multi functional cctv tester - supercircuits · 10 multi functional cctv tester 11 multi functional...

19
P/N : 388087345 PRINTED IN KOREA Rapport mini HD Multi Functional CCTV Tester FAR OPEN TELE OSD NEAR CLOSE WIDE COM V/ 300V 300V~ MAX V ~ ~ MODE SET

Upload: others

Post on 18-Apr-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

P/N : 388087345 PRINTED IN KOREA

Rapport mini HDMulti Functional CCTV Tester

FAROPEN

TELEOSD

NEARCLOSE WIDE

COM V/

300V 300V~MAX

V~ ~♬

MODE SET

TABLE OF CONTENTS TABLE OF CONTENTS

BEFORE USING Rapport mini HD

SAFETY INFOMATION

PRODUCT INTRODUCTION

Product Introduction

Part name & Functions

Product Specification

Dimension

LED Indicator

FUNCTIONS

Power ON/OFF

Mode setup

Video Tester

Switch CVBS, HD-SDI and HD-TVI

Digital Multimeter

Measuring AC & DC Voltage

Measuring Resistance

Continuity Testing

PTZ Controller

SPD(SPEED)

GPST(GO TO PRESET)

SPST(SET PRESET)

FUNC

MENU

4

5

6

6

8

12

14

15

16

16

17

18

20

22

24

25

25

26

28

29

29

29

30

DATA

SETUP

USER NAME

SLEEP TIME

BEEP

SYMBOLS

31

33

34

34

34

35

02 MULTI FUNCTIONAL CCTV TESTER 03 MULTI FUNCTIONAL CCTV TESTER

Be sure to read through the "Safety Information" section before using this Rapport mini HD.

GeneralPrecautions

Pay attention to the following precautions when usingthe Rapport mini HD.

BEFORE USING Rapport mini HD

This basic instruction manual is for users of the Rapport mini HD. Starting with an outline of this Rapport mini HD, the manual explains its operation,how it connects to other devices, how to use the menu buttons,and how it should be operated. It is highly recommended, even for those who have handled similar devices, as well as for those using it for the first time, to read all the instructions thoroughly, especially the precautions, before using the Rapport mini HD. If there are any questions which arise when using the Rapport mini HD or the unit is damaged, please contact the supplier of your Rapport mini HD.Safety Information highlights and explains the precautions which should be taken, for the safety of users, when using the Rapport mini HD.

When using the Digital MultiMeter function to measure voltage or current, be sure that the input does not exceed the capabilities of the tester. Overloading the tester can cause damage or personal injury.

When measuring current of unknown values, always begin with the 10A mode, then step down to the 400mA input if necessary.

Environmental Limitations

Temperature: -10 to 50 degrees CRelative Humidity: 30% -90%DC input voltage: 12V +/-10%, 1A

Rapport mini HD Safety Precautions

-Use only specified replacement fuses.-Do not use damaged test leads with the DMM.-When using the DMM function, set the proper mode before connecting to the circuit under est.-When measuring resistance, make certain that the circuit is de-energized before connecting the test leads to the circuit.-Do not measure resistance on powered circuits.-Do not use the unit in damp, humid or gaseous environments.-Do not touch it with wet hands.-Be mindful not to shock or shake the unit while in use to avoid damage.-Avoid areas with strong magnetic or electromotive fields, which can cause incorrect measurements.-Remove the power plug from the outlet when there is a lighting storm. -Neglecting to do so may cause fire or damage to the product.-The Main plug is used as a disconnect device and shall stay readily operable at any time.-Be sure to use only the standard adapter that is specified in the specification sheet.-Using any other adapter could cause fire, electrical shock, or damage to the product.-Securely plug the power cord into the power receptacle. Insecure connection may cause fire.-If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the power source and contact the service center. Continued use in such a condition may cause fire or electric shock.-When cleaning, do not spray water directly onto parts of the product. Doing so may cause fire or electric shock

SAFETY INFORMATION

04 MULTI FUNCTIONAL CCTV TESTER 05 MULTI FUNCTIONAL CCTV TESTER

• Rapport mini HD • Accessories

BNC cablePower Adaptor

Test lead body cover

MANUAL

manual

Rapport mini HD has a built-in Lithium Polymer Battery.

