multi functional cctv tester - supercircuits · 10 multi functional cctv tester 11 multi functional...
TRANSCRIPT
P/N : 388087345 PRINTED IN KOREA
Rapport mini HDMulti Functional CCTV Tester
FAROPEN
TELEOSD
NEARCLOSE WIDE
COM V/
300V 300V~MAX
V~ ~♬
MODE SET
TABLE OF CONTENTS TABLE OF CONTENTS
BEFORE USING Rapport mini HD
SAFETY INFOMATION
PRODUCT INTRODUCTION
Product Introduction
Part name & Functions
Product Specification
Dimension
LED Indicator
FUNCTIONS
Power ON/OFF
Mode setup
Video Tester
Switch CVBS, HD-SDI and HD-TVI
Digital Multimeter
Measuring AC & DC Voltage
Measuring Resistance
Continuity Testing
PTZ Controller
SPD(SPEED)
GPST(GO TO PRESET)
SPST(SET PRESET)
FUNC
MENU
4
5
6
6
8
12
14
15
16
16
17
18
20
22
24
25
25
26
28
29
29
29
30
DATA
SETUP
USER NAME
SLEEP TIME
BEEP
SYMBOLS
31
33
34
34
34
35
02 MULTI FUNCTIONAL CCTV TESTER 03 MULTI FUNCTIONAL CCTV TESTER
Be sure to read through the "Safety Information" section before using this Rapport mini HD.
GeneralPrecautions
Pay attention to the following precautions when usingthe Rapport mini HD.
BEFORE USING Rapport mini HD
This basic instruction manual is for users of the Rapport mini HD. Starting with an outline of this Rapport mini HD, the manual explains its operation,how it connects to other devices, how to use the menu buttons,and how it should be operated. It is highly recommended, even for those who have handled similar devices, as well as for those using it for the first time, to read all the instructions thoroughly, especially the precautions, before using the Rapport mini HD. If there are any questions which arise when using the Rapport mini HD or the unit is damaged, please contact the supplier of your Rapport mini HD.Safety Information highlights and explains the precautions which should be taken, for the safety of users, when using the Rapport mini HD.
When using the Digital MultiMeter function to measure voltage or current, be sure that the input does not exceed the capabilities of the tester. Overloading the tester can cause damage or personal injury.
When measuring current of unknown values, always begin with the 10A mode, then step down to the 400mA input if necessary.
Environmental Limitations
Temperature: -10 to 50 degrees CRelative Humidity: 30% -90%DC input voltage: 12V +/-10%, 1A
Rapport mini HD Safety Precautions
-Use only specified replacement fuses.-Do not use damaged test leads with the DMM.-When using the DMM function, set the proper mode before connecting to the circuit under est.-When measuring resistance, make certain that the circuit is de-energized before connecting the test leads to the circuit.-Do not measure resistance on powered circuits.-Do not use the unit in damp, humid or gaseous environments.-Do not touch it with wet hands.-Be mindful not to shock or shake the unit while in use to avoid damage.-Avoid areas with strong magnetic or electromotive fields, which can cause incorrect measurements.-Remove the power plug from the outlet when there is a lighting storm. -Neglecting to do so may cause fire or damage to the product.-The Main plug is used as a disconnect device and shall stay readily operable at any time.-Be sure to use only the standard adapter that is specified in the specification sheet.-Using any other adapter could cause fire, electrical shock, or damage to the product.-Securely plug the power cord into the power receptacle. Insecure connection may cause fire.-If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the power source and contact the service center. Continued use in such a condition may cause fire or electric shock.-When cleaning, do not spray water directly onto parts of the product. Doing so may cause fire or electric shock
SAFETY INFORMATION
04 MULTI FUNCTIONAL CCTV TESTER 05 MULTI FUNCTIONAL CCTV TESTER
• Rapport mini HD • Accessories
BNC cablePower Adaptor
Test lead body cover
MANUAL
manual
Rapport mini HD has a built-in Lithium Polymer Battery.
It can be recharged using a DC12V power adapter with an output of 1A or above and reaches its full charge after a period in excess of 5 hours. After the battery has been fully charged for the first 2~3 charging cycles, it can be used for approximately 6 hours (up to a Max.8 hrs in normal operation).The battery can be recharged by connecting it to the DC adapter, regardless of OSD power, when the slider switch has been turned on.
