mpv technical presentation copy

15
MassExact Innovative Solutions in SG Measurement

Upload: richard-ducat

Post on 19-Feb-2017

263 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Mpv technical presentation copy

MassExactInnovative Solutions in SG Measurement

Page 2: Mpv technical presentation copy

MassExact Key Features Flow Meter Specifications

Accuracy Applications

Dredging Mining Waste Water Treatment

Competitors

CONTENTS

Page 3: Mpv technical presentation copy

Sampling rate of up to 3,000 times per second Constant monitoring capabilities Bespoke equipment per application

MASSEXACT

Page 4: Mpv technical presentation copy

Custom fit pipe internal diameter from 2 to 42 inches (50-1000mm) Measurements may be calculated in wet density, wet or dry specific gravity, or % dry solids Data interrogations at 33 times per second Bespoke cartridge Full scale sample size Low natural frequency to absorb media vibration

KEY FEATURES

Page 5: Mpv technical presentation copy

Variable output display graphically or numerically Wet or dry totalized mass flow Mass flow rate Wet density Wet or dry specific gravity Percentage of dry solids

Designed specifically to accept MPV sensor inputs Easy navigation for customized calculations, paperless recording, and output to desired location Programmable alarms and alerts allow for quick diagnosis and troubleshooting of the MassExact as well as a higher level of process control Built in thermal, pressure, vibration compensation program packages

MASSEXACT MICRO LOGIC CONTROLLER

Page 6: Mpv technical presentation copy

RECOMMENDED FLOW METERS

Guaranteed accuracy of 0.5% even amidst heavy industrial environments operation in the ‘noisiest’ of slurries

High coil magnetizing current and exciter frequencies to guarantee an excellent ‘signal’ to ‘media noise’ ratio

MassExact compatible with various mass flow meters to calculate wet or dry mass flow rate and totals

CiDRA SonarTrac

Emco UniMag 2

KROHNE Optiflux 4000

Endress and Hauser 55s

Yokogawa ADMAG

Page 7: Mpv technical presentation copy

ACCURACY

PROBLEMPINK NOISE

SOLUTIONMASSEXACT IS PROGRAMMED FOR OPTIMUM CRITICAL AND OVER-DAMPENING ALOGRITHMS. THE TRUEST DENSITY IS PROVIDED WITH MASSEXACTS ABILITY TO TAKE 110 INTERROGATIONS PER SECOND.

PROBLEMTHERMALEXPANSION

SOLUTIONMASSEXACT USES AN INSULATED OUTER CASING TO PREVENT AMBIENT TEMPERATURE AND A CORRECTIVE ALGORHTHM TO ACCOUNT FOR FLUID TEMPERATURE

Page 9: Mpv technical presentation copy

Without the many and almost non-stop dredging operations worldwide, much of the world's commerce would be impaired, often within a few months. One piece of equipment effective for each dredging application. 0.5% Repeatability measuring slurry via varying water sources and densities. Calibration on salt and fresh water respectively Low maintenance of the unit for large diameter applications that are out at sea for extended periods of time.

DREDGING

Page 10: Mpv technical presentation copy
Page 11: Mpv technical presentation copy

Few industries boast as many applications, sectors, and nuances while also spanning global economies. Accurate monitoring and efficiency is essential to the success of this industry and the billions who depend on it. .5% Accuracy and real-time measurement will achieve highly increased efficiency, value, and effectiveness .  Patented in-line cartridge measures up to 3,000 times per second with near perfect accuracy. Complete reference sample for continuous real time evaluation. Increased efficiency and visibility for tighter process controls. Unmatched accuracy and higher sample volume facilitates greater processing of tailings and other low density change measurement.  The abrasion resistant liner is a key solution for highly abrasive slurries and custom units are manufacturable for highly corrosive slurries.

MINING

Page 12: Mpv technical presentation copy
Page 13: Mpv technical presentation copy

Precise continuous measurement at thousands of times a second. Measures to 0.5% accuracy in real-time without interrupting flow. Provides a complete reference sample

WASTEWATER TREATMENT

Page 14: Mpv technical presentation copy
Page 15: Mpv technical presentation copy

ACCURACY

REPEATABILITY

SAMPLE SIZE

RESPONSE TIME

ULTRASONIC

1.0% FULL SCALE

1.0% READING

VOLUME ACCESSIBLE BY PROBE

1-60 SECONDS

M ASSEXACT

0.5% FULL SCALE

0.1% READING

ENTIRE VOLUME

45 MILLISECONDS

MICROWAVE

2.0% FULL SCALE

0.1% TOTAL SOLIDS

VOLUME ACCESSIBLE BY SOURCE

1 SECOND

CORIOLIS

0.02% FULL SCALE

0.01% READING

SAMPLED VOLUME

1-10 SECONDS

NUCLEAR

1.0% SPAN

0.1% FULL SCALE

GAMMA RAY CROSS

SECTION

1-10 MINUTES

MASSEXACT COMPARISONS