newport harbor mate with pedestal installation instructionscamp mate: with the breakers off, insert...
TRANSCRIPT
Eaton Electrical Inc. strongly recommends that theseproducts be installed by a qualified electrician.
IMPORTANT - INSTALL EQUIPMENT IN CONFORMANCEWITH CODES
This product must be installed in accordance with the NationalElectric Code (NEC) or the Canadian Electrical Code (CEC0 andany applicable local codes. Before installing equipment, checkwith your local electrical inspector for requirements and infor-mation. If you have questions or need assistance, contact aqualified electrician.
Installation Instructions for the Newport Harbor Mate with Pedestal Installation Instructions for the Newport Camp Mate with Pedestal Rev. 2 1/30/13
Turn off or disconnect the power supplying this equipment before beginning work.
This may require that you contact your electric utility todisconnect power to an existing load-center. The lineside of the main breaker is energized unless power isdisconnected upstream. Eaton Electrical, Inc. will notassume responsibility for property damage or personalinjury resulting from misuse of the information in thispublication.
Hazardous voltage. Can cause severe in-jury or death.
Turn off main power before opening panel.
Installation
Note
We strongly recommend that a qualified elec-trical contractor install this unit.
Mounting the Unit
Note
Always use stainless steel mounting hardware.
The four corner 5/8” holes in the bottom ofthe pedestal base allows for securing thepedestal to a surface with lag screws, expan-sion bolts, or threaded studs. Conduit shouldbe run through the center of the concrete,sufficient for electrical, water, phone, andcable TV.
Connecting Power Supply to the BussBars on the Newport Pedestal
Remove the screws on the front side of thepedestal and remove the front cover to exposethe buss bars. Connect to buss bars followingthe wire instructions (i.e. Line 1, Line 2,neutral, and ground). Reinstall the cover and screws.
Phone/Cable TV Access
To access the backside of the phone/cable TVoutlets, remove the three screws at the top ofthe amber lens (if not already completed) andthe two screws in the two top corners of thebreaker/phone/TV faceplate. Lift the recep-tacle plate up and forward to access the backof the phone/cable TV outlets. Connect the
phone and cable TV outlets, place the face-plate back into position, and secure it with thefive screws.
Maintenance
Eaton - Marina Power and Lighting producesunits that are designed to withstand the harshmarine environment. Maintenance is requiredto keep the units looking new for many yearsand to keep the warranty effective.
Exterior Maintenance
To remove of dirt, grime, and bird droppings,use a mild solution of dishwashing detergentat approximately one teaspoon per gallon ofwarm water. Once clean, follow up with awater based insect spray to kill the spidersaround the base and main housing of the unit.
DO NOT use a petroleum based insect spray.
DO NOT spray under breaker/receptacle door.
DO NOT use any solvent or corrosioninhibiting products on any part of the unit.This can cause serious stress cracking of theengineered resins and will void warranty.
DO NOT pressure wash unit or around unit.
Interior Maintenance
Before attempting the following maintenanceprocedures, turn off the power to the unit atthe power supply panel.
Note
The breakers on the unit DO NOT turn the unit power supply off and the buss bars willbe energized.
• Exposing the Buss Bar Assembly
Annually, remove the front cover at thebottom of the unit to expose the buss bars.
• Maintenance of Buss Bar Assembly
On all units, the buss bars should be visu-ally examined for excessive heating. Ifpotentially faulty or loose joints are found,they should be tightened or replaced.
In the cases where mechanical lugsinstead of the stud-lug buss assembly areused, it is very important that they beexamined closely. Most mechanical lugsare made of aluminum and are verysusceptible to galvanic corrosion.
If the set screw cannot be tightened,replace the lug. If there appears to becorrosion around the copper to aluminumconnection, remove the copper wire andclean the wire, coat the wire with an anti-corrosion grease, and retighten the assembly.
• Receptacles and Breakers
The receptacles and breakers should beexamined annually, and if any sign ofheating is evident, the receptacles orbreakers should be replaced.
• Solvents
DO NOT spray any solvents on the elec-trical components. Solvents will causestress cracking of the polymeric materialsand will void warranty.
Lighting Assembly
To test the lighting assembly, the photocellshould be covered with a piece of black tapeand in about 2-3 minutes the light should illu-minate. If this does not occur, the followingitems should be checked: photocell and bulb.
Winterizing
The water system should be purged with airand each ball valve should be opened andclosed after the system has been drained.This will remove the slug of water thatremains in the ball. Failure to remove waterfrom valve will result in cracking if exposed tofreezing temperatures.
Operation
Connect Power Cord to Boat
Insert the proper end of the shore power cordinto the boat’s power inlet connection, twistthe plug to lock, then tighten the locking plugretainer by twisting the large nut until the unitis tight to the boat.
Connect Power Cord to Pedestal
Harbor Mate: With the breakers off, insertthe shore power cord into the receptacle andtwist the plug clockwise until the plug locksinto the receptacle.
Camp Mate: With the breakers off, insert RVcord into the receptacle.
Turn Breaker ON
With both connections secured, turn on thebreaker. The power indicator on the boatshould indicate a successful attachment ofthe plug and the receptacle.
www.marinapower.com 1-800-723-8009 Installation Guide #70-8630 Rev. 2 NEWPORT HARBOR MATE 1
Wiring Diagram
Wire Colors
(Line 1) L1 Black
(Neutral) N White
(Line 2) L2 Red
(Line 3) L3 Blue
(Ground) G Green
Compression Terminals (Not Included)
Contractor needs to crimp termi-nals to line wires and place onprovided stud lug connector.
Remove Access Plate
Parts
Please visit www.marinapower.com for a fullparts listing.
To request a parts handbook:
• Call 1-800-723-8009 or
• E-mail [email protected]
Eaton Marina Power & Lighting Warranty Information
Our Quality Pledge
Eaton is dedicated to developing and manu-facturing the highest quality products whilekeeping true to our corporate ethics. Ourwarranty is one way that we strive to be themost admired company in our markets.
Product Warranties
To obtain warranty service, discuss extendedwarranties or for questions contact us atwww.marinapower.com or call us at 800-258-8800.
Eaton CorporationMarina Power and Lighting149 Warwick CourtWilliamsburg, VA 23185United Statestel: 1-800-723-8009fax: 757-258-8805www.marinapower.com
www.marinapower.com 1-800-723-8009 Installation Guide #70-8630 Rev. 2 NEWPORT HARBOR MATE 2
Base Diagram
www.marinapower.com 1-800-723-8009 Installation Guide #70-8630 Rev. 2 NEWPORT HARBOR MATE 3
Stand Dimensions
Dimensions
www.marinapower.com 1-800-723-8009 Installation Guide #70-8630 Rev. 2 NEWPORT HARBOR MATE 4
Water Assembly
Pedestal
www.marinapower.com 1-800-723-8009 Installation Guide #70-8630 Rev. 2 NEWPORT HARBOR MATE 5
Telephone and Cable TV Assembly
Newport Harbor Mate
Telephone and Cable TV Assembly
Newport Camp Mate
www.marinapower.com 1-800-723-8009 Installation Guide #70-8630 Rev. 2 NEWPORT HARBOR MATE 6
Buss Bar AssemblyNewport Harbor Mate
Newport Camp MateBuss Bar Assembly