negative air pressure purifier ardc-2502 · 2020. 11. 16. · specification and dimension model...

12
Negative Air Pressure Purifier ARDC-2502 We strive to provide innovative products and services for a prosperous and healthy life of our customers. USER`S MANUAL

Upload: others

Post on 27-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Negative Air Pressure Purifier ARDC-2502

We strive to provide innovative products and services for a prosperous and healthy life of our customers.

USER`SMANUAL

Page 2: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Specification and Dimension

Model ARDC-2502

MainUnit

Specification

Filter

Supply voltage AC110V~230V, 50/60Hz, 750W

Air Volume(Fan) Max. 70CMM(m3/min) ≒ 2,472CFM

Size & Weight 672*579*1314(mm), 129kg

Operation Mode 0~100 / Digital air volume control

Medium 29CMM, 15mmH2O (≥85%)

* Maintain negative pressure up to 53m² based on -2.5Pa and 12ACH.

* Air purifier mode can be used up to 204.4m².

Frame material Powder coating steel plate

Air Volume(with Filter) Max. 26.5 CMM(m3/min) ≒ 936 CFM

UV LED UV-C (10mW x 48ea) / UV-A (450mW x 6ea)

Pre, Carbon 56CMM, 15mmH2O

HEPA 26CMM 29.7mmH2O(≥99,99%, 0,3㎛)

TOP VIEW

LEFT VIEW FRONT VIEW RIGHT VIEW REAR VIEW

Integrated Sensor Module

672

579

1314 UV LED

Page 3: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Move the main body to the installation point, connect the power cable to the upperpower supply on the right, and open the front door to switch the circuit breaker tothe ON lever. Use it according to the operation method afterward.

※ How to Switch To Negative Pressure Function

① Move the body to the installation point and remove the upper cover and the carbon filter.

③ Once the duct connection is complete, press the ON lever of the wheel to secure it.

② Complete the exhaust point with the appropriate material and hood cap, then connect the 250mm diameter duct hose.※ We recommend a flexible triple induction pipe for noise reduction.

Installation

Page 4: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Operation

Press theMain power button.

PowerOn

Upper modulein manual mode.

FanOn

Press thesystem power button.

Appropriate outputadjustment

Press theoperating button.

Controllerunlock

Press it for 5seconds

Lock Mark

① Main Power → Upper Module in Manual Mode → System Power → Operate the equipment in the order of the operation buttons.

② When the equipment starts running, the output is marked at [100] and the fan starts running after 10 seconds.

③ After the fan operates, adjust the output to the proper level using the control button inthe leftcorner.※ Refer to the operation data of this manual for proper adjustment according to the volume of the isolation room.

④ To prevent unauthorized controller malfunctions, the output button switches to auto-lock mode after 30 seconds of operation and a dot next to the output number is displayed.

⑤ To unlock the controller while the equipment is running in lock mode, press the output reaction button for 5 seconds to turn off the lock mark and adjust the output.

1. Negative Pressure (Manual) Mode

Page 5: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Clean(0-15)

Normal(15-50)

Caution(50-100)

Serious(More than 100)

2. Air Purifier – Automatic Mode① In Manual Mode AUTO press this button to switch to AutoMode

② It indicates the concentration of fine dust (based on PM2.5)

③ Depending on the concentration of fine dust, the color changes to four different levels and automatically adjusts the output of the fan.

④ CO2 concentration display. (Unit:10ppm)

⑤ If the CO2 concentration is greater than 1,200 ppm , the ventilation warning lamp flashes . If it falls below 1,000 ppm, the warning lamp goes out

⑥ Displays the current temperature.

⑦ Displays the level of humidity.

3. Air Purifier – Maximum Output Mode

4. Air Purifier – Sleep Mode

5. UV LED

① MAX Press the button to switch to full power mode and select if quick air cleaning is required.

① SLEEP Press the button to switch to sleep mode, minimizing the fan output and turning off the lights of the upper moudule.

① UV LEDs operate in the air intake at the bottom of the filter for air and filter sterilization.

② UV LED is semi-permanent and safe, it does not produce ozone .

③ The light that is seen through the lower suction area is safe, the pre-filter blocks out the light, so it is not harmful to people.

③④

⑥ ⑤

Page 6: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Filter Replacement

① The replacement cycle for each filter is as follows. A. Pre - filter: It is recommended to replace it every three months when operating for 10 hours a day and/or when the level of contamination is severe when visually checked. B. Medium and HEPA filter: 3,200 hours of use, for about one year when operating 10 hours a day (when the filter light flashes). C. Carbon filter: It is recommended to replace the filter every six months if it operates for 10 hours a day.

② Pre-filter replacement A. Open the front door of the main body; rotate the levers on the left and right side of the pre-filter to release the filter, and remove it. B. Replace it with a new filter and tighten the lever again in the opposite direction.

③ Replacement of Medium and HEPA filters (Patent application No.2020-0034174) A. Open the front door and pull forward the levers on the left and right side of the filter to remove it when the filter is lowered. B. After replacing with a new filter, push the lever in the opposite direction to secure it. C. To combine filters, place the medium filter on the bottom and the HEPA filter on the top. D. When combining filters, the arrow shown in the filter is combined upwards.

