Moxa I/O Solution – Activate Your Alarm System Prepared by : Rick Peng

Upload: herne

Post on 08-Jan-2016

112 views

Category:

Documents


0 download

DESCRIPTION

Moxa I/O Solution – Activate Your Alarm System. Prepared by : Rick Peng. Success Stories. IP-based Surveillance System With Moxa I/O Solution. Vertical Market Security Customer SIEMENS Security Applications Combine IO access with video surveillance Selected Products - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Moxa I/O Solution – Activate Your Alarm System

Moxa I/O Solution – Activate Your Alarm SystemPrepared by : Rick Peng

Page 2: Moxa I/O Solution – Activate Your Alarm System

Confidential

Success StoriesSuccess Stories

Page 3: Moxa I/O Solution – Activate Your Alarm System

Confidential

IP-based Surveillance System With IP-based Surveillance System With Moxa I/O SolutionMoxa I/O Solution Vertical Market

• Security Customer

• SIEMENS Security Applications

• Combine IO access with video surveillance

Selected Products• ioLogik E2200 series

Why Moxa• Integrate with Moxa Active OPC Server,

free of charge• Active concept can reduce network traffi

c• Click&Go logic provide local control cap

ability

Page 4: Moxa I/O Solution – Activate Your Alarm System

Confidential

Unmanned Base Station MonitoringUnmanned Base Station Monitoring

Vertical Market • Telecom

Customer• Alcatel-Lucent

Applications• IO monitoring for mobile station

Selected Products• ioLogik E2242 200 pcs

Why Moxa• Moxa supports SNMP to I/O function• Moxa I/O Instruction document for what’

s up• Easy to integrate into NMS by SNMP• Click&Go provides local intelligent

Picture from: Alcatel Lucent

Page 5: Moxa I/O Solution – Activate Your Alarm System

Confidential

System Diagram of Base Station System Diagram of Base Station MonitoringMonitoring

AI: M

ain

s

Ele

ctric

ity

AI:

Te

mp

era

ture

AI:

Hu

mid

ity

DI: F

an

A

larm

DI: F

ron

t do

or

intru

sio

n

DI: R

ea

r do

or

intru

sio

n

DI: le

ft-sid

e d

oo

r in

trus

ion

DI: R

igh

t-sid

e d

oo

r in

trus

ion

Page 6: Moxa I/O Solution – Activate Your Alarm System

Confidential

SNMP I/O For Satellite Station SNMP I/O For Satellite Station MonitoringMonitoring Vertical Market

• Telecom Customer

• Confidential Applications

• The customer uses ioLogik E4200 to monitor and control system in satellites station. Such as, angle of satellites, fire alarm, intrusion detection, and temperature.

19" Rack

SNMP Protocol

DO:Control Antenna Angle

DI:Get Antenna position

DI:Get Antenna position

AI: Temperature Sensor

DI: Intrusion Sensor

DI: Fire alarm sensor

SNMP Management

SoftwareSelected Products• ioLogik 4200

Why Moxa•Easy to integrate I/O signals into NMS•Compact size for limited space•Expandable I/O modules without backplane•SNMP protocol

Page 7: Moxa I/O Solution – Activate Your Alarm System

Confidential

Traffic Monitoring System With Traffic Monitoring System With Cellular RTUCellular RTU Background

• From 2009 through to 2013 the A2 motorway in the Lucerne area between Reussegg and Grosshof will be undergoing total reconstruction. The goal is to ensure that the roads and tunnel reach today's level of technology.

Customer’s demand• Remote control and monitoring traffic light• Serial interface for traffic Radar

Why Moxa• All-in-one solution to reduce failure point (I/O + Serial)• Easy-to-use control logic without programming efforts• Active OPC server can talk with WinCC

Customer• Siemens Automation

Page 8: Moxa I/O Solution – Activate Your Alarm System

Confidential

System DiagramSystem Diagram

Moxa Active OPC Server

WinCC/ PVSS

Traffic Control CenterSystem Description-Remote manage the interval of green light They can monitoring and control interval from traffic control center-Serial interface for Traffic radar Get traffic flow information via cellular technology

Yellow Light

Gre

en LightTraffic Radar

ioLogik W5312

Page 9: Moxa I/O Solution – Activate Your Alarm System

Confidential

Application Sharing – Power Application Sharing – Power Substation Management (I)Substation Management (I)

Introduction• In traditional, the client only monitor one fatal alarm in each power su

bstation. Today, they want to improve their monitoring system and provide a more reliable power service for their end customer and reduce their maintenance cost.

