mtw.pdf · ercp-catheter, reusable all ercp-catheters with mandrin, and nozzle for injection of...
TRANSCRIPT
![Page 1: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/1.jpg)
![Page 2: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/2.jpg)
Papillotomes
ERCP-catheters
Endoprostheses &PTC-needles
Bronchoscope-instruments
Accessories
Sclerosing-needles &Needles forfibrinadhesive-injection
Cytology- andCleaning-brushes
Foreign-bodyremoving forceps
Polypectomy snares
Lithotomy baskets &stone-extraction-balloonsLithotriptors
1
2
3
4
5
6
7
8
9
11
10
Guide wires 12
Postbox 14 01 18 • D-46476 WeselGoldsbergstraße 18 • D-46487 WeselPhone +49 28 03/91 20-0Fax +49 28 03/81 13
www.mtw-endoskopie.dee-mail: [email protected]
Biopsy-forcepsRectoscopy-forceps &shaft
For all products specified in this catalogwe reserve ourselves technical changesand picture deviations.
![Page 3: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/3.jpg)
2
134 0C
Instruments showing this symbol are autoclavable: 5 minutes with 134°C (273°F), 2 bar or20 minutes with 121°C (246°F), 1 bar
Instruments showing this symbol can be sterilized via ETOgas sterilisation or similar (they cannot be autoclaved).
Instruments showing this symbol are disposable productsto be used one time only.
Polypectomy snares showing this symbol do have an isolated distal tip.
Polypectomy snares showing this symbol are rotatable.
0.035
0.025
Papillotomes showing this symbol align themselves after11 o’clock.
Instruments showing this symbol are suitable for 0.035 inch guide wires.
Instruments showing this symbol are suitable for 0.018 inch guidewires.
Instruments showing these symbols are multi lumen.
Instruments showing this symbol do have a nozzle on the side to wash-out.
Instruments showing this symbol are suitable for 0.025 inch guide wires.
0.018
Reference symbols
Papillotomes showing this symbol align themselves after12 o’clock.
Instruments showing this symbol are radiopaque.
![Page 4: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/4.jpg)
ERCP-catheters
Endoscopic instrumentsand accessories
1
![Page 5: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/5.jpg)
1
Aus
gabe
2-0
4.04
nozzle for injection ofcontrast medium
Article-no.
ERCP-catheter, reusable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
ERCP-catheter, standard
Length (cm)
Guidewire (inch)
ERCP-catheter, filiform Length (cm)
Guidewire (inch)
Article-no.
01 20 10 0 1,6 215 0.025
01 20 10 1 2,3 > 1,6 215 0.025
01 30 10 0 1,8 215 0.035
01 30 10 1 2,3 > 1,8 215 0.035
01 30 90 0 2,3 215 0.035
01 20 20 0 1,6 215 0.025
01 20 20 1 2,3 > 1,6 215 0.025
01 30 20 0 1,8 215 0.035
01 30 20 1 2,3 > 1,8 215 0.035
01 31 00 0 2,3 215 0.035
Description
Description
0.025 0.035
for 0.025 inchguide wire
for 0.035 inchguide wire
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
Diameter (mm)
Diameter (mm)
![Page 6: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/6.jpg)
2
ERCP-catheter, reusable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
ERCP-catheter, conical tip
Description Length (cm)
Guide wire(inch)
ERCP-catheter, filiform, radiopaque, with metal ring inside
Length (cm)
Guide wire(inch)
Description
Article-no.
Article-no.
nozzle for injection ofcontrast medium
01 20 70 0 1,6 215 0.025
01 20 70 1 2,3 > 1,6 215 0.025
01 30 70 0 1,8 215 0.035
01 30 70 1 2,3 > 1,8 215 0.035
01 20 21 0 1,6 215 0.025
01 20 21 1 2,3 > 1,6 215 0.025
01 30 21 0 1,8 215 0.035
01 30 21 1 2,3 > 1,8 215 0.035
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
Diameter (mm)
Diameter (mm)
0.035
for 0.035 inchguide wire
0.025
for 0.025 inchguide wire
![Page 7: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/7.jpg)
3
Aus
gabe
2-0
4.04
ERCP-catheter, reusable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
ERCP-catheter, standard, radiopaque, with metal ring inside
Length (cm)
Guide wire(inch)
Description
nozzle for injection ofcontrast medium
Article-no.
ERCP-catheter with thin metal cannula
01 01 11 0 1,6 215 — Ø cannula = 0,7
Description Length (cm)
Guide wire(inch)
Article-no.
0.025 0.035
for 0.025 inchguide wire
for 0.035 inchguide wire
Ø 0,7
3
01 20 11 0 1,6 215 0.025
01 21 11 0 2,3 > 1,6 215 0.025
01 30 11 0 1,8 215 0.035
01 31 11 0 2,3 > 1,8 215 0.035
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
Diameter (mm)
Diameter (mm)
![Page 8: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/8.jpg)
![Page 9: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/9.jpg)
5
Aus
gabe
2-0
4.04
ERCP-catheter, reusable
ERCP-catheter, with round metal tip
Length (cm)
Guide wire(inch)
DescriptionArticle-no.
01 20 31 0 1,6 215 0.025
01 20 31 1 2,3 > 1,6 215 0.025
01 30 31 0 1,8 215 0.035
01 30 31 1 2,3 > 1,8 215 0.035
0.035
for 0.035 inchguide wire
nozzle for injection ofcontrast medium
0.025
for 0.025 inchguide wire
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
Diameter (mm)
x
5
Article-no. X Diameter (mm) (mm)
ERCP-catheter with thin metal cannula
DescriptionLength(cm)
Guide wire(inch)
01 01 02 0 1,0 2,3 > 1,6 215 0.018
01 02 02 0 1,3 2,3 > 1,6 215 0.025
01 03 02 0 1,6 2,3 > 1,8 215 0.035
guide wire arrestable withintegrated mandrin
0.018
for 0.018 inchguide wire
![Page 10: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/10.jpg)
6
ERCP-catheter, reusable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
ERCP-catheter, with bottle-top shaped metal tip
Length (cm)
Guide wire(inch)
Article-no.
01 20 51 0 1,6 215 0.025
01 20 51 1 2,3 > 1,6 215 0.025
01 30 51 0 1,8 215 0.035
01 30 51 1 2,3 > 1,8 215 0.035
Description
nozzle for injection ofcontrast medium
0.025
for 0.025 inchguide wire
guide wire arrestablewith integrated mandrin
guide wire arrestablewith integrated mandrin
Diameter (mm)
ERCP-catheter, with filiform metal tip
Length (cm)
Guide wire(inch)
DescriptionArticle-no.
01 20 41 0 1,6 215 0.025
01 20 41 1 2,3 > 1,6 215 0.025
01 30 41 0 1,8 215 0.035
01 30 41 1 2,3 > 1,8 215 0.035
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
Diameter (mm)
0.035
for 0.035 inchguide wire
![Page 11: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/11.jpg)
7
Aus
gabe
2-0
4.04
ERCP-catheter, reusable
ERCP-catheter, multi lumen, radiopaque tip
0.035
for 0.035 inchguide wire
nozzle for injection ofcontrast medium
Description Length (cm)
Guide wire(inch)
Article-no.
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
01 30 12 1 2,3 > 1,8 215 0.035
01 30 42 1 2,5 > 2,0 215 0.035
Length (cm)
Guide wire(inch)
ERCP-catheter, with conical metal tip
Article-no.
01 20 61 0 1,6 215 0.025
01 20 61 1 2,3 > 1,6 215 0.025
01 30 61 0 1,8 215 0.035
01 30 61 1 2,3 > 1,8 215 0.035
Description
0.025
for 0.025 inchguide wire
guide wire arrestablewith integrated mandrin
guide wire arrestablewith integrated mandrin
guide wire arrestablewith integrated mandrin
guide wire arrestablewith integrated mandrin
Diameter (mm)
Diameter (mm)
![Page 12: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/12.jpg)
8
Wash-out- & spraycatheter, reusable
Description Length (cm)
Spraycatheter
11 01 01 21 0 1,8 120
11 01 01 31 0 2,3 120
01 01 21 4 1,8 160
01 01 31 4 2,3 160
01 01 21 5 1,8 180
01 01 31 5 2,3 180
01 01 21 0 1,8 230
01 01 31 0 2,3 230
Article-no.
Wash-out catheter, round metal tip
Length (cm)
Description
01 31 21 0 2,3 215
Article-no.
nozzle for injection ofcontrast medium
Diameter (mm)
Diameter (mm)
for spraying on marking fluidfor a better distinguishing ofpathological structures
![Page 13: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/13.jpg)
9
Aus
gabe
2-0
4.04
0.035
for 0.035 inchguide wire
ERCP-catheter, disposable
ERCP-catheter, standard
DescriptionGuide wire(inch)
99 01 30 10 0 1,8 215 0.035
ERCP-catheter, filiform
Length (cm)
Guide wire(inch)
Description
nozzle for injection ofcontrast medium
All disposable ERCP-catheters are delivered in packaging units.
Length (cm)
Article-no.
Article-no.
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
99 01 30 20 0 1,8 215 0.035
2
Diameter (mm)
Diameter (mm)
Packagingunit: 5 pieces
Packagingunit: 5 pieces
![Page 14: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/14.jpg)
10
ERCP-catheter, disposable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
ERCP-catheter, standard
ERCP-catheter, filiform
Length(cm)
Guide wire(inch)
Description
2
All disposable ERCP-catheters are delivered in packaging units.
Article-no.
Length(cm)
Guide wire(inch)
Description
99 01 30 10 3 2,3 > 1,8 215 0.035
Article-no.
99 01 30 20 3 2,3 > 1,8 215 0.035
nozzle for injection ofcontrast medium
0.035
for 0.035 inchguide wire
DISPOSABLE
arrestable
Diameter (mm)
Diameter (mm)
guide wire arrestable
Packagingunit: 5 pieces
guide wire arrestable
Packagingunit: 5 pieces
To be used with lying guide wire, arrestable
![Page 15: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/15.jpg)
11
Aus
gabe
2-0
4.04
ERCP-catheter, disposable
ERCP-catheter, standard
DescriptionGuide wire(inch)
99 01 30 10 1 2,3 > 1,8 215
ERCP-catheter, filiform
Length(cm)
Guide wire(inch)
Description
All disposable ERCP-catheters are delivered in packaging units.