The discharge operation starts when the Main Switch is turned on and it then consumes power from the battery. Therefore, when the Rapport mini HD is not being used for a period of time, make sure the Main Switch is turned off.
PRODUCT INTRODUCTION PRODUCT INTRODUCTION
Summary
Standard ItemsCheck the contents of your Rapport mini HD package against the standard checklist below.
Designed, with portability and serious CCTV engineers in mind, the Rapport mini HD is an advanced piece of video test equipment consisting of many useful test functions needed to professionally install a CCTV system; test functions include Video quality, Service Monitor, Multimeter, PTZ Test, RS-422 and RS-485 Communication Test, etc.
Product Introduction
Test Leads
AdaptorBNC to BNC Cable
MANUAL
• Package
FAROPEN
TELEOSD
NEARCLOSE WIDE
COM V/
300V 300V~MAX
V~ ~♬
MODE SET
FAROPEN
TELEOSD
NEARCLOSE WIDE
COM V/
300V 300V~MAX
V~ ~♬
MODE SET
06 MULTI FUNCTIONAL CCTV TESTER 07 MULTI FUNCTIONAL CCTV TESTER
MODE
SET
FAROPEN
TELEOSD
NEARCLOSE
WIDE
① : Common Port, Lead for black color
② : Voltage & Resistance Port, Lead for red color
PRODUCT INTRODUCTION PRODUCT INTRODUCTION
Part name & Functions
Power LED
Charge LED
Data Transmitting LED
Data Receiving LED
LCD
Keypad
MODE Button
SET Button
PTZ mode
Red LED is on when the system is switched on.
Green LED is on when the battery is fully charghed.
Red LED is on when PTZ data is transmitted.
Green LED is on when PTZ data is received.
2.4” Color TFT LCD
Main keypad for Rapport mini HD operation
Mode Select: Video, MultiMeter, PTZ Control.
Used to confirm selection in menu screens.
(Press for 2 seconds to power on.)
Adjusts PTZ Focus Far Operation.
IRIS OPEN
Part Name Function
①
②
③
④
⑤
⑥
Part Name Function
PTZ mode
PTZ mode
PTZ mode
PTZ mode
Test Lead Connection : Ports for Digital MultiMeter
V/
COM
Adjusts PTZ Focus Near OperationIRIS Close
Adjusts PTZ Focus Zoom-in Operation
Clear OSD of PTZ mode
Adjusts PTZ Focus Zoom-out Operation
PTZ Mode : Moves PTZ Up/Down/Left/& Select Menu -> Enter(Select video mode in mode screen, press button for 3sec to switch HD-SDI, CVBS and HD-TVI)
⑤
⑥
⑦
⑧
① ② ③ ④
FAROPEN
TELEOSD
NEARCLOSE WIDE
COM V/
300V 300V~MAX
V~ ~♬
MODE SET
COM V/
300V 300V~MAX
V ~♬
① ②
08 MULTI FUNCTIONAL CCTV TESTER 09 MULTI FUNCTIONAL CCTV TESTER
①
②
① DC Power Jack : DC Power Input Jack (DC12V, 1A)② Power Switch : Main Power Supply ON/OFF switch
Internal Battery Cover
① Communication Port : Input & Output of PTZ communications signals (RS 422/ RS485, Rx+, Rx-, Tx+, Tx- )
①
PRODUCT INTRODUCTION PRODUCT INTRODUCTION
② Video IN : Select function in video selection mode. Video IN : The input video signal of CVBS(NTSC / PAL), HD-SDI and HD-TVI display to the LCD (Press button for 3 sec to switch video mode.)
① ②
10 MULTI FUNCTIONAL CCTV TESTER 11 MULTI FUNCTIONAL CCTV TESTER
Electrical Specifications
Functional Specifications
Multi-meter Specifications
PRODUCT INTRODUCTION PRODUCT INTRODUCTION
Mode Range MinimumMeasuring
Accuracy
DC Voltage
400mV 100uV
4V 1mV
40V 10mV
300V 100mV
AC Voltage
4V 1mV
40V 10mV
300V 100mV
Resistance
400Ω 0.1Ω
4㏀ 1Ω
40㏀ 10Ω
400㏀ 100Ω
4MΩ 1㏀
40MΩ 10㏀
Continuity Beeper is activated when the resistance is low.
