octiv range

12
OCTIV | RANGE “The Octiv Range of inline RF power delivery and plasma diagnostic systems provide versatility along with micro- second resolution”

Upload: impedans-ltd

Post on 25-Jun-2015

146 views

Category:

Technology


1 download

DESCRIPTION

Slight changes in power, as a plasma input parameter, can affect the quality of a substrate. Monitoring the voltage, current, phase and harmonic information can result in better process stability. The Octiv range provides a set of diagnostic tools that give highly accurate insights to RF parameters.

TRANSCRIPT

Page 1: Octiv Range

OCTIV | RANGE

“The Octiv Range of inline RF power delivery and plasma diagnostic systems

provide versatility along with micro-second resolution”

Page 2: Octiv Range

Real Power

Forward Power

Reflected Power

Impedance Voltage Current PhaseAngle

HarmonicsSimultaneous

Measurements Ion Flux

Waveform Reconstruction

Mono • • • •

VI • • • • • • • •

Poly • • • • • • • • •

Suite • • • • • • • • • • •

OCTIV | RANGE

Page 3: Octiv Range

OCTIV | RANGE

Hardware

Electronics and SoftwareStandalone intelligent RF power delivery and plasma

diagnostic system.Optional benchtop RF power meter display unit.

Operating ParametersPower Range: 0 – 12 kW

Standard Calibration Frequencies: 2MHz | 13.56MHz | 27.12MHz | 40.68MHz | 60MHz

Hardware SpecificationsConnector Types: N-Type, 7/16 or custom

ConnectivityUSB

Serial RS232

Page 4: Octiv Range

OCTIV | MONO

The Octiv Mono is an in-line RF power meter and RF power sensor

measurement system. It measures a single fundamental frequency and has an accuracy rating of 1% and a time

resolution of 1µs.

Plasma Diagnostics MeasuredReal Power

Forward PowerReflected Power

Impedance

Measurement FunctionalityTime AveragedTime Resolved

Time TrendSmith Chart Measurements

Page 5: Octiv Range

OCTIV | MONO

Installation Setup

Generator Match Plasma Reactor

Computer

Octiv Mono

Page 6: Octiv Range

OCTIV | VI

The Octiv VI probe system is an in-line RF measurement system. It can measure a single fundamental

frequency and its harmonics at 1% accuracy and 1µs time resolution.

Plasma Diagnostics MeasuredVoltageCurrentPhase

HarmonicsImpedance

Measurement FunctionalityTime AveragedTime Resolved

Time TrendSmith Chart Measurements

Page 7: Octiv Range

OCTIV | VI

Installation Setup

Generator Match Plasma Reactor

Computer

Octiv VI Probe

Page 8: Octiv Range

OCTIV | POLY

The Octiv Poly is a multi-frequency in-line RF measurement system. It can

measure multiple fundamental frequencies and harmonics

simultaneously and has an accuracy of 1% with 1µs time resolution.

Plasma Diagnostics MeasuredVoltageCurrentPhase

HarmonicsImpedance

Measurement FunctionalityTime AveragedTime Resolved

Time TrendSmith Chart Measurements

Page 9: Octiv Range

OCTIV | SUITE

The Octiv Suite is an in-line multi-frequency RF system with plasma diagnostic and complex waveform

analysis with an accuracy of 1% and 1µs time resolution.

Plasma Diagnostics MeasuredVoltageCurrentPhase

HarmonicsImpedance

Ion Flux

Measurement FunctionalityTime Averaged • Time Resolved

Time Trend • Smith Chart MeasurementsWaveform Reconstruction

Page 10: Octiv Range

OCTIV | RANGE

Applications

As effective tools for plasma measurement, Octiv systems excel at extracting power delivery information and plasma parameters for better

process stability.

The Octiv Systems can be used in the following applications:Atmospheric

Dusty PlasmaPlasma Etching

PECVD Space Plasma

Plasma Sputtering

Page 11: Octiv Range

OCTIV | RANGE

For further infromation on the Octiv Range visitwww.impedans.com/octiv_range

As effective tools for plasma measurement, Octiv systems excel at extracting power delivery information for better process stability.