIPS,MOD-BN108CLED20SPSOLNWWH any
other equivallent reputed make ISI marked as approved) with all accessories and tubes
etc. directly on ceiling/wall on two wooden round block, including connections with 1.5 sq
mm PVC insulated, copper conductor, single core cable etc.as required. including supply
& transportation of materials from the source to the work site, labour, scaffolding, taxes
40.00 Nos
RATE IN WORDS
10
2.00 Nos
RATE IN WORDS
11
8.00 Nos
RATE IN WORDS
& transportation of materials from the source to the work site, labour, scaffolding, taxes
& royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying & installation, testing and commissioning of 144w building focus light (WIPRO
make Type No.PHILIPS ,BVP410LED144CWHENBFGS3XT or any other equivallent
reputed make ISI marked as approved) with all accessories and p/f 1 no 144 watt led
lamp incluiding connection with 2.5sq mm cable etc. as required. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying & installation, testing and commissioning of 5 watt building focus light led type,
(PHILIPS ,CAT-919215850313,14) or any other equivallent reputed make ISI marked as
approved) with all accessories incluiding connection with 2.5sq mm cable etc. as
required. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 54
12
2.00 Nos
RATE IN WORDS
13
2.00 Nos
RATE IN WORDS
14
Supplying & installation, testing and commissioning of 5 mtr LED STRIP LIGHT,4.5W
(PHILIPS ,CAT-915004138001) or any other equivallent reputed make ISI marked as
approved) with all accessories incluiding connection with 1.5sq mm cable etc. as
required. including supply & transportation of materials from the source to the work
site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant
Supplying & installation, testing and commissioning of 26 watt LED GATE LIGHT
luminaries with 26 watt lamp, (HAVELLS,LHLC41126099 or any other equivallent reputed
make ISI marked as approved) with all accessories and p/f 1 no 23 watt CFL lamp (1 x
23W) incluiding connection with 2.5sq mm cable etc. as required. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying & installation, testing and commissioning of 10 watt LED BULKHEAD LIGHT
luminaries with 10 watt lamp, (PHILIPS,M-WT202WP LED 6SCWP SUS1PCP3495) or
any other equivallent reputed make ISI marked as approved) with all accessories and
cable etc. as required. including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
4.00 Nos
RATE IN WORDS
15
35.00 Nos
RATE IN WORDS
SECTION-5
1
2.00 Nos
RATE IN WORDS
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy
gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded
to the nearest 10 cm and 5 cm or less shall be ignored) including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick including accessories,
and providing masonary enclousure with cover plate having locking arrangement and
watering pipe etc. with charcoal and salt complete as required. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 55
2
8.00 Nos
RATE IN WORDS
3
8.00 Cum
RATE IN WORDS
4
55.00 Mtr
RATE IN WORDS
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering
pipe etc. with charcoal/ coke and salt as required.(PANEL-4+LIGHTENING-12,TR-8)
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant
Excavation of all kinds of soil up to 3 meters depth incluiding refilling (Except rocky soil
) including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as
required. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant
5
22.00 Mtr
RATE IN WORDS
6
6.00 Cum
RATE IN WORDS
7
2.00 Cum
RATE IN WORDS
8
2.00 Mtr
Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections
etc. as required. including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant
Refilling/Back filling soft soil with borrowed within a lead of 5 K.M. etc. as required.
including supply & transportation of materials from the source to the work site, labour,
scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction of the
Bank's Engineer/Architect consultant
Excavation of hard-rock up to 3 meters depth including getting out the excavated soil
disposal of the excavated soil as directed with lead of 50 meters. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying and making brick massonary pedastal with extra super structure including
cement plastering etc as required. including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 56
RATE IN WORDS
D(lightening conductor)
1
12.00 Nos
RATE IN WORDS
2
12.00 Nos
RATE IN WORDS
3
Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, copper
tube, having single prong at top, with 85 mm dia 3mm thick copper base plate including
holes etc. complete as required including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Fixing of lightning conductor finial with base plate including holes etc. complete as
required. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant
Jointing copper (with another copper base of the finial or any other metallic object) by
riveting / nut bolting/sweating and soldering etc as required including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
12.00 Nos
RATE IN WORDS
4
55.00 mtrs
RATE IN WORDS
5
102.00 mtrs
RATE IN WORDS
6
12.00 Nos
RATE IN WORDS
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required.(For horizontal run) including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required.(For vertical run) including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm
long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete
as required. including supply & transportation of materials from the source to the work
site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 57
7
12.00 mtrs
RATE IN WORDS
E(CABLING AND END TERMINATION)
1
12.00 Mtr
RATE IN WORDS
12.00 Mtr
RATE IN WORDS
11.00 Mtr
b) 3.5core x 35 sq mm (surface)(POWER PANEL TO UPS I/C PANEL)
c) 3.5core x 35 sq mm (surface)(MDB TO LIGHT PANEL)
Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground
as required. including supply & transportation of materials from the source to the work
site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant
Supplying and laying of one number PVC insulated armoured and PVC sheathed AL.
conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS of following size
cables with in different types laying. including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
a) 3.5 core x 240 sq mm (surface)(s/s to MDB Double RUN,SINGLE RUN FOR DG
SET,EM PANEL,FIRE PANEL,APFC PANEL)
11.00 Mtr
RATE IN WORDS
10.00 Mtr
RATE IN WORDS
42.00 Mtr
RATE IN WORDS
12.00 Mtr
RATE IN WORDS
36.00 Mtr
RATE IN WORDS
11.00 Mtr
RATE IN WORDS
22.00 Mtr
RATE IN WORDS
6.00 Mtr
RATE IN WORDS
b-3) 3.5core x 35 sq mm (in pipe,including supply of pipe)
d) 3.5core x 70 sq mm (surface)(Light POWER supply to FLOOR PANEL NOT
e) 2 core x 4 sq mm (surface)(for BUILDING FOCUS LIGHT)
f) 3.5core x 95 sq mm (surface)(MDB TO POWER PANEL)
a-1) 3.5 core x 240 sq mm (under ground including excavation & refilling)
b-1) 3.5core x 35 sq mm (under ground including excavation & refilling)
c-1) 3.5core x 95 sq mm (under ground including excavation & refilling)
a-3) 3.5 core x 240sq mm (in pipe, including supply of pipe)
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 58
12.00 Mtr
RATE IN WORDS
8.00 Mtr
RATE IN WORDS
12.00 Mtr
RATE IN WORDS
21.00 Mtr
RATE IN WORDS
12.00 Mtr
RATE IN WORDS
15.00 Mtr
RATE IN WORDS
2
c-3) 3.5core x 95 sq mm (in pipe,including supply of pipe)
a-4) 3.5 core x 240 sq mm (open duct)
d-4) 3.5core x 70 sq mm (OPEN DUCT)(To FLOOR PANEL)
b-4) 3.5core x 35 sq mm (open duct)
e-4) 3.5 core x 95 sq mm (open duct)
Supplying and making end termination with brass compression gland and aluminium lugs
for following mentioned size cable. including supply & transportation of materials from
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
3.5 core x240 sq mm 8.00 Nos
RATE IN WORDS
3.5 core x35sq mm 6.00 Nos
RATE IN WORDS
3.5 core x70 sq mm 6.00 Nos
RATE IN WORDS
3.5 core x95 sq mm 2.00 Nos
RATE IN WORDS
3
50 mm dia 12.00 mtrs
RATE IN WORDS
80 mm dia 12.00 mtrs
RATE IN WORDS
F(PANELS)
the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete
with G.I fitting incl. trenching(75 mm depth)and refilling.including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 59
MDB
1
(ii) 02 set of 0-600Amps Ameter with selecter switch & CTS.
(iii) 02 set of 0-500 voltmeter with selecter switch.
iv)04 nos 40 Ka SP VSD with 32A SP MCB.
In commer- 01 number of 630Amps TPN MCCB, (make- L&T, or equivalent reputed
make ISI marked)
Busbar- 04 numbers of 700Amps Electrolytic copper busbar duly sleeved by color coaded
PVC sleeve & supported by suitable size DMC insulator.
Out going- (i) 01 number of 250A C/O. (make- L&T or equivalent reputed make ISI
marked)
(ii) 3 No. 125 amp TP MCCB(make- Legrand or equivalent reputed make ISI
marked)(FOR POWER FLOOR PANEL/AC PANEL)
(iii) 6 numbers 63Amps TPN MCB ((make- Legrand or equivalent reputed make ISI
marked)(FOR UPS,LIGHT PANEL ,EACH FLOOR)
(iv) 02 numbers 32Amps TPN MCB (make- Legrand or equivalent reputed make ISI
marked)( For both light and power supply DB).(v) 02 numbers 40Amps DP MCB (make- Legrand or equivalent reputed make ISI
marked) (For both light and power supply,SPARE)
(vi) 1 No. 160 amp TP MCCB(make- Legrand or equivalent reputed make ISI
marked)(FOR APFC PANEL)
Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented
by simens gray powder cote paint is designed as G.A drawing. (FOR 01 NO OF
TRANSFORMER) including supply & transportation of materials from the source to the
work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the
instruction of the Bank's Engineer/Architect consultant
1.00 Set
RATE IN WORDS
FDB POWER/AC
2
3.00 Set
RATE IN WORDS
(iii) 02 numbers 40Amps DP MCB (make- Legrand or equivalent reputed make ISI
marked) (For both light and power supply,SPARE).