±(2.5% +4dgts)
±(2.5% +4dgts)
±(2.5% +4dgts)
±(2.0% +4dgts)
±(2.0% +2dgts)
±(2.0% +4dgts)
±(3.0% +5dgts)
(40㎐ ~ 500㎐)
Note : Maximum voltage drop approx 2V on the measuring current.
ElectricalCharacteristic
Input Voltage
Battery
Built-in charger
Display
Display Resolution
Working Temp.
Dimension
DC 12V ± 10%, 1A
7.4V (3.7x2)Li-Poly, 2000mAh
Charging Time : 6 hour
Operation Time : 8 hour
2.4" TFT-LCD (Digital), RGB666
320 x 240
-10℃~50℃
L159.3 x W79.1 x T32.2 (mm)
Video Mode
Video IN
LCD Adjustment
CVBS Signal Mode
HD-SDI Format
Communication
PTZ Protocol
Baud rate
Rx Data Analyzer
CVBS, BNC IN, 1.0 Vpp
HD-SDI
HD-TVI
Brightness, contrast
NTSC/PAL (Auto adapt)
720p 50fps / 59.94fps / 60fps
1080i 50fps / 59.94fps / 60fps
1080p 23.98fps / 24fps / 25fps / 29.97fps / 30fps
1080p 50fps / 59.94fps / 60fps
RS422, RS485
Multi (24 protocols)
2400bps~1152000bps
Hex Value Analysis
DC Voltage Range
AC Voltage Range
Continuity
Resistance Range
400mV/4V/40V/300V
4V/ 40V/300V
Built-in Buzzer sound
400Ω/4KΩ/40KΩ /400KΩ/4MΩ/40MΩ
HD-TVI Format
720p 25fps / 30fps
720p 50fps / 60fps
1080p 25fps / 30fps
PTZ Controller
Digital Multi-Meter
12 MULTI FUNCTIONAL CCTV TESTER 13 MULTI FUNCTIONAL CCTV TESTER
Dimension
OFF
OFF
ON
OFF
OFF
ON
OFF
Flicker(1 Hz)
Item RED LED GREEN LED
PRODUCT INTRODUCTION PRODUCT INTRODUCTION
LED Indicator
On charging : RED LED ONFully charged: GREEN LED ON
Shift power switch off to Power on The LED turns Red or Green depend on the recharging status.
Discharged
Charging
Fully charged
Low battery
Battery is consumable item with 6 months warranty after purchase.Use the manufacture provided adaptor only (DC12V/1A).When Red LED flicker, reload battery or recharge battery.
* L159.3 x W79.1 x T32.2 (mm)
TxRx
PWRCHG
159.3
66.5
63.8
79.1
32.2
FAROPEN
TELEOSD
NEARCLOSE WIDE
COM V/
300V 300V~MAX
V~ ~♬
MODE SET
14 MULTI FUNCTIONAL CCTV TESTER 15 MULTI FUNCTIONAL CCTV TESTER
After Operating with Power on- On charging: RED LED ON- Fully charged: GREEN LED ON * When it charge during operating, the screen show like ▶.(▶: DC Adaptor connect and Charge, ◀: Operated by Battery)
MODE
MODEMODE
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SET
[ Mode change ]
• Video Tester (Color CCTV Field Monitor) Video IN : Select input video signal(CVBS, HD-SDI, HD-TVI) - CVBS - HD-SDI - HD-TVI• Digital Multi-meter• PTZ Controller• Receive Data Analyzer• Setup
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SETVIDEO NTSCBRI 3 CON 7
METER PTZ SETUPVIDEO DATA0101
Power ON/OFF
The power switch is located on the side of the handset.Turn the power switch on, and press to start Rapport mini HD.To turn off the system, press & hold for more than 2 sec. Then, POWER OFF is displayed on the main screen with a beep. Release the button. Turn the power switch OFF to prevent battery drain during storage. The switch must remain ON to recharge the batteries.A rechargeable battery should be plugged in over 5 hours to fully charge. The charged battery can operate for about 8 hours.When the battery indicator shows below , recharge it for use. (Full charge: )
FUNCTIONSFUNCTIONS
After the power is applied the above on-screen message is displayed. Approximately 2 seconds later the screen switches to the last OSD before power was turned off. The Rapport mini HD stores the last accessed OSD.The initial OSD message displays the Rapport mini HD's firmware information. Versions of the product change whenever new firmware is uploaded.
