User Manual for the ISA Sequencer ModuleTRANSCRIPT
-
DATE : 09/18/2008 DOC. MSE10021 REV. 5.1.3
SEQUENCER
User Manual
REV. 5.1.3
-
DOC. MSI10021 REV. 5.1.3 Page 2/29
REVISION DESCRIPTION OF CHANGES VISA
N PAG. DATE
1 All 09/18/2008 Version 5.1.3 Released Rossoni
-
DOC. MSI10021 REV. 5.1.3 Page 3/29
1 Preface .......................................................................................................................................... 4
2 Program Start ................................................................................................................................ 5
2.1 Connection to the instrument ............................................................................................... 5
2.2 File menu.............................................................................................................................. 7
2.2.1 New .................................................................................................................................. 7
2.2.2 Open ................................................................................................................................. 7
2.2.3 Save .................................................................................................................................. 8
2.2.4 Save into TDMS............................................................................................................... 9
2.2.5 Notes to the test .............................................................................................................. 10
2.2.6 Print ................................................................................................................................ 11
2.2.7 Exit (ESC) ...................................................................................................................... 12
2.3 Header menu ...................................................................................................................... 13
2.4 Window menu .................................................................................................................... 13
2.4.1 Sequence editor .............................................................................................................. 13
2.4.2 Contacts .......................................................................................................................... 13
2.4.3 Waveform viewer ........................................................................................................... 13
2.4.4 Tile vertical .................................................................................................................... 14
2.5 Settings menu ..................................................................................................................... 14
2.5.1 Digital Inputs Type ........................................................................................................ 14
2.6 Language menu .................................................................................................................. 15
2.7 Menu ?................................................................................................................................ 15
2.7.1 About .......................................................................................................................... 15
2.7.2 Instrument Information .................................................................................................. 15
2.7.3 ISA Web Site ................................................................................................................. 15
3 Sequences definition window ..................................................................................................... 16
3.1 Toolbar ............................................................................................................................... 17
3.2 Cycle frame ........................................................................................................................ 18
3.3 Cycle frame of the Prefault cycle ....................................................................................... 19
3.4 Cycle frame of a Generic cycle .......................................................................................... 20
3.4.1 Header info of the Cycle ................................................................................................ 20
3.4.2 Output values of the cycle .............................................................................................. 22
3.4.3 Main contacts frame ....................................................................................................... 24
3.4.4 Auxiliary contacts frame ................................................................................................ 27
4 Waveform viewer window ......................................................................................................... 28
-
DOC. MSI10021 REV. 5.1.3 Page 4/29
1 Preface
The program SEQUENCER has been designed as an interactive test software for all I.S.A.
Automatic relay test sets, to test any kind of relay: this tool is a sequence editor that allows the user
to build and run a sequence defined by consecutive cycles or steps. It is useful to search trip and
reset thresholds, trip and reset times, control trip contacts and auxiliary contacts, display the
waveform created by the cycles definition.
When uploaded to the instrument, all the cycles of the defined sequence will be executed step by
step.
Each cycle is defined by the output values of currents and voltages, the state of auxiliary contacts,
by a condition for the timing start and a condition for the timing stop of the cycle itself.
The user can define the condition of transition from one cycle to the next one: this may take place
after a fixed timeout time, a trigger (trip or reset) condition of the main contacts of the connected
instrument or by pressing a button by the user himself.
In every cycle the user defines if the output condition is a Value Injection, a Ramp or if the
instrument must hold values of the previous cycle.
For each cycle of value injection type the user defines amplitude, phase, frequency values of
currents and voltages.
For each cycle of ramp type the user defines initial value and rate of change values for amplitude,
phase and frequency of currents and voltages.
The waveform viewer displays graphically the time signals of voltages, currents, auxiliary contacts
and main contacts and is useful to study the reaction of the protection relay.
With this tool you can save and reload created sequences, so that you can repeat you test
indefinitely; finally you can print them with professional reports that allow to export in Acrobat
Reader Format (*.PDF), Microsoft Word Format (*.DOC) and Microsoft Excel Format (*.XLS).
