occupancy sensors 59-65

7
59 WattStopper Sensornry system The most advanced energy saving technology OCCUPANCY SENSORS The NEW generation of occupancy sensors: Legrand’s new generation of occupancy sensors are packed with features and options that streamline sensor installation and strengthen performance - yet fit in a small, clean package. Passive Infra Red Ultrasonic Dual technology

Upload: demo-only

Post on 12-Nov-2014

23 views

Category:

Documents


4 download

TRANSCRIPT

59

WattStopper Sensornry systemThe most advancedenergy saving technology

OCCUPANCY SENSORS

The NEW generation ofoccupancy sensors:Legrand’s new generation ofoccupancy sensors are packed with featuresand options that streamline sensor installation and strengthen performance - yet fit in a small,clean package.

Passive Infra Red

Ultrasonic

Dual technology

60

Pak No. Kat. WPIR Wall mount Logic Key / On bypass Multi-level lens Adjustable time delay of 30s to 30 min Dimensions : 64 x 64 x 28 mm 1 WPIR 24 V DC, 14 mA, Coverage : 28m2

CX series Wall mount Choice of 4 coverage patterns Digital time delay of 15 s to 30 min Dimension : 83.8 x 83.8 x 53 mm 1 CX-100-0 24 V DC, 19 mA, Coverage : 185.8 m2, with light level and isolated relay 1 CX-100-1 24 V DC, 19 mA, Coverage : 27,4 m linear with light level and isolated relay 1 CX-105-0 24 V DC, 8 mA Coverage : 185,8 m2

1 CX-105-1 24 V DC, 8 mA Coverage : 27,4 m linear

Passive infrared occupancy sensors

Wiring diagramWPIR

Occupancy controlled lighting

Multiple sensors and lighting

Advanced PIR technologyAdjustable sensitivityLED indicator

CI series Ceiling mount 360o coverage choice of 2 coverage patterns Digital time delay of 15 s to 30 min Dimension : 85 x 56 mm (diameter x depth) 1 CI-200 24 V DC, 20 mA, Coverage : 112 m2, with light level and isolated relay 1 CI-200-1 24 V DC, 20 mA, Coverage : 46,5 m2, with light level and isolated relay 1 CI-205 24 V DC, 11 mA, Coverage : 112 m2

1 CI-205-1 24 V DC, 11 mA, Coverage : 46,5 m2

Remark : All 24V DC sensor must be used with power pack B230E-P Remark : Master switch & By-pass switch are optional

Passive infrared occupancy sensors

Coverage patternWPIR

WPIR CX Series CI Series

Zone 5 Zone 4 Zone 3 Zone 2 Zone 1 8Ó -1ft 1ft 4 ft 8ft 15ft

61

Passive infrared occupancy sensors

Coverage pattern

CX Series

Coverage pattern

CI Series

Wiring diagram

CI-200, CI-200-1, CI-205, CI-205-1

Wiring diagram

CX series

Remark : Master switch & By-pass switch are optional

62

Ultrasonic occupancy sensors Ultrasonic occupancy sensors

Pak No. Kat. WT series Ceiling mount ultrasonic technology with 32 kHz frequency Choice of 4 coverage patterns DIP switch override; digital time delay 15 s to 30 min Dimensions : 122 x 38 mm 1 WT-605 24 V DC, 37 mA Coverage : 360o one-sided, 55,7 m2

1 WT-600 24 V DC, 27 mA Coverage : 360o one-sided, 55,7 m2

with isolated relay 1 WT-1105 24 V DC, 30 mA Coverage : 360o two-sided, 102,2 m2

1 WT-1100 24 V DC, 40 mA Coverage : 360o two-sided, 102,2 m2

with isolated relay 1 WT-2205 24 V DC, 30 mA Coverage : 360o two-sided, 204,4 m2

1 WT-2200 24 V DC, 40 mA Coverage : 360o two-sided, 204,4 m2

with isolated relay 1 WT-2255 24 V DC, 30 mA Coverage : 360o two-sided, 27,4 m linear 1 WT-2250 24 V DC, 40 mA Coverage : 360o two-sided, 27,4 m linear with isolated relay

Omni-directional transmission (360o coverage)Adjustable sensitivityLED indicator

WT Series UT Series

Wiring diagram

WT series

Coverage pattern

WT series

Remark : All 24V DC sensor must be used with power pack B230E-P Remark : Master switch & By-pass switch are optional

UT series Ceiling mount ultrasonic technology with 40 kHz technology Choice of 3 coverage patterns Smart set can adjust automaticaly sensitivity and time delay 24 V DC, 43 mA Dimensions : 144,3 x 25,9 mm (diameter x depth) 1 UT-300-1 Coverage : 360o, 46,5 m2

