nellcor n-85 hand-held capnograph/pulse oximeter with ...€¦ · 39 to 99 mm hg ±5% of reading...

2
MICROSTREAM ® * CAPNOGRAPHY TEAMS UP WITH NELLCOR PULSE OXIMETRY WITH OXIMAX TECHNOLOGY e Nellcor N-85 hand-held capnograph/pulse oximeter with OxiMax technology combines two highly advanced technologies in a convenient, portable device. Microstream®* capnography helps ensure accurate end-tidal CO 2 measurements and crisp waveforms, giving you a clear picture of your patient’s respiratory status. 1 e extensive selection of Microstream breath-sampling accessories allows you to monitor intubated and nonintubated patients—including those receiving supplemental oxygen. Nellcor Oximetry Advantage. e Nellcor N-85 monitor delivers exceptional pulse oximetry performance even during low perfusion and signal interference. 2 Nellcor™ specialty sensors—including the forehead SpO 2 sensor and nonadhesive SpO 2 sensors—expand your patient care options. Nellcor N-85 Hand-Held Capnograph/Pulse Oximeter with OxiMax Technology FOR PATIENT CARE ANYWHERE The Nellcor N-85 hand-held monitor is convenient for spot checks and continuous monitoring in a variety of settings, including EMS/ED, transport, critical care, operating room, sleep lab and for procedural sedation.

Upload: others

Post on 03-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: nellcor n-85 hand-held capnograph/pulse oximeter with ...€¦ · 39 to 99 mm Hg ±5% of reading Respiration Rate: 0 to 150 breaths/minute pulse oximeter Display ... operating temperature

MicrostreaM®* capnography teaMs up with neLLcor™

puLse oxiMetry with oxiMax technoLogy

The Nellcor N-85 hand-held capnograph/pulse oximeter with OxiMax technology combines two highly advanced technologies in a convenient, portable device. Microstream®* capnography helps ensure accurate end-tidal CO2 measurements and crisp waveforms, giving you a clear picture of your patient’s respiratory status.1 The extensive selection of Microstream breath-sampling accessories allows you to monitor intubated and nonintubated patients—including those receiving supplemental oxygen.

• NellcorOximetryAdvantage. The Nellcor N-85 monitor deliversexceptional pulse oximetry performance even during low perfusionand signal interference.2 Nellcor™ specialty sensors—including theforehead SpO2 sensor and nonadhesive SpO2 sensors—expand yourpatient care options.

nellcor™ n-85 hand-held capnograph/pulse oximeter

with oxiMax™ technology

For patient care anywhere

The Nellcor N-85 hand-held monitor

is convenient for spot checks and

continuous monitoring in a variety of

settings, including EMS/ED, transport,

critical care, operating room, sleep lab

and for procedural sedation.

Page 2: nellcor n-85 hand-held capnograph/pulse oximeter with ...€¦ · 39 to 99 mm Hg ±5% of reading Respiration Rate: 0 to 150 breaths/minute pulse oximeter Display ... operating temperature

11 72PR R

40 MMHg

References1. Maddox RR, Williams CK, Oglesby H, Butler B, Colclasure B. Clinical experience with patient-controlled analgesia using continuous respiratory monitoring and a smart infusion

system. Am J Health Syst Pharm. 2006;63(2):157-164. 2. FDA 510(k)

COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U.S. and internationally registered trademarks of Covidien AG. Other brands are trademarks of a Covidien company. ™* and ®* are trademarks of their respective owners. ©2011 Covidien. All rights reserved. 11-PM-0309 MN04305

www.covidien.com

MicrostreaM®* capnography

The Nellcor N-85 hand-held monitor with OxiMax technology provides full-featured capnography with crisp waveform display and trend data.

• Formechanicallyventilatedandnonintubated patients.

• Lowsampleflowrateof50mL/minallows monitoring on the widest range ofpatients, from neonates to adults.2

• ReliableCO2 monitoring, even in highhumidity environments.2

• Innovativeopticalbenchenhancesstable,accurate measurements from a smallsample.2

• WideselectionofCO2 samplingaccessories available.

nellcor™ pulse oximetry

Equipped with Nellcor pulse oximetryadvanced digital signal processingtechnology, the Nellcor N-85 hand-heldmonitor with OxiMax technology standsup to difficult monitoring conditions,offering reliable SpO2 and pulse ratemeasurements.