Why Moxa• Alarm message via SMS• Click&Go logic• Ethernet/GPRS redundant architecture

Product• W5312 GPRS

Page 10: Moxa I/O Solution – Activate Your Alarm System

Confidential

Application Sharing – Power Application Sharing – Power Substation Management (II)Substation Management (II)

PrimaryEthernet communication

Back Up GPRS communication

Power Substation

Pu

sh

Bu

tton

(Em

erg

en

cy A

larm

)

Ma

gn

etic

Se

ns

or

(Intru

sion

D

ete

ction

)

Sm

oke

Detecto

r(F

ire Alarm

)

La

rge

A

larm

Min

or

Ala

rm

Communication failReal time unit fail

Page 11: Moxa I/O Solution – Activate Your Alarm System

Confidential

Moxa Active Technologies for Moxa Active Technologies for Alarm SystemAlarm System

Page 12: Moxa I/O Solution – Activate Your Alarm System

Confidential

Smart SCADA Connectivity with Smart SCADA Connectivity with Active OPC ServerActive OPC Server

Push-based Active OPC Server Lite – The middleware between ioLogik and SCADA

Page 13: Moxa I/O Solution – Activate Your Alarm System

Confidential

Push-based Active OPC ServerPush-based Active OPC Server

7 times faster response

80% bandwidth saving

1,200 Tags support

Active Tag update

Status change update or periodically update

Page 14: Moxa I/O Solution – Activate Your Alarm System

Confidential

Powerful Data Concentrator – Moxa DPowerful Data Concentrator – Moxa DACenterACenter

DACenter 1.0• Log data into database vi

a DSN• Log data into excel or acc

ess• Provide trend char functio

n for data analysis• Bridge Moxa Active OPC

and database

Page 15: Moxa I/O Solution – Activate Your Alarm System

Confidential

SCADA Database

Moxa Active OPC Server Lite

Moxa DACenter

Tag Access

Ethernet

Active Tag Update

Tag

Acc

ess

Data Conversion

Data Conversion

ExcelAccess

Bridge IT/SCADA SystemBridge IT/SCADA System

Page 16: Moxa I/O Solution – Activate Your Alarm System

Confidential

SCADA Users-Modbus/TCP-Active OPC

IT Users-DACenter for DB-MXIO library-SNMP protocol-TCP/UDP/emailAlarm message

Moxa Automation Solution

Page 17: Moxa I/O Solution – Activate Your Alarm System

ioLogik E1200 Series-Daisy Chain Wiring Can Save Your Cost

Page 18: Moxa I/O Solution – Activate Your Alarm System

Confidential

3 Key Features Of E1200 Series3 Key Features Of E1200 Series

Daisy-Chain Ethernet Architecture can save wiring cost

Active Push Technology with Free Moxa Active OPC server

User-defined Modbus address to replace your existing Ethernet I/O without painful

Page 19: Moxa I/O Solution – Activate Your Alarm System

Confidential

Ethernet Data Acquisition in Daisy-chain Ethernet Data Acquisition in Daisy-chain Topology – Easy CablingTopology – Easy Cabling

I/O

Sensors

I/O

Sensors

I/O

Sensors

I/O

Sensors

I/O

Sensors

I/O

Sensors

Easy wiring, less homerun cabling, and longer distance!

To Central or Controller

100m 100m 100m 100m 100m

With built-in two switch ports on ioLogik E1200

Page 20: Moxa I/O Solution – Activate Your Alarm System

Confidential

Additional Device Connectivity – Easy Additional Device Connectivity – Easy ExpansionExpansion Machine, tools, panels or cabinets

I/O

Sensors

Switch/hub reduction and space saving!

