new generation nid for pc market

29
Next Generation NID for PC Market Lawrence Gatton Principal Engineer Alstom Power ECS

Upload: shethparag1

Post on 30-Oct-2015

28 views

Category:

Documents


0 download

DESCRIPTION

FGD TECHNOLOGIES

TRANSCRIPT

Page 1: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 1/29

Next Generation NIDfor PC Market

Lawrence Gatton

Principal Engineer 

Alstom Power ECS

Page 2: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 2/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Agenda

Overview - FGD Technology

NID Technology Overview

NID History and Reference Units

PC NID Applications

Current US PC-NID Projects

Page 2

Page 3: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 3/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

FGD Technology Comparison

Alstom FGD Technologies - J an 2010 Page 3

Technology OST SDA NID

Design WFGD DFGD

Absorber Spray Tower Spray Dryer J -Reactor

Reagent Limestone Lime Lime

Reagent Preparation Wet Ball Mill Detention Slaker Integrated Hydrator

Byproduct Gypsum CaSO3/CaSO4/Ash CaSO3/CaSO4/Ash

Dewatering Hydroclone/Belt Filter N/A N/A

Performance

Stoichiometric Ratio 1.02-1.03 1.5-1.8 1.5-1.8

Approach Temperature 0 ºF 30 ºF 25 ºF

L/G 90-175 gal/kacf 0.03 gal/kacf 0.03 gal/kacf  

Pressure Drop 3-9 in. w.g. 11-13 in. w.g. 13-15 in. w.g.

SO2 Removal Eff. 99+% 95% 98%

SO2 Inlet (max) >10 lb/MMBtu 2-3 lb/MMBtu 5-6 lb/MMBtu

Page 4: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 4/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

FGD Technology Comparison

Alstom FGD Technologies - J an 2010 Page 4

300 ºF SDA NID

125 ºF

WFGD

25 ºF30 ºF

Page 5: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 5/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Agenda

Overview - FGD Technology

NID Technology Overview

NID History and Reference Units

PC NID Applications

Current US PC-NID Projects

Page 5

Page 6: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 6/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

NID – Mixer/Hydrator

Ca(OH)2

HF

HClSO2

SO3

HF SO3

HClSO2

1 - 2 Monolayers

D50: ~ 5 μ

NID Technology Overview

Page 7: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 7/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

NID – Water Spray System

NID Technology Overview

Page 8: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 8/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

DFGD Systems: Two Approaches

SDA NID

NID Technology Overview

Page 9: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 9/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Key ComponentsFabric filterReactorRecycle Feeder

MixerHydratorFluid trough

Reactor

Fabric Filter

Fluid Trough

LimeHydrator

Mixer

RecycleFeeder

NID Components

Page 10: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 10/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Agenda

Overview - FGD Technology

NID Technology Overview

NID History and Reference Units

PC NID Applications

Current US PC-NID Projects

Page 10

Page 11: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 11/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Modularized PC-NID

• Multiple modules

• Nominal 45 - 90 MW size ea

• Can be designed to achieve

emissions guarantees at full loadwith one module out of service

Page 11

Page 12: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 12/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

PC-NID Advantages

• Low Load Turndown- Achieved through Module isolation w/o gas recirculation- Ability to start SO2 removal with first introduction of coal

• Capacity- Single system capacities > 800 MW

• Multi-Pollutant Control- SO2 – up to 98% Removal w/ 5.0 lb SO2/MBtu Inlet- HCl, HF , SO3 – < 1 ppmemissions

- Filterable Particulate – < 0.010 lb/MBtu- Hg – High PAC utilization

Page 12

Page 13: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 13/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Modular NID Arrangement

Page 13

Page 14: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 14/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Modular NID Arrangement – Foot Print

Page 14

300 ft

140 ft

100 ft

600 MW Nominal SDA/FF

2 x 60 ft SDA Vessels

1 x 200 ft Fabric Filter

Page 15: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 15/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Modular NID Arrangement – Foot Print

Page 15

300 ft

140 ft

100 ft

165 ft

110 ft

600 MW Nominal NID/FF

8 x 4 m NID Modules

Includes 8 Compartment Fabric Filter

Page 16: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 16/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Page 16

Modular NID Arrangement – Foot Print

Page 17: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 17/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Agenda

Overview - FGD Technology

NID Technology Overview

NID History and Reference Units

PC NID Applications

Current US PC-NID Projects

Page 17

Page 18: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 18/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