The program is completely integrated with the database of TDMS.
IMPORTANT NOTICE:
The menu items are NOT active if the instrument is not connected. If the user wants to
operate in not-connected mode, wait for about 15 seconds and the program will ask whether
to try to re-connect to the instrument and then press No on the message box that follows.
Only at this point the main window will open and the menu items will be enabled.
-
DOC. MSI10021 REV. 5.1.3 Page 5/29
2 Program Start
2.1 Connection to the instrument
When the program starts, it opens a window to set the connection parameters to the instrument.
Connect the instrument to the PC, select the connection mode (COM port or USB) and press OK.
If the program is not able to perform the connection with the given settings, it will display the
following window:
By pressing on Yes the program will try again the connection to the instrument. By pressing
No, the main window of the program will open and it will work in not-connected mode, as shown
in the status bar at the bottom of the main window:
-
DOC. MSI10021 REV. 5.1.3 Page 6/29
IMPORTANT NOTICE:
1) The menu items of the program are NOT enabled until the instrument is connected. If the user wants to operate in not-connected mode, he has to wait for about 15 seconds and the
program will ask whether to try to re-connect to the instrument and then press No on the
message box that follows. Only at this point the main window will open and the menu items
will be enabled.
2) Depending on the type of the connected instrument, the program will allow to set the amplitudes for a number of voltages and currents that correspond to those present on the
instrument. Similarly, the number of main contacts and auxiliary contacts will depend on the
connected instruments capabilities.
If the program runs in not-connected mode, by default it will be possible to use the settings
for a DRTS.6: four voltages, six currents, ten main trip contacts and four auxiliary contacts.
It is possible to create and save a sequence in not-connected mode too. This sequence will
then be executed when the instrument is actually connected. Voltages (for instance V4) and
currents (for instance I4, , I6) that are not present on the instrument will be ignored.
The window that allows the user to define the instrument type and the connection
parameters does not show up if in the Set Comm program (that can be run from TDMS
under Additional Programs Utilities), the Choose model at startup option is not selected.
When the program opens the following window is automatically displayed:
-
DOC. MSI10021 REV. 5.1.3 Page 7/29
2.2 File menu
2.2.1 New
By selecting this menu item, the program will display a new sequence, starting from the prefault
cycle. In case modifications have already been made to a sequence and the modifications have not
yet been saved, the program will ask to save the sequence before creating a new one.
2.2.2 Open
By selecting this menu item, the standard Microsoft Windows file selection window is opened:
By browsing the directories, it will be possible to open a file previously saved with Sequencer or by
the Manual program of TDMS (only if the file contains a sequence). Before opening a new
sequence, if there are modifications to the current sequence that have yet not been saved, the
program will first prompt the user with the option to save the modifications.
-
DOC. MSI10021 REV. 5.1.3 Page 8/29
2.2.3 Save
By selecting this menu item, the standard Microsoft Windows file selection window is opened:
By pressing the Save button, the program saves the sequence and the results that may have been
obtained in a Sequencer format file, with the name chosen by the user and in the selected directory.
-
DOC. MSI10021 REV. 5.1.3 Page 9/29
2.2.4 Save into TDMS
This menu item allows the user to export the opened sequence into the TDMS database. By
selecting this menu item, the following window opens, and allows the user to select the node of the
network tree created by TDMS into which the sequence must be saved.
To export the opened sequence, select the relay node in which the sequence must be saved, choose a
descriptive name for the file and press the Save button. By pressing the Cancel button, the
sequence will not be saved into TDMS.
-
DOC. MSI10021 REV. 5.1.3 Page 10/29
2.2.5 Notes to the test
By selecting this menu item, the following window is opened:
In the text box it is possible to write notes that can be included in the printed report. By pressing the
button Ok the notes will be saved along with the sequence. By pressing the Cancel button, all
changes to the notes will be discarded.