It can be recharged using a DC12V power adapter with an output of 1A or above and reaches its full charge after a period in excess of 5 hours. After the battery has been fully charged for the first 2~3 charging cycles, it can be used for approximately 6 hours (up to a Max.8 hrs in normal operation).The battery can be recharged by connecting it to the DC adapter, regardless of OSD power, when the slider switch has been turned on.

The discharge operation starts when the Main Switch is turned on and it then consumes power from the battery. Therefore, when the Rapport mini HD is not being used for a period of time, make sure the Main Switch is turned off.

PRODUCT INTRODUCTION PRODUCT INTRODUCTION

Summary

Standard ItemsCheck the contents of your Rapport mini HD package against the standard checklist below.

Designed, with portability and serious CCTV engineers in mind, the Rapport mini HD is an advanced piece of video test equipment consisting of many useful test functions needed to professionally install a CCTV system; test functions include Video quality, Service Monitor, Multimeter, PTZ Test, RS-422 and RS-485 Communication Test, etc.

Product Introduction

Test Leads

AdaptorBNC to BNC Cable

MANUAL

• Package

FAROPEN

TELEOSD

NEARCLOSE WIDE

COM V/

300V 300V~MAX

V~ ~♬

MODE SET

FAROPEN

TELEOSD

NEARCLOSE WIDE

COM V/

300V 300V~MAX

V~ ~♬

MODE SET

06 MULTI FUNCTIONAL CCTV TESTER 07 MULTI FUNCTIONAL CCTV TESTER

MODE

SET

FAROPEN

TELEOSD

NEARCLOSE

WIDE

① : Common Port, Lead for black color

② : Voltage & Resistance Port, Lead for red color

PRODUCT INTRODUCTION PRODUCT INTRODUCTION

Part name & Functions

Power LED

Charge LED

Data Transmitting LED

Data Receiving LED

LCD

Keypad

MODE Button

SET Button

PTZ mode

Red LED is on when the system is switched on.

Green LED is on when the battery is fully charghed.

Red LED is on when PTZ data is transmitted.

Green LED is on when PTZ data is received.

2.4” Color TFT LCD

Main keypad for Rapport mini HD operation

Mode Select: Video, MultiMeter, PTZ Control.

Used to confirm selection in menu screens.

(Press for 2 seconds to power on.)

Adjusts PTZ Focus Far Operation.

IRIS OPEN

Part Name Function

Part Name Function

PTZ mode

PTZ mode

PTZ mode

PTZ mode

Test Lead Connection : Ports for Digital MultiMeter

V/

COM

Adjusts PTZ Focus Near OperationIRIS Close

Adjusts PTZ Focus Zoom-in Operation

Clear OSD of PTZ mode

Adjusts PTZ Focus Zoom-out Operation

PTZ Mode : Moves PTZ Up/Down/Left/& Select Menu -> Enter(Select video mode in mode screen, press button for 3sec to switch HD-SDI, CVBS and HD-TVI)

① ② ③ ④

FAROPEN

TELEOSD

NEARCLOSE WIDE

COM V/

300V 300V~MAX

V~ ~♬

MODE SET

COM V/

300V 300V~MAX

V ~♬

① ②

08 MULTI FUNCTIONAL CCTV TESTER 09 MULTI FUNCTIONAL CCTV TESTER

① DC Power Jack : DC Power Input Jack (DC12V, 1A)② Power Switch : Main Power Supply ON/OFF switch

Internal Battery Cover

① Communication Port : Input & Output of PTZ communications signals (RS 422/ RS485, Rx+, Rx-, Tx+, Tx- )

PRODUCT INTRODUCTION PRODUCT INTRODUCTION

② Video IN : Select function in video selection mode. Video IN : The input video signal of CVBS(NTSC / PAL), HD-SDI and HD-TVI display to the LCD (Press button for 3 sec to switch video mode.)

