CITY OF FULLERTON SEWER NOTES (PUBLIC):
NOTE:THESE PLANS ARE APPROVED ONLY FOR WORK WITHIN PUBLICRIGHT-OF-WAY. ALL OTHER SEWER FACILITY IMPROVEMENTS THAT ARETO BE LOCATED ON-SITE SHALL BE INSTALLED IN COMPLIANCE WITH THEREQUIREMENTS OF THE CALIFORNIA BUILDING CODE, APPLICABLE STATEAND CITY OF FULLERTON CODES AND ORDINANCES. VERIFICATION OFFULL COMPLIANCE SHALL REST ON THE LICENSURE ANDPROFESSIONALISM OF THE ARCHITECT OF RECORD AND THE CIVILENGINEER OF RECORD, WHO ARE RECOGNIZED AGENTS OF THEDIVISION OF THE STATE ARCHITECT. THE PROPER INSTALLATION OF THISUNDERGROUND UTILITY SHALL BE MONITORED AND INSPECTED BY ALICENSED DSA INSPECTOR OF RECORD WHO SHALL BE RESPONSIBLE FORREPORTING DIRECTLY TO THE ARCHITECT OF RECORD AND THEENGINEER OF RECORD.
®
Phone: 714.665.4500
Tustin California 92780-1947
17782 17th Street Suite 200
Sa
ve
D
ate
:
Plo
t D
ate
:
By:
By:
File
:
SEWER CONSTRUCTION NOTES
UTILITY TRENCH & PAVEMENT REMOVAL.WIDTH AS REQUIRED FOR DEPTH OF UTILITY.
NOTE:THESE PLANS ARE APPROVED ONLY FOR WORK WITHIN PUBLICRIGHT-OF-WAY. ALL OTHER SEWER FACILITY IMPROVEMENTS THAT ARETO BE LOCATED ON-SITE SHALL BE INSTALLED IN COMPLIANCE WITH THEREQUIREMENTS OF THE CALIFORNIA BUILDING CODE, APPLICABLE STATEAND CITY OF FULLERTON CODES AND ORDINANCES. VERIFICATION OFFULL COMPLIANCE SHALL REST ON THE LICENSURE ANDPROFESSIONALISM OF THE ARCHITECT OF RECORD AND THE CIVILENGINEER OF RECORD, WHO ARE RECOGNIZED AGENTS OF THEDIVISION OF THE STATE ARCHITECT. THE PROPER INSTALLATION OF THISUNDERGROUND UTILITY SHALL BE MONITORED AND INSPECTED BY ALICENSED DSA INSPECTOR OF RECORD WHO SHALL BE RESPONSIBLE FORREPORTING DIRECTLY TO THE ARCHITECT OF RECORD AND THEENGINEER OF RECORD.
PRIVATE SEWER OWNED ANDMAINTAINED BY FULLERTON COLLEGE
PRIV
ATE
SEW
ER O
WN
ED A
ND
MA
INTA
INED
BY
FULL
ERTO
N C
OLL
EGE
EXISTING STORAGE CONTAINERS TO BE RELOCATED TO PARKING LOT C WEST PER THE DIRECTION OF THE CAMPUS.CONTAINERS TO BE RELOCATED BACK TO ORIGINAL LOCATION UPON COMPLETION OF PROJECT.
SIDEWALK DETAIL
#3 REBAR @ 18"O.C. EACH WAY
5" PCC PAVEMENT
4" AGGREGATE BASE
MID DEPTH
MIN. 18" BELOW FINISH SURFACE, MOISTURECONDITIONED AND COMPACTED TO 90% OFASTM D-1557. EXTEND OVEREXCAVATIONMIN. 2' BEYOND IMPROVEMENTS.
FIRE LANE CONCRETE PAVING DETAIL
#4 REBAR @ 12"O.C. EACH WAY
6" PCC PAVEMENT
4" AGGREGATE BASE
MID DEPTH
AGGREGATE BASE COMPACTED TO 95% OFASTM D-1557. AGGREGATE BASE SHOULD BEIN ACCORDANCE WITH THE CALTRANSCLASS II BASE (MINIMUM R-VALUE=78) TO BETESTED BY SOILS ENGINEER PRIOR TODELIVERY.