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of 0-100Amps Ameter with selecter switch & CTS.
(iii) 01 set of 0-500 voltmeter with selecter switch.
NB- This panel should have proper earth by suitable rated copper flat.
iv)04 nos 40 Ka SP VSD with 32A SP MCB.
NB- This panel should have proper earth by suitable rated copper flat.
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented
by simens gray powder cote paint is designed as G.A drawing. (FOR EACH FLOOR
POWER,office load power,GF,1F,2F,3F,BMS PANEL) including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant
In commer- 01 number of 125Amps TP MCCB. (make- LEGRAND or equivalent reputed
make ISI marked)
Busbar- 04 numbers of 150Amps Electrolytic copper busbar duly sleeved by color coaded
PVC sleeve & supported by suitable size DMC insulator.
Out going- (i) 02 numbers 63Amps TPN MCB ((make- Legrand or equivalent reputed
make ISI marked)(FOR UPS,POWER DB ,EACH FLOOR)
(ii) 02 numbers 32Amps TPN MCB (make- Legrand or equivalent reputed make ISI
marked)( For both light and power supply DB).
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 60
S/S PANEL
3
1.00 Set
RATE IN WORDS
FDB LIGHT/UPS
4
In commer- 01 number of 63Amps TPN MCB. (make- LEGRAND or equivalent reputed
make ISI marked)
Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coaded
PVC sleeve & supported by suitable size DMC insulator.
S/I/T&Commissioning of LT OUTdoor floor mounted cubical type electrical main panel
(for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted &
pented by simens gray powder cote paint is designed as G.A drawing. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
In commer- 01 number of 630Amps TPN SFU. (make- L&T or equivalent reputed make
ISI marked)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented
by simens gray powder cote paint is designed as G.A drawing. (FOR FLOOR/UPS,light
load in office,SF,GF,1F,2F,3F) including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
2.00 Set
RATE IN WORDS
AREA LIGHT,TIMER PANEL
5
In commer- 01 number of 40A 4P MCB. (make- LEGRAND or equivalent reputed make
ISI marked)
Busbar- 04 numbers of 60Amps Electrolytic copper busbar duly sleeved by color coaded
PVC sleeve & supported by suitable size DMC insulator.
Out going- (i) 01 number TIME SWITCH,01 NO OF 32A TP POWER CONTACTOR
FALLOWED BY, 6-32A SP MCB-12 NOS((make- Legrand or equivalent reputed make
ISI marked)(FOROUT LIGHT CIRCUIT)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of 0-30Amps Ameter with selecter switch & CTS.
(iii) 01 set of 0-500 voltmeter with selecter switch.
PVC sleeve & supported by suitable size DMC insulator.
Out going-02 numbers 32Amps TPN MCB (make- Legrand or equivalent reputed make
ISI marked)( For both light and power supply DB).04 numbers 40Amps DP MCB (make- Legrand or equivalent reputed make ISI marked)
(For both light and power supply,SPARE).
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of 0-60Amps Ameter with selecter switch & CTS.
(iii) 01 set of 0-500 voltmeter with selecter switch.
NB- This panel should have proper earth by suitable rated copper flat.
S/I/T&Commissioning of LT OUTdoor WALL/FLOOR mounted double door type cubical
type electrical main panel ( light ) made out by 2mm CRCA steel sheet duly derusted &
pented by simens gray powder cote paint is designed as G.A drawing. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 61
1.00 Set
RATE IN WORDS
6
1.00 Set
RATE IN WORDS
Out going- (i) 01 number of 100A TP MCCB. (make- Legrand or equivalent reputed
make ISI marked)(FOR ,FIRE PANEL)
(ii) 1No. 63 amp TP MCCB(make- Legrand or equivalent reputed make ISI marked)(FOR
,FLOOR PANEL)
(iii) 04 numbers 63Amps TPN MCB ((make- Legrand or equivalent reputed make ISI
marked)(FOR LIFT,EMERGINCY POINT/SPARE)
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of 0-200Amps Ameter with selecter switch & CTS.
(iii) 01 set of 0-500 voltmeter with selecter switch.
