multivariable flow measurement

41
Prepared by Mustafa Ali , Senior Metering Tech, 1 03-12-08 Flow Measurement Through MULTIVARIABLE Transmitter

Upload: mustafa-ali

Post on 16-Apr-2017

2.736 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

1

03-12-08

FlowMeasurementThrough

MULTIVARIABLE Transmitter

Page 2: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

2

03-12-08

Conventional Flow Calculation FLOW COMPUTER / DCS

Page 3: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

3

03-12-08

Traditional DP TRANSMITTER, DP flow has been calculated in a DCS or flow computer using a simplified mass flow equation. In simplified DP mass flow measurements, a constant is used to represent many of the terms in the flow calculation

The constant combines unit conversion factor, velocity of approach factor, gas expansion factor, and discharge coefficient.

The simplified flow equation cannot compensate for changes in these terms, resulting in unrecorded errors in the calculated flow rate.

Conventional Flow Calculation FLOW COMPUTER / DCS

Page 4: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

4

03-12-08

Enhance Flow Calculation MULTIVARIABLE TRANSMITTER

Page 5: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

5

03-12-08

Qmass = Mass flow N = units conversion factorCd = discharge coefficientE = velocity of approach factorY1 = gas expansion factord2 = bore of differential producerDP = Differential pressurep = density

The MULTIVARIABLE TRANSMITTER (3095MV) provides the greatest DP flow accuracy over the widest operating range by dynamically calculating all flow equation coefficients real time, including discharge coefficients, velocity of approach factor, thermal expansion effects, and density.

This fully compensated flow equation reduces the sources of traditional DP flow uncertainty, thereby providing a more accurate flow calculation. It uses a fully compensated equation from mass flow through any differential producer

Enhance Flow Calculation MULTIVARIABLE TRANSMITTER

Page 6: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

6

03-12-08

How Does MULTIVARIABLE Tx3095MV Calculate Mass Flow?

Using the EA Software the user enters the process fluid (EA database already knows molecular weight, isentropic exponent, and constants), primary element type and size, and pressure and temperature operating conditions.

The Model 3095MV measures the static pressure, differential pressure, and process temperature.

The internal flow computer dynamically calculates all flow equation coefficients in real time including: discharge coefficient, velocity of approach factor, thermal expansion effects, and density Result is the greatest DP flow accuracy over the widest operating range!

Page 7: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

7

03-12-08

Page 8: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

8

03-12-08

Advantages of MULTIVARIABLE TRANSMITTER 3095MV

Primary element and fluid flexibility

Provides flow computer functionally in a single, compact package.

Dynamically Compensated mass flow

1% of mass flow rate accuracy over 10:1 flow range

Four measurements (Qm, DP, P, T) in one device providing real-time data to perform mass and heat balances across process units.

Output options 4-20 mA / HART based ,

Configuration of Pressure, Temp & DP through HART ,

Easy to configure with AMS & Engineering Assistant (EA) software

Page 9: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

9

03-12-08

The innovative technology and design of the Conditioning Orifice Plate enables multiple benefits without compromising performance.

The Conditioning Orifice Plate follows the discharge coefficient of the ISO 5167-2:2003(E) Conditioning Orifice Plate rivals the performance of the standard orifice plates while virtually eliminating straight pipe run requirements.

With sufficient straight run, the accuracy curve of the Conditioning Orifice Plate would follow the ISO 5167 standard.

Rosemout 1595 Conditioning Orifice Plate

Page 10: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

10

03-12-08

Conditioning Orifice Plate Technology is based on the same Bernoulli streamline energy equation and as a result follows the same Discharge Coefficientversus Reynolds Number relationship as standard orifice plates.

Installation in short straight pipe run, tight fit applications.

Improved performance in wet gas applications by allowingcondensate to pass and preventing the “damming” affectsuffered by standard orifice plates. None of the three standardsprovide allowances for drain vent holes in the orifice plate.

Rosemout 1595 Conditioning Orifice Plate

Page 11: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

11

03-12-08

Rosemout 1595 Conditioning Orifice Plate

Page 12: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

12

03-12-08

Rosemout 1595 Conditioning Orifice Plate

Page 13: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

13

03-12-08

Configuration with HART CommunicatorConfiguration with AMS / Engineering Assistant (EA) software

Page 14: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

14

03-12-08

Configuration with AMS / Engineering Assistant (EA) software

Page 15: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

15

03-12-08

Process parameters Display

Configuration with AMS / Engineering Assistant (EA) software

Page 16: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

16

03-12-08

Configuration with AMS / Engineering Assistant (EA) software Flow configuration wizard

Page 17: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

17

03-12-08

Configuration with AMS / Engineering Assistant (EA) software

Page 18: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

18

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareGas Calculation Method Selection

Page 19: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

19

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareGas Composition for Density measurement

Page 20: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

20

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwarePrimary Element 1595 Conditioning Orifice Plate selection

Page 21: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

21

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareOperating envelope (Pressure & Temperature)

Page 22: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

22

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareAuto Compressibility Calculation for corrected volume

Page 23: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

23

03-12-08

Configuration with AMS / Engineering Assistant (EA) software Configuration properties

Page 24: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

24

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 25: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

25

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 26: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

26

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 27: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

27

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 28: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

28

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 29: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

29

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 30: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

30

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 31: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

31

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 32: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

32

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 33: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

33

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 34: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

34

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 35: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

35

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 36: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

36

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 37: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

37

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareConfiguration properties

Page 38: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

38

03-12-08

Configuration with AMS / Engineering Assistant (EA) software

Online Validation on DP, Pressure & Temperature

Page 39: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

39

03-12-08

Configuration with AMS / Engineering Assistant (EA) softwareParameters display

Page 40: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

40

03-12-08

Page 41: Multivariable Flow Measurement

Prepared by Mustafa Ali , Senior Metering Tech,

41