HINT: in the text field it is possible to insert text and images coming from other programs such as
Acrobat Reader or Microsoft Word.
-
DOC. MSI10021 REV. 5.1.3 Page 11/29
2.2.6 Print
By selecting this menu item, the following window opens:
By checking the option Include Notes Page the report will include a page containing the notes
added by means of the menu item Notes to the test (see paragraph 2.2.5).
In the Column Selection frame the user can select one by one up to nine parameters, which will
be included into the report.
It is also possible to insert a customized logo at the top of the report. By pressing the button
Change Report Logo the following window opens:
The button Browse allows to select the image file (*.BMP, *.JPG, *.TIFF or *.GIF) with the
customers logo by browsing through the computer or network directories. By pressing Ok the
window is closed and the logo is stored into the print preview. By pressing the Cancel button, the
window is closed but modifications are not saved.
Press the button Print preview to open a preview of the actual sequence printout.
-
DOC. MSI10021 REV. 5.1.3 Page 12/29
The toolbar at the top of this window is the following:
The first four buttons allow the user to browse thorough the pages of the report
(first, previous, next and last page).
The button allows the user to print the report, after selecting the printer.
The button allows the user to export the report in the Adobe Acrobat (*.pdf), Microsoft Excel
(*.xls), Microsoft Word (*.doc) or Rich Text Document (*.rtf) formats, by selecting the type
from the drop down menu, as shown in the following picture:
The button allows the user to zoom in or out the print preview.
2.2.7 Exit (ESC)
Select this menu item to close the program. If a sequence is opened and modifications have been
performed, the program will first prompt the user to save the modification before closing the
program.
-
DOC. MSI10021 REV. 5.1.3 Page 13/29
2.3 Header menu
By selecting this menu item, the following window is opened. It contains info that allows for the
traceability of the test results. They are saved and printed along the results and include: the name of
the Substation (Plant name), name of the Line (Feeder), info that identify the relay, such as
Manufacturer, Model and Serial number. Furthermore the Operator and the ISA Instrument Serial
Number can be added. Other fields are optional.
By pressing the Ok button, the modifications will be saved along with the opened sequence and
shown again at the next program startup.
2.4 Window menu
2.4.1 Sequence editor
By selecting this menu item, it is possible to hide or view the main window for the definition of the
sequence cycles.
2.4.2 Contacts
This menu item allows the user to view or hide the secondary window for the selection of some
parameters related to the main and auxiliary contacts (see paragraph 3.4.3).
2.4.3 Waveform viewer
By selecting this menu item, it is possible to view or hide the window that displays the waveforms
of the selected sequence.
-
DOC. MSI10021 REV. 5.1.3 Page 14/29
2.4.4 Tile vertical
This menu item allows the user to tile vertically the main window for the definition of the sequence
and the waveform viewer window.
2.5 Settings menu
2.5.1 Digital Inputs Type
By selecting this menu item, the following window opens, and it is possible to define the settings
for the input contacts of the connected instrument. This option applies only for instruments type
DRTS, DRTS.3, DRTS.6 and ART100:
There are three possible settings for the type of the contact: Dry contact, DC voltage or AC voltage.
In case of dry contacts it is not possible to select the voltage threshold. On the contrary, when the
contact is wet, it is also possible to select the threshold: all inputs lower than the 80% of the
threshold are zeroed. This prevents sensing a false contact status in case there is a protective resistor
in parallel to the contact driving the breaker coil, in which case the Open contact does not
correspond to zero volts. Available thresholds are 5V (for the digital inputs); 24 V; 48 V; over 100
V. This selection should correspond to the wetting voltage of the contacts.
If dry input is selected and a voltage is applied the instrument does not suffer, provided that the
input is no more than 220 V. If a voltage is selected and the input is not polarized, the trip is not
sensed.
If a wrong voltage threshold is selected:
1) Thresholds higher than the voltage: the trip is not sensed.
2) Thresholds lower than the voltage; the contact could be found closed when it is open.