To be used with lying guide wire, arrestable
Length(cm)
Article-no.
Article-no.
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
99 01 30 20 1 2,3 > 1,8 215
2
Diameter (mm)
Diameter (mm)
guide wire arrestable withintegrated mandrin
Packagingunit: 5 pieces
guide wire arrestable withintegrated mandrin
Packagingunit: 5 pieces
0.035
for 0.035 inchguide wire
nozzle for injection ofcontrast medium
0.025
for 0.025 inchguide wire
guide wire
arrestable
![Page 16: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/16.jpg)
12
ERCP-catheter, disposable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
DescriptionLength (cm)
Guide wire(inch)
ERCP-catheter, round metal tip
99 01 30 31 0 1,8 215 0.035
ERCP-catheter, bottle-top shaped metal tip
Description Length (cm)
Guide wire(inch)
2
All disposable ERCP-catheters are delivered in packaging units.
99 01 20 51 0 1,6 215 0.025
99 01 30 51 0 1,8 215 0.035
Article-no.
Article-no.
0.035
for 0.035 inchguide wire
nozzle for injection ofcontrast medium
Diameter (mm)
Diameter (mm)
Packagingunit: 5 pieces
Packagingunit: 5 piecesPackagingunit: 5 pieces
Packagingunit: 5 pieces
![Page 17: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/17.jpg)
13
Aus
gabe
2-0
4.04
ERCP-catheter, disposable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
DescriptionLength(cm)
Guide wire(inch)
ERCP-catheter, round metal tip
99 01 30 31 3 2,3 > 1,8 215 0.035
ERCP-catheter, bottle-top shaped metal tip
Description Length (cm)
Guide wire(inch)
2
All disposable ERCP-catheters are delivered in packaging units.
To be used with lying guide wire, arrestable
99 01 30 51 3 2,3 > 1,8 215 0.035
Article-no.
Article-no.
0.035
for 0.035 inchguide wire
nozzle for injection ofcontrast medium
guide wire arrestable
DISPOSABLE
arrestable
Diameter (mm)
Diameter (mm)
Packaging unit:5 pieces
guide wire arrestable
Packaging unit:5 pieces
![Page 18: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/18.jpg)
14
ERCP-catheter, disposable
All ERCP-catheters with mandrin,and nozzle for injection of contrast mediumsuitable for guide wire
DescriptionLength(cm)
Guide wire(inch)
ERCP-catheter, round metal tip
99 01 30 31 1 2,3 > 1,8 215
ERCP-catheter, bottle-top shaped metal tip
DescriptionLength(cm)
Guide wire(inch)
2
All disposable ERCP-catheters are delivered in packaging units.
To be used with lying guide wire, arrestable
99 01 30 51 1 2,3 > 1,8 215
Article-no.
Article-no.
for 0.035 inchguide wire
Diameter(mm)
Diameter(mm)
for 0.025 inchguide wire
0.025 0.035
nozzle for injection ofcontrast medium
guide wire
arrestable
guide wire arrestable withintegrated mandrin
guide wire arrestable withintegrated mandrin
Packaging unit:5 pieces
Packaging unit:5 pieces
![Page 19: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/19.jpg)
Papillotomes
Endoscopic instrumentsand accessories
2
![Page 20: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/20.jpg)
1
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Papillotomes, reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Precut-papillotome
DescriptionLength(cm)
Guide wire(inch)
Papillotome, standard, 5 mm tip
Article-no. X Diameter (mm) (mm)
02 50 31 15 1,6 215 —
02 60 31 20 1,6 215 —
02 00 31 30 1,6 215 —
x
5
x
Guide wire(inch)
Description
Handle with nozzle for injectionof contrast medium
02 50 11 15 1,6 215 —
02 00 11 20 1,6 215 —
02 00 21 30 1,6 215 —
Length(cm)
Stopper for handle:see chapter 10,page 9
![Page 21: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/21.jpg)
2
Article-no. X Diameter (mm) (mm)
Papillotomes, filiform, reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Papillotome, filiform
DescriptionGuide wire(inch)
02 00 53 15 1,6 215 —
02 00 54 20 1,6 215 —
02 00 51 30 1,6 215 —
02 00 71 30 1,6 215 —
Papillotome, filiform
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
02 05 51 30 1,6 215 —
Description
7
xx
Handle with nozzle for injectionof contrast medium
radiopaque tip,type "a"
strengthened and
radiopaque tip
for Papilla Minor,with cutting metaltip, type "b“
2,5
x
„a“
„b“
Length(cm)
Length(cm)
Stopper for handle:see chapter 10,page 9
![Page 22: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/22.jpg)
3
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Papillotomes, reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Papillotome, filiform
Handle with nozzle for injectionof contrast medium
DescriptionGuide wire(inch)
02 45 51 30 1,6 215 —
Papillotome
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
02 00 61 30 1,6 215 —
Description
15
x
with metal tipand guiding tip,siliconstrengthened
7
x
strengthenedwithflat feather
Length(cm)
Length(cm)
Stopper for handle:see chapter 10,page 9
![Page 23: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/23.jpg)
![Page 24: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/24.jpg)
5
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Papillotomes, cutting direction "left", reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
Papillotome, filiform, flat feather, for guide wire
DescriptionGuide wire(inch)
Papillotome with metal tip, flat feather
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
Description
7
x
15
x
Handle with nozzle for injectionof contrast medium
Handle with nozzle for injectionof contrast medium. To be used with lying guide wire.
02 40 51 30 1,6 215 —
02 37 51 30 2,3 > 1,8 215 0.035
with flatfeatherwith flatfeather
02 40 61 30 1,6 215 — with guiding tip,metal tip and flatfeather, rotated
0.035
for guide wire0.035 inch
Length(cm)
Length(cm)
Fitting guide wires: see chapter 12!
Stopper for handle:see chapter 10,page 9
![Page 25: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/25.jpg)
6
Article-no. X Diameter (mm) (mm)
Papillotomes, reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Combined papillotome, needle retractable
DescriptionGuide wire(inch)
02 01 01 30 1,6 215 — strengthened
Knife-papillotome
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
02 01 31 10 1,6 215 —
Description
x
10
Handle with nozzle for injectionof contrast medium
x
Length(cm)
Length(cm)
Stopper for handle:see chapter 10,page 9
![Page 26: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/26.jpg)
7
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Needle-papillotomes, reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Needle-papillotome, Iso-Tome
DescriptionGuide wire(inch)
02 01 21 6 1,6 215 —
Needle-papillotome, injection through the cannula
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
02 01 11 6 2,3 215 —
Description Ø 1
Handle with nozzle for injectionof contrast medium
x
x
Length(cm)
Lenght(cm)
Stopper for handle:see chapter 10,page 9
![Page 27: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/27.jpg)
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Papillotomes B-II-stomach, reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
Papillotome B-II-stomach
DescriptionGuide wire(inch)
02 01 51 20 1,8 215 —
02 01 61 20 2,3 215 —
02 01 71 20 2,3 215 —
only rotatable incombination with theuniversal handle 10 30 0
Papillotome B-II-stomach, for guide wire
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
Description
x
x
0.025 0.035
for guide wire0.025 inch
for guide wire0.035 inch
02 21 61 20 2,3 215 0.025
02 31 61 20 2,3 215 0.035
rotatable
Length(cm)
Length(cm)
Fitting guide wires: see chapter 12!
Handle with nozzle for injection of contrast medium.To be used with lying guide wire.
Stopper forhandle: seechapter 10,page 9
![Page 28: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/28.jpg)
Article-no. X Diameter (mm) (mm)
Papillotomes for guide wire, reusable
These papillotomes have a pre-assembled handle,are radiopaque and autoclavable.
Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
Precut-papillotome
DescriptionGuide wire(inch)
Papillotome, standard, 5 mm guiding tip
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
Description
0.0250.035
for guide wire0.025 inch
for guide wire0.035 inch
02 20 11 20 2,3 > 1,6 215 0.025
02 30 11 20 2,3 > 1,8 215 0.035
02 20 21 30 2,3 > 1,6 215 0.025
02 30 21 30 2,3 > 1,8 215 0.035
02 20 33 15 2,3 > 1,6 215 0.025
02 30 33 15 2,3 > 1,8 215 0.035
02 20 34 20 2,3 > 1,6 215 0.025
02 30 34 20 2,3 > 1,8 215 0.035
02 20 31 30 2,3 > 1,6 215 0.025
02 30 31 30 2,3 > 1,8 215 0.035
Length(cm)
Length(cm)
Fitting guide wires: see chapter 12!
x5
x
Handle with nozzle for injection of contrast medium.To be used with lying guide wire.
Stopper forhandle: seechapter 10,page 9
![Page 29: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/29.jpg)
1
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Papillotomes for guide wire, reusable
These papillotomes have a pre-assmebled handle,are radiopaque, autoclavable and can be introduced with a guide wire.Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
0.025 0.035
for guide wire0.025 inch
for guide wire0.035 inch
Papillotome, filiform
DescriptionGuide wire(inch)
Papillotome with metal tip
7
X
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
Description
15
x
Handle with nozzle for injection of contrast medium.To be used with lying guide wire.
02 20 53 15 2,3 > 1,6 215 0.025
02 30 53 15 2,3 > 1,8 215 0.035
02 20 54 20 2,3 > 1,6 215 0.025
02 36 51 20 2,3 > 1,8 215 0.035
02 20 51 30 2,3 > 1,6 215 0.025
02 30 51 30 2,3 > 1,8 215 0.035
02 20 61 30 2,3 > 1,6 215 0.025
02 30 61 30 2,3 > 1,8 215 0.035
Length(cm)
Length(cm)
Fitting guide wires: see chapter 12!