MIN. 18" BELOW FINISH SURFACE, MOISTURECONDITIONED AND COMPACTED TO 90% OFASTM D-1557. EXTEND OVEREXCAVATIONMIN. 2' BEYOND IMPROVEMENTS.
AGGREGATE BASE COMPACTED TO 95% OFASTM D-1557. AGGREGATE BASE SHOULD BEIN ACCORDANCE WITH THE CALTRANSCLASS II BASE (MINIMUM R-VALUE=78) TO BETESTED BY SOILS ENGINEER PRIOR TODELIVERY.
FIRE LANE ASPHALT PAVING DETAIL
4" AC PAVEMENT
10" AGGREGATE BASE
MIN. 12" BELOW AGGREGATE BASE,MOISTURE CONDITIONED AND COMPACTEDTO 90% OF ASTM D-1557. EXTENDOVEREXCAVATION MIN. 2' BEYONDIMPROVEMENTS.
AGGREGATE BASE COMPACTED TO 95% OFASTM D-1557. AGGREGATE BASE SHOULD BEIN ACCORDANCE WITH THE CALTRANSCLASS II BASE (MINIMUM R-VALUE=78) TO BETESTED BY SOILS ENGINEER PRIOR TODELIVERY.
3/4" MAX. ASPHALT PAVEMENTCOMPACTED TO 95% OF OF ASTM D-2726
CLEAN OUT DETAIL
ELEVATION
AA
PAVED AREA GRASS AREA
COVER FLUSH W/PAVEMENTAC PAVEMENT
CAST IRON COVER
4-3/4" DIA. HOLES
CONCRETE COLLAR TOBE SQUARE
CLASS "B" CONCRETECOLLAR
TOP OF GROUND
6"
3" ABOVE GROUND
CLASS "B" CONCRETECOLLAR FRAME & COVER
BROOKS PRODUCTNO. 3 RT OREQUAL
9"10"
4" MIN.
8"
SAND BACKFILL
UNDISTURBED SOIL
1-2' JOINT
1/8 BEND
2'-2
"
D/2+6"
9"
3"3"
MIN. REQUIRED 3/4"ROCK SUPPORTBACKFILL AREA
VARIES
®
Phone: 714.665.4500
Tustin California 92780-1947
17782 17th Street Suite 200
Sa
ve
D
ate
:
Plo
t D
ate
:
By:
By:
File
:
TITUS MANHOLE FRAME AND COVER
PROVIDE TWISTLIFT SECURITY HANDLE
TITUS MANHOLE FRAME AND COVER WITHTWISTLIFT SECURITY HANDLE PER DETAIL BELOW
2600 SERIES OR 1040 SERIES
NOTE:THESE PLANS ARE APPROVED ONLY FOR WORK WITHIN PUBLICRIGHT-OF-WAY. ALL OTHER SEWER FACILITY IMPROVEMENTS THAT ARETO BE LOCATED ON-SITE SHALL BE INSTALLED IN COMPLIANCE WITH THEREQUIREMENTS OF THE CALIFORNIA BUILDING CODE, APPLICABLE STATEAND CITY OF FULLERTON CODES AND ORDINANCES. VERIFICATION OFFULL COMPLIANCE SHALL REST ON THE LICENSURE ANDPROFESSIONALISM OF THE ARCHITECT OF RECORD AND THE CIVILENGINEER OF RECORD, WHO ARE RECOGNIZED AGENTS OF THEDIVISION OF THE STATE ARCHITECT. THE PROPER INSTALLATION OF THISUNDERGROUND UTILITY SHALL BE MONITORED AND INSPECTED BY ALICENSED DSA INSPECTOR OF RECORD WHO SHALL BE RESPONSIBLE FORREPORTING DIRECTLY TO THE ARCHITECT OF RECORD AND THEENGINEER OF RECORD.