2/7/2017 NCC Building 1
NCC for your Data Center in Finland
Safety, cyber security and protected Data privacy • Finland is #1 safest country in the world (World Economic Forum 2015)
• No earthquakes, floods, tsunamis, tornadoes or political instabilities
• Guaranteed right of privacy of all information and stable and transparent legislation
• Governmental support – tax reductions and free business support services for foreign
investors
Cyber secure and safe environment and governmental support
Why Finland? You name it, we have it
Energy prices and Sustainable solutions • One of Europe’s lowest energy pricing and 99,99982% reliable power grid
• Free natural cooling – annual mean temperature in Helsinki region 5,9 °C
• Renewable energy sources and possibility to sell excess heat
Low operational costs and Total cost of ownership (TCO)
International connection HUB and developed ICT sector • Direct optical fiber sea cable from Helsinki to Rostock 144 Tbit/s total capacity
• Finland is #1 country in ICT readiness sector (World Economic Forum 2015)
• International cyber security cluster and availability of skilled work-force
Fastest data transmission and International ICT community
Largest foreign Data Centers in Finland
NCC Building 2/7/2017 2
Medium right picture Click on the picture
icon to change photo
2/7/2017 NCC Building 3
We are ready to go! Project team and partners
Title 2 column Blue top
2/7/2017 NCC Building 4
NCC Data Center concept
• Module architecture scalable
according to Client’s needs
• 2 to 30 MW of critical power
(110kV grid)
• PUE level <1,15
• 10 month construction time
• Excess heat recovery system
• Ready Tier 3 engineering
solutions
• VDC
• LEED / BREEAM certification
Title and content
Blue top
2/7/2017 NCC Building 5
NCC Data Center concept
Electricity Immediate capacity 2-30 MW (110 kV Fingrid line)
Construction of electrical connections on municipal land without
redemption
Additional energy source – natural gas, wind power, solar panels
Cooling system
IT Cooling System based on direct free air cooling system with
redundancy of N+1
Support rooms cooling based on close control units and
centralized chiller with redundancy of N+1
Excess heat recovery system Based on water heat pumps and heat recovery coils
Possibility to sell excess heat to district heating system (Fortum)
Title on picture
with textbox Click on the picture
icon to change photo
Data Center by NCC in Järvenpää
Data Center land plot 1
Data Center land plot 2
Data Center Land plot 1 – 2,8 ha
Data Center Land plot 2 - 12,5 ha
Expansion possibilities
Building right > 50%
Electricity, fiber connections, district heating, natural gas
Municipalities on board
Approved city plan (Asemakaava)
We are looking for
• Owner
• (Co-) investor
• Customer
• Operator
• Partner
and / or
Title 2 column Blue top
2/7/2017 NCC Building 7
NCC Data Center concept
IDEAS OR SUGGESTIONS? Contact US!
www.ncc.fi/datacenter
www.ncc.group/datacenter
Jari ”Harppi” Harapainen [email protected] +358 50 323 7582
Elizaveta ”Liza” Ageeva [email protected] +358 43 826 7610
Jenni Ijäs [email protected] +358 50 406 2822
Mika Ukonmaanaho [email protected] +358 50 377 2935
Logotype
8 2/7/2017 NCC Building