① ②

10 MULTI FUNCTIONAL CCTV TESTER 11 MULTI FUNCTIONAL CCTV TESTER

Electrical Specifications

Functional Specifications

Multi-meter Specifications

PRODUCT INTRODUCTION PRODUCT INTRODUCTION

Mode Range MinimumMeasuring

Accuracy

DC Voltage

400mV 100uV

4V 1mV

40V 10mV

300V 100mV

AC Voltage

4V 1mV

40V 10mV

300V 100mV

Resistance

400Ω 0.1Ω

4㏀ 1Ω

40㏀ 10Ω

400㏀ 100Ω

4MΩ 1㏀

40MΩ 10㏀

Continuity Beeper is activated when the resistance is low.

±(2.5% +4dgts)

±(2.5% +4dgts)

±(2.5% +4dgts)

±(2.0% +4dgts)

±(2.0% +2dgts)

±(2.0% +4dgts)

±(3.0% +5dgts)

(40㎐ ~ 500㎐)

Note : Maximum voltage drop approx 2V on the measuring current.

ElectricalCharacteristic

Input Voltage

Battery

Built-in charger

Display

Display Resolution

Working Temp.

Dimension

DC 12V ± 10%, 1A

7.4V (3.7x2)Li-Poly, 2000mAh

Charging Time : 6 hour

Operation Time : 8 hour

2.4" TFT-LCD (Digital), RGB666

320 x 240

-10℃~50℃

L159.3 x W79.1 x T32.2 (mm)

Video Mode

Video IN

LCD Adjustment

CVBS Signal Mode

HD-SDI Format

Communication

PTZ Protocol

Baud rate

Rx Data Analyzer

CVBS, BNC IN, 1.0 Vpp

HD-SDI

HD-TVI

Brightness, contrast

NTSC/PAL (Auto adapt)

720p 50fps / 59.94fps / 60fps

1080i 50fps / 59.94fps / 60fps

1080p 23.98fps / 24fps / 25fps / 29.97fps / 30fps

1080p 50fps / 59.94fps / 60fps

RS422, RS485

Multi (24 protocols)

2400bps~1152000bps

Hex Value Analysis

DC Voltage Range

AC Voltage Range

Continuity

Resistance Range

400mV/4V/40V/300V

4V/ 40V/300V

Built-in Buzzer sound

400Ω/4KΩ/40KΩ /400KΩ/4MΩ/40MΩ

HD-TVI Format

720p 25fps / 30fps

720p 50fps / 60fps

1080p 25fps / 30fps

PTZ Controller

Digital Multi-Meter

12 MULTI FUNCTIONAL CCTV TESTER 13 MULTI FUNCTIONAL CCTV TESTER

Dimension

OFF

OFF

ON

OFF

OFF

ON

OFF

Flicker(1 Hz)

Item RED LED GREEN LED

PRODUCT INTRODUCTION PRODUCT INTRODUCTION

LED Indicator

On charging : RED LED ONFully charged: GREEN LED ON

Shift power switch off to Power on The LED turns Red or Green depend on the recharging status.

Discharged

Charging

Fully charged

Low battery

Battery is consumable item with 6 months warranty after purchase.Use the manufacture provided adaptor only (DC12V/1A).When Red LED flicker, reload battery or recharge battery.

* L159.3 x W79.1 x T32.2 (mm)

TxRx

PWRCHG

159.3

66.5

63.8

79.1

32.2

FAROPEN

TELEOSD

NEARCLOSE WIDE

COM V/

300V 300V~MAX

V~ ~♬

MODE SET

14 MULTI FUNCTIONAL CCTV TESTER 15 MULTI FUNCTIONAL CCTV TESTER

After Operating with Power on- On charging: RED LED ON- Fully charged: GREEN LED ON * When it charge during operating, the screen show like ▶.(▶: DC Adaptor connect and Charge, ◀: Operated by Battery)

MODE

MODEMODE

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SET

[ Mode change ]

• Video Tester (Color CCTV Field Monitor) Video IN : Select input video signal(CVBS, HD-SDI, HD-TVI) - CVBS - HD-SDI - HD-TVI• Digital Multi-meter• PTZ Controller• Receive Data Analyzer• Setup