Mode setup
Main Functions
The MODE SELECT menu is displayed when the key is depressed and moves to the next menu whenever the key is pressed
The OSD menu changes whenever the key is pressed, and sequences through in the following order :
VIDEO -> Meter -> PTZ controller -> Receive Data -> SETUP ->VIDEO
SET
SET
MODE SET
TxRx
PWRCHG
MODE SET
TxRx
RAPPORT-MINI Ver : X.XX
PWRCHG
HDSDI/CVBS
16 MULTI FUNCTIONAL CCTV TESTER 17 MULTI FUNCTIONAL CCTV TESTER
[ Video Tester mode ]
VIDEO
IN
VIDEO NTSC
[ Video Mode ]
① VIDEO : Indicates Current Mode.② NTSC : Indicates NTSC or PAL System. (LOSS: No video) - CVBS(LOSS : No Video, NTSC, PAL) - HD-SDI(LOSS : No Video, input video information) - HD-TVI(LOSS : No Video, input video information)③ Indicates remained battery. ④ Indicates screen brightness, and brightness increases by +1 when the FAR key is pressed, and decreases by -1 when the NEAR key is pressed.⑤ Indicates screen contrast, and contrast increases by +1 when the TELE key is pressed, and decreases by -1 when the WIDE key is pressed. ⑥ Indicates SET & Indicates OSD clear button⑦ Indicates Mode, and changable by MODE button.⑧ Indicates Current Video
[ OSD clear ]
FUNCTIONSFUNCTIONS
Video Tester
( : DC Adaptor connected : Operated by Battery)
※ If there is no video signal at the VIDEO IN port of the Rapport mini HD “LOSS” will be displayed.
VIDEO NTSCBRI 3 CON 7
MODE CLRCVBS
You can check the CVBS, HD-SDI, HD-TVI video signal and determine the input video type with this video tester function
VIDEO NTSCBRI 3 CON 7
MODE CLRCVBS
①④
⑦ ⑥
②③⑤
⑧
(press button for 3sec to switch HD-SDI, CVBS and HD-TVI)
18 MULTI FUNCTIONAL CCTV TESTER 19 MULTI FUNCTIONAL CCTV TESTER
FUNCTIONSFUNCTIONS
Switch CVBS, HD-SDI and HD-TVI
Select input video
Zoom in image
VIDEO HD 1080i60BRI 3 CON 7
MODE CLRHDSDI
VIDEO NTSCBRI 3 CON 7
MODE CLRCVBS
[ HD-SDI ] [ CVBS ]
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SET
You can move the image by pressing direction keys.
This product support to select the video mode, input video image of CVBS, HD-SDI and HD-TVI. Press button for 3 sec to switch video mode.
Press button to zoom in the HD-SDI and HD-TVI image.
VIDEO HD 1080p30BRI 3 CON 7
MODE CLRHDTVI
[ HD-TVI ]
VIDEO HD 1080i60BRI 3 CON 7
MODE CLRHDSDI
[ HD-SDI image ]
VIDEO HD 1080i60BRI 3 CON 7
MODE CLRHDSDI
[ Zoom in HD-SDI image ]
VIDEO HD 1080p30BRI 3 CON 7
MODE CLRHDTVI
[ HD-TVI image ]
VIDEO HD 1080p30BRI 3 CON 7
MODE CLRHDTVI
[ Zoom in HD-TVI image ]
Press button for 3 sec to select video input mode first than connect video cable to the BNC connector.Video mode will be changed such as HD-SDI, CVBS, HD-TVI as below.
