NTS Facility Spotlight: Chicago, IllinoisSpecializing in EMC, Environmental and Mechanical Testing
Our state-of -the-ar t laborator y is posit ioned just outside downtown Chicago
Mult iple EMI/EMC test chambers including a 5m oversized unit
Discover the robustness of your product after exposure to harsh environments
About NTS ChicagoNTS Chicago features a 40,000 square foot state-of-the-art facility in Mt. Prospect, IL. We
have over thirty years’ experience partnering with customers to provide signi� cant gains in
compliance, reliability and durability. Our team guides your product through testing while
providing seamless communication and program management. We have your solution to
quali� cation requiring both EMC and environmental simulation requirements such as military,
avionics, automotive, off-road automotive and aerospace.
This location houses full EMC/EMI capabilities and blowing sand/blowing dust testing to
complement our long-standing environmental capabilities such as vibration, thermal shock and
cycling, temperature humidity, acceleration, corrosion, altitude and HALT/HASS. With the addition
of these capabilities, we can now offer a one-stop-shop solution to partner companies who want
to get their compliant products to market quickly and ef� ciently.
EMI/EMC/ESD Testing
5-meter semi-anechoic chamber with 10’x10’ door, 12,000 lb capacity turntable, vehicle exhaust system and troubleshooting projection screen inside the chamber
Four EMI test chambers
Reverberation Chamber for testing above 400MHz
Large, sectioned ground plane with pre-con� gured commercial immunity stations for expedited testing
Full vehicle automotive testing
Automotive Testing to JDQ 53.3, JDQ 202, JDQ 203, load dumps, transients
Commercial Product Testing – FCC, EMC Directive, CISPR, 61000-X-X
Medical Directive Testing – 60601-1-2
Military MIL-STD-461 (D,E,F)
Avionics RTCA/DO-160 ( D,E,F,G)
Other customer standards as requested
Dynamics Testing
25,000, 18,000 and 6,500 force pound electrodynamic shakers
Vibration at Temperature
Constant Acceleration/Centrifuge
Loose Cargo Vibration
ISTA Package Testing
HALT/HASS Chambers (30”x30”x30” and 48”x48”x48”)
Package Drop
Chemical Testing
Copper-Accelerated Acetic Acid-Salt Spray (CASS)
Chemical Compatibility
Chemical Resistance
Contamination by Fluids
Fluid Compatibility
Fluid Immersion
Fluid Resistance
Fluid Susceptibility
Porosity
Salt Spray/Fog/Mist
Solderability
www.nts.com1.800.270.2516
NTS Facility Spotlight: Chicago, IL
Specializing in EMC, Environmental and Mechanical Testing
Determine rel iabi l ity with thermal shock testing
Our chemical engineers can offer a myriad of solutions for the most complicated chal lenges
NTS Chicago's exper tise in HALT testing wil l f ind the l imits and discover the weak l inks of your products and systems
Environmental Simulation Temperature/Humidity Testing
– 9 standing chambers
– 2 walk-in chambers up to 11’x12’
– Temperature ranges -70 to 130 degrees C
– Humidity control throughout condensing range of 5 to 90 degrees C
Altitude Chamber
– 100,000 ft. with temperature -55 to 150 degrees C
– Rapid Decompression, Explosive Decompression
Thermal Shock/Thermal Cycling
– 9 Single-Zone Thermal Cycling Chambers (varying sizes up to 36”x36”x36”)
– 10 Dual-Zone Thermal Shock Chambers (20”x20”x18” test volume) -75 to 200 degrees C
– Large Dual-Zone Thermal Shock Chamber (42”x42”x42”) test volume
Sand and Dust
– Blowing Sand: Wind speed > 18 m/s, ambient at 55 degrees C
– Blowing Dust: Wind speed from 1.5 m/s to over 20 m/s at ambient and 55 degrees C
– Settling Dust per IP5X and IP6X (under pressure)
Ingress Protection IPXX, levels 1 through 9k
– Water Spray/Water Jetting, NEMA 250 Hosedown
Icing/Freezing Rain
Explosive Atmosphere
Salt Fog
CASS Testing
Solar Radiation
Gravel Bombardment
Advanced Cycling and Abrasion Testing
Flammability
Electrical Testing
AC/DC High Voltage
Automation - High Speed Data Acquisition
Capacitance
Continuity Monitoring
Current Measure
Dielectric Strength
Dissipation Factor (Tam Delta)
DWV - Dielectric Withstand Voltage
High Pot
Inductance
Insulation Resistance
Leakage Current
Low-level Contact Resistance
Moisture Insulation Resistance
Power & Current Cycling
Q Factor
Resistance
Resistance Temp Coef� cient
Surface/Volume Resistivity
UN/IATA Battery Testing
Voltage Drop
Mechanical Testing
Abrasion
Adhesion
Bend
Breaking Force/Strength
Cable Endurance
Compression/ Compression Set
Durometer Hardness
Fatigue Life
Insertion/Engaging/Withdrawl
Mechanical Durability/Cycling
Peel Strength
Push/Pull/De� ection
Resistance to Solder Heat
Separating Force
Shear/Lap Shear
SolidWorks Fixture Design
Strain Gauge
Tensile/Elongation/Flex
Torque/Torsional Strength
Lab Accreditations and Evaluations
NTS Chicago is accredited to ISO 17025 through A2LA, certi� cate numbers 0214.38 and 0214.39
About NTSNational Technical Systems (NTS) provides test, inspection and certi� cation services to help
clients build better, stronger, safer, more reliable products and bring those products to market
quickly and ef� ciently. NTS engineers and technicians have extensive knowledge of current test
and conformity requirements, both domestic and international over a range of industries including
aerospace, defense, telecom and energy.