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SETVIDEO NTSCBRI 3 CON 7

METER PTZ SETUPVIDEO DATA0101

Power ON/OFF

The power switch is located on the side of the handset.Turn the power switch on, and press to start Rapport mini HD.To turn off the system, press & hold for more than 2 sec. Then, POWER OFF is displayed on the main screen with a beep. Release the button. Turn the power switch OFF to prevent battery drain during storage. The switch must remain ON to recharge the batteries.A rechargeable battery should be plugged in over 5 hours to fully charge. The charged battery can operate for about 8 hours.When the battery indicator shows below , recharge it for use. (Full charge: )

FUNCTIONSFUNCTIONS

After the power is applied the above on-screen message is displayed. Approximately 2 seconds later the screen switches to the last OSD before power was turned off. The Rapport mini HD stores the last accessed OSD.The initial OSD message displays the Rapport mini HD's firmware information. Versions of the product change whenever new firmware is uploaded.

Mode setup

Main Functions

The MODE SELECT menu is displayed when the key is depressed and moves to the next menu whenever the key is pressed

The OSD menu changes whenever the key is pressed, and sequences through in the following order :

VIDEO -> Meter -> PTZ controller -> Receive Data -> SETUP ->VIDEO

SET

SET

MODE SET

TxRx

PWRCHG

MODE SET

TxRx

RAPPORT-MINI Ver : X.XX

PWRCHG

HDSDI/CVBS

16 MULTI FUNCTIONAL CCTV TESTER 17 MULTI FUNCTIONAL CCTV TESTER

[ Video Tester mode ]

VIDEO

IN

VIDEO NTSC

[ Video Mode ]

① VIDEO : Indicates Current Mode.② NTSC : Indicates NTSC or PAL System. (LOSS: No video) - CVBS(LOSS : No Video, NTSC, PAL) - HD-SDI(LOSS : No Video, input video information) - HD-TVI(LOSS : No Video, input video information)③ Indicates remained battery. ④ Indicates screen brightness, and brightness increases by +1 when the FAR key is pressed, and decreases by -1 when the NEAR key is pressed.⑤ Indicates screen contrast, and contrast increases by +1 when the TELE key is pressed, and decreases by -1 when the WIDE key is pressed. ⑥ Indicates SET & Indicates OSD clear button⑦ Indicates Mode, and changable by MODE button.⑧ Indicates Current Video

[ OSD clear ]

FUNCTIONSFUNCTIONS

Video Tester

( : DC Adaptor connected : Operated by Battery)

※ If there is no video signal at the VIDEO IN port of the Rapport mini HD “LOSS” will be displayed.

VIDEO NTSCBRI 3 CON 7

MODE CLRCVBS

You can check the CVBS, HD-SDI, HD-TVI video signal and determine the input video type with this video tester function

VIDEO NTSCBRI 3 CON 7

MODE CLRCVBS

①④

⑦ ⑥

②③⑤

(press button for 3sec to switch HD-SDI, CVBS and HD-TVI)

18 MULTI FUNCTIONAL CCTV TESTER 19 MULTI FUNCTIONAL CCTV TESTER

FUNCTIONSFUNCTIONS

Switch CVBS, HD-SDI and HD-TVI

Select input video

Zoom in image

VIDEO HD 1080i60BRI 3 CON 7

MODE CLRHDSDI

VIDEO NTSCBRI 3 CON 7

MODE CLRCVBS

[ HD-SDI ] [ CVBS ]

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SET

You can move the image by pressing direction keys.

This product support to select the video mode, input video image of CVBS, HD-SDI and HD-TVI. Press button for 3 sec to switch video mode.

Press button to zoom in the HD-SDI and HD-TVI image.

VIDEO HD 1080p30BRI 3 CON 7

MODE CLRHDTVI

[ HD-TVI ]

VIDEO HD 1080i60BRI 3 CON 7

MODE CLRHDSDI

[ HD-SDI image ]

VIDEO HD 1080i60BRI 3 CON 7

MODE CLRHDSDI

[ Zoom in HD-SDI image ]

VIDEO HD 1080p30BRI 3 CON 7

MODE CLRHDTVI

[ HD-TVI image ]

VIDEO HD 1080p30BRI 3 CON 7

MODE CLRHDTVI

[ Zoom in HD-TVI image ]

Press button for 3 sec to select video input mode first than connect video cable to the BNC connector.Video mode will be changed such as HD-SDI, CVBS, HD-TVI as below.

