mussel zapper - s&s telemetrysstelemetry.com/pdf/zapper data sheet.pdfmussel zapper eliminates...

1
Mussels Attached to Influent Bar Screen Attributes: Application: Attributes: Applications: Water Plant Influent Bar Screen MZ-P1 Generates a "ELF" signal, (Species Specific), that eliminates Zebra Muscles and keeps them from reoccurring . * No Maintenance Required. * MZ-P1 has no effect on native aquatic species, (Species Specific). * Eliminates Zebra Mussels greater than or equal to1/2 mile away depending on impedance of Sine Waveguide. * Anode/Cathode: Supplied by "S&S" Telemetry Co. Supply Voltage Output#2 Mosfet: Max. 5.6 amps @ 100VDC rDS(ON) = 0.540Ω / Normal =< 6 M.A. @ 12 VDC Supply Current 250mA max Output #1 Product Description Product Description Product Specifications Product Specifications S&S Telemetry Co. 899 John George Ln. Sanger, TX 76266 PH: (940) 390-6932 FAX: (940) 458-5774 ID-22 Made in the USA S&S Telemetry Co. Pr Pr oduct Data oduct Data Mussel Zapper Eliminates Zebra Muscles Operating Temp/RH -20 to 150 o F (-28.9 to 65.6 o C) / 100% RoHS The MZ-P is covered by S&S's Five (5) Year Limited Warranty Wiring Diagrams available at www.sstelemetry.com Approval 12-18 VDC/+-10% Influent Piping Species Specific Design No Maintenance Din Rail Mounting LED Status SCADA Interface Raw Water Filters Under Water Infrastructure Holding Ponds Open Source/ High Impedance Wiring 1. Positive (+6-18 vdc) 2. Negative (-com) 3. Output #1 (Cathode) 4. Output #1 (Anode) 5. Output #2 (input Common) 6. Output #2 (input)

Upload: others

Post on 11-Mar-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Mussel Zapper - S&S Telemetrysstelemetry.com/pdf/ZAPPER DATA SHEET.pdfMussel Zapper Eliminates Zebra Muscles Operating Temp/RH-20 to 150o oF (-28.9 to 65.6 C) / 100% RoHS The MZ-P

Mussels Attached to Influent Bar Screen

Attributes:

Application:

Attributes:

Applications:Water Plant Influent Bar

Screen

MZ-P1 Generates a "ELF" signal, (Species Specific), that eliminates Zebra Muscles and keeps them from reoccurring .

* No Maintenance Required.

* MZ-P1 has no effect on native aquatic species,(Species Specific).

* Eliminates Zebra Mussels greater than or equal to1/2mile away depending on impedance of Sine Waveguide.

* Anode/Cathode: Supplied by "S&S" Telemetry Co.

Supply Voltage

Output#2

Mosfet: Max. 5.6 amps @ 100VDC rDS(ON) = 0.540Ω / Normal =< 6 M.A. @ 12 VDC

Supply Current 250mA max

Output #1

Product Description Product Description

Product Specifications Product Specifications

S&S Telemetry Co.899 John George Ln.

Sanger, TX 76266 PH: (940) 390-6932

FAX: (940) 458-5774

ID-22

Made in the USA

S&S Telemetry Co.

PrProduct Dataoduct Data

Mussel ZapperEliminates Zebra Muscles

Operating Temp/RH -20 to 150o F (-28.9 to 65.6o C) / 100%

RoHS

The MZ-P is covered by S&S's Five (5) Year Limited Warranty

Wiring Diagrams available at www.sstelemetry.com

Approval

12-18 VDC/+-10%

Influent Piping

Species Specific Design

No Maintenance

Din Rail Mounting

LED Status

SCADA Interface

Raw Water Filters

Under Water Infrastructure

Holding Ponds

Open Source/ High Impedance

Wiring 1. Positive (+6-18 vdc)2. Negative (-com)3. Output #1 (Cathode)4. Output #1 (Anode)5. Output #2 (input Common)6. Output #2 (input)