ms performance max - red line calibration...
TRANSCRIPT
www.targetanalysis.grwww.msstandards.com
Calibration Solutions for Thermo mass spectrometers
RED LINE
Creating Solutions
RED LINECreating Solutions
Specifically Designedfor Thermo MassS p e c t r o m e t e r s
Thermo mass spectrometers images andlogo are courtesy of Thermo Scientific TM.
We have the Solutions to satisfy your every needSelection Guide for Thermo Scientific™ Mass Spectrometers
Highly recommendedNot recommended
LXQ
LCQ Fleet
LTQ XL
LTQ Velos
LTQ Velos Pro
LTQ Orbitrap Discovery
LTQ Orbitrap XL
LTQ Orbitrap Velos
LTQ Orbitrap Velos Pro
Orbitrap ELITE
Orbitrap Fusion Tribrid
Exactive
Exactive Plus
Q Exactive/Q Exactive Plus
LTQ FT Ultra
TSQ Access Max
TSQ Quantum Discovery
TSQ Quantum Ultra
TSQ Vantage
TSQ Endura
TSQ Quantiva
Creating SolutionsLTQ XL / Hybrid CalMixNormal Mass Range, Positive
TFS200
Creating SolutionsLTQ Velos / Hybrid CalMixNormal Mass Range, Positive
TFS210
Creating SolutionsLTQ / Hybrid CalMix
Normal Mass Range, Negative
TFS220
Creating SolutionsTSQ Polytyrosine 1, 3, 6
Positive / Negative
TFS300
4
Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.
Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.
Precise formulation. Solution of Caff eine, MRFA & Ultra Mark 1621 in ACN/MeOH/Water/AcOH matrix.Specialized. Developed and qualifi ed specifi cally for use with LTQ XL/Hybrid family instruments.
High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.
Compatible MassSpectrometers
LXQLCQ Fleet
LTQ XLLTQ Orbitrap Discovery
LTQ Orbitrap XL Exactive
LTQ FT Ultra
Creating Solutions
TFS200 LTQ XL / Hybrid CalMix Normal Mass Range. For Calibration Mode
The MSPerformance MAX™ LTQ XL / Hybrid CalMix, enables calibration of Thermo Scientifi c Ion Traps, Orbitraps and Hybrid (IT/FT) Mass Spectrometers in positive ion mode. It covers a mass range from
m/z 138 to m/z 1822, and can be used for instrument calibrations between m/z 50 and 2000.
Ordering Information Product Number TFS200 Description LTQ XL / Hybrid CalMix Volume 10ml
TFS200_16042501_ORBI_TL180_mz120-2000 #1-100 RT: 0.01-0.79 AV: 100 NL: 1.45E7T: FTMS + p ESI Full ms [120.00-2000.00]
200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rel
ativ
e Ab
unda
nce
195.0869
1421.97411521.96781321.9808
524.2631
1621.9609
262.6352
1221.9879
1721.9544
1121.99461821.9472
1022.0010 1921.9397
138.0656
O N N
NN
O H
O
N 2H
S
ONH
NH
NHN2H
ONH
ONH
OH
HF O
P NP
NP
O
F
N
O
F
FFF
F
F F
FF
F F
O
F
F
FF
FF
F F
O
F
F
F F
FF
F F
FF
F
FFF
F
O
F F
FF
FF
FF
H
MSPerformance MAX™ TFS200 ESI Positive Spectrum.
5
Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.Precise formulation. Solution of n-Butylamine, Caff eine, MRFA & Ultra Mark 1621 in ACN/MeOH/Water/AcOH matrix.Specialized. Developed and qualifi ed specifi cally for use with LTQ Velos/Hybrid family instruments.High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.
Compatible MassSpectrometersLTQ VelosLTQ Velos ProLLTQ Orbitrap VelosLTQ Orbitrap Velos ProOrbitrap ELITEOrbitrap Fusion TribridExactive PlusQ Exactive/Q Exactive Plus
Creating Solutions
LTQ Velos / Hybrid CalMix TFS210 For Calibration Mode. Normal Mass Range The MSPerformance MAX™ LTQ Velos / Hybrid CalMix, enables calibration of Thermo Scientifi c Ion Traps (Velos family), Orbitraps, Hybrid (IT/FT or Q/FT) and Tribrid (Q/IT/FT) Mass Spectrometers in positive ion mode. It covers a mass range from m/z 74 to m/z 1822, and can be used for instrument calibrations between m/z 50 and 2000.
