narroline double-hung windows contents double-hung …...20-2 narroline® double-hung windows a r c...
TRANSCRIPT
20-1
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5
Contents
Narroline® Double-Hung Windows
Basic Unit Details - Narroline® Double-Hung Windows ......... 20-2
Basic Unit Details - Narroline Transom Windows .................. 20-3
Options / Accessories
Andersen® Grilles .............................................................. 20-4
Stools and Extension Jambs for Narroline Basic Units ....... 20-5
Stools and Extension Jambs for Narroline Transom Units ... 20-6
Sill Stop and Stool ............................................................ 20-7
Combination Unit .............................................................. 20-8
Joining Details .................................................................... 20-9
Anchoring Methods ........................................................... 20-11
Suggested Product Applications ........................................ 20-12
Circle Top™ for Narroline® Double-Hung Windows
Basic Unit Details
Circle Top™ Basic Unit .................................................... 20-14
Options / Accessories
Andersen® Grilles ............................................................ 20-15
Extension Jambs ............................................................. 20-16
Trim Options and Applications
Plinth Blocks ................................................................... 20-17
Interior Casing ................................................................ 20-18
Joining Details .................................................................. 20-19
Anchoring Methods ........................................................... 20-20
Suggested Product Applications ........................................ 20-21
• Slim frame and sash profile maximize the field of view.
• Excellent for creating large window combinations.
• Low maintenance.
20-2
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 5
Vertical Section
Basic Unit Details - Narroline® Double-Hung Window
Horizontal Section
Basic UnitScale 3" = 1'-0" (1:4)
7/8" (22)
1-23/32"(44)
7/8"(22)
1-23/32"(44)
Unit Dimension Width
Clear Opening Width1-7/16"
(37)1-7/16"
(37)
1/8"(3)
Rough Opening Width
1/4" (6) 1/4" (6)
Lower sash
Jamb Jamb
Upper sash
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
15/32" (12)
1-5/16" (33)
4-1/2" (114)
1-5/8" (41)
1-7/16" (37)
1-13/16" (46)
2-1/4" (57)
1/2" (13) 11/16" (17)
1/2" (13)
1-3/16" (30)
3/8"(10)
2-3/8" (61)
1-7/8" (48)
3/8"(10)
3/8"(10)
Head
Check Rail
Sill
Optional Andersen®
stool
Optional Andersen®
insectscreen
20-3
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5
Vertical SectionTransom Unit
Basic Unit Details - Narroline® Transom (TR) Window
Horizontal SectionTransom Units
Transom UnitScale 3" = 1'-0" (1:4)
1-5/16"(33)
4-1/2"(114)
Rough Opening Width
Unit Dimension Width
Glass Width
1/4" (6) 1/4" (6)
2-5/8"(67)
2-5/8"(67)
7/8" (22)
1/8" (3) Jamb Jamb
1/2"(13)
1-11/16" (43)
1-5/16"(33)
4-1/2"(114)
2-1/4" (57)
1-5/8" (41)
1-3/16" (30)
3/8"(10)
15/32"(12)
13/16"(21)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Glas
s He
ight
3/8"(10)
3/8"(10)
Head
Sill
Optional Andersen®
wood filler
1/2"(13)
1-5/16"(33)
4-1/2"(114)
2-1/4" (57)
1-5/8" (41)
1-3/16" (30)
3/8"(10)
15/32"(12)
13/16"(21)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Glas
s He
ight
1" (25)
3/8"(10)
3/8"(10)
Head
Sill
Reduced bottom rail
Optional Andersen®
wood filler
Vertical SectionTransom TR10 Size Unit
20-4
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 5
3/8"
3/4"
1/2"
1"
7/16" 7/16" 7/16"
7/8"3/4" 1-1/8"
200 Series Grille Options
Removable Interior Andersen® Finelight™ Grilles-Between-the-Glass
Removable Interior Wood Grille Profiles (chamfer profile).
Grille Profiles Scale = Full
Andersen® Finelight™ Grilles-Between-the-Glass
Standard Grille Options / AccessoriesContact an Andersen Representative for project specific grille options.
Window Profile Patio Door Profile
20-5
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5
Options / Accessories
Stools and Extension Jambs for Narroline® Basic UnitScale 3" = 1'-0" (1:4)
Horizontal Section
3-27/32" (98)
7-1/8" (181)Wall
6-9/16" (167)Wall
5-1/4" (133)Wall
23/32"(18)
2-1/32" (52)
2-19/32" (66)
Extension Jambs(Modified tilt-wash extension jambs with tongue removed.)
Narroline® Stool[For wall thicknesses up to 5-1/4" (133).]