20 MULTI FUNCTIONAL CCTV TESTER 21 MULTI FUNCTIONAL CCTV TESTER

Button for Multimeter mode

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SET

① ② ③

V~ ~♬

① Voltage mode② OHM(resistance) mode③ AC/DC, resistance/ continuity

FUNCTIONSFUNCTIONS

Digital Multimeter

Voltage, resistance and continuity can be tested.

To prevent electric shocks, injury, or damage to the Rapport mini HD, disconnectthe power supply to the circuit under test, and discharge all high-voltage capacitors before testing resistance and continuity.

When using the meter function of the Rapport mini HD, make sure the unit is switched on and set to the appropriate test mode before connecting the test lead set to the circuit under test.

W A R N I N G

Press the button to go into the multi meter mode.

Setup KeysMETER

① METER : Indicates current mode.

② Indicates remained battery.

③ Indicates type of test set up : Resistance, Voltage, Continuity (Buzzer)

④ Indicates test mode : DCV > DC Voltage, ACV > AC Voltage, OHM> Resistance BUZZ> Continuity

Indicates test value displayed : Resistance (Ω, kΩ, MΩ), voltage( V, mV), continuity(BUZZ)⑤

⑦ Indicates measured value on hold : The measure value is stored and displayed here when the SET key is pressed .

⑧ Indicates Store button by using SET button.

⑥ Indicates measured graph value : The Measured Input value is displayed in the form of a graph.The graph is changed automatically and is equal to the measured value.OVER is displayed when the measured value is higher than the setup value.

( : DC Adaptor connected : Operated by Battery)

METERDC ΩAC VOLT

DCV+ 33.4mV

DCV+ 09.5mVMODE STORE

④⑥

②③⑤

※ Sleep time is not operated in Multimeter mode.

0101

METERDC ΩAC VOLT

ACV 0.042V

METERAC ΩDC VOLT

DCV+ 00.1mV

MODE STORE

[ Select Multi Meter Mode ] [ Multi Meter Mode ]

METER PTZ SETUPVIDEO DATA0101

22 MULTI FUNCTIONAL CCTV TESTER 23 MULTI FUNCTIONAL CCTV TESTER

FUNCTIONSFUNCTIONS

Measuring AC & DC Voltage

Voltage is the difference in electrical potential between two points. The polarity of an AC voltage varies with time, while DC polarity is constant. The meter displays AC voltage as RMS values (Root Mean Square readings). The RMS value is the equivalent DC voltage measured in a time varying sinusoidal signal.

[ AC Voltage Test ] [ DC Voltage Test ]

[ AC Voltage Test ] [ DC Voltage Test ]

Measuring ResistanceThe unit of resistance is the Ω. The meter sends a low current into the circuit so that the resistance can be measured. This current runs along all paths between the two test leads and enables the total resistance to be calculated.

Continuity Testing

Continuity means the presence of a complete path for current to flow. The continuity test features a beep that sounds when a circuit is complete. The beep allows users to quickly test continuity without having to watch the display.

METERAC ΩDC VOLT

DCV+ 33.4mV

DCV+ 09.5mVMODE STORE

METERDC ΩAC VOLT

ACV 0.431V

MODE STORE

METERACDC VOLT

OHM 15.4K

MODE STORE

Ω

METERACDC VOLT

BUZZ OVER

MODE STORE

Ω

COM V/

300V 300V~MAX

V~ ~♬

COM V/

300V 300V~MAX

V~ ~♬

COM V/

300V 300V~MAX

V~ ~♬

COM V/

300V 300V~MAX

V~ ~♬

COM V/

300V 300V~MAX

V~ ~♬

24 MULTI FUNCTIONAL CCTV TESTER 25 MULTI FUNCTIONAL CCTV TESTER

PTZ control Button

VIDEO

IN

Tx-

Tx+ VIDEO

Tx- Tx+ Rx- Rx+

[ Select PTZ Control mode]

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SET

FUNCTIONSFUNCTIONS

① VIDEO : Indicates Current Mode.② NTSC : Indicates NTSC or PAL System. (LOSS : No Video, CVBS/HD-SDI/HD-TVI)③ Indicates remained battery. ④ Indicates PTZ Setting→ ADDRESS : Set PTZ address ( 000~255)→ PROTOCOL : Set PTZ protocol (24 Protocols)→ BAUDRATE : Set baudrate ( 2.4Kbps, 4.8Kbps, 9,6Kbps, 19.2Kbps, 38.4Kbps ,57.6Kbps, 115.2Kbps )→ PARITY : Set parity (EVEN, ODD, NONE)→ OK : Returning to the initial screen of PTZ.