With AC voltage selection the debounce is automatically set to 2000 us to avoid the zero crossing
of the input.
-
DOC. MSI10021 REV. 5.1.3 Page 15/29
The debounce is the time during which the instrument waits for the input to become stable: this
avoids stopping the test because of noise, and also to ignore contact bounces. When a transition is
sensed the debounce counter starts: any opposite transition before the debounce expires resets the
counter. Only if the input does not change for the programmed duration the input is accepted, and
the timer stopped. Default value 100us. With electronic inputs, the value can be programmed to 0s.
With heavy contacts the debounce is better programmed to 2000us (maximum value). The time
measurement is not affected by this selection.
2.6 Language menu
This menu allows the user to change the language of the program. The selection is saved and used
also the next time the program starts.
2.7 Menu ?
2.7.1 About
By selecting this menu item a window is displayed to show the software release version and the info
on how to contact us with an internet link to our website (see paragraph 2.7.3).
2.7.2 Instrument Information
By selecting this menu item, when the instrument is connected it is possible to display its hardware
settings (firmware revision, booster option, IEC61850 option, and so on).
2.7.3 ISA Web Site
By selecting this menu item, the default web browser will be opened to the page www.isatest.com.
From this website it is possible to download the firmware upgrades for the instrument or the latest
version of our software.
2.7.4 Help On Line
By selecting this menu item or pressing F1 key, this manual will be opened automatically.
http://www.isatest.com/ -
DOC. MSI10021 REV. 5.1.3 Page 16/29
3 Sequences definition window
This is the main window of the program, and it allows defining all cycles of the sequence, each one
with its voltage and current magnitudes and with the proper settings of main and auxiliary contacts.
A sequence is made up of an initial cycle of type Prefault that cannot be deleted, and by a series
of cycles that follow.
The info that defines a cycle parameters are contained in a frame, as shown in the following picture:
The cycle of the previous picture is active, as displayed by the red horizontal bar at the top of the
frame.
In the following picture two cycles are displayed; cycle n.1 is active and can be changed, whereas
cycle n.2 is not active and therefore the parameters cannot be changed.
To activate a cycle it is sufficient to click on the grey bar at the top of the cycle or on any part of the
frame that holds all the cycle values.
-
DOC. MSI10021 REV. 5.1.3 Page 17/29
After having defined a sequence it is possible to execute it by pressing the button Start sequence.
PLEASE NOTE: all pictures that display the frames holding the cycle values of this manual are
referred to the ISA instrument DRTS.6, which is the default instrument used in case the program
works in not-connected mode. That is why there are four voltages, six currents, ten main contacts
and four auxiliary contacts.
3.1 Toolbar
As the main program window is opened, the toolbar displayed is like the following:
After the first cycle has been added, the toolbar will become the following:
The meaning of the buttons is the following:
New Cycle: by pressing this button a new cycle is added after the one currently selected. Those
cycles on the right of the selected cycle will be right-shifted of one position to allow the insertion of
the new cycle.
Delete Cycle: by pressing this button, the cycle currently selected is deleted. Before deleting the
program warns the operator asking for confirmation. The first Prefault cycle cannot be deleted.
Copy Cycle: by pressing this button, the cycle currently selected is saved to allow the pasting of a
copy into any position of the sequence. Copying a cycle means to copy ALL data relative to the
selected cycle (header, voltage/current values, main contacts settings with optional messages for the
operator, auxiliary contacts settings). The initial Prefault cycle cannot be copied.
Cut Cycle: similar to the Copy cycle option. The difference is that the selected cycle for copy is
deleted from the sequence, without asking confirmation to the user. To undo the Cut operation, it is
possible to select the cycle before the one that has been deleted and press the button Paste cycle.
Paste Cycle: the cycle that has been selected for Copy or for Cut is inserted immediately after the
selected cycle. Cycles that may follow the selected one, are right-shifted of one position to allow the
insertion of the Copied or Cut cycle.