Field Device

To Central or Controller

Page 21: Moxa I/O Solution – Activate Your Alarm System

Confidential

2. Free Push-based Active OPC Server2. Free Push-based Active OPC Server– Efficient Integration and Connection to SCADA– Efficient Integration and Connection to SCADA

Change-on-state tag reports

Patented Automatic Tag Generation

Free of charge

Page 22: Moxa I/O Solution – Activate Your Alarm System

Confidential

Modbus/TCP Polling AddressCompatible

Ethernet I/OEthernet I/OioLogik E1200ioLogik E1200

3.User-defined Modbus Address 3.User-defined Modbus Address – Painless Migrate the Existing system– Painless Migrate the Existing system

No Need to Change the Settings at Central

DI-0_1xxxxx DI-1_1xxxxx DI-2_1xxxxx

DI-0_10001 DI-1_10002 DI-2_10003

User-defined

AddressFixed Address

General SCADA Servers or Field Controller

Page 23: Moxa I/O Solution – Activate Your Alarm System

Confidential

Peer-to-Peer Function on E1200Peer-to-Peer Function on E1200

Easy and effective cable replacement

Various I/O combinations

Configure by web console

Internet-friendly multiple-target transmission

Page 24: Moxa I/O Solution – Activate Your Alarm System

Confidential

ioLogik E1200 – Remote Ethernet I/OioLogik E1200 – Remote Ethernet I/O

ioLogik E1200 series

Interface Ethernet

No

Remote Control

RemarkBuilt-in 2-port

Ethernet Switch

ioLogik I/O

E1210 16 DI

E1211 16 DO

E1212 8DI, 8DIO

E1214 6DI, 6 Relay

E1240 8AI

E1241 4AO

E1242 4AI, 4DI. 4DIO

E1260 6RTD

E1262 8TCioLogik E1200 series

Page 25: Moxa I/O Solution – Activate Your Alarm System

E2000 Series – No1. Easy-to-use Micro RTU Controller

Page 26: Moxa I/O Solution – Activate Your Alarm System

Confidential

ioLogik E2000 Micro RTU ControllerioLogik E2000 Micro RTU Controller

PC-Free Alarm and Control Intelligent• Click&Go logic provides local intelligent

Use SNMP Protocol to Manage All Devices• Support SNMP V1, V2c, and V3

Push Technology for Event and Alarms• TCP/UDP/SNMP Trap/e-mail alarm message

Co-work with IP Surveillance System• Support CGI-command for IP camera and surveillance S

CADA software

Page 27: Moxa I/O Solution – Activate Your Alarm System

Confidential

Click&Go Logic – Configuration OnlyClick&Go Logic – Configuration Only

Intuitive Logic Statement

Pull down menu for condition and actions

Page 28: Moxa I/O Solution – Activate Your Alarm System

Confidential

SNMP Trap With User-defined ContentSNMP Trap With User-defined Content

Support User-defined Content• In traditional, SNMP Trap only provides trap ID

Provide Security Function with

SNMP V.3

Moxa Unique

Feature

User-defined Content

Page 29: Moxa I/O Solution – Activate Your Alarm System

Confidential

Active Tag With Active OPC Server in Active Tag With Active OPC Server in E2000 SeriesE2000 Series

Support up to 5 Active OPC Servers for redundant

Update methods for AI channel-On Change-Update Interval

Page 30: Moxa I/O Solution – Activate Your Alarm System

Confidential

ioLogik E2000 ioLogik E2000 –Micro RTU Controllers–Micro RTU Controllers

ioLogik E2000 series

Interface Ethernet

Remote Control

RemarkOptional LCM

ioLogik I/O

E2210 12DI, 8DO

E2212 8DI, 8DO, 4DIO

E2214 6DI, 6 Relay

E2240 8AI, 2AO

E2242 4AI. 12DIO

E2260 6RTD, 4DO

E2262 8TC. 4O

ioLogik E2200 series

Page 31: Moxa I/O Solution – Activate Your Alarm System

ioLogik W5000-Configurable Cellular RTU

Page 32: Moxa I/O Solution – Activate Your Alarm System

Confidential

General RequirementsGeneral Requirements

Cellular communications1

Active report of serial and I/O data2

Active alarms with Email & SMS3

Local logic control4

Connectivity with SCADA5

Page 33: Moxa I/O Solution – Activate Your Alarm System

Confidential

Most Often Seen SolutionMost Often Seen SolutionPLC + Cellular ModemPLC + Cellular Modem