1 UT-300-2 Coverage : 360o, 92,9 m2

1 UT-300-3 Coverage : 360o, 185,8 m2

UT sries

63

Dual technology occupancy sensors

Combined PIR and ultrasonic technologyBuilt-in light level sensorAdjustable sensitivityLED indicator

Dual technology occupancy sensors

Pak No. Kat. DT-2 series SmartSet can adjust automatically sensitivity and time delay SmartSet (automatic) time delay or fixed 5 sec. to 30 min SmartSet (automatic) or reduced sensitivity Dimensions : 110 x 86 x 50 mm

1 DT-200 24 V DC, 37 mA Coverage : 185,8 m2, with light level and isolated relay 1 DT-205 24 V DC, 27 mA Coverage : 185,8 m2

DT-3 series SmartSet can adjust automatically sensitivity and time delay SmartSet (automatic) time delay or fixed 5 sec. to 30 min SmartSet (automatic) or reduced sensitivity Terminal wiring Dimensions : 114 x 26 mm

1 DT-300 24 V DC, 43 mA Coverage : up to 92,9 m2

with light level and isolated relay 1 DT-305 24 V DC, 35 mA Coverage : up to 92,9 m2

DT-2 Series DT-3 Series

Wiring diagram

DT-2 series

DT-3 series

Coverage pattern

DT-2 series

DT-3 series

40 ft x 40 ft(12.2m x 12.2m)

Remark : All 24V DC sensor must be used with power pack B230E-P Remark : Master switch & By-pass switch are optional

64

dual technology occupancy sensorsSensors accessories Sensors accessories

Pak No. Kat. Power pack Easy snap-in installation Contains isolated relay with NO contacts Dimensions : 45 x 70 x 38 mm3

1 B230E-P Primary : 220 - 240 V AC Secondary : 24 V DC, 150 mA 1 S120/277/ Auxiliary pack input voltage 120/277/347 VAC 347E-P Load rating Ballast (A) 20/20/15

Intelli timer logger Lithium battery, 10-year average life PIR technology Adjustable sensitivity Recessed reset switch Stores up to 4096 entries Allow to make an estimation of the potential energy saving in a room. 1 IT-200 Occupancy and light logger PC connector cable inluded

B230E-P IT-200

Wiring and installation diagramConnection to a power pack

IT-200 Specifications

Sample Logger Reports

• PIR technology• Lithium battery ; 10 year average life• Test button to activate occupancy and light level LEDs for 90 seconds• Adjustable sensitivity

• Recessed reset switch• Stores up to 4096 entries• Stores site name to identify area being monitored• Connects to PC for data retrial

IT - 200 Controls

Remark : All 24V DC sensor must be used with power pack B230E-P

Light pipe

Occupancysensor lens

Light levelsensitivityadjustment

Test button(activates LEDs)

Green LED (light)

Data connectorport

Red LED(occupancy)

Reset button

Graphs of Lighting/Occupancy for Office Suite #301

Date of Entries Midnight 06:00 AM

MondayJanuary 8

Noon 06:00 PM

graph indicates Monitored Area Lit graph indicates Monitored Area Occupied

Entries: 42From: Sun,Aug 14, 1995 at 12:00:00 PMTo: Thu, Aug 18, 1995 at 9:32:00 PM

Cost/kWhr : $0.080HVAC Adder : 15%Load Size : 180W

1 Sun, Aug 14, 1995 at 12:00:00 PM Lights ON Occupied2 Sun, Aug 14, 1995 at 2:25:00 PM Lights ON Vacant3 Mon, Aug 15, 1995 at 7:50:00 AM Lights ON Occupied4 Mon, Aug 15, 1995 at 10:15:00 AM Lights ON Vacant5 Mon, Aug 15, 1995 at 10:50:00 AM Lights ON Occupied6 Mon, Aug 15, 1995 at 12:15:00 AM Lights OFF Vacant

LIGHTING/OCCUPANCY SUMMARY

ON+Occupied: 59.81 hours 17.8%

ON+ Vacant: 80.64 hours 24.0%

OFF+ Occupancy 0 hours 0.0%

OFF+ Vacant: 195.55 hours 58.2%

65

dual technology occupancy sensorsDay-lighting control sensors

Pak No. Kat. Day-lighting control sensors 2 V DC (min) to 10 V DC (max) output voltage Control range of 210 to 640 lux Controls up to 50 standard dimming ballasts Coverage 60o cone Dimensions : 60 x 22 mm 1 LS-301 Dimming light level sensor with adjustment via handheld remote control 24 V DC, 30 mA 1 LSR-301-S Set up remote control 1 LSR-301-P Occupant remote control

Combined PIR technologyBuilt-in light level sensorAdjustable sensitivityLED indicator

Day-lighting control sensors

Wiring diagramLS-301 day-lighting control sensors

LS-301 day-lighting and CI series occupancy sensors

Remarks : Master switch & By-pass switch are optional

LS-301 LSR-301-P LSR-301-S

151