NID Development Time Line

• University of Tennessee, MDI Pilot Plant – 1987

• TVA Shawnee, MDI Test Facility - 1993

• Vaxjo, Sweden, NID Pilot Plant – 1996

• Laziska, Poland, NID Commercial Operation - 1996

• Windsor, CT, Alstom-PPL CFB-NID Pilot - 2002

• Reliant, Seward, 1st US NID Commercial Operation – 2004

• Windsor, CT, Alstom-PPL PC-NID Pilot – 2009

• Millsboro, Delaware, 1st U.S. PC NID – Startup Fall 2011

• Somerset, Massachusetts, PC-NID – Erection during 2011/12

Page 18

Page 19: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 19/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

 TVA Shawnee – MDI Test Facility (1993)

Page 19

Page 20: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 20/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

NID Pilot Plant – Växjö, Sweden

Page 20

NID PilotPlant

Page 21: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 21/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

NID Pilot PlantPower Plants Labs, Windsor, CT (2009)

BSF – Boiler Simulation Facility - 15 MW(Thermal) Pilot

Page 21

Page 22: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 22/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

World-Wide NID Installations

Zhejiang 8 70 MWDong Guan 5&6 2x70 MWBinjiang TPP 13 MW

 J iangying TPP 70 MW J iulong Paper 135 MWBautou 2 200 MWHua Ying Shan 100 MWXinyuan TPP 25 MW

 J ingmenTPP 2x200 MWLiwen Paper 1&2 2x30 MWSanfangxiang 2x25 MWShengyang 2x50 MWWuxi TPP 25 MWXinwang 1&2 2x135 MWZibo 7&8 2x100 MWHeibi TPP 2x135 MW

 J uhong TPP 135 MW Taizhou6 135 MW Yima TPP 78 MWShenhai 200 MW

Laziska 1&2 2x120 MW

Vaasa 37 MWSandreuth 3 53 MW

Fifoots 1-3 3x125 MW

Mai Liao 2x150 MW

Elektranai8 150 MW

Seward 1&2 2x285 MWGilbert 3 300 MWSpurlock 4 300 MWIndian River 4 440 MWBrayton Point 3 630 MW

Mondi 1&2 2x35 MW Mindinao 1&2 2x105 MW

Kohlta J arve 50 MW

Secunda 120 MW

Zilina 260 MW

Alstom FGD Technologies - J an 2010 Page 22

Page 23: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 23/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Alstom NID – Product Presentation - May 2011

First Commercial NID System

Elektrownia Power - Laziska Power Plant, Units 1 & 2

Location: Laziska, Poland

Application: PC Boiler

Fuel : Coal – 1.4%

Inlet Loading: 1400 ppm

Gas Flow: 510,000 ACFM

Commercial: Unit 1,1996, Unit 2,1997

SO2: 95% Removal Measured

Opacity: Less than 20%

Unit size: 2 x 125 MWReagent: Lime

Byproduct: Landfill

Page 23

Page 24: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 24/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

First US NID Application

Reliant Energy – Seward StationLocation: Seward, PA

Application: CFB Boiler

Unit size: 2 x 260 MW

Scope: Material supply

Fuel : Waste Coal / 10.0 lb SO2/MBtu

Gas Flow: 880,000 acfm

Commercial: 2004

Emissions:

SO2: 95% removal (Total System)

Particulate: 0.015 lb/MMBtu

Page 25: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 25/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Agenda

Overview - FGD Technology

NID Technology Overview

NID History and Reference Units

PC NID Applications

Current US PC-NID Projects

Page 25

Page 26: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 26/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

NRG – Indian River Unit 4

Location: Millsboro, DE

Application: PC Boiler

Unit size: 440 MW

Scope: Material supply

Fuel : Bituminous coal

Inlet Loading: 4.5 lb SO2/MMBtu

Gas Flow: 2,300,000 acfm

Commercial: December 2011

Emissions:

SO2: 96% RemovalParticulate: 0.012 lb/MMBtu

Page 26

Page 27: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 27/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Dominion/Kiewit – Brayton Point Unit 3

Location: Somerset, MA

Application: PC Boiler

Unit size: 630 MW

Scope: Material supply

Fuel : Bituminous coal

Inlet Loading: 2.5 lb SO2/MMBtu

Gas Flow: 2,400,000 acfm

Commercial: February 2014

Emissions:

SO2: 98% removalParticulate: 0.010 lb/MMBtu

Page 27

Page 28: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 28/29

©ALSTOM 2011. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty isgiven or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Dominion/Kiewit – Brayton Point Unit 3

Page 28

Page 29: New Generation NID for PC Market

7/15/2019 New Generation NID for PC Market

http://slidepdf.com/reader/full/new-generation-nid-for-pc-market 29/29

www.alstom.com