ms performance max - red line calibration...

8
www.targetanalysis.gr www.msstandards.com Calibration Solutions for Thermo mass spectrometers RED LINE Creating Solutions

Upload: others

Post on 11-Aug-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

www.targetanalysis.grwww.msstandards.com

Calibration Solutions for Thermo mass spectrometers

RED LINE

Creating Solutions

Page 2: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

RED LINECreating Solutions

Specifically Designedfor Thermo MassS p e c t r o m e t e r s

Thermo mass spectrometers images andlogo are courtesy of Thermo Scientific TM.

Page 3: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

We have the Solutions to satisfy your every needSelection Guide for Thermo Scientific™ Mass Spectrometers

Highly recommendedNot recommended

LXQ

LCQ Fleet

LTQ XL

LTQ Velos

LTQ Velos Pro

LTQ Orbitrap Discovery

LTQ Orbitrap XL

LTQ Orbitrap Velos

LTQ Orbitrap Velos Pro

Orbitrap ELITE

Orbitrap Fusion Tribrid

Exactive

Exactive Plus

Q Exactive/Q Exactive Plus

LTQ FT Ultra

TSQ Access Max

TSQ Quantum Discovery

TSQ Quantum Ultra

TSQ Vantage

TSQ Endura

TSQ Quantiva

Creating SolutionsLTQ XL / Hybrid CalMixNormal Mass Range, Positive

TFS200

Creating SolutionsLTQ Velos / Hybrid CalMixNormal Mass Range, Positive

TFS210

Creating SolutionsLTQ / Hybrid CalMix

Normal Mass Range, Negative

TFS220

Creating SolutionsTSQ Polytyrosine 1, 3, 6

Positive / Negative

TFS300

Page 4: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

4

Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.

Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.

Precise formulation. Solution of Caff eine, MRFA & Ultra Mark 1621 in ACN/MeOH/Water/AcOH matrix.Specialized. Developed and qualifi ed specifi cally for use with LTQ XL/Hybrid family instruments.

High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.

Compatible MassSpectrometers

LXQLCQ Fleet

LTQ XLLTQ Orbitrap Discovery

LTQ Orbitrap XL Exactive

LTQ FT Ultra

Creating Solutions

TFS200 LTQ XL / Hybrid CalMix Normal Mass Range. For Calibration Mode

The MSPerformance MAX™ LTQ XL / Hybrid CalMix, enables calibration of Thermo Scientifi c Ion Traps, Orbitraps and Hybrid (IT/FT) Mass Spectrometers in positive ion mode. It covers a mass range from

m/z 138 to m/z 1822, and can be used for instrument calibrations between m/z 50 and 2000.

Ordering Information Product Number TFS200 Description LTQ XL / Hybrid CalMix Volume 10ml

TFS200_16042501_ORBI_TL180_mz120-2000 #1-100 RT: 0.01-0.79 AV: 100 NL: 1.45E7T: FTMS + p ESI Full ms [120.00-2000.00]

200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e Ab

unda

nce

195.0869

1421.97411521.96781321.9808

524.2631

1621.9609

262.6352

1221.9879

1721.9544

1121.99461821.9472

1022.0010 1921.9397

138.0656

O N N

NN

O H

O

N 2H

S

ONH

NH

NHN2H

ONH

ONH

OH

HF O

P NP

NP

O

F

N

O

F

FFF

F

F F

FF

F F

O

F

F

FF

FF

F F

O

F

F

F F

FF

F F

FF

F

FFF

F

O

F F

FF

FF

FF

H

MSPerformance MAX™ TFS200 ESI Positive Spectrum.

Page 5: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

5

Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.Precise formulation. Solution of n-Butylamine, Caff eine, MRFA & Ultra Mark 1621 in ACN/MeOH/Water/AcOH matrix.Specialized. Developed and qualifi ed specifi cally for use with LTQ Velos/Hybrid family instruments.High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.

Compatible MassSpectrometersLTQ VelosLTQ Velos ProLLTQ Orbitrap VelosLTQ Orbitrap Velos ProOrbitrap ELITEOrbitrap Fusion TribridExactive PlusQ Exactive/Q Exactive Plus

Creating Solutions

LTQ Velos / Hybrid CalMix TFS210 For Calibration Mode. Normal Mass Range The MSPerformance MAX™ LTQ Velos / Hybrid CalMix, enables calibration of Thermo Scientifi c Ion Traps (Velos family), Orbitraps, Hybrid (IT/FT or Q/FT) and Tribrid (Q/IT/FT) Mass Spectrometers in positive ion mode. It covers a mass range from m/z 74 to m/z 1822, and can be used for instrument calibrations between m/z 50 and 2000.