11/16" (17)
11/16" (17)
11/16" (17)
Modified tilt-wash stool with tongue removed.[For wall thicknesses up to 7-1/8" (181).]
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
5-1/4" (133)
4-9/16" (116)
3-1/
4" (8
3)
3/4" (19)
1-7/8" (48)Optional Andersen®Narroline® window stool
2-3/8" (60)
1-7/8" (48)
11/16" (17)
7-1/8" (181)
6-9/16" (167)
Sill
Jamb
Head
Optional Andersen® sill stop & stool
Horizontal Section
20-6
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 5
3-27/32" (98)
7-1/8" (181)Wall
6-9/16" (167)Wall
5-1/4" (133)Wall
23/32" (18)
2-1/32" (52)
2-19/32" (66)
Extension Jambs(Modified tilt-wash extension jambs with tongue removed.)
Narroline® Stool[For wall thicknesses up to 5-1/4" (133).]
11/16" (17)
11/16" (17)
11/16" (17)
Modified tilt-wash stool with tongue removed.[For wall thicknesses up to 7-1/8" (181).]
7-1/8" (181)
6-9/16" (167)
5-1/4" (133)
4-9/16" (116)
5-1/4" (133)
4-9/16" (116)
3-1/
4" (8
3)3/4" (19)
1-7/8" (48)Optional Andersen®Narroline® window stool
2-3/8" (60)
1-7/8" (48)
11/16" (17)
7-1/8" (181)
6-9/16" (167)
Sill
Jamb
Head
Optional Andersen® sill stop & stool
Options / Accessories
Stools and Extension Jambs for Narroline® Transom and Sidelight UnitsScale 3" = 1'-0" (1:4)
Horizontal Section
Horizontal Section
20-7
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5
Options / Accessories
Sill Stop and Stool
Vertical SectionSill Stop
Optional Andersen® high inside sill stop and sash lift upgrade.
3/4" (19)
Optional Andersen® stool set in sealant.
Optional Andersen®
sill stop
Optional Andersen® high inside sill stop and sash lift upgrade.
3/4" (19)
1/2"(6)
OptionalAndersen®
sill stop
Vertical SectionSill Stop DP Upgrade
Vertical SectionSill Stop DP Upgrade with Andersen Stool
Scale 3" = 1'-0" (1:4)
3/16"(5)
11/16"(17)
1-27/32"(47)
Optional Andersen® pine stool
Vertical SectionPine Stool
Note: Without 1/2” sill stop or stool, Narroline unit has no design pressure rating.
20-8
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 5
At Head - Outer frame of combination unit fits into head jamb window unit. Hinges fastened to the exterior of the head jamb enables easy cleaning of the sill.
At Check Rail - Strong aluminum check rail with stationary storm panel, insect screen and lower operating panel.
At Jamb - Storm panel operates on smooth vinyl channels within the side stile frame members. Insect screen is located outside the storm panel.
At Sill - Combination unit frame bottom rail with insect screen in place and operating lower panel in closed position.
Complete unit furnished by Andersen, not applied to window unit.
Combination Unit
Unit
Dim
ensi
on H
eigh
t
1-5/16" (33) 4-1/2" (114)
Roug
h Op
enin
g He
ight
Head
Check Rail
Sill
Hinge member
Combination unit for triple glazing
Stationaryupper storm panel
Insectscreen
Operatinglower panel
OptionalAndersen®stool
Vertical Section
Jamb
Combination unit
Scale 3" = 1'-0" (1:4)
Horizontal Section
Options / Accessories
20-9
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5
Narroline® Double-Hung to Narroline Double-Hung Scale 3" = 1'-0" (1:4)
Non-Reinforced Mullion
Joining Details
Steel Reinforced Mullion
2" Support Mullion
Unit Dim. Unit Dim.
1/16" (2)
Jamb Jamb
OptionalAndersen®
1-1/2" casing(2" modified)
OptionalAndersen®
spacer block
OptionalAndersen® steelreinforced join
OptionalAndersen® exteriorvinyl trim stripset in continuousbead of sealanteach side
2" (51) Unit Dim. Unit Dim.
Jamb Jamb
Structuralsupportby others
Interior trimby others
OptionalAndersen®
2" supportmullionwood filler
OptionalAndersen®
2" supportmulliontrim strip set in continuousbead of sealant eachside
Unit Dim. Unit Dim.
1/16" (2)
Jamb Jamb
OptionalAndersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
OptionalAndersen®
mullionspacer
OptionalAndersen®
interiortrim strip
Non-Reinforced Mullion
Joining Details
Steel Reinforced Mullion
2" Support Mullion
Narroline® Transom to Narroline TransomScale 3" = 1'-0" (1:4)
Unit Dim. Unit Dim.