( : DC Adaptor connected : Operated by Battery)

PTZ ControllerConnecting Camera and MonitorPTZ Operation Test: Up, Down, Left, Right, Zoom and Manual focus control are possible. The tester can also be set to various protocols and transmission speeds (baud rates).

The PTZ SELECT menu is displayed when the PTZ key is pressed.

PTZ NTSCPTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

SPD15

GPST001

SPST001

FUNC01

MENU

METER PTZ SETUPVIDEO DATA0101

PTZ NTSCPTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

SPD15

GPST001

SPST001

FUNC01

MENU

METER PTZ SETUPVIDEO DATA0101

①④

②③

[PTZ Communication setting]

PTZ NTSC

SPD15

GPST001

SPST001

FUNC01

MENU

MODE OK

PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

26 MULTI FUNCTIONAL CCTV TESTER 27 MULTI FUNCTIONAL CCTV TESTER

SET

SET

SET

SET

PTZ NTSC

PTZ NTSC

MODE GO

MODE GO

SPD15

GPST001

SPST001

FUNC01

MENU

PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

SPD15

GPST001

SPST001

FUNC01

MENU

PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

PTZ NTSC

MODE GO

SPD15

GPST001

SPST001

FUNC01

MENU

PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

PTZ NTSC

SPD15

GPST001

SPST001

FUNC01

MENU

PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

MODE GO

FUNCTIONSFUNCTIONS

How to Control a PTZ Camera

SPD (SPEED) : Move the cursor to the SPD icon, using the procedures described above. A total of 16 increments in speed (0 to 15) are available

for selection using the keys.

GPST (GO TO PRESET) : Moves the camera view to a designated preset location; Presets are numbered 000 to 255. The cursor moves to the GPST position when the key is pressed. Select the previously stored PRESET number using the & keys (move by+1, -1 step). Once selection is complete, press the key once more and the camera will move to the PRESET location.

SPST (SET PRESET) : Sets and stores PRESET information in the range from 000 to 255. First, move the camera to the required view and press the key, and use the & keys to place the cursor at the location of the chosen preset. Then set up the address where the preset is to be stored by using the & keys, and press the key once more. The location information is now stored as a preset address.

FUNC (Function) : User can set different functions that automatically load the presets of the camera system. The FUNC setup uses the SPST and MENU information buttons for the user to program various presets. The different number of presets can range from 00 all the way to 63. The functions (presets) can be programmed by the (+1), (-1) buttons and steps by using the & keys.

ⓐ Change the PTZ setting value

ⓑ Select PTZ setting value

ⓒ Exit the PTZ settings

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SET ⓒ

ⓐⓐ

Pressing the SET button activates the following functions can be selected and use the arrow keys to set the desired function, and can be tested.

28 MULTI FUNCTIONAL CCTV TESTER 29 MULTI FUNCTIONAL CCTV TESTER

PTZ OSD clearENTER button

PTZ NTSC PTZ NTSC

TELEOSD

TELEOSD

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SET

FAROPEN

TELEOSD

NEARCLOSE WIDE

MODE SET

PTZ NTSC

PTZ NTSC

SPD15

GPST001

SPST001

FUNC01

MENU

MODE GO

PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

MODE SETUP

MAIN MENUDOMECAMERAMOTIONDISPLAYCLEAR DATAEXIT

SPD15

GPST001

SPST001

FUNC01

MENU

MODE SHIFT SETUP

PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE

MODE SHIFT SETUP

DATA RCV NTSC

0101

VIDEOTx- Tx+ Rx- Rx+

VIDEO

IN

Rx-

Rx+

Tx-

Tx+

FUNCTIONSFUNCTIONS

MENU : Activates the PTZ camera’s internal menu. PTZ cameras have an on-screen menu system that allows Rapport mini HD to program various functions of the camera including day/night mode, focus settings, and tours. When a tour is programmed into the camera it can be activated with Rapport mini HD using the TOUR function in the menu.