Page 34: Moxa I/O Solution – Activate Your Alarm System

Confidential

One Example of Existing SolutionOne Example of Existing Solution

SerialPressureFlowTurbidity

GPRSGPRS

SerialPressureFlowTurbidity

SCADA

ProprietaryMiddle WareEx. ODBC, Raw Socket…

SCADA ProprietaryImport Method

Problems: • Application requires on event, periodically, push based communication• SCADA SW did not support push based communication• Many programming efforts on proprietary middleware• Very difficult for PLC to have Socket based push communication• Once it is built, it will be very difficult to replace existing SCADA with another brand• Lighting induced surge often cause GPRS serial port burned down

Page 35: Moxa I/O Solution – Activate Your Alarm System

Confidential

All-in-One Solution ioLogik W5300 All-in-One Solution ioLogik W5300 series with AOPC Serverseries with AOPC Server

PressureFlowTurbidity

SCADAStandard OPC

GPRSGPRS

PressureFlowTurbidity

Active OPCServer

• GPRS Modem + I/O + Controller integrated solution Easier to trouble shoot• No serial lines avoid lighting induced serial port burn out• No GPRS dialup programming needed

• Click&Go logics no need of programming for SMS or email alarms• Standard OPC connectivity, compatible with any SCADA software• Solve also private IP and dynamic IP issues• Data logging and sleeping mode, low power usage

Page 36: Moxa I/O Solution – Activate Your Alarm System

Confidential

Moxa’s Cellular RTU SolutionMoxa’s Cellular RTU Solutionfor Remote DAQ Applicationsfor Remote DAQ Applications

Page 37: Moxa I/O Solution – Activate Your Alarm System

Confidential

Dynamic/Private IP Management

Moxa Active OPC Server can manage Moxa Active OPC Server can manage private and dynamic IPprivate and dynamic IP

InternetInternet

GPRS Network

GPRS Network

Active OPC ServerWith Static IP

SCADA

Registering in Active OPC server Actively

Bi-Direction Connection

1

2

Current Solutions for GPRS application

VPN service from carriers or MVNOs

Public Static IP: $$$$

DDNS: Complex

Page 38: Moxa I/O Solution – Activate Your Alarm System

Confidential

Simple GPRS ConfigurationSimple GPRS Configuration

Get IP address from Carrier

Signal Strength - RSSI

Define Active OPC Server IP

Page 39: Moxa I/O Solution – Activate Your Alarm System

Confidential

Creating Tags to AOPC Server Takes Creating Tags to AOPC Server Takes Just a Few ClicksJust a Few Clicks

Setting of AOPC Server IP

AI tag push supports:• on AI value change %• on time interval

DI push on status change

Page 40: Moxa I/O Solution – Activate Your Alarm System

Confidential

Powerful Reconnection Design to Powerful Reconnection Design to Provide Reliable GPRS Comm.Provide Reliable GPRS Comm.

Check connection with Carrier

Ping function to detect Internet Communication

Data Logging for Network Traffic

Page 41: Moxa I/O Solution – Activate Your Alarm System

ConfidentialConfidential

Virtual Channel With Calculation Virtual Channel With Calculation FunctionFunction Work with “AI” and “Counter with Scaling” with

multiple operation

(1) Maximum (max value in a defined time period)(2) Minimum (min value in a defined time period)(3) Average (avg. value in a defined time period)(4) Accumulation (accumulate value in a defined time period)(5) Instantaneous (real-time value at a defined time)(6) Incremental (increased value in a defined time period)

Page 42: Moxa I/O Solution – Activate Your Alarm System

Confidential

Easy to Use eMail & SMS AlarmsEasy to Use eMail & SMS Alarms

User definable content:• I/O status• Time stamp• Server info• Support Unicode

Support 5 Phone No.

Page 43: Moxa I/O Solution – Activate Your Alarm System

Confidential

Profile-style Data Logging for I/OsProfile-style Data Logging for I/Os

43

E-mail Attachment

Up-to-5 profile Configuration

Log to SD card (max. 2GB)

Configure What, When and How to log.

