MPSEDC
Madhya Pradesh State Wide Area Network
Madhya Pradesh State Electronics Development Corporation Ltd
(MPSEDC)
![Page 2: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/2.jpg)
• Introduction of MPSWAN• Structure of MPSWAN• POP locations details• Network Diagram• POP Equipment Details• IP Address Allocation
Topics
MPSEDC
![Page 3: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/3.jpg)
Introduction to MPSWAN
• MPSWAN is Madhya Pradesh state wide area Network.
• MP SWAN will create a vertical connect(backbone):- A)-SHQ = 1B)-CHQ=10C)-DHQ=39 D)-BHQ=292
• Horizontal- all department will connect.
• MPSWAN will carry data, voice and video traffic.
MPSEDC
![Page 4: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/4.jpg)
Structure of MPSWAN
MPSEDC
![Page 5: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/5.jpg)
Summery of POP Locations
Name of the MPSWAN POP
No. of the vertical POPsNo. of the vertical POPs Operational
No. of the Horizontal connects operational
SHQ 1 1 152
CHQ 10 10 378
DHQ 39 39 594
BHQ 310 282 286
TOTAL 360 332 1410
MPSEDC
![Page 6: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/6.jpg)
• As per the proposed Network Architecture of SWAN, POPs are divided into four groups:
A).Tier-1 POP--NMC at Bhopal.: 01B).Tier-2 POP -- all Divisional HQ: 10 (Excluding State HQ)C).Tier-3 POP -- all District HQ: 39D).Tier-4 POP -- at Block/Tehsil HQ: 310 .
• Apart from this the proposed SWAN network will be divided into two parts namely:-A). SWAN BackboneB).User Departments Connectivity
• SWAN Backbone will be through conventional lease lines and all
MPSWAN backbone lease.
MPSWAN Network
MPSEDC
![Page 7: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/7.jpg)
MPSWAN Network diagram
MPSEDC
![Page 8: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/8.jpg)
DG UPS Router Switch Modems IP Phone PDU SNMP
POP Equipments Details
MPSEDC
![Page 9: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/9.jpg)
1-Disel Generator
A). 8KVA capacity B). Fuel consumption check (by dip level or by flow meter ).C).Check fuel tank, battery status
![Page 10: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/10.jpg)
2-UPS
A). Types of UPS :-1-CHQ/DHQ = 6KVA UPS with 2hours backup.2- BHQ= 3KVA UPS with 4-5 hours backup.
B).As above diagram please ensure all are connected.C).Ensure that all batteries are connected.D).for any UPS complaint :- log to Emerson toll free no :-email id.
![Page 11: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/11.jpg)
3-Router: • Router is a device that connects two networks.
A).Router used in MPSWAN network:• SHQ=Cisco 7609 series.• DHQ\CHQ=Cisco 7206 series• BHQ=Cisco 2821 series• horizontal offices=Cisco 2801 & Cisco 1841 series
MPSWAN Equipments Details
MPSEDC
![Page 12: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/12.jpg)
Cisco 7206 Router
MPSEDC
![Page 13: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/13.jpg)
MPSEDC
![Page 14: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/14.jpg)
MPSEDC
![Page 15: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/15.jpg)
• In Cisco 7206 Six slots are available in Router Front Side.A)-STM Card install in Slot No. 1 and 3B)-E1 Card install at Slot No. 4C)-Slot No. 2,5,6 are Vacant for future use.
• In Cisco 7206 Back Side 4 Slots are available:-A)-In slot 0(zero) three Gigabit interface B)-one fastethernet interface are available.
Interface physical position
MPSEDC
![Page 16: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/16.jpg)
Cisco 2821 Router
MPSEDC
![Page 17: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/17.jpg)
• In Cisco 2821 two Slots are availableA)-In slot zero, two gigabit interface/B)- Two serial interface is install. Serial interface is used for
WAN connectivity.c)-BRI interfaceD)-In slot one, two G.703 port are available. One G.703 port is used connectivity between DHQ to BHQ pop and one is vacant for future use.
Interface physical position
MPSEDC
![Page 18: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/18.jpg)
• Switches are used to connect multiple devices on the same network within a building or campus.
• The data link layer (layer 2) of the OSI model. • Two types of Switch-
A)-Manageable Switch- The switch can be monitored and adjusted locally or remotely to give you control over network traffic. For security we create the VLANs this type of switch.B)-Unmanageable Switch- does not allow you to make changes and Home-networking equipment typically offers unmanaged switches.
• We are use the following Cisco switches-A)-NMC-CISCO-6509B)-POP Room(All)-CISCO 2960
.
4-Switch:-
MPSEDC
![Page 19: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/19.jpg)
Cisco 2960 switch have 48 ports of Fast Ethernet connectivity
Cisco 2960 switch
MPSEDC
![Page 20: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/20.jpg)
• A modem is a communication device that converts binary (digital) signal into analog and analog to binary signals.
• We use One/Two Pairs modem for connectivity-A-Master modem-Install at BSNL or POP end.B-Slave Modem- Install at Customer end.