Ordering Information Product Number TFS210 Description LTQ Velos / Hybrid CalMix Volume 10ml

TFS210_16042502_ORBI_TL120_mz50-2000 #1-100 RT: 0.00-0.79 AV: 100 NL: 2.74E7T: FTMS + p ESI Full ms [50.00-2000.00]

262.6354

195.0871

1521.96851421.9748

1621.96151321.9814

524.2633 1721.95521221.9886

1821.94831121.9951

100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e Ab

unda

nce

74.0958N2H H

O N N

NN

O H

O

N 2H

S

ONH

NH

NHN2H

ONH

ONH

OH

HF O

P NP

NP

O

F

N

O

F

FFF

F

F F

FF

F F

O

F

F

FF

FF

F F

O

F

F

F F

FF

F F

FF

F

FFF

F

O

F F

FF

FF

FF

H

MSPerformance MAX™ TFS210 ESI Positive Spectrum.

Page 6: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

6

TFS220 LTQ / Hybrid CalMix Normal Mass Range. For Calibration Mode

The MSPerformance MAX™ LTQ / Hybrid CalMix, enables calibration of Thermo Scientifi c Ion Trap, Orbitrap, Hybrid (IT/FT or Q/FT) and Tribrid (Q/IT/FT) Mass Spectrometers in negative ion mode. It covers a mass range

from m/z 265 to m/z 1880, and can be used for instrument calibrations between m/z 50 and 2000.

Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.

Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.

Precise formulation. Solution of n-Butylamine, Caff eine, MRFA & Ultra Mark 1621 in ACN/MeOH/Water/AcOH matrix. Specialized. Developed and qualifi ed specifi cally for use with LTQ Velos/Hybrid family instruments.

High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.

Compatible MassSpectrometers

LXQLCQ Fleet

LTQ XLLTQ Velos

LTQ Velos ProLTQ Orbitrap Discovery

LTQ Orbitrap XL LTQ Orbitrap Velos

LTQ Orbitrap Velos ProOrbitrap ELITE

Orbitrap Fusion TribridExactive / Exactive PlusQ Exactive / Q Exactive Plus

Creating Solutions

Ordering Information Product Number TFS220 Description LTQ / Hybrid CalMix Volume 10ml

OS

O

O OH

- H

TFS220_16042503_ORBI_TL120_mz120-2000_NEG #1-100 RT: 0.00-0.82 AV: 100 NL: 4.74E7T: FTMS - p ESI Full ms [120.00-2000.00]

200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e Ab

unda

nce

265.1474

514.2832

1479.98201379.9888 1579.97601679.96921279.9951

1779.96201180.0015 1886.1016

1986.0954

O

OH

F OP N

PNP

O

F

N

O

F

FFF

F

F F

FF

F F

O

F

F

FF

FF

F F

O

F

F

F F

FF

F F

FF

F

FFF

F

O

F F

FF

FF

FF

- H

SO

OOHNH

OH OH

O

OH

- H

MSPerformance MAX™ TFS220 ESI Negative Spectrum.

Page 7: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

7

TSQ Polytyrosine 1, 3, 6 TFS300 For or Calibration ModeThe MSPerformance MAX™ TSQ Polytyrosine 1, 3, 6 calibration solution, enables auto-tune and calibration of Thermo Scientifi c Triple Stage Quadrupole Mass Spectrometers in positive or negative ion mode. It covers a mass range from m/z 182 to m/z 997, and can be used for instrument calibrations between m/z 50 and 1500.

Features and BenefitsReady-to-use. Load the calibration so lution into a syringe and infuse it into the instrument.Colour Coded. Box and vial, for easy identifi cation.High purity analytes. Mass spectrometry grade solvents.Precise formulation. Solution of Tyrosine, Tri-Tyrosine & Hexa-Tyrosine in MeOH/Water/FA matrix.Specialized. Developed and qualifi ed specifi cally for use with TSQ Quantum family instruments.High purity container. Non-leachable, leak-proof polypropylene container.Stable. Store at 2° to 8°C for more than one year.

Compatible MassSpectrometersTSQ Access MaxTSQ Quantum DiscoveryTSQ Quantum UltraTSQ VantageTSQ EnduraTSQ Quantiva

Creating Solutions

Ordering Information Product Number TFS300 Description TSQ Polytyrosine 1,3,6 Volume 10ml

MSPerformance MAX™ TFS300 ESI Positive Spectrum.

TFS300_16033101_TSQ_1 #1-100 RT: 0.02-2.09 AV: 100 NL: 1.23E7T: + p ESI Q1MS [150.070-1050.000]

200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e Ab

unda

nce

508.1581

997.4144

182.0571

N 2HOH

O

OH

H

O

N 2HOHO

NH

OH

ONH

OH

OH

H

O

N 2HOH

O

NH

OH

O

NH

OH

O

NH

OH

O

NH

OH

O

NH

OH

OH

Page 8: MS Performance MAX - RED LINE Calibration Solutionsmsstandards.com/wp-content/uploads/2016/05/... · 2016. 5. 18. · LTQ Velos Pro LLTQ Orbitrap Velos LTQ Orbitrap Velos Pro Orbitrap

Contact Us . . .

Powered by

Creating Solutions

We Can Help_

Webwww.targetanalysis.grwww.msstandards.com

[email protected]

[email protected]

Target Analysis S.A.13 Papanikolaou Avenue 57010 PefkaThessaloniki, Greece