multiswitch power pack - grundig systems · english class klasse pdp 900 multiswitch power pack gss...
TRANSCRIPT
![Page 1: Multiswitch Power Pack - Grundig Systems · English CLASS KLASSE PDP 900 Multiswitch Power Pack GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D-90471 Nuremberg Phone: +49 (0)](https://reader031.vdocuments.mx/reader031/viewer/2022013014/5ad184fe7f8b9aff738bce7d/html5/thumbnails/1.jpg)
Engl
ish
CLASS
KLASSE
PDP 900
Multiswitch Power Pack
GSS Grundig SAT Systems GmbHBeuthener Strasse 43D-90471 Nuremberg
Phone: +49 (0) 911 / 703 8877Fax: +49 (0) 911 / 703 9210E-mail: [email protected]: http://www.gss.de
![Page 2: Multiswitch Power Pack - Grundig Systems · English CLASS KLASSE PDP 900 Multiswitch Power Pack GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D-90471 Nuremberg Phone: +49 (0)](https://reader031.vdocuments.mx/reader031/viewer/2022013014/5ad184fe7f8b9aff738bce7d/html5/thumbnails/2.jpg)
- 2 - PDP 900
1 Important information on the safety and assembly
• Assemblyandservicingshouldbecarriedoutbyelectricians. • Checkthesystemforshortcircuitsinthecoaxialcablesbeforestartingup. • Onlyinstallthesystemwhenitisnotconnectedtothemainssupply(230V). • Mountthepowerpackandthemultiswitches… - onanon-flammablebackground(wall), - inadust-free,dryenvironment, - insuchamannerthatitisprotectedfrommoisture,fumes,splashingwater
anddampness, - somewhereprotectedfromdirectsunlight, - notwithintheimmediatevicinityofheatsources, • Ensurethatthesystemisadequatelyventilated. Donotcovertheventilationslots! • Bewareofshortcircuits! • Noliabilityisacceptedforanydamagecausedbyfaultyconnectionsor
inappropriatehandling. • Observe the relevant standards, regulations and guidelines (IEC/EN/
DINEN60065etc.).
Electronic devices should never be disposed of in the household rubbish. In accordance with directive 2002/96/EC of the European Parliament and the European Council from January 27, 2003 which addresses old electronic and electrical devices, such devices must be disposed of at a designated collection facility. At the end of its service life, please take your device to one of these public collection facilities for proper disposal.
2 Technical description
ThepowerpackisonlyusedinconjunctionwiththecascadedmultiswitchesofaSATreceiversystemtosupplypowertotheconnectedLNBs.
ThepowersupplytotheLNBscomesfromtheSAT-IFinputsofthemultiswitch-es.Cascadedmultiswitchesonlyneedonepowerpack,whichcanbefittedtoanymultiswitch.TheSAT-IFinputsandoutputsareD.C.coupled.ThiscarriesthevoltagetoalltheSAT-IFlines.
![Page 3: Multiswitch Power Pack - Grundig Systems · English CLASS KLASSE PDP 900 Multiswitch Power Pack GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D-90471 Nuremberg Phone: +49 (0)](https://reader031.vdocuments.mx/reader031/viewer/2022013014/5ad184fe7f8b9aff738bce7d/html5/thumbnails/3.jpg)
- 3 - PDP 900
3 Assembly
• Unscrewthe2screwsAatthePDC…. • ConnecttheDCoutput(+18VDCOUT)ofthepowerpacktotheDCinput
(+18VDCIN)ofthePDC….
A
A
+18V DCIN
+18V DCOUT
• Screwthepowerpacktightlywiththe2screwsA.
A
Power LED
Ventilation openings
Ventilation openings
![Page 4: Multiswitch Power Pack - Grundig Systems · English CLASS KLASSE PDP 900 Multiswitch Power Pack GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D-90471 Nuremberg Phone: +49 (0)](https://reader031.vdocuments.mx/reader031/viewer/2022013014/5ad184fe7f8b9aff738bce7d/html5/thumbnails/4.jpg)
• Tighten4screwsB.
B
4 Specification
PDP 900Mainsvoltage 100-230VAC,50/60HzOutputvoltage 18VDCMax.outputcurrent 1000mADCAmbienttemperature -20°C…+50°CDimensions(WxHxD)[mm]approx. 70x133x55
Service:Phone:+49(0)911/7032221•Fax:+49(0)911/7032326•Email:[email protected]•BeuthenerStraße43•D-90471Nürnberg
Alterations reserved. Technical data E. & O.E. © by GSS GmbH 08062010