Stopper forhandle: seechapter 10,page 9
![Page 30: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/30.jpg)
![Page 31: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/31.jpg)
Article-no. X Diameter (mm) (mm)
Papillotomes for guide wires, reusable
These papillotomes have a pre-assembled handle,are radiopaque, autoclavable and can be introduced with a guide wire.Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
Precut-papillotome, multi lumen
DescriptionGuide wire(inch)
02 32 71 20 2,3 > 1,8 215 0.035
02 34 71 20 2,5 > 2,0 215 0.035
Papillotome, standard, multi lumen
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
02 32 61 20 2,3 > 1,8 215 0.035
02 32 41 30 2,3 > 1,8 215 0.035
02 34 61 20 2,5 > 2,0 215 0.035
02 34 41 30 2,5 > 2,0 215 0.035
Description
0.035
for guide wire0.035 inch
Handle with nozzle for injection of contrast medium.To be used with lying guide wire.
multi-lumen
Length(cm)
Length(cm)
Fitting guide wires: see chapter12!
x5
x
Stopper forhandle: seechapter 10,page 9
![Page 32: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/32.jpg)
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Papillotomes, disposable
These papillotomes have a pre-assembled handleand are radiopaque.
Precut-papillotome
Guide wire(inch)
99 02 00 11 20 1,6 215 —
Papillotome, filiform
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
99 02 00 51 30 1,6 215 —
Description
2
X
All disposable papillotomes are delivered in packaging units.
7
X
Description
Handle with nozzle for injection of contrastmedium
SPOSABLE
Length(cm)
Length(cm)
Packaging unit:5 pieces
Packaging unit:5 pieces
Stopper forhandle: seechapter 10,page 9
![Page 33: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/33.jpg)
Article-no. X Diameter (mm) (mm)
Papillotomes, disposable
These papillotomes have a pre-assembled handleand are radiopaque.
Needle-papillotome
DescriptionGuide wire(inch)
99 02 01 21 — 1,6 215 —
Length(cm)
All disposable papillotomes are delivered in packaging units.
Packaging unit:5 pieces
2
6
Handle with nozzle for injection of contrastmedium
SPOSABLE
Stopper for handle:see chapter 10,page 9
![Page 34: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/34.jpg)
Aus
gabe
2-0
4.04
Article-no. X Diameter (mm) (mm)
Papillotomes for guide wire, disposable
These papillotomes have a pre-assembled handle, are radiopaque,and can be introduced with a guide wire
Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
Precut-papillotome
DescriptionGuide wire( inch)
99 02 30 11 20 2,3 > 1,8 215 0.035
Papillotome, standard
Guide wire(inch)
99 02 30 31 30 2,3 > 1,8 215 0.035
Description
All disposable papillotomes are delivered in packaging units.
0.035
for guide wire0.035 inch
DISPOSABLE
Length(cm)
Article-no. X Diameter (mm) (mm)
Length(cm)
Fitting guide wires: see chapter 12!
Packaging unit:5 pieces
Packaging unit:5 pieces
2x
5
x
Stopper for handle:see chapter 10,page 9
![Page 35: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/35.jpg)
1
Papillotomes for guide wire, disposable
These papillotomes have a pre-assembled handle, radiopaqueand can be introduced with a guide wire
Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
Papillotome, filiform
DescriptionGuide wire(inch)
99 02 30 51 30 2,3 > 1,8 215 0.035
99 02 36 51 20 2,3 > 1,8 215 0.035
2
All disposable papillotomes are delivered in packaging units.
7
x
0.035
for guide wire0.035 inch
DISPOSABLE
Length(cm)
Article-no. X Diameter (mm) (mm)
Fitting guide wires: see chapter 12!
Packaging unit:5 piecesPackaging unit:5 pieces
Stopper for handle:see chapter 10,page 9
![Page 36: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/36.jpg)
1
Aus
gabe
2-0
4.04
Papillotomes "Hyperline", disposable
Article-no. X Diameter (mm) (mm)
These papillotomes have a pre-assembled handle,are two-lumen and are appropiate for guide wire.
Attention: All papillotomes for guide wires are only usablewith insulated guide wires!
Papillotome, standard, multi lumen
DescriptionGuide wire(inch)
Precut-papillotome, multi lumen
Article-no. X Diameter (mm) (mm)
Guide wire(inch)
99 02 32 61 20 2,3 > 1,8 215 0.035
99 02 32 41 30 2,3 > 1,8 215 0.035
99 02 34 61 20 2,5 > 2,0 215 0.035
99 02 34 41 30 2,5 > 2,0 215 0.035
Description
2
5
20
Handle with nozzle for injection of contrast medium.To be used with lying guide wire.
Length(cm)
Length(cm)
Fitting guide wires: see chapter 12!
Packaging unit:5 pieces
Packaging unit:5 pieces
Packaging unit:5 pieces
0.035
für Führungsdraht0.035 inch
Stopper forhandle: seechapter 10,page 9
multi-lumen
Packaging unit:5 pieces
99 02 32 71 20 2,3 > 1,8 215 0.035
99 02 34 71 20 2,5 > 2,0 215 0.035
![Page 37: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/37.jpg)
Lithotomy baskets& stone-extraction-
balloonsLithotriptors
Endoscopic instrumentsand accessories
3
![Page 38: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/38.jpg)
1
Aus
gabe
2-0
4.04
Symbol key of chapter 3
Lithotomy baskets characterizedwith this symbol, are suitable forlithotripsy
Products with this symbol enablethe lithotripsy through theendoscope
![Page 39: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/39.jpg)
2
Article-no. X/Y Diameter (mm) (mm)
Lithotomy baskets, reusable
With a nozzle on the side for injectionof contrast medium
Lithotomy basket, twisted wires
Description
y
x03 11 21 04 10/20 1,8 215
03 11 23 04 15/25 1,8 215
03 11 24 04 20/30 1,8 215
03 11 25 04 25/40 1,8 215
03 11 26 04 30/45 1,8 215
03 11 27 04 40/55 1,8 215
03 11 28 04 45/60 1,8 215
03 11 31 04 10/20 2,3 215
03 11 33 04 15/25 2,3 215
03 11 34 04 20/30 2,3 215
03 11 35 04 25/40 2,3 215
03 11 36 04 30/45 2,3 215
03 11 37 04 40/55 2,3 215
03 11 38 04 45/60 2,3 215
Handle with nozzle for injectionof contrast medium
suitable forlithotripsy
Length(cm)
![Page 40: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/40.jpg)
3
Aus
gabe
2-0
4.04
Article-no. X/Y Diameter (mm) (mm)
Lithotomy baskets, reusable
With a nozzle on the side for injectionof contrast medium
Lithotomy baskets for guide wire, twisted wires
DescriptionGuide wire(inch)
y
x
0.025 0.035
for guide wire0.025 inch
for guide wire0.035 inch
03 11 23 24 15/25 1,8 215 0.025
03 11 24 24 20/30 1,8 215 0.025
03 11 25 24 25/40 1,8 215 0.025
03 11 26 24 30/45 1,8 215 0.025
03 11 27 24 40/55 1,8 215 0.025
03 11 44 34 20/30 2,6 215 0.035
03 11 45 34 25/40 2,6 215 0.035
03 11 46 34 30/45 2,6 215 0.035
03 11 47 34 40/55 2,6 215 0.035
03 11 48 34 45/60 2,6 215 0.035
Handle with nozzle for injection ofcontrast medium. To be used withlying guide wire.
suitable forlithotripsy
Length(cm)
![Page 41: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/41.jpg)
4
03 11 36 08 30/45 2,6 215 —
Article-no. X/Y Diameter (mm) (mm)
Lithotomy baskets, reusable
With a nozzle on the side for injectionof contrast medium
Lithotomy basket, twisted wires
DescriptionGuide wire(inch)
y
x
03 14 44 34 20/30 2,6 215 0.035
Handle with nozzle forinjection of contrast medium
Article-no. X/Y Diameter (mm) (mm)
Lithotomy basket, twisted "double wires"
DescriptionGuide wire(inch)
0.025 0.035
for guide wire0.025 inch
for guide wire0.035 inch
suitable forlithotripsy
x
y
Handle with nozzle for injection ofcontrast medium. To be used withlying guide wire.
Length(cm)
Length(cm)
![Page 42: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/42.jpg)
5
Aus
gabe
2-0
4.04
With a nozzle on the side for injectionof contrast medium
Description
03 12 37 04 35/50 2,3 215 twisted wire
03 12 37 05 35/50 2,3 215 monofil wire
y
x
Article-no. X/Y Diameter (mm) (mm)
Catheter for stone-extraction, 3 monofil wires
Description
x
y
Article-no. X/Y Diameter (mm) (mm)
Lithotomy basket, 6 wires, turned
03 13 22 05 20/20 1,8 215 x = 20 mm, y = 20 mm
03 13 32 05 20/20 2,3 215 x = 20 mm, y = 20 mm
Handle with nozzle forinjection of contrast medium
suitable forlithotripsy
Lithotomy baskets, reusable
Length(cm)
Length(cm)
![Page 43: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/43.jpg)
6
Article-no. X/Y Diameter (mm) (mm)
Lithotomy baskets, reusable
With a nozzle on the side for injectionof contrast medium
Lithotomy basket, diamond-shaped Nitinol®
DescriptionX
Y
03 11 23 02 15/25 1,8 215 4 wires
03 11 24 02 20/30 1,8 215 4 wires
03 11 25 02 25/40 1,8 215 4 wires
03 11 26 02 30/45 1,8 215 4 wires
03 11 27 02 35/55 1,8 215 4 wires
03 11 33 02 15/25 2,3 215 4 wires
03 11 34 02 20/30 2,3 215 4 wires
03 11 35 02 25/40 2,3 215 4 wires
03 11 36 02 30/45 2,3 215 4 wires
03 11 37 02 35/55 2,3 215 4 wires
Handle with nozzle forinjection of contrast medium
NITINOL® is a registered trademark
Not suitable for thelithotripsy!
Length(cm)
Not suitable forthe lithotripsy!