• Accuratemonitoringevenwithweakpulse signals.2

• Ahand-heldmonitoringalternativeforuse with the family of Nellcor sensors.

• Providesgraphicaltrendsandplethysmographic waveform.

• InterfaceswiththeNellcor™OxiNetIIIremote monitoring system.

Features and speciFications

perForMancecapnographDisplay Range: 0 to 99 mm Hg (0-13.2 kPa and 0-13.0

vol% at sea level)

Sampling Rate: 50 ± 7.5 mL/min

Warm-Up Time: 30 seconds typical, reaches steady-state accuracy 20 minutes after power up

Accuracy: 0 to 38 mm Hg ±2 mm Hg 39 to 99 mm Hg ±5% of reading

Respiration Rate: 0 to 150 breaths/minute

pulse oximeterDisplay Range: SpO2: 0% to 100%

Pulse Rate: 20 to 250 beats/minute

Accuracy:

Saturation (% SpO2 ± 1 SD):

Adults: 70% to 100% ± 2 digits

Neonates: 70% to 100% ± 3 digits

Low perfusion: 70% to 100% ± 2 digits

Pulse Rate: 20 to 250 bpm ± 3 digits

Low perfusion: 20 to 250 bpm ± 3 digits

communication interfaceRS-232 interface @ 9600 baud; full duplex serial interface via RJ-45 connector

eLectricaLinstrument Power requirements: AC input of 100 to

230 VAC @ 60/50 Hz

Battery Type: Rechargeable NiMH

Battery Capacity: Supplies power for 4 to 7 hours (de-pending on power management) Fully recharges in approximately 4.5 hours

environMentaLoperating temperature 32°F to 113°F (0°C to 45°C)

storage temperature -31°F to 158°F (-35°C to 70°C)

operating and storagePressure: 430 mm Hg to 795 mm Hg

Altitude: -1,250 ft to 15,000 ft (-381 m to 4,572 m)

Humidity: 10% to 95% noncondensing

Shock test IEC 68-2-27

Sinusoidal vibration test IEC 68-2-6

Random vibration wide band test IEC 68-2-34

Drop test MIL-STD-810E, method 516.4-II

the hand-heLd choice

Nellcor™ N-85 monitor with OxiMax™technology:EtCO2 and SpO2(capnography/pulseoximetry)EtCO2 (capnography only)•ACandbatteryoperation•User-adjustablealarms•Dataoutput/printing•Four-languagemenu

standards

IEC 60601-1/EN 60601-1, EN60601-1-2 second edition, EN 864, EN 865, UL 2601-1, EN 475, EN 55011-Class, B-Group 1, CSA C22.2 No.601.1-M90

physicaL characteristicsweight N-85: 1.87 lb (850 g) NPB-

70: 1.66 lb (750 g)

size 8.11 in H x 3.46 in W x 2.06 in D (206 mm x 88 mm x 53 mm)

Displayed Parameters

N-85: CO2 and plethysmographic waveforms, EtCO2, SpO2, pulse rate, respiration rate, trend data.

displayGraphic LCD display (128 x 64 dots) with LED backlight (contrast and backlight control); two numeric fields, three

digits each, using 7-segment LED; two-color LED alarm bar

alarmsAdjustable alarm limits for all parameters; audio level as defined in ISO 9703-2 standard

co2 accessoriesNonintubated Applications:

Smart CapnoLine®* and Smart CapnoLine®* O2 oral/nasal circuits

CapnoLine®* H† and CapnoLine®* H† O2 nasal circuits

NIV Line nasal circuit

Intubated Applications:

FilterLine®* Set and FilterLine®* H† Set, combination

EtCO2 circuit and airway adapter†H indicates for humidified applications; up to 72-hour duration

other accessoriesCarrying case

Protective boot

Polemount clamp

Digital to analog converter

Communication adapter kits

Calibration gas kit

External battery charger

Extra rechargeable battery pack

Battery pack carrying pouch

Nurse call and remote monitoring interface kits