non electric trunk detonator sheet products/detonator v0617 warning enaex services s.a. is...

2
DESCRIPTION It consists of a shock tube, length determined by the blast design, assembled to a surface Milli delay detonator at one end. The free end of the shock tube is sealed and contains a blue cobra connector. The detonator is housed in a block plastic connector that is color coded, according to the delay of the detonator. CHARACTERISTICS • Blue cobra connector. Delay time and length of the tube in the shock tube. • Block type connector color-coded, capable of containing 6 tubes. Assembled Detonator, Non Electric Class 1.1 B NU: 0360 HDS-DET-01 PACKAGING • Box dimensions: 560 x 290 x 260 (mm x mm x mm) • Gross weight of the box: 18.9 Kg • Net weight of the box: 18.0 Kg * For other lengths, consult with Enaex Services • Shock tube with a minimum of 25 Kg of tensile strength, resistant to high and low temperatures, oil resistant in ANFO for 4 days at 40°C, water resistant. • Reliable initiation of shock tubes in both directions. • The initiation signal propagates in the tube through folds, curves, knots and ligatures. • The tube remains intact after use. PRODUCT RANGE LENGTH OF THE SHOCK TUBES The minimum length is 2.4 m and maximum of 30.4 m. Length (m) 2.4 – 3.0 4.2 – 4.8 6.0 7.3 9.0 10.0 12.2 15.2 Unit / Box 240 190 150 140 120 110 90 80 INITIATION Enaex's Non Electrics Trunk Detonators may be initiated with any of the products described below: • Electric Detonators. • Electronic Detonators. • Detonating cords (with a minimum of 3 g PEN / m). • Enaex non-electric Dual detonators. RECOMMENDATIONS FOR USE • Handle with care. Damage to connector, to block or tube can cause mis es. • Always keep the detonators pointing in your opposite direction. • Severe impacts on the detonator may result in a premature detonation. • Never connect the blast or shot before completing the loading operations and personnel have been removed from the area. Data Sheet Products/Detonator V0617 WARNING ENAEX SERVICES S.A. is responsible only as expressly stated in this catalog, in shall in no event be liable for damages, losses or any contingency arising from the use of the products, except those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. ENAEX SERVICES S.A. reserves the right to introduce to its products all those changes deemed appropriate without prior notice. Non Electric Trunk Detonator TRANSPORT INFORMATION B

Upload: buikien

Post on 16-May-2019

230 views

Category:

Documents


0 download

TRANSCRIPT

DESCRIPTION It consists of a shock tube, length determined by the blast design, assembled to a surface Milli delay detonator at one end. The free end of the shock tube is sealed and contains a blue cobra connector. The detonator is housed in a block plastic connector that is color coded, according to the delay of the detonator.

CHARACTERISTICS • Blue cobra connector. Delay time and length of the tube in the shock tube.

• Block type connector color-coded, capable of containing 6 tubes.

Assembled Detonator, Non Electric Class 1.1 B NU: 0360

HDS-DET-01

PACKAGING

• Box dimensions: 560 x 290 x 260 (mm x mm x mm)

• Gross weight of the box: 18.9 Kg

• Net weight of the box: 18.0 Kg

* For other lengths, consult with Enaex Services

• Shock tube with a minimum of 25 Kg of tensile strength, resistant to high and low temperatures, oil resistant in ANFO for 4 days at 40 ° C, water resistant.

• Reliable initiation of shock tubes in both directions.

• The initiation signal propagates in the tube through folds, curves, knots and ligatures. • The tube remains intact after use.

PRODUCT RANGE

LENGTH OF THE SHOCK TUBES

The minimum length is 2.4 m and maximum of 30.4 m.

Length (m)

2.4 – 3.0

4.2 – 4.8

6.0

7.3

9.0

10.0

12.2

15.2

Unit / Box

240

190

150

140

120

110

90

80

INITIATION

Enaex's Non Electrics Trunk Detonators may be initiated with any of the products described below: • Electric Detonators .

• Electronic Detonators. • Detonating cords (with a minimum of 3 g PEN / m). • Enaex non-electric Dual detonators.

RECOMMENDATIONS FOR USE

• Handle with care. Damage to connector, to block or tube can cause mis es. • Always keep the detonators pointing in your opposite direction. • Severe impacts on the detonator may result in a premature detonation. • Never connect the blast or shot before completing the loading operations and personnel have been removed from the area.

Data Sheet Products/DetonatorV0617

WARNINGENAEX SERVICES S.A. is responsible only as expressly stated in this catalog, in shall in no event be liable for damages, losses or any contingency arising from the use of the products, except those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. ENAEX SERVICES S.A. reserves the right to introduce to its products all those changes deemed appropriate without prior notice.

Non Electric Trunk Detonator

TRANSPORT INFORMATION

B

Data Sheet Products/DetonatorV0617

WARNINGENAEX SERVICES S.A. is responsible only as expressly stated in this catalog, in shall in no event be liable for damages, losses or any contingency arising from the use of the products, except those expressly indicated by the current Chilean legislation. The use of explosives is regulated in each country by its own laws. ENAEX SERVICES S.A. reserves the right to introduce to its products all those changes deemed appropriate without prior notice.

Non Electric Trunk Detonator

STORAGE

• Store in a cool, dry right place. • Comply with legal requirements concerning the storage of your location. • The shelf life is 36 months from the date of manufacture. • Temperatures above 90 ° C can cause spontaneous explosions. • Always Rotate stocks ( rst in, rst out).

DELAYS

APPLICATIONS

Non Electric Trunk detonators are used in all mining applications providing additional delay options for the blasting designs or between such designs.

SAFETY

The shock tube cannot be initiated by:

• Radio frequency transmissions.

• Parasitic or stray currents.

• Electrostatic discharge.

• Burning / heat.

SERIES MS

Delay (ms)

0

9

17

25

35

42

65

100

130

Block Color

Black

White

Blue

Orange

Green

Yellow

Red

Black

Green

• Friction. LIMITS OF LIABILITY This information summarizes the best knowledge on the product's

capabilities at the date of issue. Each user must st check the technical

data sheet and in the context of how it intends to use the product. For

further information on this product and storage, please contact Enaex

through your service and / or supply administrator to the telephone: + 56

2 837 7777 or email: [email protected]

BENEFITS

• Combined trunk line and delays .

• Suitable pyrotechnic delay accuracy.

• Easy to use, fast and secure connections.

• Highly visible components.

• Reliable.

• Low noise levels.