1/16" (2)
JambJamb
OptionalAndersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
OptionalAndersen®
narrowmullionspacer
OptionalAndersen®
interiortrim strip
Optional Andersen®
1-1/2" casing(2" modified)
Optional Andersen®
spacer block
Optional Andersen®
steel reinforced join
Unit Dim. Unit Dim.
1/16" (2)
JambJamb
Optional Andersen®
exterior vinyl trim stripset in continuous bead of sealant each side
2" (51) Unit Dim. Unit Dim.
Jamb Jamb
Structuralsupportby others
Interior trimby others
OptionalAndersen®
2" supportmullionwood filler
OptionalAndersen®
2" supportmulliontrim strip set in continuousbead of sealant eachside
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
20-10
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 5
Joining Details
Narroline® Transom (TR) over Narroline Double-Hung WindowScale 3" = 1'-0" (1:4)
Vertical Section
Unit
Dim
ensi
on H
eigh
t
15/32" (12)
13/16"(21)
1/8"(3)
3/8" (10)
Unit
Dim
ensi
on H
eigh
t
Narro
line®
Uni
t Dim
ensi
on +
Nar
rolin
e® Tr
anso
m U
nit -
3/8"
= O
vera
ll Un
it Di
men
sion
1/2" (13)
1/2"(13)
1-13/16" (46)
2-1/4" (57)
1-3/16" (30)
1-11/16" (43)
2-1/4" (57)
1-5/8" (41)
1-3/16" (30)
1-5/8" (41)
1/8" (3)
3/8"(10)
3/8" (10)
1-5/16" (33)
4-1/2" (114)
Roug
h Op
enin
g He
ight
3/8"(10)
3/8" (10)
Transom
Sill
Head
20-11
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5
Standard application of installation flanges as shipped from Andersen to be used for 4-1/2" (114mm) wall construction. Narroline® double-hung window is secured in the opening by using threaded fasteners through the installation flange.
Anchoring Methods
Installation FlangeScale 3" = 1'-0" (1:4)
Installation Flange (Reversed Position)Scale 3" = 1'-0" (1:4)
Jamb ClipScale 3" = 1'-0" (1:4)
Score markings for bending
3/16"(5)
1-1/2"(38)
3"(76)
Regular installation flange in reverse position to accommodate a 4-1/8" (105mm) wall.
APPLICATION:
• First secure jamb clip to back side of window unit jamb(s)
• Apply 1' from corners of head jamb, sill and side jambs
• Space jamb clips evenly (maximum distance apart 32" on center)
• Jamb clip lateral design load capacity: maximum 200 lb.
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Narroline® double-hung window is secured in the opening by removing the sash stop and drilling through the side jamb into the masonry.
4-1/8"(105)
1/2"(13)
1/2"(13)
4-1/2"(114)
3-1/2"(89)
Threaded fastener(furnished byothers)
Jamb clip
Double-hung window unit secured in opening by others using Andersen® 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clips to secure unit fit in opening. Installation flange can be cut or removed as required to accommodate the jamb clips.
Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
20-12
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L E R E V . 0 3 / 0 5
Wall Types
Suggested Product Applications
Scale 1-1/2" = 1'-0" (1:8)
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Sill
Jamb
Head
Installationflangeall around
Installationflange all around
Head
Jamb
Sill
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
*1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is used with wood framing.
1/2" (13)*minimum
Removeinstallationflangeat head
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Installationflange allaround
Head
Jamb
Sill
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
20-13
N a r r o l i n e ® D o u b l e - H u n g W i n d o w s
A R C H I T E C T U R A L D E T A I L F I L ER E V . 0 3 / 0 5
Suggested Product Applications
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4" (6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Jamb
Head
Sill
Optional Andersen®
auxiliarycasing
Installationflangeall around
Head
Jamb
Optional Andersen®
auxiliarycasing
Sill
Unit
Dim
ensi
on H
eigh
t
Installationflange at headand jambs
Roug
h Op
enin
g He
ight
Removeinstallationflangeat sill
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Rgh.
Opg
.W
idth
1/4"(6)
Unit
Dim
.W
idth
Optional Andersen®
vinyl trim board
Existingframe wall
Installationflangeall around
Head
Jamb
Sill
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1/4"(6)
Unit
Dim
.W
idth
Rgh.