![Page 44: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/44.jpg)
7
Aus
gabe
2-0
4.04
Article-no. X/Y Diameter (mm) (mm)
Lithotomy baskets, reusable
With a nozzle on the side for injectionof contrast medium
Lithotomy basket Nitinol®
Description
03 11 23 03 15/25 1,8 215 6 wires
03 11 24 03 20/30 1,8 215 6 wires
03 11 25 03 25/40 1,8 215 6 wires
03 11 26 03 30/45 1,8 215 6 wires
03 11 27 03 35/55 1,8 215 6 wires
03 11 33 03 15/25 2,3 215 6 wires
03 11 34 03 20/30 2,3 215 6 wires
03 11 35 03 25/40 2,3 215 6 wires
03 11 36 03 30/45 2,3 215 6 wires
03 11 37 03 35/55 2,3 215 6 wires
X
Y
Handle with nozzle forinjection of contrast medium
NITINOL® is a registered trademark
Not suitablefor thelithotripsy!
Not suitable for thelithotripsy!
Length(cm)
![Page 45: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/45.jpg)
8
Article-no. X/Y Diameter (mm) (mm)
Lithotomy baskets, reusable
With a nozzle on the side for injectionof contrast medium
Lithotomy basket, turned, Nitinol®
DescriptionX
Y
Handle with nozzle forinjection of contrast medium
03 12 23 03 15/25 1,8 215 6 wires
03 12 24 03 20/30 1,8 215 6 wires
03 12 25 03 25/40 1,8 215 6 wires
03 12 26 03 30/45 1,8 215 6 wires
03 12 27 03 35/55 1,8 215 6 wires
03 12 33 03 15/25 2,3 215 6 wires
03 12 34 03 20/30 2,3 215 6 wires
03 12 35 03 25/40 2,3 215 6 wires
03 12 36 03 30/45 2,3 215 6 wires
03 12 37 03 35/55 2,3 215 6 wires
NITINOL® is a registered trademark
Not suitablefor thelithotripsy!
Not suitable for thelithotripsy!
Length(cm)
![Page 46: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/46.jpg)
9
Aus
gabe
2-0
4.04
Handle with nozzle forinjection of contrastmedium
Article-no. X/Y Diameter (mm) (mm)
Lithotomy baskets, disposable
Lithotomy basket
Description
99 03 11 35 04 25/40 2,3 215
99 03 11 37 04 40/55 2,3 215
2
y
x
With a nozzle on the side for injectionof contrast medium
Length(cm)
suitable forlithotripsy
All disposable lithotomy baskets are delivered in packaging units.
Packaging unit:5 piecesPackaging unit:5 pieces
![Page 47: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/47.jpg)
10
Article-no. Diametertube (mm)
Emergency-lithotriptor, reusable
Emergency-lithotriptor
Lengthtube (cm)
Description
03 30 0 3,8 100
03 30 6 3,8 100 metal tube, separate
03 36 — — handle for lithotriptor
Article-no. X/Y Diameter (mm) (mm)
Lithotomy basket, twisted wires
Description
y
x
suitable forlithotripsy
03 11 31 04 10/20 2,3 215
03 11 33 04 15/25 2,3 215
03 11 34 04 20/30 2,3 215
03 11 35 04 25/40 2,3 215
03 11 36 04 30/45 2,3 215
03 11 37 04 40/55 2,3 215
03 11 38 04 45/60 2,3 215
03 11 34 06 20/30 2,3 215 6 wires (without illustration)
03 11 36 06 30/45 2,3 215 6 wires (without illustration))
Length(cm)
Fixingsolvable
complete set: consisting of handleand metal tube
![Page 48: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/48.jpg)
1
Lithotriptor, reusable
This lithotriptor is autoclavable.
Additional basket: see page 13 of this chapter!
Lithotripsythrough theendoscope
suitable forlithotripsy
Article-no.
Combi-bile-stone-lithotriptor set
Description
teflon tubeØ 2,3 mm
Ø 3,8 mmlength 100 cm
y
x
x/mm y/mm 40 55
Ø 2,3 mmlength 195 cm
Fixingsolvable
03 31 47 09 Combi-bile-stone-lithotriptor set incl. emergency-lithotriptor
consisting of: handle, 1 metal tube Ø 2,3 mm,length 195 cm for lithotripsy through theendoscope, connector for metal tube Ø 2,3 mm,2 baskets, basket measure x = 40 mm /y = 55 mm, length 4 m with PTFE-introducer-tube, 1 metal tube Ø 3,8 mm, length 100 cmfor emergency lithotripsy without endoscope
03 30 4 Metal tube, separate, Ø 2,3 mm, length 195 cm
03 30 6 Metal tube, separate, Ø 3,8 mm, length 100 cm
03 35 4 Connector for metal tube, Ø 2,3 mm
![Page 49: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/49.jpg)
1
Aus
gabe
2-0
4.04
Article-no. X/Y Diameter (mm) (mm)
Lithotriptor accessories, reusable
With a nozzle on the side for injectionof contrast medium
Additional baskets for lithotriptor
Description
03 31 36 04 30/45 2,3 400 4 wires
03 31 37 04 40/55 2,3 400 4 wires
03 31 38 04 45/60 2,3 400 4 wires
Article-no. X/Y Diameter (mm) (mm)
Additional baskets for lithotriptor
Description
03 32 37 04 35/50 2,3 400 6 wires
y
x
y
x
Nozzle for injectionof contrast medium
suitable forlithotripsy
Length(cm)
Length(cm)
![Page 50: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/50.jpg)
Endoprostheses& PTC-�������
Endoscopic instrumentsand accessories
4
![Page 51: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/51.jpg)
![Page 52: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/52.jpg)
2
Guiding-systems: see page 9, 10, 11
Endoprostheses, disposable
2
Straight endoprostheses, grey, Teflon
Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 00 70 10 03 3 5
04 00 70 10 04 4 6
04 00 70 10 05 5 7
04 00 70 10 06 6 8
04 00 70 10 07 7 9
04 00 70 10 08 8 10
04 00 70 10 09 9 11
04 00 70 10 10 10 12
04 00 70 10 11 11 13
04 00 70 10 12 12 14
04 00 70 10 13 13 15
Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 00 80 10 03 3 5
04 00 80 10 04 4 6
04 00 80 10 05 5 7
04 00 80 10 06 6 8
04 00 80 10 07 7 9
04 00 80 10 08 8 10
04 00 80 10 09 9 11
04 00 80 10 10 10 12
04 00 80 10 11 11 13
04 00 80 10 12 12 14
04 00 80 10 13 13 15
Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 01 00 10 03 3 5
04 01 00 10 04 4 6
04 01 00 10 05 5 7
04 01 00 10 06 6 8
04 01 00 10 07 7 9
04 01 00 10 08 8 10
04 01 00 10 09 9 11
04 01 00 10 10 10 12
04 01 00 10 11 11 13
04 01 00 10 12 12 14
04 01 00 10 13 13 15
Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 01 10 10 03 3 5
04 01 10 10 04 4 6
04 01 10 10 05 5 7
04 01 10 10 06 6 8
04 01 10 10 07 7 9
04 01 10 10 08 8 10
04 01 10 10 09 9 11
04 01 10 10 10 10 12
04 01 10 10 11 11 13
04 01 10 10 12 12 14
04 01 10 10 13 13 15
Length between the flaps
Total length
![Page 53: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/53.jpg)
3
Aus
gabe
2-0
4.04
Guiding-systems: see page 9, 10, 11
Endoprostheses with metal ring, disposable
2
Straight endoprostheses with metal ring, grey, Teflon
Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 20 70 10 03 3 5
04 20 70 10 04 4 6
04 20 70 10 05 5 7
04 20 70 10 06 6 8
04 20 70 10 07 7 9
04 20 70 10 08 8 10
04 20 70 10 09 9 11
04 20 70 10 10 10 12
04 20 70 10 11 11 13
04 20 70 10 12 12 14
04 20 70 10 13 13 15
Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 20 80 10 03 3 5
04 20 80 10 04 4 6
04 20 80 10 05 5 7
04 20 80 10 06 6 8
04 20 80 10 07 7 9
04 20 80 10 08 8 10
04 20 80 10 09 9 11
04 20 80 10 10 10 12
04 20 80 10 11 11 13
04 20 80 10 12 12 14
04 20 80 10 13 13 15
Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 21 00 10 03 3 5
04 21 00 10 04 4 6
04 21 00 10 05 5 7
04 21 00 10 06 6 8
04 21 00 10 07 7 9
04 21 00 10 08 8 10
04 21 00 10 09 9 11
04 21 00 10 10 10 12
04 21 00 10 11 11 13
04 21 00 10 12 12 14
04 21 00 10 13 13 15
Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 21 10 10 03 3 5
04 21 10 10 04 4 6
04 21 10 10 05 5 7
04 21 10 10 06 6 8
04 21 10 10 07 7 9
04 21 10 10 08 8 10
04 21 10 10 09 9 11
04 21 10 10 10 10 12
04 21 10 10 11 11 13
04 21 10 10 12 12 14
04 21 10 10 13 13 15
Length between the flaps
Total length
![Page 54: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/54.jpg)
4
Guiding-systems: see page 9, 10, 11
Endoprostheses, disposable
2
Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 50 70 10 03 3 5
04 50 70 10 04 4 6
04 50 70 10 05 5 7
04 50 70 10 06 6 8
04 50 70 10 07 7 9
04 50 70 10 08 8 10
04 50 70 10 09 9 11
04 50 70 10 10 10 12
04 50 70 10 11 11 13
04 50 70 10 12 12 14
04 50 70 10 13 13 15
Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 50 80 10 03 3 5
04 50 80 10 04 4 6
04 50 80 10 05 5 7
04 50 80 10 06 6 8
04 50 80 10 07 7 9
04 50 80 10 08 8 10
04 50 80 10 09 9 11
04 50 80 10 10 10 12
04 50 80 10 11 11 13
04 50 80 10 12 12 14
04 50 80 10 13 13 15
Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 51 00 10 03 3 5
04 51 00 10 04 4 6
04 51 00 10 05 5 7
04 51 00 10 06 6 8
04 51 00 10 07 7 9
04 51 00 10 08 8 10
04 51 00 10 09 9 11
04 51 00 10 10 10 12
04 51 00 10 11 11 13
04 51 00 10 12 12 14
04 51 00 10 13 13 15
Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 51 10 10 03 3 5
04 51 10 10 04 4 6
04 51 10 10 05 5 7
04 51 10 10 06 6 8
04 51 10 10 07 7 9
04 51 10 10 08 8 10
04 51 10 10 09 9 11
04 51 10 10 10 10 12
04 51 10 10 11 11 13
04 51 10 10 12 12 14
04 51 10 10 13 13 15
Length between the flaps
Total length
Straight endoprostheses, model soft, blue, Polyethylen
![Page 55: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/55.jpg)
5
Aus
gabe
2-0
4.04
Guiding-systems: see page 9, 10, 11
Endoprostheses, disposable
2
Ch. 7.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 60 70 10 03 3 5
04 60 70 10 04 4 6
04 60 70 10 05 5 7
04 60 70 10 06 6 8
04 60 70 10 07 7 9
04 60 70 10 08 8 10
04 60 70 10 09 9 11
04 60 70 10 10 10 12
04 60 70 10 11 11 13
04 60 70 10 12 12 14
04 60 70 10 13 13 15
Ch. 8.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 60 80 10 03 3 5
04 60 80 10 04 4 6
04 60 80 10 05 5 7
04 60 80 10 06 6 8
04 60 80 10 07 7 9
04 60 80 10 08 8 10
04 60 80 10 09 9 11
04 60 80 10 10 10 12
04 60 80 10 11 11 13
04 60 80 10 12 12 14
04 60 80 10 13 13 15
Ch. 10.0 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 61 00 10 03 3 5
04 61 00 10 04 4 6
04 61 00 10 05 5 7
04 61 00 10 06 6 8
04 61 00 10 07 7 9
04 61 00 10 08 8 10
04 61 00 10 09 9 11
04 61 00 10 10 10 12
04 61 00 10 11 11 13
04 61 00 10 12 12 14
04 61 00 10 13 13 15
Ch. 11.5 Length between Total lengthArticle-no. the flaps (cm) (cm)
04 61 10 10 03 3 5
04 61 10 10 04 4 6
04 61 10 10 05 5 7
04 61 10 10 06 6 8
04 61 10 10 07 7 9
04 61 10 10 08 8 10
04 61 10 10 09 9 11
04 61 10 10 10 10 12
04 61 10 10 11 11 13
04 61 10 10 12 12 14
04 61 10 10 13 13 15
Length between the flaps
Total length
Straight endoprostheses, model soft with metal ring, blue, Polyethylen
![Page 56: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/56.jpg)
6
2
Endoprostheses, disposable
Article-no.