Waveform Viewer: by pressing this button the Waveform viewer window is displayed (see chapter
4)
Start Sequence: this button allows to start the currently opened sequence, by sending it to the
instrument and executing it. The instrument must be connected to run the sequence.
Stop Sequence: by pressing this button, the software sends to the instrument a command of
immediate stop of the currently running sequence. The prefault values are then applied. The
instrument must be connected to stop a sequence.
Reset Sequence: by pressing this button, the software sends to the instrument a command of
immediate stop of the currently running sequence. Furthermore all voltages and currents are
immediately reset to zero.
-
DOC. MSI10021 REV. 5.1.3 Page 18/29
3.2 Cycle frame
A sequence is made up of a series of cycles that can be freely added, copied, cut or deleted. The
only cycle that it is not possible to delete is the first cycle, which is the Prefault cycle. This frame
can be logically divided into four areas:
1) Header of the cycle
2) Table with the voltage and current values
3) Definition of the main contacts status: the contacts can be set to normally open or normally closed and the trip time can be measured on the trip or the reset of the contact; this part is
not present on the prefault cycle
4) Definition of the auxiliary contacts: the auxiliary contacts present on the instrument can be controlled to be open or close
There are two types of cycle frames:
1) Cycle frame of the Prefault cycle
2) Cycle frame of a Generic cycle
-
DOC. MSI10021 REV. 5.1.3 Page 19/29
3.3 Cycle frame of the Prefault cycle
The frame for the Prefault cycle or zero cycle is shown in the following picture:
It is the first cycle of the sequence and cannot be deleted (in order to avoid generating a prefault, it
is possible to set Tprefault to zero). This cycle is needed to:
1) set the value of the protection DC supply voltage
2) define the amplitude, phase and frequency of the voltages and currents present on the instrument
3) set the duration in seconds of the prefault
4) define whether the auxiliary contacts are opened or closed at the start of the first cycle
5) set a maximum safety value for all voltage and current outputs
-
DOC. MSI10021 REV. 5.1.3 Page 20/29
3.4 Cycle frame of a Generic cycle
The cycle frame of a Generic cycle added to the sequence is shown in the following picture:
It is possible to insert a new cycle in any position of the sequence, following the prefault cycle.
When the New cycle button is pressed, the cycle will be added immediately after the selected one
(that is the one with the red horizontal bar at the top of the frame). Cycles that may be on the right
of the selected one will be right-shifted of one position to allow the insertion of the new cycle.
3.4.1 Header info of the Cycle
In the header info of a cycle it is possible to add the following details:
1) Cycle name: it is a text field that allows to describe the cycle
2) Cycle type: the cycle can be of type Value Injection or Ramp; in the former case the injected values are constant in amplitude, phase and frequency for the duration of the whole
cycle; in the latter case it is necessary to define whether to set the gradients (ROC: rate of
change) on the amplitude, on the frequency or on the phase. By selecting this cycle type, the
following frame becomes visible
-
DOC. MSI10021 REV. 5.1.3 Page 21/29
The first option (ROC I/V) will allow to define the gradients on the amplitudes of the
voltages and currents; the second option (ROC Freq in Hz/s) sets the gradient on the
frequency parameter; the third and last option (ROC Phase) allows to set the gradient on the
phases of the voltages and currents. By modifying these options it can be noted that in the
voltages and currents tables some columns will be displayed or hidden to set the value of the
gradients. In case of Frequency ROC the value of the gradient can be set in the box that is
displayed immediately on the right of the option
3) Freq (Hz): it represents the value of the frequency of all voltage and current outputs injected by the instrument. The items in the following drop-down menu
allow to define whether the frequency is applied to All phases, to V1 only, to all voltages, to
all voltages and I1, to all voltages and currents excluding V4, only to V1 and V2. If the
selected option is different from the default one, it will be possible to set the frequency that
has to be applied to the selected option: outputs not included in the list will be generated
with the frequency set in the prefault cycle
4) Hold Previous Cycle Values: this option is enabled only if the preceding cycle is of type Ramp or if the preceding cycle has this option selected; if this option is checked then the