Page 7: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

④ Carbon filter replacement method A. Open the upper module lid, loosen the filter cover bolts, remove the cover, and replace the filter. B. After replacing the filter, assemble it in reverse order.

⑤ How to reset the filter usage time after replacing HEPA and Medium filters A. After replacing the filter, press the main power button and the number on the output screen will flash for about 3 seconds. B. The number displayed at this time indicates the remaining usage time of the filter as a percentage. C. After the number on the display screen disappears, press the increase output button for 5 seconds to complete the reset of the hours of use (it will make a “beep” sound) D. Turn off all power buttons and restart.

Page 8: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Operation Data

Classification Motor OutputAir Volume (New filter) 12ACH

Availableroom size

(2.5m height)

Noise(1m away from

a machine)Air emission per 1minute (m3/ min)

Air emission per 1hour (m3/ h)

Power RPM CMM CMH m2 dB

100 2,300 26.5 1,590 53 65

95 2,185 25.2 1,511 50.4

90 2,070 23.9 1,431 47.7 62

85 1,955 21.4 1,284 42.8

80 1,840 21.2 1,272 42.4 58

75 1,725 19.9 1,193 39.8

70 1,610 18.6 1,113 37.1 56

65 1,495 17.2 1,034 34.5

60 1,380 15.9 954 31.8 52

55 1,265 14.6 875 29.2

50 1,150 13.3 795 26.5 48

45 1,035 11.9 716 23.9

40 920 10.6 636 21.2 45

35 805 9.3 557 18.6

30 690 8.0 477 15.9 42

25 575 6.6 398 13.3

20 460 5.3 318 10.6 40

15 345 4.0 239 8.0

10 230 2.7 159 5.3

※ The available room size and noise may differ depending on the installation method and the surrounding conditions.※ Recommended Power range during Air Purifier Mode. ※ The maximum (standard) area of the air purifier is based on the 204.4 m² Korea Industry Standards.

Recommended

Power

range

During

Negative

Pressure

Mode.

ASKO
Rectangle
ASKO
Rectangle
Page 9: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

Cautions and Quality Assurance

▷ Precautions

▷ The warranty period for product defects is one year. However, failures due to user negligence are excluded. - A/S Inquiries: +82 2 1855 1191

Familiarize yourself with the user manual and operate it.Do not apply excessive force and shock to the operating system.Replace the filter periodically and use our standard filter when replacing it.The use of non-exchange and non-standard filters can result in output degradation or failure.Do not use multiple power plugs simultaneously on a single outlet; always use more thanvoltage and current.Do not touch the power plug or main power switch with wet hands.Do not extend or modify the power line.Be sure to use product’s dedicated cable for rated voltage, frequency, and current conditions.Be sure to turn off the main power supply during installation, filter replacement, internal cleaning,and repair.Unplug the power or lower the main power switch during thunder or lightning, or when it is not used for a long time.Do not allow children or pets to be placed on top of the product.If the product makes a strange sound, smell, or smoke, remove the power plug or pressthe emergency stop switch ( ) on the side of the product.If water enters or is flooded into the product, stop using it and cut the power off and contactthe service center.Do not spray water on the product.Do not arbitrarily disassemble, repair or modify the product.Do not open the product inlet or outlet during operation.Do not use for prolonged periods in areas where voltage is unstable. It may cause malfunction.It can stop automatically to protect the product. At this point, completely remove thepower plug and restart it for more than 5 minutes, it will operate normally.Do not put other substances in the sensor hole or spray water, it may cause failure or fire.The surface of the filter is sharp. Be careful when replacing the filters.UV light is harmful to the body if you are directly exposed for a long time. The UV LED willautomatically turn off when the main door is opened, but UV light may leak out when the dooris closed and the equipment is operated without the pre-filter installed. Please be careful.However, the light transmitted through the pre-filter is not harmful.When using a negative pressure machine in an infected patient’s quarantine chamber, the filtermay be contaminated with viruses. It is recommended to replace the filter after sterilizing thefilter by operating the negative pressure machine for more than an hour after leaving the infected patient.

1.2.3.

4.

5.6.7.8.

9.

10.11.

12.

13.14.15.16.

17. 18.19.

20.

Page 10: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

MEMO

Page 11: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

MEMO

Page 12: Negative Air Pressure Purifier ARDC-2502 · 2020. 11. 16. · Specification and Dimension Model ARDC-2502 Main Unit Specification Filter Supply voltageAC110V~230V, 50/60Hz, 750W Air

specializes in manufacturing and distributingequipment and consumable supplies for infection control for

medical facilities, biological laboratories, and others.

ASKO CO., Ltd.

Office

Factory

Tel

www.asmedi.net | [email protected]

4F, PyeonghwaBldg. 59, Seongsuil-ro8-gil, Seongdong-gu, Seoul, Republic of Korea

3F, Chogwangsandandong-ro 6beon-gil71, Hanam-si, Gyeonggi-do, Republic of Korea