10-Flap-endoprostheses, grey, Teflon
Length betweenthe flaps
(cm)
Total lengthCh.
04 00 70 20 05 7.0 5 7,5
04 00 70 20 07 7.0 7 9,5
04 00 70 20 09 7.0 9 11,5
04 00 70 20 12 7.0 12 14,5
04 00 80 20 05 8.5 5 7,5
04 00 80 20 07 8.5 7 9,5
04 00 80 20 09 8.5 9 11,5
04 00 80 20 12 8.5 12 14,5
04 01 00 20 05 10.0 5 7,5
04 01 00 20 07 10.0 7 9,5
04 01 00 20 09 10.0 9 11,5
04 01 00 20 12 10.0 12 14,5
04 01 10 20 05 11.5 5 7,5
04 01 10 20 07 11.5 7 9,5
04 01 10 20 09 11.5 9 11,5
04 01 10 20 12 11.5 12 14,5
Total length
Length between the flaps
(cm)
Guiding-systems: see page 9, 10, 11
![Page 57: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/57.jpg)
![Page 58: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/58.jpg)
8
Article-no.
Double-pigtail-endoprostheses, grey, Teflon
DescriptionTotallength(cm)
Ch.
04 00 70 40 05 7.0 5 9 for guide wire 0.035
04 00 70 40 07 7.0 7 11
04 00 70 40 09 7.0 9 13
04 00 70 40 12 7.0 12 16
04 00 80 40 05 8.5 5 9
04 00 80 40 07 8.5 7 11
04 00 80 40 09 8.5 9 13
04 00 80 40 12 8.5 12 16
Pusher
04 00 71 7 7.0 250
04 00 81 0 8.5 165
Article-no. DescriptionTotallength(cm)
Ch.
Endoprostheses, disposable
2
Length between the pigs
(cm)
Total length
Length cm
"Cleaning connector for pusher Ch. 7 to Ch. 10, see chapter 10 page 8"
![Page 59: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/59.jpg)
04 01 02 20 09 Endoprosthesis, separate, Charr. 10, length between the flaps 6 cm, total length 9 cm
04 01 22 20 09 Endoprosthesis, separate, Charr. 12, length between the flaps 6 cm, total length 9 cm
04 01 42 20 09 Endoprosthesis, separate, Charr. 14, length between the flaps 6 cm, total length 9 cm
Endoprostheses-set
Article-no.
Endoprostheses-setProf. Kautz
Description
04 01 42 2 Endoprostheses-set for large caliber bile duct
consisting of: - 1 guide instrument, Ø 1,8 mm
- 1 pusher
- 1 handle
04 00 22 2 Handle, separate
04 00 02 2 Guide-instrument, separate Ø 1,8 mm
04 00 12 2 Pusher, separate
With the non transendoscopical method ofTPCD higher success rates and improveon results are to obtain than with thetransendoscopical method. Withoutendoscope changes 14 – 18 Frenchendoprostheses can be implanted withduodenoscopes, which suggest smallerearly and late complication and ensure anefficient drainage.
Endoprostheses-set for model Prof. Kautz
Article-no. Description
2
2
2
Length between the flaps
Total length
rechts: Special design on requestpossible in Charr. 10, 12, 14, 16and of the length between5 - 17 cm
![Page 60: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/60.jpg)
1
Aus
gabe
2-0
4.04
Article-no.
These dilatation catheters are radiopaque.
Dilatation catheters for endoprosthesesmodel Prof. Kautz
DescriptionTotallength(cm)
Ch.
Dilatation catheters, reusable
Ch.10 Ch. 12 Ch. 14 Ch. 16 Ch. 18 Ch. 20
04 11 00 01 05 10 105
04 11 20 01 05 12 105
04 11 40 01 05 14 105
04 11 60 01 05 16 105
04 11 80 01 05 18 105
04 12 00 01 05 20 105
![Page 61: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/61.jpg)
1
Article-no.
These dilatation catheters are radiopaque.
Dilatation catheters
DescriptionTotallength(cm)
Ch.
04 10 50 02 00 5 200 guide wire arrestable
04 10 70 02 00 7 200 metal ring inside
04 10 80 02 00 8 200
04 10 90 02 00 9 200
04 11 00 02 00 10 200
04 11 20 02 00 12 200
Dilatation catheters, reusable
0.035
for guide wire0.035 inch
for injection ofcontrast medium
![Page 62: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/62.jpg)
![Page 63: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/63.jpg)
Article-no.
Nasobiliary drainage catheter
Description
04 00 55 54 00 5
04 00 75 54 00 7
04 01 05 54 00 10
Nasobiliary drainage catheters, disposable
2
Ch.
Nasobiliary drainage catheter consisting of:Catheter standard with 7 side holes, length 290 cm,injection connector, funnel 3-way stopcockconnector, length 135 cm, nasal tube, length 50 cm
Article-no.
Nasobiliary drainage catheter
Description
04 00 55 64 00 5
04 00 75 64 00 7
Ch.
Nasobiliary drainage catheter consisting of:Catheter standard with pigtail with & 7 side holes,length 290 cm, injection connector, funnel 3-waystopcock connector, length 135 cm, nasal tube, length50 cm
![Page 64: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/64.jpg)
Aus
gabe
2-0
4.04
Nasobiliary drainage catheters, disposable
Article-no.
Nasobiliary drainage catheter
Description
04 00 55 34 00 5
04 00 75 34 00 7
Ch.
Nasobiliary drainage catheter consisting of:Catheter with pigtail & 8 side holes, length290 cm, injection connector, funnel 3-waystopcock connector, length 135 cm, nasaltube, length 50 cm
2
![Page 65: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/65.jpg)
Article-no.
Pneumatic dilator for treatment ofachalasia
Description
04 20 07 7 Pneumatic dilator model Witzel, complete
04 20 07 8 Dilator, separate
04 20 07 9 Manometer, separate
Pneumatic dilator, reusable
Products showing this sign can besterilized but not autoclaved
134 0C
134 0C
134 0C
134 0C
![Page 66: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/66.jpg)
Polypectomysnares
Endoscopic instrumentsand accessories
5
![Page 67: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/67.jpg)
![Page 68: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/68.jpg)
![Page 69: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/69.jpg)
![Page 70: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/70.jpg)
![Page 71: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/71.jpg)
![Page 72: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/72.jpg)
![Page 73: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/73.jpg)
![Page 74: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/74.jpg)
![Page 75: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/75.jpg)
![Page 76: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/76.jpg)
10
Article-no. Diameter (mm)
Asymmetrical polypectomy snares
Length(cm)
DescriptionOpening-width
(X=mm)
Polypectomy snares, reusable
05 20 10 24 8 2,3 230 40
05 20 30 24 8 2,3 230 40
Extra handleArticle-no. 10 02 07 8
Article-no. Diameter (mm)
Asymmetrical polypectomy snares
Length(cm)
DescriptionOpening-width
(X=mm)
05 20 10 26 8 2,3 230 60
05 20 30 26 8 2,3 230 60
x =
40x
= 60
Use this polypectomy snareonly with the enclosed handleplease.