20 MULTI FUNCTIONAL CCTV TESTER 21 MULTI FUNCTIONAL CCTV TESTER
Button for Multimeter mode
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SET
① ② ③
V~ ~♬
① Voltage mode② OHM(resistance) mode③ AC/DC, resistance/ continuity
FUNCTIONSFUNCTIONS
Digital Multimeter
Voltage, resistance and continuity can be tested.
To prevent electric shocks, injury, or damage to the Rapport mini HD, disconnectthe power supply to the circuit under test, and discharge all high-voltage capacitors before testing resistance and continuity.
When using the meter function of the Rapport mini HD, make sure the unit is switched on and set to the appropriate test mode before connecting the test lead set to the circuit under test.
W A R N I N G
Press the button to go into the multi meter mode.
Setup KeysMETER
① METER : Indicates current mode.
② Indicates remained battery.
③ Indicates type of test set up : Resistance, Voltage, Continuity (Buzzer)
④ Indicates test mode : DCV > DC Voltage, ACV > AC Voltage, OHM> Resistance BUZZ> Continuity
Indicates test value displayed : Resistance (Ω, kΩ, MΩ), voltage( V, mV), continuity(BUZZ)⑤
⑦ Indicates measured value on hold : The measure value is stored and displayed here when the SET key is pressed .
⑧ Indicates Store button by using SET button.
⑥ Indicates measured graph value : The Measured Input value is displayed in the form of a graph.The graph is changed automatically and is equal to the measured value.OVER is displayed when the measured value is higher than the setup value.
( : DC Adaptor connected : Operated by Battery)
METERDC ΩAC VOLT
DCV+ 33.4mV
DCV+ 09.5mVMODE STORE
①
④⑥
⑦
②③⑤
⑧
※ Sleep time is not operated in Multimeter mode.
0101
METERDC ΩAC VOLT
ACV 0.042V
METERAC ΩDC VOLT
DCV+ 00.1mV
MODE STORE
[ Select Multi Meter Mode ] [ Multi Meter Mode ]
METER PTZ SETUPVIDEO DATA0101
22 MULTI FUNCTIONAL CCTV TESTER 23 MULTI FUNCTIONAL CCTV TESTER
FUNCTIONSFUNCTIONS
Measuring AC & DC Voltage
Voltage is the difference in electrical potential between two points. The polarity of an AC voltage varies with time, while DC polarity is constant. The meter displays AC voltage as RMS values (Root Mean Square readings). The RMS value is the equivalent DC voltage measured in a time varying sinusoidal signal.
[ AC Voltage Test ] [ DC Voltage Test ]
[ AC Voltage Test ] [ DC Voltage Test ]
Measuring ResistanceThe unit of resistance is the Ω. The meter sends a low current into the circuit so that the resistance can be measured. This current runs along all paths between the two test leads and enables the total resistance to be calculated.
Continuity Testing
Continuity means the presence of a complete path for current to flow. The continuity test features a beep that sounds when a circuit is complete. The beep allows users to quickly test continuity without having to watch the display.
METERAC ΩDC VOLT
DCV+ 33.4mV
DCV+ 09.5mVMODE STORE
METERDC ΩAC VOLT
ACV 0.431V
MODE STORE
METERACDC VOLT
OHM 15.4K
MODE STORE
Ω
METERACDC VOLT
BUZZ OVER
MODE STORE
Ω
COM V/
300V 300V~MAX
V~ ~♬
COM V/
300V 300V~MAX
V~ ~♬
COM V/
300V 300V~MAX
V~ ~♬
COM V/
300V 300V~MAX
V~ ~♬
COM V/
300V 300V~MAX
V~ ~♬
24 MULTI FUNCTIONAL CCTV TESTER 25 MULTI FUNCTIONAL CCTV TESTER
PTZ control Button
VIDEO
IN
Tx-
Tx+ VIDEO
Tx- Tx+ Rx- Rx+
[ Select PTZ Control mode]
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SET
FUNCTIONSFUNCTIONS
① VIDEO : Indicates Current Mode.② NTSC : Indicates NTSC or PAL System. (LOSS : No Video, CVBS/HD-SDI/HD-TVI)③ Indicates remained battery. ④ Indicates PTZ Setting→ ADDRESS : Set PTZ address ( 000~255)→ PROTOCOL : Set PTZ protocol (24 Protocols)→ BAUDRATE : Set baudrate ( 2.4Kbps, 4.8Kbps, 9,6Kbps, 19.2Kbps, 38.4Kbps ,57.6Kbps, 115.2Kbps )→ PARITY : Set parity (EVEN, ODD, NONE)→ OK : Returning to the initial screen of PTZ.