OSD Clear : When you press ENTER button in the PTZ mode, the PTZ OSD clear button is activated and press the button, the PTZ OSD is cleard.

When you want to know the input signal of an exterior controller, you can see the input data(HEX value) by connecting the communications cable to the Rx terminal of the Rapport mini HD. The control commands from the keyboard of an external control are displayed on the screen. Most important is that the communications speed be matched.

METER PTZ SETUPVIDEO DATA0101

DATA

30 MULTI FUNCTIONAL CCTV TESTER 31 MULTI FUNCTIONAL CCTV TESTER

MODE

[ Clear received data ]

DATA RCV

MODE CLEAR

F F 0 0 0 0 F F 0 1 0 0 0 0 F F 0 1 0 0 0 2 3 B 3 B 7 9 F F 0 1 0 0 0 2 3 B 3 B 7 9 F F 0 1 0 0 0 0 0 0 0 0 0 1 F F 0 1 0 0 0 0 0 0 0 0 0 1 F F 0 1 0 0 0 0 0 0 0 0 0 1

DATA RCV

MODE CLEAR

SET

[ SETUP mode ]

SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON

SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON

MODE

① ②

FUNCTIONSFUNCTIONS

① DATA RCV : Indicates Current Mode.② Indicates remained battery. ③ Indicates received data.④ CLEAR : Clear the received data on the screen. (SET button operation)

( : DC Adaptor connected : Operated by Battery)

① SETUP : Indicates Current Mode.② Indicates remained battery. ③ Indicates setup items.

( : DC Adaptor connected : Operated by Battery)

Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys

Mode Select : To access this menu depress the key and select the SETUP icon.

SETUP

METER PTZ SETUPVIDEO DATA0101

DATA RCV

MODE CLEAR

32 MULTI FUNCTIONAL CCTV TESTER 33 MULTI FUNCTIONAL CCTV TESTER

SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON

MODE

SETUP

BACK

USER NAME

RAPPORT - MINI

0 1 2 3 4 5 6 7 8 9 ( ) A B C D E F G H I J K L MN O P Q R S T U V W X Y Z ! @ # $ % & + - + < >

SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON

MODE

SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON

MODE

FUNCTIONS

USER NAME : Selecting the USER NAME initiates an editing menu and shows the associated key strokes.

SLEEP TIME : Select sleep time by using the & buttons and change sleep options by using the & buttons. The options are OFF, 1, 5, 10, 30, 60 minutes.

Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys and( : confirm the selected character, :select to delect character) and press EXIT(SET button) to save the changed USER NAME. The screen is changed to SETUP screen.

BEEP : Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys (ON/OFF)

Number

1

2

3

4

5

6

7

8

9

10

11

12

13

Direct current

Alternating current

3

Symbol Description

Both direct and alternating current

Three-phase alternating current

Earth (ground) TERMINAL

PROTECTIVE CONDUCTOR TERMINAL

Frame or chassis TERMINAL

Equipotentiality

On(Supply)

Off(Supply)

Equipment protected throughoutby DOUBLE INSULATION orREINFORCED INSULATION

Caution, rick of electronic shock

Caution, hot surface

IRE 60417 - 5031

Reference

IRE 60417 - 5032

IRE 60417 - 5033

IRE 60417 - 5017

IRE 60417 - 5019

IRE 60417 - 5020

IRE 60417 - 5021

IRE 60417 - 5007

IRE 60417 - 5008

IRE 60417 - 5172

IRE 60417 - 5041

**The equipment shall not be used for measurements of categories II, III and IV.**If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

SYMBOLS

SYMBOLS

※ Sleep time makes the power go OFF automatically, unless the button is pressed.

TELEOSD

WIDE

34 MULTI FUNCTIONAL CCTV TESTER 35 MULTI FUNCTIONAL CCTV TESTER

MEMOMEMO