instrument will hold the values of the previous cycle and therefore, as an example, a ramp
will start from the values reached by the previous ramp, as shown in the following picture
(in this example, both cycles 2 and 3 have the option Hold Previous Cycle Values
checked):
5) Initial Fault Angle: this parameter allows the user to check the instantaneous value of the currents and the voltages at the starting of the fault. Since the outputs are only sinusoidal,
the parameter is expressed in degrees. By selecting 0 degrees, the fault will start when the
parameter is zero: by selecting 90 degrees, the fault will start when the parameter will reach
the highest value (corresponding to 90deg). Since voltages and currents do not have the
same phase and since when the test starts all parameters are applied at the same time, it is
necessary to define which parameter controls the Initial Fault Angle. This selection is
performed by choosing the reference output and the relative initial fault angle. The fault will
be executed when the reference output matches the angle condition; all other outputs will
-
DOC. MSI10021 REV. 5.1.3 Page 22/29
maintain an initial phase relative to the phase difference with the reference output (see the
Phase column in the grid for the definition of output values). In this way, at the start of the
fault, the continuity of the prefault values can be maintained
6) Absolute Angles: normally the prefault values do not change their angle unless they are programmed to have different values: this guarantees the continuity of the parameters
applied to the relay between the prefault and the fault conditions. When the Initial Fault
Angle and the reference output are set as explained in the preceding point, the instrument
starts the test when its internal angular reference matches the selected angle. This method
though, does not guarantee that the fault angle of two different synchronized units is the
same. If on the contrary the option Absolute Angles is selected, all angles will be modified
at the start of the test, independently from the value of the voltage or current of the prefault.
This allows to synchronize the outputs of two units on the same logical input; normally in
these tests the prefault values are set to zero
7) DC Supply (V): set this field to the value of the DC voltage that the instrument has to inject from the dedicated output to polarize the protection relay
3.4.2 Output values of the cycle
In the grids below the header info, it is possible to set the amplitude and phase values, or the
gradient of the amplitude or phase of each output. For the Ramp cycles, the actual values reached in
the cycle will also be displayed. The number of outputs depends on the connected instrument. In the
following examples, the connection to a DRTS.6 is simulated.
In case of the option type Value Injection or type Ramp with further option frequency ramp
(ROC Freq) the grid is structured as in the following picture:
In this case it is possible to set the r.m.s. value of the voltage or of the current and the phase value
relative to the various outputs.
In case of option type Ramp with further option current or voltage ramp (ROC I/V) the grid is
structured as in the following picture:
In this grid it is possible to modify voltage and current starting values (columns [Start V] and [Start
A]), the value of the gradient expressed in a second (columns [V/s] and [A/s]) and the value of the
relative phase in degrees between voltages and currents (columns [Ph ()]) that will be maintained
-
DOC. MSI10021 REV. 5.1.3 Page 23/29
constant for the duration of the entire cycle. Columns [Stop V] and [Stop A] cannot be modified and
will be set by the program with the values reached by the outputs during the cycle execution.
In case the cycle has the option Hold Previous Cycle Values checked, the columns [Start V],
[Start A], and [Ph ()] for currents and voltages will not be modifiable (symbol [-]), as shown in the
following picture, since the instrument will hold the values reached by the previous cycle:
In case of option Ramp with further option Phase ramp (ROC phase) the grid is structured as in
the following picture:
It is possible to modify the voltage and current values ([V] e [A]) that will be maintained constant
during the entire cycle duration, the starting value of the phases (columns [Start ]) and the value of
the gradient expressed degrees per second (columns [ / s ]). The columns [Stop ] and [Stop ] are
not modifiable and will be set by the program with the values reached by the outputs during the
cycle execution.