Log Retrieval

Configure when and how to retrieve the log files

Page 44: Moxa I/O Solution – Activate Your Alarm System

Confidential

Complete Data Logging and Analysis Complete Data Logging and Analysis with On-line/Off-line Data Integrationwith On-line/Off-line Data Integration

network down, data lost !

Off-line Log Retrieval, Complete the Data Set !

Page 45: Moxa I/O Solution – Activate Your Alarm System

Confidential

Primary/Backup Interface SelectionPrimary/Backup Interface Selection

45

Page 46: Moxa I/O Solution – Activate Your Alarm System

Confidential

New Cellular Operation ModeNew Cellular Operation Mode

Ethernet WAN (Cellular Backup)

46

Redundant Network (Ethernet WAN) Failure detection, Switch to the backup (Cellular) or roll back to the primary Ethernet.

Page 47: Moxa I/O Solution – Activate Your Alarm System

Confidential

Port ForwardingPort Forwarding

47

Internet Access

Page 48: Moxa I/O Solution – Activate Your Alarm System

Confidential

Port ForwardingPort Forwarding

Activated when using Cellular as Primary Interface

48

Page 49: Moxa I/O Solution – Activate Your Alarm System

Confidential

DDNS is Newly SupportedDDNS is Newly Supported

New way to handle the dynamic IP address

“DynDns.org” only

49

Page 50: Moxa I/O Solution – Activate Your Alarm System

Confidential

SMS Escalation and AcknowledgeSMS Escalation and Acknowledge

50

Page 51: Moxa I/O Solution – Activate Your Alarm System

ConfidentialConfidential

Settings of SMS Alarm EscalationSettings of SMS Alarm Escalation

Recipient sequence

No reply timeout

SMS content

Page 52: Moxa I/O Solution – Activate Your Alarm System

Confidential

SMS Acknowledgement SMS Acknowledgement

Reply code and message are sent with the SMS message.

52

Page 53: Moxa I/O Solution – Activate Your Alarm System

Confidential

SMS CommandsSMS Commands

Message Format: ASCII

Max Characters: 160

Command Categories • Get Input/Output Status• Get system status• Set output status• Set Internal Registers

Security using Console Password is applied• Define password for W5000 via ioAdmin

53

E1200 I/O Expansion

Page 54: Moxa I/O Solution – Activate Your Alarm System

ConfidentialConfidential

SMS CommandsSMS Commands

Format: #GetSMS?command _channel=?&command _channel=?.....#

#SetSMS?command _channel=?&command _channel=?.....#

SMS set and get I/O status• Get command:

#GETSMS?LOC=?&TIME=?&AIValue_00=?#• Set command:

#SETSMS?AOValue_00=4095&DOStatus_00=1#

SMS change internal register value#SETSMS?IR_00=1# (IR value range 0-255)

Page 55: Moxa I/O Solution – Activate Your Alarm System

ConfidentialConfidential

Modbus RTU Serial TagsModbus RTU Serial Tags

Modbus Serial

Modbus Slave

Modbus Master

Polling

ioLogik W5340-HSDPA

3G Networks

3G Networks

AOPC Server

SCADA

Active Serial Tag

Page 56: Moxa I/O Solution – Activate Your Alarm System

ConfidentialConfidential

Active Tag Function – New TagsActive Tag Function – New Tags

I/O tag types• DI• DO• AI• Virtual channel• RSSI value• Alive check

Update criteria• On change• By time interval

Page 57: Moxa I/O Solution – Activate Your Alarm System

Confidential

Float Internal RegisterFloat Internal Register

Page 58: Moxa I/O Solution – Activate Your Alarm System

Confidential

Expendable up to 3 External E1200 ModulesExpendable up to 3 External E1200 Modules

ioLogik W53404AIs, 12DIOs, 2 Relays

ioLogik E121016DIs

ioLogik E12408AIs

ioLogik E12146DIs, 6 Relays

Ethernet

ioLogik I/O

E1210 16 DI

E1211 16 DO

E1212 8DI, 8DIO

E1214 6DI, 6 Relay

E1240 8AI

E1241 4AO

E12424AI, 4DI.

4DIO

E1260 6RTD

E1262 8TC

Need More IO Channels?