Ordering Information Product Number TFS210 Description LTQ Velos / Hybrid CalMix Volume 10ml
TFS210_16042502_ORBI_TL120_mz50-2000 #1-100 RT: 0.00-0.79 AV: 100 NL: 2.74E7T: FTMS + p ESI Full ms [50.00-2000.00]
262.6354
195.0871
1521.96851421.9748
1621.96151321.9814
524.2633 1721.95521221.9886
1821.94831121.9951
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rel
ativ
e Ab
unda
nce
74.0958N2H H
O N N
NN
O H
O
N 2H
S
ONH
NH
NHN2H
ONH
ONH
OH
HF O
P NP
NP
O
F
N
O
F
FFF
F
F F
FF
F F
O
F
F
FF
FF
F F
O
F
F
F F
FF
F F
FF
F
FFF
F
O
F F
FF
FF
FF
H
MSPerformance MAX™ TFS210 ESI Positive Spectrum.
6
TFS220 LTQ / Hybrid CalMix Normal Mass Range. For Calibration Mode
The MSPerformance MAX™ LTQ / Hybrid CalMix, enables calibration of Thermo Scientifi c Ion Trap, Orbitrap, Hybrid (IT/FT or Q/FT) and Tribrid (Q/IT/FT) Mass Spectrometers in negative ion mode. It covers a mass range
from m/z 265 to m/z 1880, and can be used for instrument calibrations between m/z 50 and 2000.
Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.
Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.
Precise formulation. Solution of n-Butylamine, Caff eine, MRFA & Ultra Mark 1621 in ACN/MeOH/Water/AcOH matrix. Specialized. Developed and qualifi ed specifi cally for use with LTQ Velos/Hybrid family instruments.
High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.
Compatible MassSpectrometers
LXQLCQ Fleet
LTQ XLLTQ Velos
LTQ Velos ProLTQ Orbitrap Discovery
LTQ Orbitrap XL LTQ Orbitrap Velos
LTQ Orbitrap Velos ProOrbitrap ELITE
Orbitrap Fusion TribridExactive / Exactive PlusQ Exactive / Q Exactive Plus
Creating Solutions
Ordering Information Product Number TFS220 Description LTQ / Hybrid CalMix Volume 10ml
OS
O
O OH
- H
TFS220_16042503_ORBI_TL120_mz120-2000_NEG #1-100 RT: 0.00-0.82 AV: 100 NL: 4.74E7T: FTMS - p ESI Full ms [120.00-2000.00]
200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rel
ativ
e Ab
unda
nce
265.1474
514.2832
1479.98201379.9888 1579.97601679.96921279.9951
1779.96201180.0015 1886.1016
1986.0954
O
OH
F OP N
PNP
O
F
N
O
F
FFF
F
F F
FF
F F
O
F
F
FF
FF
F F
O
F
F
F F
FF
F F
FF
F
FFF
F
O
F F
FF
FF
FF
- H
SO
OOHNH
OH OH
O
OH
- H
MSPerformance MAX™ TFS220 ESI Negative Spectrum.
7
TSQ Polytyrosine 1, 3, 6 TFS300 For or Calibration ModeThe MSPerformance MAX™ TSQ Polytyrosine 1, 3, 6 calibration solution, enables auto-tune and calibration of Thermo Scientifi c Triple Stage Quadrupole Mass Spectrometers in positive or negative ion mode. It covers a mass range from m/z 182 to m/z 997, and can be used for instrument calibrations between m/z 50 and 1500.
Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.Precise formulation. Solution of Tyrosine, Tri-Tyrosine & Hexa-Tyrosine in MeOH/Water/FA matrix.Specialized. Developed and qualifi ed specifi cally for use with TSQ Quantum family instruments.High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.
Compatible MassSpectrometersTSQ Access MaxTSQ Quantum DiscoveryTSQ Quantum UltraTSQ VantageTSQ EnduraTSQ Quantiva
Creating Solutions
Ordering Information Product Number TFS300 Description TSQ Polytyrosine 1,3,6 Volume 10ml
MSPerformance MAX™ TFS300 ESI Positive Spectrum.
TFS300_16033101_TSQ_1 #1-100 RT: 0.02-2.09 AV: 100 NL: 1.23E7T: + p ESI Q1MS [150.070-1050.000]
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rel
ativ
e Ab
unda
nce
508.1581
997.4144
182.0571
N 2HOH
O
OH
H
O
N 2HOHO
NH
OH
ONH
OH
OH
H
O
N 2HOH
O
NH
OH
O
NH
OH
O
NH
OH
O
NH
OH
O
NH
OH
OH
Contact Us . . .
Powered by
Creating Solutions
We Can Help_
Webwww.targetanalysis.grwww.msstandards.com
Target Analysis S.A.13 Papanikolaou Avenue 57010 PefkaThessaloniki, Greece
Τ (0030) 231 0 580765F (0030) 231 0 580764