Use this polypectomy snareonly with the enclosed handleplease.
isolated tip
![Page 77: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/77.jpg)
![Page 78: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/78.jpg)
![Page 79: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/79.jpg)
![Page 80: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/80.jpg)
![Page 81: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/81.jpg)
15
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Coagulation probe with nozzle for sucking off
Length(cm)
Description
Coagulation probe, reusable
10 25 05 2 2,3 215
![Page 82: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/82.jpg)
![Page 83: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/83.jpg)
![Page 84: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/84.jpg)
![Page 85: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/85.jpg)
Biopsy-forcepsRectoscopy-forceps
& shaft
Endoscopic instrumentsand accessories
6
![Page 86: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/86.jpg)
![Page 87: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/87.jpg)
![Page 88: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/88.jpg)
![Page 89: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/89.jpg)
![Page 90: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/90.jpg)
5
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Biopsy-forceps, reusable
Biopsy-forceps, alligator jaws
Description
06 10 03 00 1 0,75 160
06 10 03 00 4 0,75 230
06 11 03 00 1 1,0 160
06 11 03 00 3 1,0 230
06 13 03 00 1 1,5 160
06 13 03 00 3 1,5 230
Biopsy-forceps, alligator jaws, with spike
Article-no. Diameter (mm)
06 15 13 11 1 2,2 160 fenestrated, tapered
06 15 13 11 4 2,2 230 fenestrated, tapered
Description
Length(cm)
Length(cm)
Handle used for PTFE-coated forceps
Handle, standard
PTFE-coating and nozzle on the side to wash-out is possible by request
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 91: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/91.jpg)
6
Article-no. Diameter (mm)
Biopsy-forceps, reusable
Biopsy-forceps, oval spoonshaped mouth with one tooth
Description
06 15 07 10 1 2,2 160 fenestrated, tapered
06 15 07 10 4 2,2 230 fenestrated, tapered
Biopsy-forceps, oval spoonshaped swinging mouth, without spike
Article-no. Diameter (mm)
06 15 02 22 5 2,2 180 fenestrated, tapered
Description
Length(cm)
Length(cm)
Handle used for PTFE-coated forceps
Handle, standard
PTFE-coating and nozzle on the side to wash-out is possible by request
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 92: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/92.jpg)
7
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Biopsy-forceps, reusable
Biopsy-forceps, oval spoonshaped swinging mouth, with tooth
Handle, standard
Description
06 15 03 22 5 2,2 180 fenestrated, tapered
Biopsy-forceps, oval spoonshaped, lateral mouth, without spike
Article-no. Diameter (mm)
06 14 08 00 1 1,8 160 fenestrated, tapered
06 15 08 00 5 1,8 180
06 14 08 00 2 1,8 230
06 14 08 20 1 2,2 160
06 15 08 20 5 2,2 180
06 14 08 20 2 2,2 230
DescriptionLength(cm)
Length(cm)
Handle used for PTFE-coated forceps
PTFE-coating and nozzle on the side to wash-out is possible by request
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 93: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/93.jpg)
8
Article-no. Diameter (mm)
Hot-biopsy-forceps, reusable
Hot-biopsy-forceps, oval spoonshaped mouth
Description
06 28 01 00 1 3,4 160
06 28 01 00 4 3,4 230
Hot-biopsy-forceps, oval spoonshaped mouth
Article-no. Diameter (mm)
Description
Handle with a nozzleon the side to wash-out
isolated, PTFE-coated
06 24 02 00 1 1,8 160 isolated, PTFE-coated
06 24 02 00 4 1,8 230
06 25 02 00 1 2,2 160
06 25 02 00 5 2,2 180
06 25 02 00 4 2,2 230
06 26 02 00 1 2,6 160
06 26 02 00 5 2,6 180
06 26 02 00 4 2,6 230
Length(cm)
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 94: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/94.jpg)
9
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Rectoscopy-forceps, reusable
Rectoscopy-forceps, inflexible, PTFE-coated
Description
06 35 02 10 0 2,2 50 without spike, fenestrated (a)
06 35 02 11 0 2,2 50 with spike, fenestrated (b)
Rectoscopy-forceps, inflexible, PTFE-coated
Article-no. Diameter (mm)
06 38 01 10 0 3,4 50 without spike, fenestrated (c)
06 38 01 11 0 3,4 50 with spike, fenestrated (d)
Description
(a) (b)
(c) (d)
All rectoscopy-forceps arePTFE-coated
Length(cm)
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 95: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/95.jpg)
1
Aus
gabe
2-0
4.04
Accessories, reusable
Clip for instruments
Article-no. Description
00 20 0The clips for instruments are manufactured with high-qualitysurgical steel and therefore
- guaranteed stainless- autoclavable by 134° C- extremely durable
The clips for instruments are the solution of:- safekeeping of your guide wires and flexible accessories
The clips for instruments prevent from tangling of guide wiresand are suitable for all diameters of guide wires and accessorieslike ERCP-catheters and polypectomy snares.
Minimum order qty.: 25 pieces
Stopper for handleArticle-no. Description
00 10 0 the stoppers are to be used
- for effective reprocessing of biopsy- and foreign-body removingforceps
- as tension stopper to avoid too strong bending for example withpapillotomes
By putting on the stopper at the handle of forceps it is ensuredthat the spoons at the distal end will stay open during repro-cessing and no blood or tissue particles adhere at the spoons.Minimum order quantity 25 pieces"
![Page 96: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/96.jpg)
Foreign-bodyremoving
forceps
Endoscopic instrumentsand accessories
7
![Page 97: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/97.jpg)
1
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Foreign-body removing forceps, reusable
These foreign-body removing forceps have a Teflon tube and a nozzle on theside to wash-out
Polypotome with Teflon tube
Handle with a nozzle on the sideto wash-out
DescriptionLength(cm)
07 20 21 3 2,5 160 30 3-arm
07 20 22 3 2,5 230 30 3-arm
07 34 41 3 2,5 160 30 4-arm
07 34 42 3 2,5 230 30 4-arm
07 35 51 3 2,5 160 30 5-arm
07 35 52 3 2,5 230 30 5-arm
Stationary polypotome, 3-arm
07 20 21 4 2,6 160 25 3-arm
07 20 22 4 2,6 230 25 3-arm
Opening-width
(X=mm)x
Article-no. Diameter (mm)
DescriptionLength(cm)
Opening-width
(X=mm)
x
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 98: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/98.jpg)
2
Article-no. Diameter (mm)
DescriptionLength(cm)
Opening-width
(X=mm)
Foreign-body removing forceps, reusable
Foreign-body removing forceps with Teflon tube
07 20 11 3 2,5 160 30 3-arm
07 20 12 3 2,5 230 30 3-arm
07 34 01 3 2,5 160 30 4-arm
07 34 02 3 2,5 230 30 4-arm
07 35 01 3 2,5 160 30 5-arm
07 35 02 3 2,5 230 30 5-arm
These foreign-body removing forceps have a Teflon tube and anozzle on the side to wash-out
x
Handle with a nozzle on the sideto wash-out
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 99: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/99.jpg)
3
Aus
gabe
2-0
4.04
Length(cm)
Opening-width
(X=mm)
Article-no. Diameter (mm)
07 10 11 0 1,8 160 30 3-nail
07 10 12 0 1,8 230 30
07 20 11 0 2,2 160 30
07 20 12 0 2,2 230 30
Article-no. Diameter (mm)
Length(cm)
Opening-width
(X=mm)
Foreign-body removing forceps, reusable
Polypotome, metal spring
Handle
Foreign-body removing forceps, metal spring
Description
07 20 21 0 2,2 160 30 3-arm
07 20 22 0 2,2 230 30 3-arm
Description
x
x
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 100: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/100.jpg)
4
Article-no. Diameter (mm)
Foreign-body removing forceps, reusable
Foreign-body removing forceps, „W-shape“, metal spring
Handle
Description
07 10 41 0 1,8 160
07 10 42 0 1,8 230
07 20 41 0 2,2 160
07 20 42 0 2,2 230
Foreign-body removing forceps, forked jaws, metal spring
Article-no. Diameter (mm)
Description
07 10 51 0 1,8 160
07 10 52 0 1,8 230
07 20 51 0 2,2 160
07 20 52 0 2,2 230
Length(cm)
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 101: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/101.jpg)
5
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Foreign-body removing forceps, reusable
Foreign-body removing forceps, metal spring
Handle
Description
07 10 71 0 1,8 160 alligator jaws
07 10 72 0 1,8 230
07 20 71 2 2,2 160 tapered
07 20 72 2 2,2 230 tapered
Foreign-body removing forceps, metal spring
Article-no. Diameter (mm)
07 20 91 0 2,2 160 long alligator jaws
07 20 92 0 2,2 230 long alligator jaws
Description
Length(cm)
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 102: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/102.jpg)
6
Article-no. Diameter (mm)
Foreign-body removing forceps, reusable
Foreign-body removing forceps, rat-tooth
Handle
Description
07 10 61 0 1,8 160
07 10 62 0 1,8 230
07 20 61 0 2,2 160
07 20 62 0 2,2 230
07 30 61 0 3,0 160
07 30 62 0 3,0 230
Foreign-body removing forceps, rat-tooth
Article-no. Diameter (mm)
Description
07 21 31 0 2,2 160 long alligator jaws
07 21 32 0 2,2 230 long alligator jaws
Length(cm)
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 103: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/103.jpg)
7
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Foreign-body removing forceps, reusable
Foreign-body removing forceps, long alligator jaws, metal spring
Handle
Description
07 21 01 0 2,2 160
07 21 02 0 2,2 230
Grasping forceps for nutrition probes
Article-no. Diameter (mm)
07 31 24 3 2,5 320
Description
Length(cm)
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 104: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/104.jpg)
8
Article-no. Diameter (mm)
Foreign-body removing forceps, reusable
Foreign-body removing forceps, metal spring
Description
07 10 31 0 1,8 160 flat overlay, toothed
07 10 32 0 1,8 230
07 20 31 0 2,2 160
07 20 32 0 2,2 230
PEG-forceps, metal spring
Article-no. Diameter (mm)
Description
Handle
07 21 23 0 2,6 180
Length(cm)
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 105: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/105.jpg)
9
Aus
gabe
2-0
4.04
Article-no. Diameter (mm)
Foreign-body removing forceps, reusable
Forceps, scissor-shaped, metal spring
DescriptionLength (cm)
Stamp for threads, metal spring
Article-no. Diameter (mm)
Description
Handle
07 20 81 0 2,2 160
07 20 82 0 2,2 230
07 21 11 0 2,2 160
07 21 12 0 2,2 230
Length(cm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 106: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/106.jpg)
Cytology-& Cleaning-
brushes
Endoscopic instrumentsand accessories
8
![Page 107: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/107.jpg)
1
Aus
gabe
2-0
4.04
Cleaning-brushes
DescriptionLength(cm)
Cleaning-brushes, reusable
08 03 10 1 3 160 Ø metal spring 1,8 mm
08 03 20 1 3 230
08 04 10 1 4 160
08 04 20 1 4 230
08 05 10 1 5 160
08 05 20 1 5 230
08 06 10 1 6 160
08 06 20 1 6 230
Article-no. Diameterbrush (mm)
![Page 108: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/108.jpg)
2
Double-cleaning-brush
Description
08 03 10 2 3 160 Ø metal spring 1,8 mm
08 03 20 2 3 230
08 04 10 2 4 160
08 04 20 2 4 230
08 05 10 2 5 160
08 05 20 2 5 230
08 06 10 2 6 160
08 06 20 2 6 230
Cleaning-brushes, reusable
Article-no. Diameterbrush (mm)
Length(cm)
![Page 109: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/109.jpg)
3
Aus
gabe
2-0
4.04
Cleaning-brushes
DescriptionArticle-no.