Opg
.W
idth
Existing masonry wall
Installationflange all around
Jamb
Head
Sill
Optional Andersen®
vinyl trimboard.Trim to fitas required.Finish trimmededge with Optional Andersenrigid vinylchannel
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E20-14 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Basic Unit Details
Vertical SectionScale 3" = 1'-0" (1:4)
Circle Top™ Basic Unit(for double-hung sizes)
4-1/2" (116)1-5/16" (33)
2-3/8" (60)
2-5/8" (67)
13/16" (21)
7/16" (11)
1-3/8" (35)
1-1/16" (27)
7/16" (11)
5/16" (8)9/16" (14)
Head
Sill
Extension jambs available for 4-9/16" (116), 5-1/4" (133), 6-9/16" (167) or 7-1/8"(181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 6-9/16" extension jamb is predrilled for easy application.
Extension Jambs for Circle Top™ (double-hung size) WindowsScale 3" = 1'-0" (1:4)
Horizontal Section
7-1/8"Wall
6-9/16"Wall
5-1/4"Wall
Unit Dim. Width
Optional Andersen®arched casing
Rough Opening Width
4-9/
16"
(116
)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)2-
9/16
" (6
5)
Face
: 2"
(51)
Face
: 11/
16"
(17)
1/4" (6)
3/4" (19) at curve11/16" (17) at sill
A R C H I T E C T U R A L D E T A I L F I L E 20-15 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
3/8"
3/4"
1/2"
1"
7/16" 7/16" 7/16"
7/8"3/4" 1-1/8"
200 Series Grille Options
Removable Interior Andersen® Finelight™ Grilles-Between-the-Glass
Removable Interior Wood Grille Profiles (chamfer profile).
Grille Profiles Scale = Full
Andersen® Finelight™ Grilles-Between-the-Glass
Standard Grille Options / AccessoriesContact an Andersen Representative for project specific grille options.
Window Profile Patio Door Profile
A R C H I T E C T U R A L D E T A I L F I L E20-16 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Extension jambs available for 4-9/16" (116), 5-1/4" (133), 6-9/16" (167) or 7-1/8"(181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 6-9/16" extension jamb is predrilled for easy application.
Horizontal Section
Extension Jambs for Circle Top™ (double-hung size) WindowsScale: 3”=1’-0” (1:4)
7-1/8"Wall
6-9/16"Wall
5-1/4"Wall
Unit Dim. Width
Optional Andersen®arched casing
Rough Opening Width
4-9/
16"
(116
)
5-1/
4" (1
33)
6-9/
16"
(167
)
7-1/
8" (1
81)2-
9/16
" (6
5)
Face
: 2"
(51)
Face
: 11/
16"
(17)
1/4" (6)
3/4" (19) at curve11/16" (17) at sill
A R C H I T E C T U R A L D E T A I L F I L E 20-17 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Trim Options and Applications—Circle Top™ and Elliptical Windows
Plinth BlocksScale: HalfAvailable in maple or oak.
For use with 2-1/4" or 2-1/2" (57mm or 64mm) casing.
2-7/8" (73mm)
1-1/8" R
2-7/8" (73mm)7/8" (22mm)
For use with 3-1/2" (89mm) casing.
3-7/8" (98mm) 1-1/2" R
3-7/8" (98mm)
7/8" (22mm)
Optional Andersen®
interior arch casing(Colonial or Ranch styles)
Optional Andersen® transom casing
Optional Andersen® plinth blocks
Interior trim by others
A R C H I T E C T U R A L D E T A I L F I L E20-18 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Circle Top™ Windows (casement/awning type),Circle and Oval
Circle Top™ Windows (double-hung type)
Elliptical
5/32" (4mm) typical
Ranch Style - WM 3242-1/4" x 11/16" (57mm x 17mm)
Available in select hardwoods.
Ranch Style - WM 3152-1/2" x 11/16" (64mm x 17mm)
Available in select hardwoods.
Colonial Style - WM 3662-1/4" x 11/16" (57mm x 17mm)
Available in select hardwoods.
Colonial Style - WM 3512-1/2" x 11/16" (64mm x 17mm)
Available in select hardwoods.
Colonial Style - WM 4443-1/2" x 11/16" (89mm x 17mm)
Available in select hardwoods..
5/32" (4mm) typical
5/32" (4mm) typical
Trim Options and Applications—Circle Top™ and Elliptical Windows
Interior CasingScale: FullAvailable for all cur ved portions of windows.