Extend via E1200 series

Supported E1200

Page 59: Moxa I/O Solution – Activate Your Alarm System

Confidential

ioLogik W5000 ioLogik W5000 – Cellular RTU Controllers– Cellular RTU Controllers

ioLogik W5340W5340-T

W5312W5312-T

W5340-HSDPAW5340-HSDPA-T

Interface

I/O Type 4AI, 8DIO, 2 Relay 8DI, 8DO, 4DIO 4AI, 8DIO, 2 Relay

Remote Control

Remark 3-in-1 Serial Port, SD Storage

3-in-1 Serial Port, SD Storage

3-in-1 Serial Port, SD Storage, VPN-

IPSec

ioLogik E5000 series

Page 60: Moxa I/O Solution – Activate Your Alarm System

ioPAC 4200 Series-Intelligent Modular I/O

Page 61: Moxa I/O Solution – Activate Your Alarm System

Confidential

Product FeaturesProduct Features

Slice Form Factor, High Density Modular I/O

Event Base Logic up to 80 rules and Unicode Message

Dual Ethernet LANs Support

Support SMS (Short Message Service) via GSM/GPRS modem

Flexible, Various I/O Module Choice

Great Expanding Capability - Up to 256 Digital Input/Output Points

Auto Detection of installed Modules

Build-in Web Console

P.S. A GPRS modem is a GSM modem that additionally supports the GPRS technology for data transmission. GPRS stands for General Packet Radio Service. It is a packet-switched technology that is an extension of GSM. (GSM is a circuit-switched technology.) A key advantage of GPRS over GSM is that GPRS has a higher data transmission speed.

Page 62: Moxa I/O Solution – Activate Your Alarm System

Confidential

Great Expanding Capability Great Expanding Capability - Up to 256 Digital Input/Output Points - Up to 256 Digital Input/Output Points

Support up to 16 modules without backplane Up to 256 Digital Input/Output Points or Up to 64 Analog Input points or Up to 32 Analog Output

Up to 16 Modules

Up to 16 Modules

Page 63: Moxa I/O Solution – Activate Your Alarm System

Confidential

Auto Detection of installed Modules Auto Detection of installed Modules

What You See is What You Installed Dynamic Modbus Table

Page 64: Moxa I/O Solution – Activate Your Alarm System

Confidential

Dual Ethernet LANs Support Dual Ethernet LANs Support

Dual LAN ports with two MAC, two IPs

Two doors to reach different LAN

LAN 1

LAN 0

SMS Alarm

Page 65: Moxa I/O Solution – Activate Your Alarm System

Confidential

Support Standard AT Command GSM modem Support Standard AT Command GSM modem

Setting Free while you use SMS in Click&Go Rules

While using OnCell 2110/2150• You can check the modem status on Web

Page 66: Moxa I/O Solution – Activate Your Alarm System

Confidential

Build-in Web Console Build-in Web Console

Page 67: Moxa I/O Solution – Activate Your Alarm System

Confidential

ioLogik E4200ioLogik E4200– Intelligent Modular I/O– Intelligent Modular I/O

ioLogik E4200 series

ioLogik E4200 series

Interface Ethernet

Remote Control

Remark

SMS function with serial interface

(Moxa G2150I)

M Series I/OM1800 8Ch, Sink, DI

M1801 8Ch, Source, DI

M1600 16Ch, Sink, DI

M1601 16Ch, Source, DI

M1450 4Ch, 110VAC, DI

M1451 4Ch, 220VAC, DI

M2800 8Ch, Sink, DO

M2801 8Ch, Source, DO

M2600 16Ch, Sink, DO

M2601 16Ch, Source, DO

M2450 4Ch, Relay

M3802 8Ch, 4~20mA, AI

M3810 8Ch, 0~10V, AI

M6200 2Ch, RTD

M6201 2Ch, TC

M4402 4Ch, 4~20mA, AO

M4410 4Ch, 0~10V, AO

Page 68: Moxa I/O Solution – Activate Your Alarm System

ioPAC 8000 Series-Rugged I/O Solution

Page 69: Moxa I/O Solution – Activate Your Alarm System

Confidential

System CoverageSystem Coverage

Refurbishment of mid-life train • No replacement of current control system• Conjunction control with existing system