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for
both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented
by simens gray powder cote paint is designed as G.A drawing. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
In commer- 01 number of 160A 4P ATS. (make- LEGRAND or equivalent reputed make
ISI marked)
Busbar- 04 numbers of 300Amps Electrolytic copper busbar duly sleeved by color coaded
PVC sleeve & supported by suitable size DMC insulator. (30 x 10mm. Copper flat)
RATE IN WORDS
G(Telephone & Net cable)
1
158.00 Mtr
RATE IN WORDS
2
145.00 Mtr
RATE IN WORDS
3
25.00 Nos
RATE IN WORDS
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE
insulated, shielded with fine tinned copper braid and protected with PVC sheath in the
existing surface/ recessed steel/ PVC conduit as required including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supply & drawing of the 4 pair,0.5 sqmm telephone cables in existing surface/ recessed
conduit etc. as required. including supply & transportation of materials from the source
to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as
per the instruction of the Bank's Engineer/Architect consultant
Supplying and telephone socket socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 62
4
45.00 No
RATE IN WORDS
5
1.00 No
RATE IN WORDS
6
20.00 No
RATE IN WORDS
Supplying & installation of Information outlet with SMB (make-D-LINK/Roma Equivalent
as approved) in suitable metallic box. including supply & transportation of materials
from the source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Supplying and Commissioning of 100 Line Digital EPABX with maintenance free Battery
Back up. including supply & transportation of materials from the source to the work site,
labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per the instruction
of the Bank's Engineer/Architect consultant
Supplying & Commissioning of Telephone Hand Set. including supply & transportation of
materials from the source to the work site, labour, scaffolding, taxes & royalities, leads &
lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant
Supplying & installation of 100 pair KRONE make moudles with locking & key
arrangements fabricated with MS sheet & poweder coated to be fixed on concealed 7
3.00 No
RATE IN WORDS
H(LAN WIRING)
1
1.00 Sets
RATE IN WORDS
2
1.00 Sets
RATE IN WORDS
3
arrangements fabricated with MS sheet & poweder coated to be fixed on concealed
manner incl. good the damages. including supply & transportation of materials from the
source to the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all
complete as per the instruction of the Bank's Engineer/Architect consultant
Supplying and Commissioning of 6 U Rack with all accessories. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying & Commissioning of Managed Cat 6 24 Port Switch. including supply &
transportation of materials from the source to the work site, labour, scaffolding, taxes &
royalities, leads & lifts, etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
Supplying & Commissioning Cat 6 24 Port Patch Panel. including supply & transportation
of materials from the source to the work site, labour, scaffolding, taxes & royalities, leads
& lifts, etc all complete as per the instruction of the Bank's Engineer/Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................
Page 63
1.00 Sets
RATE IN WORDS
4
Patch Chord CAT 6 One meter
long.25.00 Sets
RATE IN WORDS
Patch Chord CAT 6 Two meter
long.25.00 Sets
RATE IN WORDS
SECTION-5 (OUT SIDE SOLAR STREET LIGHT)
1
6.00 Sets
RATE IN WORDS
Supplying and fixing:( including supply & transportation of materials from the source to
the work site, labour, scaffolding, taxes & royalities, leads & lifts, etc all complete as per
the instruction of the Bank's Engineer/Architect consultant)
Supplying, Erection, Fixing, connection & testing of Solar Powdered Street Light of
SUKAM/Halomix or equvalant reputed make ISI marked as approved make with
specification LED Luminarie 15 Watt Solar PV module 50 Watt Charge Controller 60
Watt Pole 6 meter Velmond make maintenance free tublar plate Battery with suitable
Box 12 Volt 75 Ah. etc all complete as per the instruction of the Bank's
Engineer/Architect consultant
2
8.00 Sets
RATE IN WORDS
3
88.00 mtrs
RATE IN WORDS
4
55.00 mtrs
RATE IN WORDS
TOTAL
Supplying, Erection, Fixing, connection & testing of 20W LED Street Light of
PHILIPS,model-BKP 022 LED 21.CWMR S1 PSU GR or equvalant reputed make ISI
marked as approved Model mounted with moveable braket fixed in side wall of building.
etc all complete as per the instruction of the Bank's Engineer/Architect consultant
Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed
make,ISI marked with all other concerned materials. etc all complete as per the
instruction of the Bank's Engineer /Architect consultant
Supplying,laying of 3cx4sq.mm copper flexible cable with insulated cover of reputed
make,ISI marked with all other concerned materials for submerssible pump. etc all
complete as per the instruction of the Bank's Engineer /Architect consultant
Signature of the Contractor with Seal
No of Correction..........................
No of over writting...........................