( : DC Adaptor connected : Operated by Battery)
PTZ ControllerConnecting Camera and MonitorPTZ Operation Test: Up, Down, Left, Right, Zoom and Manual focus control are possible. The tester can also be set to various protocols and transmission speeds (baud rates).
The PTZ SELECT menu is displayed when the PTZ key is pressed.
PTZ NTSCPTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
SPD15
GPST001
SPST001
FUNC01
MENU
METER PTZ SETUPVIDEO DATA0101
PTZ NTSCPTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
SPD15
GPST001
SPST001
FUNC01
MENU
METER PTZ SETUPVIDEO DATA0101
①④
②③
⑤
[PTZ Communication setting]
PTZ NTSC
SPD15
GPST001
SPST001
FUNC01
MENU
MODE OK
PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
26 MULTI FUNCTIONAL CCTV TESTER 27 MULTI FUNCTIONAL CCTV TESTER
SET
SET
SET
SET
PTZ NTSC
PTZ NTSC
MODE GO
MODE GO
SPD15
GPST001
SPST001
FUNC01
MENU
PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
SPD15
GPST001
SPST001
FUNC01
MENU
PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
PTZ NTSC
MODE GO
SPD15
GPST001
SPST001
FUNC01
MENU
PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
PTZ NTSC
SPD15
GPST001
SPST001
FUNC01
MENU
PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
MODE GO
FUNCTIONSFUNCTIONS
How to Control a PTZ Camera
SPD (SPEED) : Move the cursor to the SPD icon, using the procedures described above. A total of 16 increments in speed (0 to 15) are available
for selection using the keys.
GPST (GO TO PRESET) : Moves the camera view to a designated preset location; Presets are numbered 000 to 255. The cursor moves to the GPST position when the key is pressed. Select the previously stored PRESET number using the & keys (move by+1, -1 step). Once selection is complete, press the key once more and the camera will move to the PRESET location.
SPST (SET PRESET) : Sets and stores PRESET information in the range from 000 to 255. First, move the camera to the required view and press the key, and use the & keys to place the cursor at the location of the chosen preset. Then set up the address where the preset is to be stored by using the & keys, and press the key once more. The location information is now stored as a preset address.
FUNC (Function) : User can set different functions that automatically load the presets of the camera system. The FUNC setup uses the SPST and MENU information buttons for the user to program various presets. The different number of presets can range from 00 all the way to 63. The functions (presets) can be programmed by the (+1), (-1) buttons and steps by using the & keys.
ⓐ Change the PTZ setting value
ⓑ Select PTZ setting value
ⓒ Exit the PTZ settings
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SET ⓒ
ⓐⓐ
ⓑ
ⓑ
Pressing the SET button activates the following functions can be selected and use the arrow keys to set the desired function, and can be tested.
28 MULTI FUNCTIONAL CCTV TESTER 29 MULTI FUNCTIONAL CCTV TESTER
PTZ OSD clearENTER button
PTZ NTSC PTZ NTSC
TELEOSD
TELEOSD
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SET
FAROPEN
TELEOSD
NEARCLOSE WIDE
MODE SET
PTZ NTSC
PTZ NTSC
SPD15
GPST001
SPST001
FUNC01
MENU
MODE GO
PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
MODE SETUP
MAIN MENUDOMECAMERAMOTIONDISPLAYCLEAR DATAEXIT
SPD15
GPST001
SPST001
FUNC01
MENU
MODE SHIFT SETUP
PTZ ADDR :001PROTOCOL : (01)PELCO-DBAUDRATE: 2 . 4KbpsPARITY : NONE
MODE SHIFT SETUP
DATA RCV NTSC
0101
VIDEOTx- Tx+ Rx- Rx+
VIDEO
IN
Rx-
Rx+
Tx-
Tx+
FUNCTIONSFUNCTIONS
MENU : Activates the PTZ camera’s internal menu. PTZ cameras have an on-screen menu system that allows Rapport mini HD to program various functions of the camera including day/night mode, focus settings, and tours. When a tour is programmed into the camera it can be activated with Rapport mini HD using the TOUR function in the menu.