Ethernet-based solution for data acquisition

Cost-effective rolling stock I/O solution

Wayside Monitoring System

Suitable solution for POS (Passenger Oriented System)

Page 70: Moxa I/O Solution – Activate Your Alarm System

Confidential

Rugged I/O for Rolling StockRugged I/O for Rolling Stock

Modular Rugged I/O• ioPAC 8020

Compact & Standalone Rugged I/O• ioLogik E1500-T series

-Door Status-LED indicator-Temperature-Seat reservation-HVAC

-Door Status-LED indicator-Temperature-Seat reservation-HVAC

ioPAC 8020

ioLogik E1500 ioLogik E1500

Page 71: Moxa I/O Solution – Activate Your Alarm System

Confidential

Wayside Monitoring ArchitectureWayside Monitoring ArchitectureOCC1OCC1 OCC2OCC2

Giga-Ring

Section1Section1 Section2Section2 Section3Section3 Section4Section4 Section5Section5 Section20Section20 Section21Section21 Section22Section22

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

WW

WW

WW

WW

WW

WW

WW

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

WW

WW

WW

WW

WW

WW

WW

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

RHRH

WW

WW

WW

WW

WW

WW

ww

*RH: Relay House*W: Wayside Cabinet

Page 72: Moxa I/O Solution – Activate Your Alarm System

Confidential

Architecture of Wayside CabinetArchitecture of Wayside Cabinet

ATP LEU

balise signal

Camera

Level crossing

Switchmachine

Trackcircuit

ChargerAxle counter

ioPAC 8020With C or IEC 61131-3

Relay House

ioLogik E2210 for Alarm System

Page 73: Moxa I/O Solution – Activate Your Alarm System

Confidential

ioPAC 8020 SeriesioPAC 8020 Series

One 3in1 Serial

2 ports 10/100Mbps EthernetWith M12 connector (Build-in Switch)

Heat Sink(Wide Temperature -40C ~ 75C)

Primary Power Input

4 I/O Slots

Secondary Power Input or 5th I/O Slot

Hot swappable I/O Module

Anti-vibration Terminal Block

LED indicator for I/O module

Moxa ART CPU in-side

SD Slot

Page 74: Moxa I/O Solution – Activate Your Alarm System

Confidential

ioPAC 8020 Software InterfaceioPAC 8020 Software Interface

Page 75: Moxa I/O Solution – Activate Your Alarm System

Confidential

Moxa I/O Product OfferingMoxa I/O Product Offering

Page 76: Moxa I/O Solution – Activate Your Alarm System

Confidential

E1200E1200 E1241, 4AO E1242, 4AI+4DI+4DIO E1260, 6RTD E1262, 8TC

Dais-ch

ain

Eth

ernet

RS

485I/O

Rem

ote I/O

Ru

gg

ed S

eriesC

ellular M

icro

Co

ntro

ller

Au

tom

ation

Co

ntro

ller

Stan

d-alo

ng

E

thern

et

E2000 Wide Temp-E2242-T 4AI+12DIO

Mo

du

lar

E2000-E2210 8DI+12DO-E2214 6DI+6Relay-E2240 8AI+2AO-E2242 4AI+12DIO

E1200E1200 E1210, 16DI E1211, 16DO E1212, 8DI+8DO E1214, 6DI+6Relay E1240, 8AI

Mo

du

lar

E4200 -Up to 256 DIO or 128 AIO

W5340-HSDPA- 3.5G (HSDPA)

W5340-TW5340-T- 4AI+8DIO+2Relay

W5340- 4AI+8DIO+2Relay

W5312-8DI+8DO+4DIO

R2000-R2110 8DI+12DO-R2140 8AI+2AO

E2000-E2260 6RTD+4DO-E2262 8TC+4DO-E2212 8DI+8DO+4DIO

NA4010-10/100 Mbps Ethernet

NA4020-RS485

NA4020-RS232

ioPAC 8020-5 I/O slots

I/O Modules:-24V 16CH DI module-24V 10CH DI w/ isolation-110V 10CH DI w/ isolation-4~20mA 8CH AI module

DA

C In

du

strial I/O P

rod

uct P

ortfo

lio

C/C++ and IEC61131 ioPAC 8020

(Available in June)

C/C++ and IEC61131 W5348

(Available in June)