08 43 05 0 3 1,6 100
08 43 15 0 3 1,6 180
08 43 25 0 3 1,6 230
08 45 15 0 5 2,0 180
08 45 25 0 5 2,0 230
Double-cleaning-brushes
DescriptionLength(cm)
Article-no. Diameterbrush (mm)
08 43 15 2 3 1,6 180
08 43 25 2 3 1,6 230
08 45 15 2 5 2,0 180
08 45 25 2 5 2,0 230
All disposable cleaning-brushes are delivered in packaging units.
Cleaning-brushes, disposable
2
Diameterbrush (mm)
Length(cm)
Packaging unit:20 pieces
Packaging unit:20 pieces
Diameter (mm)
Diameter(mm)
![Page 110: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/110.jpg)
4
Cytology-brushes, reusable
Article-no.
Cytology-brushes
DescriptionLength(cm)
08 12 10 1 2,5 1,8 160 Ø Teflon tube 1,8 mm
08 12 20 1 2,5 1,8 230 Ø Teflon tube 1,8 mm
08 23 10 1 3,0 2,0 160 Ø Teflon tube 2,2 mm
08 23 20 1 3,0 2,0 230 Ø Teflon tube 2,2 mm
Diameterbrush (mm)
Diameterball (mm)
![Page 111: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/111.jpg)
Cytology-brushes
Description
Cytology-brushes, disposable
2
All disposable cleaning-brushes are delivered in packaging units.
08 32 01 1 2,5 1,8 120 Broncho
08 33 11 1 3,0 2,2 160 Gastro
08 33 21 1 3,0 2,2 220 Colo
Length(cm)
Diametercatheter (mm)
Article-no. Diameterbrush (mm)
Packaging unit:10 pieces
![Page 112: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/112.jpg)
Sclerosing-needles& Needles for
fibrinadhesive-injection
Endoscopic instrumentsand accessories
9
![Page 113: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/113.jpg)
1
Aus
gabe
2-0
4.04
Sclerosing-needles, reusable
Article-no. Description
Sclerosing-needles, Teflon
Handle, one hand usage
Diametercannula (mm)
09 10 51 82 18 1,8 0,5 180
09 10 71 82 18 1,8 0,7 180
09 10 71 82 23 2,3 0,7 180
09 10 72 32 23 2,3 0,7 230
09 11 01 82 23 2,3 1,0 180
09 11 02 32 23 2,3 1,0 230
09 11 21 82 23 2,3 1,2 180
09 11 22 32 23 2,3 1,2 230
5 mm
Length(cm)
Diameter(mm)
![Page 114: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/114.jpg)
2
Sclerosing-needles, reusable
Sclerosing-needles, Teflon
09 10 71 85 23 2,3 0,7 180
09 10 72 35 23 2,3 0,7 230
Handle with nozzle on the sideto wash-out
Sclerosing-needles, metal
09 10 51 81 18 1,8 0,5 180
09 10 71 81 23 2,3 0,7 180
09 10 72 31 23 2,3 0,7 230
09 11 01 81 23 2,3 1,0 180
09 11 02 31 23 2,3 1,0 230
Handle, one hand usage
5 mm
5 mm
Article-no. DescriptionDiametercannula (mm)
Length(cm)
Diameter(mm)
Article-no. DescriptionDiametercannula (mm)
Length(cm)
Diameter(mm)
![Page 115: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/115.jpg)
![Page 116: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/116.jpg)
![Page 117: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/117.jpg)
5
Aus
gabe
2-0
4.04
Sclerosing-needles, two-way for fibrinadhesive-injection
09 25 51 64 26 2,6 0,5 / 0,5 160
09 27 51 64 26 2,6 0,5 / 0,7 160
09 27 71 64 26 2,6 0,7 / 0,7 160
09 27 51 84 26 2,6 0,5 / 0,7 180
09 27 71 84 26 2,6 0,7 / 0,7 180
09 25 52 34 26 2,6 0,5 / 0,5 230
09 27 52 34 26 2,6 0,5 / 0,7 230
09 27 72 34 26 2,6 0,7 / 0,7 230
Handle
6 mm
Sclerosing-needles, two-way, reusable
Article-no. DescriptionDiametercannula (mm)
Length(cm)
Diameter(mm)
![Page 118: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/118.jpg)
6
Sclerosing-needles, two-way for fibrinadhesive-injection
99 09 27 51 64 26 2,6 0,5 / 0,7 160
99 09 27 71 64 26 2,6 0,7 / 0,7 160
99 09 27 51 84 26 2,6 0,5 / 0,7 180
99 09 27 71 84 26 2,6 0,7 / 0,7 180
99 09 27 52 34 26 2,6 0,5 / 0,7 230
99 09 27 72 34 26 2,6 0,7 / 0,7 230
Handle
26
mm
All disposable fibrin-needles are delivered in packaging units.
Sclerosing-needles, two-way, disposable
Article-no. DescriptionDiametercannula (mm)
Length(cm)
Diameter(mm)
Packaging unit:2 pieces
![Page 119: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/119.jpg)
![Page 120: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/120.jpg)
8
Biopsy-cannula, reusable
Semi-flexible bronchoscope-cannula
09 21 00 81 21 2,1 1,0 80
Handle
12 mm
Article-no. DescriptionDiametercannula (mm)
Length(cm)
Diameter(mm)
![Page 121: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/121.jpg)
Accessories
Endoscopic instrumentsand accessories
10
![Page 122: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/122.jpg)
![Page 123: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/123.jpg)
![Page 124: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/124.jpg)
Foreign body protector hood
Article-no. Description
10 02 00 7 A soft rubber hood to be used on distal end of mostendoscopes in order to protect the cardiac sphincter,oesophagus and pharynx during removal of a foreign bodyvia the endoscopic tract.
Balloon for ultrasonic-endoscopeArticle-no. Description
Accessories, disposable
2
10 70 1 Echo-hood, model Olympus, 2 openings
10 70 2 Echo-hood, model Olympus, 2 openings
10 70 3 Echo-hood, model Pentax, 1 opening
10 70 4 Echo-hood, model Olympus, 1 opening
Packaging unit:20 pieces
![Page 125: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/125.jpg)
![Page 126: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/126.jpg)
![Page 127: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/127.jpg)
Aus
gabe
2-0
4.04
Accessories, reusable
Clip for instruments
Article-no. Description
00 20 0The clips for instruments are manufactured with high-qualitysurgical steel and therefore
- guaranteed stainless- autoclavable by 134° C- extremely durable
The clips for instruments are the solution of:- safekeeping of your guide wires and flexible accessories
The clips for instruments prevent from tangling of guide wiresand are suitable for all diameters of guide wires and accessorieslike ERCP-catheters and polypectomy snares.