In case the cycle has the option Hold Previous Cycle Values checked, the columns [V], [A], and
the columns [Start ] for the currents and the voltages will not be modifiable (symbol [-]), as
displayed in the following picture:
-
DOC. MSI10021 REV. 5.1.3 Page 24/29
3.4.3 Main contacts frame
This frame allows the user to set the conditions for the transition from one cycle to the next to
happen. In the Tmax field the user has to set the maximum timeout in seconds after which the
sequence executes the next cycle even if there has been no contact trip. The enabled contact is C1
by default: therefore as a predefined setting, the transition to the next cycle happens when the
contact C1 closes. To enable other contacts, it is enough to click on the green icon at the side of the
label C2, , C10, as displayed in the following picture:
NOTE: the number of contacts displayed depends on the connected instrument. If the user is
working in not-connected mode, the default setting is that for the DRTS.6 instrument, that has 10
contacts.
By clicking on the contact it is possible to modify the status:
(NORMALLY OPEN) means that in this cycle the contact will be considered normally open
(NORMALLY CLOSE) means that in this cycle the contact will be considered normally
closed
(NOT AVAILABLE) means that in this cycle the transitions of this contact will not be
sensed
For the transition conditions, please remember to set the parameters relative to the contacts as
explained in the paragraph 2.5.
By default the instrument measures the trip of the contact. By pressing the button Next cycle
transition the following window is opened:
-
DOC. MSI10021 REV. 5.1.3 Page 25/29
Time Tmax is identical to the one set in the frame of the cycle in the main window. In the Tnom
field it is possible to set the nominal trip time of the relay connected to the instrument. It is
important to set this parameter for the cycles of type Ramp. To refine the results on tests of this
type, Tnom is used. As the relay trips, the measured value reached by the ramp is corrected
according to the following formula:
(Result) = (Measure) (Value of the gradient)*(Tnom)
In the drop-down menu Start Timer it is possible to select the moment in which the measure of
the trip has to start, setting therefore if the timer for the current cycle starts at the start of the cycle
itself or at the trip or reset of a main contact.
For each contact of the connected instrument it is possible to set:
1) LABEL column: optional free description
2) STATUS column: sets the default condition of the contact during the cycle (Normally open, not applicable, or normally closed). By clicking on the images of the contact status, it is
possible to cycle through all possible statuses of the contact; the modifications made on the
status will be immediately copied into the cycle frame of the main window
3) STOP TIMER column: sets whether the instrument has to consider the transition time of the contact on the first edge (trip) or on the following edge (reset)
The following picture shows the meaning of trip and reset.
-
DOC. MSI10021 REV. 5.1.3 Page 26/29
By clicking on the label C1-4: dry and C5:8: dry the window for the Setting of the Hardware
status of the contacts is opened (see paragraph 2.5).
The button Define Message allows adding an optional message for the user on the selected cycle.
It has been designed to stop the sequence during the execution before executing the selected cycle.
By pressing this button the following window is opened:
The fields Message and Note can contain images or parts of documents (for example Acrobat
Reader, and so on ) that may be useful as help and operative instruction for the operator.
-
DOC. MSI10021 REV. 5.1.3 Page 27/29
If the option Enable Message is checked, the execution of the sequence will be paused before
executing the selected cycle and a window with the message will appear. To continue the sequence,
the operator will have to acknowledge the message by pressing on the Ok button.
3.4.4 Auxiliary contacts frame
This frame allows the user to activate the auxiliary contacts of the connected instrument during the
selected cycle. By clicking on the icon placed on the side of the label A1, , A4, the logical
condition of the contact will be modified (open or close):
auxiliary contact is open
auxiliary contact is close
By pressing on the button Auxiliary Contacts the following window will be opened:
This window allows the programming of the timing of the auxiliary contacts with respect to the
other parameters (auxiliary contacts are A1, A2 for UTB, UTS and ART/3; are A1, A2, A3 and A4
for DRTS, DRTS.3, DRTS.6 and ART/100) expressed in seconds. For each auxiliary contact it is
possible to set an optional label, the status of the contact (the modifications will be immediately
copied in the cycle frame of the main window) and the delay time of the closing or opening of the
contact in seconds. The minimum time selectable is actually the maximum resolution, which is
10msec.
