Amey Patil(BT11EEE05)
Amey Khot(BT11EEE06)
Charudatt Awaghate(BT11EEE18)
Srikant Pillai (BT11EEE51)
Purushotam Kumar (BT11EEE53)
![Page 3: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/3.jpg)
Introduction
3
• To reduce the ripple content in the output and to improve the power quality inverters need very high switching frequency and various PWM strategies.
• In 2-level inverter output voltage waveform is produced by using PWM with two voltage levels.
• This has limitations at high voltage. This causes the output voltage and current to be distorted and the THD of the voltage is poor.
• Hence multi-level inverters are used.
![Page 4: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/4.jpg)
Classification of High Power Converters
4
![Page 5: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/5.jpg)
Multilevel ConvertersADVANTAGE
• They are able to generate high output voltages with very low distortion and lower dv/dt.
• They are able to bring in input current with very low input distortion.
• Well suited for reactive power compensation.
• They can be functioned with a much lower switching frequency.
DISADVANTAGE
• it required a huge amount of semiconductors switches.
• It required isolated voltage sources or a bank of series capacitors for voltage balancing.
5
![Page 6: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/6.jpg)
• APPLICATIONS
1. DC power source utilization
2. Uninterruptible power supplies
3. HVDC power transmission
4. Variable-frequency drives
5. Electric vehicle drives
6. Air conditioning
6
![Page 7: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/7.jpg)
Comparison of conventional two level inverters and multilevel inverters
7
![Page 8: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/8.jpg)
Concept• Multi-level inverters are the modification of basic
bridge inverters. They are normally connected in series to form stacks of level.
The topological structure of multilevel inverter must cope with the following points-
1. It should have less switching devices as far as possible.
2. It should be capable of enduring very high input voltage such as HVDC transmission for high power applications.
3. Each switching device should have lower switching frequency owing to multilevel approach. 8
![Page 9: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/9.jpg)
TYPES OF MULTILEVEL INVERTERS
9
![Page 10: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/10.jpg)
Diode Clamped Multi-Level Inverter• Advantages
1. When the number of levels is high enough, harmonic content will be low enough to avoid the need for filters.
2. Efficiency is high due to all devices which are being switched at the fundamental frequency.
3. We are able to control the reactive power flow.
4. The control method is easy for a back to back intertie system
10
![Page 11: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/11.jpg)
Disadvantages1.Excessive clamping diodes are being required when the number of levels get high.2.It is hard to do a real power flow control for individual converter.
SWITCHING SEQUENCE for 5 level
output s1 s2 s3 s4 s1’ s2’ s3’ s4’
Vdc 1 1 1 1 0 0 0 0
3Vdc /4 0 1 1 1 1 0 0 0
Vdc/2 0 0 1 1 1 1 0 0
Vdc/4 0 0 0 1 1 1 1 0
0 0 0 0 0 1 1 1 1
11
![Page 12: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/12.jpg)
Flying capacitor multi-level inverter
• Advantages1. Huge amount of storage capacitors
will provide additional ride through capabilities during power rage.
2. Switch combination redundancy are provided for balancing different voltage levels.
3. When the number of levels is high enough, the harmonic content will be low enough not to use the filter.
4. We are able to control both the real and reactive power flow, and making a possible voltage source converter candidate for high voltage dc transmission
12
![Page 13: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/13.jpg)
Disadvantages1.When the number of converter levels get high, a huge amount of storage capacitor is required. Those high level systems are more difficult to package and those bulky capacitors are expensive.2.The switching frequency and switching losses will sore high for real power transmission and the converter control will get very complicated.
SWITCHING SEQUENCE for 5 level output s1 s2 s3 s4 s1’ s2’ s3’ s4’
Vdc 1 1 1 1 0 0 0 0
3Vdc/4 1 1 1 0 0 0 0 1
Vdc/2 1 1 0 0 0 0 1 1
Vdc/4 1 0 0 0 0 1 1 1
0 0 0 0 0 1 1 1 113
![Page 14: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/14.jpg)
Cascaded Multi-level Inverter• Advantages:1. The modularized structure
allows easy packaging and storage.
2. The quantity of possible voltage levels is more than DC and FC type.
• Disadvantages:1. Separated DC sources or
capacitor are required for each module.
2. A More complex controller is required due to the amount of capacitors, which need to be balanced.
14
![Page 15: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/15.jpg)
Phase waveform for 5-Level CHB Inverter
15
![Page 16: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/16.jpg)
COMPARISON AMONG MULTILEVEL INVERTERS INAPPLICATION ASPECTS
ADVANTAGE
• Compared with other multi level inverter configurations cascaded type requires least number of components to similar voltage level
• Since each structure is similar packaging and circuit layout can be optimized effectively.
• Soft switching techniques can be used to reduce switching losses and device stresses.