• How to Connect Modem in Network-A)-Both end v.35
B)-Both end EthernetC)-Customer end V.35 and Exchange end G.703
5-Modems
MPSEDC
![Page 21: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/21.jpg)
Schmid Modem Diagram
MPSEDC
![Page 22: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/22.jpg)
• IP phone is internet protocol phone.
• full-feature telephone that provides voice communication over the same data network.
• When IP phone is registered, phone displaying the Unique no like 1009 or 1008.
6-IP Phone
MPSEDC
![Page 23: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/23.jpg)
Cisco 7970 IP phone
MPSEDC
![Page 24: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/24.jpg)
7-PDU(Power Distribution Unit
• PDU reboot abilities for network access to remote sites and data center equipment the Switched POPS Cabinet .•PDU provides per outlet measurements of current, voltage, power (kW), apparent power, crest factor, and power factor.
![Page 25: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/25.jpg)
•SNMP is the most widely used network management solution for our networks.
•It is an open standard-based framework that is simple but yet flexible enough to manage many different types of devices.
8-Simple Network Management Protocol (SNMP)
![Page 26: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/26.jpg)
Alert Pingo With the help of this Tool we can Monitor our POP
network equipment and Horizontal Client.o Fill the IP address of horizontal and also
description.
![Page 27: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/27.jpg)
![Page 28: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/28.jpg)
ROUTER BASIC COMMAND Ping Traceroute Show run Show ip int brief Show ip protocol Show ?
![Page 29: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/29.jpg)
Use of Ping Ping is a first command to check Network connectivity.
If we phase a problem in our Network then we use ping command to check connectivity.
First we ping Gateway means ip configure at router gigabit port those are connect to switch.
If we get proper response of our gateway means problem is not local end, after that we ping our next hop ip(If we check network from BHQ then next hop ip is DHQ wan ip , if we check network from DHQ then next hop ip is CHQ wan ip and If we check network from CHQ then next hop ip is SHQ wan ip .
![Page 30: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/30.jpg)
Ping
![Page 31: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/31.jpg)
Ping using command prompt
![Page 32: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/32.jpg)
![Page 33: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/33.jpg)
![Page 34: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/34.jpg)
Telnet
![Page 35: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/35.jpg)
Basic Configuration Command in router
![Page 36: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/36.jpg)
![Page 37: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/37.jpg)
Sh Version
![Page 38: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/38.jpg)
MPSEDC
IP Address Allocation
![Page 39: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/39.jpg)
An IP address is a 32-bit number that uniquely identifies a host (computer or other device, such as a printer or router) on a TCP/IP network.
IP addresses are normally expressed in dotted-decimal format, with four numbers separated by periods, such as 192.168.123.132.
IP address
MPSEDC
![Page 40: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/40.jpg)
Class Leftmost bits Start address Finish address
A 0xxx 0.0.0.0 127.255.255.255
B 10xx 128.0.0.0 191.255.255.255
C 110x 192.0.0.0 223.255.255.255
D 1110 224.0.0.0 239.255.255.255
E 1111 240.0.0.0 255.255.255.255
IP Address Classification
MPSEDC
![Page 41: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/41.jpg)
We are using two IP pools 10.124.x.x/16 and 10.125.x.x/16 in our network.
From these pools ip has been created for all horizontal and verticals location.
For ex. Gwalior district block IPs and department IPs has been allotted as follows:-
MPSEDC
![Page 42: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/42.jpg)
Gwailor DHQ - IP Schema
Sr. No.
Tehsil/Sub
Division/ Block name
WAN IP Subnet
connecting to SHQ/DHQ (E1
Link) /30
WAN IP Subnet
connecting to CHQ/BHQ
(E1 Link) /30
PTP Connectivity
for Horizontal/3
0
Total PTP
Network for
Horizontal
Gigaethernet port Port IP
of RouterSwitch IP address
BHQ Off RF/LAN IP address Range
allocated /25
1 Gwalior 10.124.86.1 10.124.86.2
10.124.86.4 &
10.124.87.0127 10.124.88.1 10.124.88.2 10.124.88.0/24
2 Ghatigaon 10.124.89.1 10.124.89.2
10.124.89.4 31 10.124.89.1
2910.124.89.1
3010.124.89.
128
3 Dabra 10.124.90.1 10.124.90.2
10.124.90.4 31 10.124.90.1
2910.124.90.1
3010.124.90.
128
4 Bhitrarwar 10.124.91.1 10.124.91.2
10.124.91.4 31 10.124.91.1
2910.124.91.1
3010.124.91.
128
5 Chinar 10.124.92.1 10.124.92.2
10.124.92.4 31 10.124.92.1
2910.124.92.1
3010.124.92.
128
![Page 43: MPSWAN PPT - AeGM Training](https://reader034.vdocuments.mx/reader034/viewer/2022052313/586cab4b1a28ab1a068b4702/html5/thumbnails/43.jpg)
MPSEDC
Thank You