-
DOC. MSI10021 REV. 5.1.3 Page 28/29
4 Waveform viewer window
By pressing the button Show waveform viewer in the toolbar of the main window or choosing the
menu item Waveform Viewer from the Window menu, a new window is opened. This window
displays the waveform of the voltages, currents, the trip time of the main contacts and the timing of
the auxiliary contacts, as shown in the following picture:
In this window it is possible to define these main areas:
1) Toolbar, that will be explained later in this chapter
2) Header of the cycles: each cycle in the sequence is represented by a blue horizontal bar; the duration of the cycle before test execution is equal to the Tmax value in seconds; at the end
of the sequence execution is equal to the maximum time between the trips or resets of the
contacts enabled for the cycle. A blue vertical line separates one cycle from the next
3) Graphic of all current waveforms: it shows the time waveforms for the current outputs; the envelopes are superimposed and given a different colour; the y-axis scale is set to the
maximum value in Ampere between all of the visible waveforms; the values are intended to
be r.m.s.
4) Graphic of all voltage waveforms: it shows the time waveforms for the voltage outputs; the envelopes are superimposed and given a different colour; the y-axis scale is set to the
maximum value in Volt between all of the visible waveforms; the values are intended to be
r.m.s.
5) Graphic of the main contacts (that are displayed only when the sequence has been executed) and of the auxiliary contacts. The open contact is represented with a thin line,
the closed contact with a wider line
1 2
3
4
5
6 7
8
9
10
-
DOC. MSI10021 REV. 5.1.3 Page 29/29
6) Cursor T1: it is a vertical red line that can be moved with the left button of the mouse, by clicking it or dragging the mouse holding the button down. The label below the graph shows
the time corresponding to the cursor position with an approximation of one millisecond
7) Cursor T2: it is a vertical blue line that can be moved with the right button of the mouse, by clicking it or dragging the mouse holding the button down. The label below the graph shows
the time corresponding to the cursor position with an approximation of one millisecond
8) Difference in seconds between T2 and T1
9) Current options panel: by clicking on the side of the labels I1, , I6 it is possible to display or hide the envelopes of the current outputs. By clicking on the label with the colour
a window is opened to allow the user to select the colour for the selected waveform. In the
label on the side of the colour the program displays the r.m.s. value of the corresponding
output
10) Voltage options panel: by clicking on the side of the labels V1, , V4 it is possible to display or hide the envelopes of the voltage outputs. By clicking on the label with the colour
a window is opened to allow the user to select the colour for the selected waveform. In the
label on the side of the colour the program displays the r.m.s. value of the corresponding
output
The toolbar at the top of this window is the following:
1) Zoom button: by pressing this button it is possible to enable the zoom mode; once having accessed this mode, by clicking on the mouse on the currents, on the voltages or on the contacts,
dragging the mouse and then releasing the mouse button, the program will zoom in the selected
area
2) Magnify Display: by pressing this button the program will zoom in the area between the cursors T1 and T2
3) Display all: by pressing this button the program will restore the graphics to the initial values, by setting T1 to zero seconds and T2 to the maximum value that is the sum of all the maximum
time duration of the cycles
4) Show/Hide Currents: by pressing this button it is possible to hide or display the graphic of the currents
5) Show/Hide Voltages: by pressing this button it is possible to hide or display the graphic of the voltages
PrefaceProgram StartConnection to the instrumentFile menuNewOpenSaveSave into TDMSNotes to the testPrintExit (ESC)Header menuWindow menuSequence editorContactsWaveform viewerTile verticalSettings menuDigital Inputs TypeLanguage menuMenu ?AboutInstrument InformationISA Web SiteHelp On LineSequences definition windowToolbarCycle frameCycle frame of the Prefault cycleCycle frame of a Generic cycleHeader info of the CycleOutput values of the cycleMain contacts frameAuxiliary contacts frameWaveform viewer window