new section: rotary heat exchanger with a heat pump effective and smart! · 2017. 12. 18. ·...

6
NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart! WWW.SALDA.LT 2016 Ver. A

Upload: others

Post on 07-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • The company reserves the right to make changes of technical data without prior notice

    NEW SECTION:ROTARY HEAT EXCHANGER W I T H A H E A T P U M PEffective and smart!

    WWW.SALDA.LT

    2016Ver. A

  • The company reserves the right to make changes of technical data without prior notice

    1 kW UP TO 11kW /40kW

    1 kW 0,9 kW

    SECTION OF THE ROTARY HEAT EXCHANGER WITH THE HEAT PUMP: ideal solution targeting multiple goals

    In conventional design of air-handling and heat-ing-cooling system several units are used: either chiller or condensing unit are combined with the main air handling unit or additional parts are inte-grated. Often both units are ordered from differ-ent suppliers, thus, this requires additional costs for installing and commissioning. Combination of rotary heat exchanger and heat pump offers new opportunities in design of modu-

    lar units. The unit can work in winter and in sum-mer. When the unit runs in summer mode the supplied air is cooled using rotary heat exchanger first and then, additionally, using heat pump. The reverse process is used when the unit works in winter mode – the supplied air is heated.The most important thing is that the unit is fac-tory adjusted and tested. This minimizes efforts required on site.

    COOLING CONTROLHEATING HEAT RECOVERY

    4 IN ONE:HEATING, COOLING, HEAT RECOVERY, AND CONTROL IN ONE UNIT!

    HEATING RECOVERY

    COOLINGRECOVERY

  • The company reserves the right to make changes of technical data without prior notice

    ¹ At the following conditions:

    Air data ParametersWinter Supply air

    Outdoor air temp. (oC)

    Outdoor air humidity (%)

    Extract air temp. (oC)

    Extract air humidity (%)

    Air flow (m3/h)

    Press. to system (Pa)

    Efficiency varies when desired conditions change. You can check exact characteristics for desired conditions using a freeware AHU selection tool VentMaster v5 http://www.salda.lt/ventmaster/v5/ventsetup5.exe

    Unit size 6KR.

    Summer Exhaust air-12

    90

    20

    40

    5000

    300

    28

    60

    22

    60

    5000

    300

    › High efficiency of the unit: e.g. it can cooling up to EERfull 11 and heating up to COPfull 401 .› The unit is factory tested and adjusted;› Environment friendly: the refrigerant R410A is used.› Custom solutions: each section is designed according to chosen parameters. Available ver-sions down to -20 °C without air preheating! Left and right versions! Customized air intake:

    top or bottom!

    MAIN ADVANTAGES:

    Supply air temperature

    Winter (oC)

    Summer (oC)

    22

    18

    http://www.salda.lt/ventmaster/v5/ventsetup5.exe

  • The company reserves the right to make changes of technical data without prior notice

    EFFICIENCY ROTOR VS. ROTOR WITH HEAT PUMPWhen specific models are discussed, the advantage of the rotor with the heat pump becomes obvious. We have compared 5000 m3/h unit working in Central European weather conditions, where the winter temperature is as low as -12°C, and as high as +28°C in summer.

    The section saves energy used for air cooling and heating. Without a heat pump, the additional energy for cooling and heating would be required and energy costs would be higher.

    WINTER (HEATING) VS

    -10°C

    +20°C

    -12°C

    +22°C -7°C

    -12°C

    +20°C

    +22°C

    SUMMER (COOLING) VS

    +36°C

    +28°C

    +22°C

    +18°C +27°C

    +28°C

    +22°C

    +18°C

  • The company reserves the right to make changes of technical data without prior notice

    Summer (evaporator)Winter (condenser)

    Rotary heat exchanger

    (efficiency up to 87 %)

    Electronic expansion valve

    Frequency converter

    Mechanical high and low pressure protection

    Summer (evaporator)Winter (condenser)

    TECHNICAL INFORMATION

    STRUCTURAL SCHEME OF WORKING UNIT

    The heat pump consists of the following main components: variable speed compressor, evaporator, conden-ser, electronic expansion valve. The operation of these components altogether is consistent, so the unit can be controlled smoothly. All system com-ponents are interconnected using copper pipeline

    inside the unit. The unit is suited for use of R410A type environment friendly refrigerant. Double protection is integrated into the heat pump. The control equipment of the heat pump is fully com-patible with the main controller of the air handling unit.

    Variable speedcompressor

    One of the best when it comes to strength, insulation characteristics and tightness casing certified by Eurovent) (D1(M) › L1(M) › L1(M) › F9(M) › T2 › TB1)).

    ETA

    SUPODA

    EHA

  • The company reserves the right to make changes of technical data without prior notice

    Easy modeling of the unit using Eurovent certified AHU selection tool VentMaster V5 Click here and get your free copy of the application!

    UAB SALDARagainės g. 100

    LT-78109 ŠiauliaiLithuania

    [email protected]

    Distributor

    +370 41 54 04 15+370 41 54 04 17

    Salda UAB offers long-term solutions:

    Do you need further information?Do you need further information? Please contact our regional distribu-tors and they will offer you the optimal solution!

    2 yearTW

    O Y E A R S · TWO YEARS · TWO YEARS ·

    TWO

    YEAR

    S ·

    warrantyTESTED

    › We offer 2 years warranty for the entire unit!

    › A l s o w e e n s u r e the 24 hour service response.

    › Post-warranty service and spare parts supply.

    › Tested in independent laboratory at real-time conditions.

    http://www.salda.lt/ventmaster/v5/ventsetup5.exe