DISADVANTAGE
• It needs separate DC power sources there by limiting its utility and applications
16
![Page 17: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/17.jpg)
Comparison of different multilevel inverter topologies
17
![Page 18: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/18.jpg)
Multi-level Inverters TopologiesCHB Inverter with Equal dc Voltage
As the name suggests, the cascaded H-bridge multilevel inverter uses multiple units of H-bridge power cells connected in a series chain to produce high ac voltages. A typical configuration of a five-level CHB inverter is shown in Fig. below, where each phase leg consists of two H-bridge cells powered by two isolated dc supplies of equal voltage E.
18
![Page 19: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/19.jpg)
3Phase 5 level CHB Inverter
19
![Page 20: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/20.jpg)
Unipolar PWM with two phase-shifted modulating waves (mf = 15, ma = 0.8, fm = 50 Hz, and fcr = 750 Hz).
20
![Page 21: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/21.jpg)
Switching table for 5 level CHB inverter
21
![Page 22: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/22.jpg)
2 cell 7 level inverter CHBUnequal Dc Voltages
22
![Page 23: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/23.jpg)
Carrier based PWM schemes
The carrier-based modulation schemes for multilevel inverters can be generally classified into two categories: phase-shifted and level-shifted modulations. Both modulation schemes can be applied to the CHB inverters.
23
![Page 24: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/24.jpg)
Phase shifted carrier scheme
In general, a multilevel inverter with m voltage levels requires
• (m – 1) triangular carriers
• In the phase-shifted multicarrier modulation, all the triangular carriers have the same frequency and the same peak-to-peak amplitude, but there is a phase shift between any two adjacent carrier waves, given by
• Phcr = 360°/(m – 1).
24
![Page 25: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/25.jpg)
5 Level inverter phase shifted carrier wave
25
![Page 26: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/26.jpg)
Level-Shifted Multicarrier Modulation
• It requires (m-1) triangular carriers, all having the same frequency and amplitude.
• The frequency modulation index is given by mf = fcr/fm.
• The switching frequency of the inverter using the level-shifted modulation is equal to the carrier frequency, that is, fsw,inv = fcr
• Average device switching frequency is fsw,dev = fcr/(m – 1)
• The conduction time of the devices is not evenly distributed either.
26
![Page 27: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/27.jpg)
where ˆVm is the peak amplitude of the modulating wave vmand ˆVcr is the peak amplitude of each carrier wave.
There are three schemes for the level-shifted multicarrier modulation:
(a) In-Phase Disposition (IPD), where all carriers are in phase;
(b) Alternative Phase Opposite Disposition (APOD), where all carriers are alternatively in opposite disposition; and
(c) Phase Opposite Disposition (POD), where all carriers above the zero reference are in phase but in opposition with those below the zero reference.
27
![Page 28: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/28.jpg)
Level-shifted multicarrier modulation for five-level inverters28
![Page 29: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/29.jpg)
• vAN is composed of 5 voltage levels while the line to-line voltage vAB has 9 voltage levels.
• The dominant harmonics in vAN and vABappear as sidebands centered around mf.
• The inverter phase voltage contains triplenharmonics, such as mf and mf ± 6, with mf being a dominant harmonic.
• Since these harmonics do not appear in the line-to-line voltage, the THD of vAB is less than vAN.
29
![Page 30: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/30.jpg)
Phase-Shift Sine PWMLine & Phase Voltage (Ma=0.8, mf=3)
30
![Page 31: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/31.jpg)
IPD RMSMa=0.9 Mf=20
31
![Page 32: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/32.jpg)
POD RMSMf=20 Ma=0.8
32
![Page 33: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/33.jpg)
APOD RMSMf=20 Ma=0.8
33
![Page 34: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/34.jpg)
Phase-Shift Sine PWMLine & Phase voltage (Ma=0.6, Mf=15)
34
![Page 35: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/35.jpg)
Line & Phase Voltage (Ma=0.8, mf=15)
35
![Page 36: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/36.jpg)
Line & Phase Voltage (Ma=1, mf=15)
36
![Page 37: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/37.jpg)
FFT analysis of Phase Shifted CHB Inverter at Ma=.8 and Mf=5
37
![Page 38: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/38.jpg)
FFT analysis of Phase Shifted CHB Inverter at Ma=.8 and Mf=10
38
![Page 39: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/39.jpg)
FFT analysis of Phase Shifted CHB Inverter at Ma=.8 and Mf=15
39
![Page 40: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/40.jpg)
FFT analysis of Phase Shifted CHB Inverter at Ma=.8 and Mf=20
40
![Page 41: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/41.jpg)
Unbalanced (2 cell) 7 level CHB Inverter
41
![Page 42: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/42.jpg)
Unbalanced 7 level inverter FFT
42
![Page 43: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/43.jpg)
Unbalanced 7 level inverter THD
43
![Page 44: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/44.jpg)
Unbalanced 9 level inverter
44
![Page 45: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/45.jpg)
Unbalanced 9 level inverter FFT
45
![Page 46: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/46.jpg)
Unbalanced 9 level inverter THD
46
![Page 47: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/47.jpg)
IPD RMSMa=0.9 Mf=20
47
![Page 48: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/48.jpg)
IPD FFTMa=0.9 Mf=20
48
![Page 49: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/49.jpg)
IPD THD
49
![Page 50: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/50.jpg)
POD RMSMf=20 Ma=0.8
50
![Page 51: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/51.jpg)
POD FFT
51
![Page 52: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/52.jpg)
POD THD
52
![Page 53: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/53.jpg)
APOD RMSMf=20 Ma=0.8
53
![Page 54: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/54.jpg)
APOD FFT
54
![Page 55: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/55.jpg)
APOD THD
55
![Page 56: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/56.jpg)
Phase Sifted CHBCurrent through S11
56
![Page 57: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/57.jpg)
Phase Sifted CHBCurrent through One Leg
57
![Page 58: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/58.jpg)
Level Shift CHBCurrent through S11
58
![Page 59: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/59.jpg)
Level Shift CHBCurrent through S21
59
![Page 60: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/60.jpg)
Level Shift CHBCurrent through one leg
60
![Page 61: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/61.jpg)
Level Shift CHBCurrent through S21 and S22
61
![Page 62: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/62.jpg)
Comparison Between Phase- and Level-Shifted PWM Schemes
Assumption
• The average switching frequency of the solid-state devices is the same for both schemes.