OSD Clear : When you press ENTER button in the PTZ mode, the PTZ OSD clear button is activated and press the button, the PTZ OSD is cleard.
When you want to know the input signal of an exterior controller, you can see the input data(HEX value) by connecting the communications cable to the Rx terminal of the Rapport mini HD. The control commands from the keyboard of an external control are displayed on the screen. Most important is that the communications speed be matched.
METER PTZ SETUPVIDEO DATA0101
DATA
30 MULTI FUNCTIONAL CCTV TESTER 31 MULTI FUNCTIONAL CCTV TESTER
MODE
[ Clear received data ]
DATA RCV
MODE CLEAR
F F 0 0 0 0 F F 0 1 0 0 0 0 F F 0 1 0 0 0 2 3 B 3 B 7 9 F F 0 1 0 0 0 2 3 B 3 B 7 9 F F 0 1 0 0 0 0 0 0 0 0 0 1 F F 0 1 0 0 0 0 0 0 0 0 0 1 F F 0 1 0 0 0 0 0 0 0 0 0 1
DATA RCV
MODE CLEAR
SET
[ SETUP mode ]
SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON
SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON
MODE
① ②
③
FUNCTIONSFUNCTIONS
① DATA RCV : Indicates Current Mode.② Indicates remained battery. ③ Indicates received data.④ CLEAR : Clear the received data on the screen. (SET button operation)
( : DC Adaptor connected : Operated by Battery)
① SETUP : Indicates Current Mode.② Indicates remained battery. ③ Indicates setup items.
( : DC Adaptor connected : Operated by Battery)
Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys
Mode Select : To access this menu depress the key and select the SETUP icon.
SETUP
METER PTZ SETUPVIDEO DATA0101
DATA RCV
MODE CLEAR
①
③
④
②
32 MULTI FUNCTIONAL CCTV TESTER 33 MULTI FUNCTIONAL CCTV TESTER
SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON
MODE
SETUP
BACK
USER NAME
RAPPORT - MINI
0 1 2 3 4 5 6 7 8 9 ( ) A B C D E F G H I J K L MN O P Q R S T U V W X Y Z ! @ # $ % & + - + < >
SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON
MODE
SETUPUSER NAME : RAPPORT - MINISLEEP TIME : 30MinBEEP : ON
MODE
FUNCTIONS
USER NAME : Selecting the USER NAME initiates an editing menu and shows the associated key strokes.
SLEEP TIME : Select sleep time by using the & buttons and change sleep options by using the & buttons. The options are OFF, 1, 5, 10, 30, 60 minutes.
Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys and( : confirm the selected character, :select to delect character) and press EXIT(SET button) to save the changed USER NAME. The screen is changed to SETUP screen.
BEEP : Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys (ON/OFF)
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
Direct current
Alternating current
3
Symbol Description
Both direct and alternating current
Three-phase alternating current
Earth (ground) TERMINAL
PROTECTIVE CONDUCTOR TERMINAL
Frame or chassis TERMINAL
Equipotentiality
On(Supply)
Off(Supply)
Equipment protected throughoutby DOUBLE INSULATION orREINFORCED INSULATION
Caution, rick of electronic shock
Caution, hot surface
IRE 60417 - 5031
Reference
IRE 60417 - 5032
IRE 60417 - 5033
IRE 60417 - 5017
IRE 60417 - 5019
IRE 60417 - 5020
IRE 60417 - 5021
IRE 60417 - 5007
IRE 60417 - 5008
IRE 60417 - 5172
IRE 60417 - 5041
**The equipment shall not be used for measurements of categories II, III and IV.**If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
SYMBOLS
SYMBOLS
※ Sleep time makes the power go OFF automatically, unless the button is pressed.
TELEOSD
WIDE
34 MULTI FUNCTIONAL CCTV TESTER 35 MULTI FUNCTIONAL CCTV TESTER