A R C H I T E C T U R A L D E T A I L F I L E 20-19 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Unit
Dim
ensi
onUn
itDim
ensi
onm
inus
1/2
"
5/16" (8)
Double-hungscrew locationsno. 10 x 2-1/4" screw
Picture/transomscrew locationsNo. 10 x 2-1/4" screw
Optional Andersen® steel reinforced join
Optional Andersen® 1-1/2" (38) casing(2" modified)
Narroline® Unit
Circle Top™ Unit (for double-hung)
Optional Andersen® trimstrip set incontinuousbead of sealanteach side
Circle Top™ Window over Narroline® Double-Hung Window
Non-Reinforced Transom
Joining Details—Circle Top™ Window
Steel Reinforced Transom
For narrow wood joining material: Overall unit dimension height = the sum of the individual unit heights – 3/8" (10mm)
Overall rough opening height = the sum of the individual unit heights – 3/8" (10mm)
Scale 3" = 1'-0" (1:4)
Narroline® Unit
Circle Top™ Unit (for double-hung)
Unit
Dim
ensi
onUn
it Di
men
sion
min
us 1
/2"
1/8" (3)
Optional Andersen®
trim strip set incontinuousbead of sealanteach side
Andersen® plinth blockbeyond
Optional Andersen® 1-1/2" (38) casing
For narrow steel joining material: Overall unit dimension height = the sum of the individual unit heights – 3/16" (5mm)
Overall rough opening height = the sum of the individual unit heights – 3/16" (5mm)
Circle Top™ Window over Circle Top™ Window(double-hung type) Scale 3" = 1'-0" (1:4)
Unit
Dim
ensi
onUn
itDim
ensi
on
1/8" (3)
Andersen® plinth block beyond
Wood blockingby others
Optional Andersen® 1-1/2" (38)insidetransomcasing
Circle Top™ Unit
Circle Top™ Unit
Optional Andersen® trim strip set incontinuousbead of sealanteach side
Non-Reinforced Joining
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting www.andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E20-20 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wood buck
Jamb clip flat
Optional Andersen® auxiliary casing
Window is secured in the opening by using threaded fasteners through the installation flange.
Anchoring Methods—Circle Top™, Elliptical, Circle and Oval Windows
Installation FlangeScale 3" = 1'-0" (1:4)
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Jamb ClipScale 3" = 1'-0" (1:4)
Window unit is secured in the opening by securing a side jamb clip to the unit, pre-drilling into masonry, inserting expansion sleeve, and driving flat head screw. Vinly flange to be cut, or removed, as required.
Window unit secured in opening by others using Andersen® 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clip to secure unit fit in opening. Installation flange can be cut as required to accommodate the jamb clip.
Installation flange
Exterior sheathing
Horizontal SectionCircle Top™ (double-hung)
or Elliptical Window
Expansion sleevewith flat head screw(furnished by others)
Horizontal SectionCircle Top™ (casement/awning),
Circle or Oval Window
Horizontal SectionCircle Top™ (double-hung)
or Elliptical Window
Countersinkand plug
Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
APPLICATION:
• First secure jamb clip to back side of window unit jamb(s)
• Apply 1' from corners of head jamb, sill and side jambs
• Space jamb clips evenly (maximum distance apart 32" on center)
• Jamb clip lateral design load capacity: maximum 200 lb.
A R C H I T E C T U R A L D E T A I L F I L E 20-21 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle Top™, Elliptical, Circle and Oval Windows
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Transom
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Installation flange all around
Optional Andersen®
3/4" x 5-1/2"(19 x 140)vinyl trimboard
Installationflangeall around
Andersen®
Narroline® window unit
Optional Andersen®
arch casing
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant Andersen® Narroline®
window unit
Removeinstallationflange all around
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant Andersen® Narroline®
window unit
Installationflange allaround
Membrane flashing over installationflange(by others)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E20-22 R E V . 0 3 / 0 5
S p e c i a l t y W i n d o w s
Wall Types Scale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications—Circle Top™, Elliptical, Circle and Oval Windows
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit
(CMU) Inset Window
Vertical SectionExisting Stud Wall
Vertical SectionExisting Masonr y Wall
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casingOptional Andersen® vinyl trim strip set in sealant Andersen® Narroline®
window unit
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Head
Transom Optional Andersen®
inside transom casing& plinth block
Optional Andersen®
interior arch casing
Optional Andersen® vinyl trim strip set in sealant
Andersen® Narroline®window unit
Existingframe wall
TransomOptional Andersen® vinyl trim strip set in sealant
Andersen®
Narroline®window unit
Optional Andersen®
inside transom casing & plinth blocks
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Transom Optional Andersen®
inside transom casing & plinth blocks
Optional Andersen® vinyl trim strip set in sealant
Andersen® Narroline®
window unit
Existing masonry wall
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Head
Optional Andersen®
arched extensionjamb trimmed to fit
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the
proper width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.