• All the devices operate at the same switching frequency and conduction time.
62
![Page 63: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/63.jpg)
Comparison Between the Phase- and Level-Shifted PWM Schemes
63
![Page 64: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/64.jpg)
RMS Voltage Variation with Ma at Mf=15
64
Ma Phase voltage RMS Line voltage RMS
0.6 92 151
0.8 120 204
1 146 252
![Page 65: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/65.jpg)
THD(%) Analysis of Line Voltages of CHB Inverter based on Different Schemes
at Mf=20 Vdc=100
Ma PHASE SHIFTED IPOD 2 CELL 7 LEVEL 2 CELL 9 LEVEL
0.2 68.6 25.59 153.55 167
0.4 68 25.57 79.67 91.625
0.6 27 25.5 40.72 53.46
0.8 29 21.73 36.01 42.56
1 25 16.9 27.65 30
65
![Page 66: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/66.jpg)
THD profile of vAB produced by the five-level CHB inverter with phase and level-shifted modulation schemes.
0.2 0.4 0.6 0.8 1
Phase Shifted PWM 68.6 68 48 35 27 26 25 25
IPD 25.59 25.57 25.55 25.52 25.5 23 21.73 16.9
0
10
20
30
40
50
60
70
80
THD
MA
Fsw,dev=1000HzFive Level Inverter
Phase Shifted PWM IPD
66
![Page 67: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/67.jpg)
SUMMARYFeatures of CHB INVERTERModular structure: Multiple units of identical H-
bridge power cells ,leads to a reduction in manufacturing cost.
Lower voltage THD and dv/dt: Due to Output voltage is formed by several voltage levels with small voltage steps leads to much lower THD and dv/dt.
High-voltage operation without switching devices in series: The H-bridge power cells are connected in cascade to produce high ac voltageseliminates the problems of equal voltage sharing for series-connected devices.
67
![Page 68: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/68.jpg)
Drawbacks
Large number of isolated dc supplies. The dc supplies for the CHB inverter are usually obtained from a multi pulse diode rectifier employing an expensive phase shifting transformer.
High component count. The CHB inverter uses a large number of IGBT modules. A nine-level CHB inverter requires 64 IGBTs with the same number of gate drivers.
68
![Page 69: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/69.jpg)
Proposed Work in next phase II
In this phase we have addressed the different type of controlling method, We did simulation and we are obtaining good response by using these topologies.so in next phase we will work on Hardware part of it.
In next phase we will address the Hardware part
Of Five level CHB using Unipolar Phase-Shifted carrier based sine PWM topology.
69
![Page 70: Multi level inverter for Cascaded H-bridge 3 Phase Five Level](https://reader031.vdocuments.mx/reader031/viewer/2022020110/55a68d731a28abc57d8b470e/html5/thumbnails/70.jpg)
REFERENCES1. W. A. Hill and C. D. Harbourt, Performance of Medium Voltage
Multilevel Inverters,IEEE Industry Applications Society (IAS) Conference, Vol. 2, pp. 1186–1192, 1999
2. P. W. Hammond, A New Approach to Enhance Power Quality for Medium Voltage AC Drives, IEEE Transactions on Industry Applications, Vol. 33, No. 1, pp. 202–208, 1997.
3. P.S.BHIMBRA, POWER ELECTRONICS.4. M.RASHID, POWER ELECTRONICS.5. N. Mohan, T. M. Undeland, et al., Power Electronics—
Converters, Applications and Design, 3rd edition, John Wiley & Sons, New York, 2003.
6. Web link-https://www.academia.edu/6742849/Multilevel_Inverter_3-level_topologies_Diode_and_capacitor_clamped_and_controlscheme_spwm_
70