Minimum order qty.: 25 pieces
Stopper for handleArticle-no. Description
00 10 0 the stoppers are to be used
- for effective reprocessing of biopsy- and foreign-body removingforceps
- as tension stopper to avoid too strong bending for example withpapillotomes
By putting on the stopper at the handle of forceps it is ensuredthat the spoons at the distal end will stay open during repro-cessing and no blood or tissue particles adhere at the spoons.Minimum order quantity 25 pieces"
![Page 128: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/128.jpg)
![Page 129: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/129.jpg)
Bronchoscope-instruments
Endoscopic instrumentsand accessories
11
![Page 130: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/130.jpg)
1
Aus
gabe
2-0
4.04
Biopsy-forceps, reusable
Biopsy-forceps, round spoonshaped mouth, without spike
11 06 11 01 00 1,0 120
11 06 14 11 10 1,8 120 tapered
11 06 15 11 10 2,2 120 tapered
Biopsy-forceps, round spoonshaped mouth, with spike
11 06 15 11 11 2,2 120 tapered
Handle, standard
PTFE-coating and nozzle on the side to wash-out is possible by request
Handle used forPTFE-coatedforceps
Article-no. DescriptionLength(cm)
Diameter(mm)
Article-no. DescriptionLength(cm)
Diameter(mm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 131: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/131.jpg)
2
Biopsy-forceps, reusable
Biopsy-forceps, oval spoonshaped mouth, without spike
11 06 11 02 00 1,0 120
11 06 14 02 10 1,8 120 fenestrated, tapered
11 06 15 02 10 2,2 120 fenestrated, tapered
Biopsy-forceps, oval spoonshaped mouth, with spike
11 06 14 02 11 1,8 120 fenestrated, tapered
Handle, standard
PTFE-coating and nozzle on the side to wash-out is possible by request
Handle used forPTFE-coatedforceps
Article-no. DescriptionLength(cm)
Diameter(mm)
Article-no. DescriptionLength(cm)
Diameter(mm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 132: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/132.jpg)
3
Aus
gabe
2-0
4.04
Biopsy-forceps and foreign-body removingforceps, reusable
Biopsy-forceps, alligator jaws
11 06 11 03 00 1,0 120
Foreign-body removing forceps, alligator jaws
11 07 10 7 1,8 120 tapered
11 07 20 7 2,2 120 tapered
Handle, standard
PTFE-coating and nozzle on the side to wash-out is possible by request
Handle used forPTFE-coatedforceps
Article-no. DescriptionLength(cm)
Diameter(mm)
Article-no. DescriptionLength(cm)
Diameter(mm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 133: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/133.jpg)
4
Foreign-body removing forceps, reusable
Foreign-body removing forceps, metal
Foreign-body removing forceps, rat-tooth
11 07 10 6 1,8 120
Handle, standard
x
11 07 10 1 1,8 120 30 3-arm
Handle, standard
PTFE-coating and nozzle on the side to wash-out is possible by request
Handle used forPTFE-coatedforceps
Article-no. Diameter (mm)
DescriptionLength(cm)
Opening-width
(X=mm)
Article-no. DescriptionLength(cm)
Diameter(mm)
Stopper for handle to be used for reprocessing, chapter 6, page 11 and chapter 10, page 9
![Page 134: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/134.jpg)
5
Aus
gabe
2-0
4.04
Lithotomy baskets, reusable
X
y
X
y
Lithotomy basket
11 12 45 90 4 35/50 1,3 120
Lithotomy basket
11 03 11 23 04 15/25 1,8 120
Handle with nozzle forinjection of contrast medium
DescriptionArticle-no. X/Y Diameter (mm) (mm)
Length(cm)
DescriptionArticle-no. X/Y Diameter (mm) (mm)
Length(cm)
![Page 135: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/135.jpg)
6
Lithotomy baskets, reusable
Lithotomy baskets
y
x11 03 11 21 04 10/20 1,8 120
11 03 11 31 04 10/20 2,3 120
11 03 11 33 04 15/25 2,3 120
Lithotomy baskets, 6 wires
11 03 11 34 06 20/30 2,3 120
11 03 11 36 06 30/45 2,3 120
X
Y
Handle with nozzle forinjection of contrast medium
DescriptionArticle-no. X/Y Diameter (mm) (mm)
Length(cm)
DescriptionArticle-no. X/Y Diameter (mm) (mm)
Length(cm)
![Page 136: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/136.jpg)
7
Aus
gabe
2-0
4.04
Aspiration-needles, reusable
Aspiration-needles, teflon
11 09 10 72 18 1,8 0,7 120 model „a“
11 09 11 01 23 2,3 1,0 120 model „a“
12 m
m
Handle, one hand usage
Article-no. Description
11 09 10 71 18 1,8 0,7 120 model „b“
11 09 10 71 23 2,3 1,0 120 model „b“
12 m
m
model „a“ model „b“
Aspiration-needles, metal
Aspiration-needle, disposable
09 10 71 22 16 1,8 0,7 120
10 m
m
2
Length(cm)
Diameter(mm)
Diametercannula (mm)
Article-no. DescriptionLength(cm)
Diameter(mm)
Diametercannula (mm)
Article-no. DescriptionLength(cm)
Diameter(mm)
Diametercannula (mm)
Packaging unit:5 pieces
![Page 137: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/137.jpg)
8
Biopsy-cannula, reusable
Flexible biopsy-cannula for bronchoscopy
09 20 71 22 18 1,8 0,7 120 12
09 21 01 22 23 2,3 1,0 120 12
Handle
x
09 21 00 81 21 2,1 1,0 80
12 m
m
Coated metalspring
Article-no. DescriptionDiametercannula (mm)
Length(cm)
Diameter(mm)
X(mm)
Semi-flexible bronchoscope-cannula
Article-no. DescriptionDiametercannula (mm)
Length(cm)
Diameter(mm)
![Page 138: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/138.jpg)
Cytology-brushes, reusable
Cytology-brushArticle-no.
11 08 12 01 1,8 1,8 120
11 08 23 01 2,2 2,0 120
Description
13 m
m
Length(cm)
Ø brush: 3,0 mm,brush-length 13 mm
Ø brush: 2,5 mm,brush-length 13 mm
Diameter (mm)
Diameterball (mm)
![Page 139: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/139.jpg)
1
Aus
gabe
2-0
4.04
Cytology-brushes, disposable
Cytology-brushes
2
All disposable cytology-brushes are delivered in packaging units.
08 32 01 1 2,5 1,8 120 brush-length 10 mm
10 m
m
DescriptionLength(cm)
Diametercatheter (mm)
Article-no. Diameterbrush (mm)
Packaging unit:10 pieces
![Page 140: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/140.jpg)
1
Double-cleaning-brush
11 08 04 02 4,0 130
11 08 06 02 6,0 130
Cleaning-brushes, reusable
DescriptionArticle-no. Diameterbrush (mm)
Length(cm)
![Page 141: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/141.jpg)
1
Aus
gabe
2-0
4.04
Cleaning-brushes
08 43 05 0 3 100
08 43 15 0 3 180
08 43 25 0 3 230
08 45 15 0 5 160
08 45 25 0 5 230
08 43 15 2 3 180
08 43 25 2 3 230
08 45 15 2 5 180
08 45 25 2 5 230
All disposable cleaning-brushes are delivered in packaging units.
Cleaning-brushes, disposable
2
DescriptionArticle-no. Diameterbrush (mm)
Length(cm)
Packaging unit:20 pieces
Double-cleaning-brushes
DescriptionLength(cm)
Article-no. Diameterbrush (mm)
Packaging unit:20 pieces
![Page 142: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/142.jpg)
1
Ballooncatheter, disposable
Ballooncatheter for the bronchoscopy
Article-no. Diameter (Ch.)
11 03 20 51 20 5 100 x = 12 mm
11 03 20 72 30 7 100 x = 16 mm
Description
2
xLength
(cm)
![Page 143: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/143.jpg)
1
Aus
gabe
2-0
4.04
Symmetrical snare, reusable
Symmetrical polypectomy snare, twisted wire
11 12 24 59 0 1,5 120 15 / 20
Y
X
Handle with a nozzle onthe side to wash-out
Article-no. Diameter (mm)
Length(cm)
DescriptionOpening-width X/Y
(mm)
![Page 144: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/144.jpg)
1
Wash-out-/Spray-catheter, reusable
Wash-out-catheterArticle-no. Diameter
(mm)
11 01 20 10 0 1,6 120
11 01 30 90 0 2,3 120
11 31 01 21 0 2,3 120
11 21 01 21 3 1,6 120
11 31 01 21 3 2,3 120
Description
SpraycatheterArticle-no. Diameter
(mm)
11 01 01 21 0 1,8 120
11 01 01 31 0 2,3 120
Description
Length(cm)
Length(cm)
(a) (b) (c)
with color markings (a)
with color markings(a)
with metal head and color markings (b)
with metal head (c)
with metal head (c)
![Page 145: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/145.jpg)
Guide wires
Endoscopic instrumentsand accessories
12
![Page 146: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/146.jpg)
1
Aus
gabe
2-0
4.04
Article-no. Diameter(inch)
Guide wires, reusable
Kink resistant guide wire NITINOL®
Length(cm)
00 18 00 0.018 400 blue-black
Description
Article-no. Diameter(inch)
Kink resistant guide wire NITINOL®
00 22 00 0.025 400 green-black
Description
NITINOL® is a registered trademark
50 mm Platinum tip
50 mm Platinum tip
Length(cm)
![Page 147: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/147.jpg)
2
Article-no. Diameter(inch)
Guide wires, reusable
Kink resistant guide wire NITINOL®
00 32 26 0.035 260 yellow-black
00 32 00 0.035 400 yellow-black
Description
Article-no. Diameter(inch)
Kink resistant guide wire NITINOL®
soft-tip
Description
00 34 00 0.035 400 yellow-blue,with soft-tip
NITINOL® is a registered trademark
50 mm Platinum tip
Length(cm)
Length(cm)
50 mm Platinum tip
![Page 148: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/148.jpg)
3
Aus
gabe
2-0
4.04
Article-no. Diameter(inch)
Guide wires, reusable
Kink resistant guide wire NITINOL®
J-wire
Description
Article-no. Diameter(inch)
Kink resistant guide wire NITINOL®
J-soft-tip
Description
00 36 00 0.035 400 yellow-blue,J-wire,with soft-tip
00 35 00 0.035 400 yellow-black,J-wire
NITINOL® is a registered trademark
50 mm Platinum tip
50 mm Platinum tip
Length(cm)
Length(cm)
![Page 149: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/149.jpg)
4
Article-no. Diameter(inch)
Guide wire, disposable
Kink resistant guide wire NITINOL®
00 37 00 0.035 400 yellow-black, hydrophilic
coated
Description
2
NITINOL® is a registered trademark
Length(cm)
50 mm Platinum tip
300 mm hydrophilic coated
![Page 150: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/150.jpg)
5
Aus
gabe
2-0
4.04
Article-no. Diameter(inch)
Guide wires, reusable
Kink resistant guide wire NITINOL®
00 23 00 0.025 460 black-white
00 33 00 0.035 460 black-white
Description
Article-no. Diameter(inch)
Guide wire, model Seldinger
Description
00 21 00 0.025 400 flexible tip, length 50 mm
00 35 30 0.035 300 flexible tip, length 10 mm
00 31 00 0.035 400 flexible tip, length 50 mm
NITINOL® is a registered trademark
50 mm Platinum tip
Length(cm)
Length(cm)
![Page 151: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/151.jpg)
6
Article-no. Diameter(inch)
Guide wires, reusable
Guide wire, model Eder-Püstow
00 17 21 5 0.057 215 flexible tip, length 60 mm
00 17 35 0 0.057 350 flexible tip, length 60 mm
Description
Article-no. Diameter(inch)
00 38 00 0.035 400 flexible tip
Description
Kink resistant guide wire NITINOL®
with scale
NITINOL® is a registered trademark
50 mm Platinum tip
Length(cm)
Length(cm)
![Page 152: MTW.pdf · ERCP-catheter, reusable All ERCP-catheters with mandrin, and nozzle for injection of contrast medium suitable for guide wire ERCP-catheter,](https://reader033.vdocuments.mx/reader033/viewer/2022060814/6093541b90cc6e7624588d4d/html5/thumbnails/152.jpg)